A Study on the Effectiveness to the Life Safety by Enlarging Smoke Vent Size and/or Sprinklered System (배연창 크기와 스프링클러 작동이 인명안전에 미치는 영향 연구)

  • Kim, Hak-Joong;Park, Yong-Hwan;Lim, Choe-Hyun;Kim, Bum-Kyu
    • Fire Science and Engineering
    • /
    • v.24 no.2
    • /
    • pp.133-138
    • /
    • 2010
  • Recently, evacuation safety of a resident of building become the major concern, because building has been higher and more complicated. Buildings in Korea should install the natural smoke venting or mechanical smoke exhaust equipment according to the building law. The smoke control is the most important to guarantee the evacuation safety. This study evaluate the influence to the height and temperature of smoke layer by enlarging smoke vent size and operating sprinkler system using CFAST (Version 6). Smoke venting size is larger, the effect to height and temperature of smoke layer is increased in below 5 MW fire. But, the correlation of these is decreased in above 10 MW fire. The case that opened smoke vent and sprinklered are applied, life safety criteria are satisfied regardless of fire size. After design the fire scenario according to the service and size of building. Install the smoke vent suitable for the fire size and verify that by experiment or simulation.

Development and Performance Evaluation of Under Cut Anchor Stone Curtain Wall Construction Method (언더컷 앵커 방식의 석재 커튼월 공법 개발 및 성능평가)

  • Chang, Kug-Kwan;Park, Nam-Wook
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.4
    • /
    • pp.138-146
    • /
    • 2014
  • Structural safety as well as variety and aesthetics of building facade are currently gathering more attention in building construction and stone curtain wall is widely used in exterior wall. However, two main problems are existed in curtain wall construction method. One is an uniformity of construction quality and the other is a repair work of stone panels. Also, the noise and vibration occurring in construction may be cause of civil complaint. Therefore, a new method is needed to overcome these problems. This paper presents a new stone curtain wall system using under cut anchor and secondary holes that was developed in this study. Additionally, structural performance evaluation was conducted to verify the constructability and structural safety for wind pressure and seismic load. Through the evaluation of this method, improved constructability and economic efficiency were verified.

A Study on basic theory in fire simulation using SOFIE (SOFIE를 활용한 화재 시뮬레이션에 관한 기초적 연구)

  • Lee, Jung-Hyun;Kim, Hak-Chul
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.266-269
    • /
    • 2012
  • 화재 시뮬레이션을 이용하면, 건축물에서 화재가 발생하는 경우 건물에 설치된 감지 시스템 및 자동식 소화설비 등의 작동 여부에 따라 건물 내부의 온도 변화, 산소 및 일산화탄소 농도 변화, 연기유동 현상 등 화재 안전에 관련된 요소를 확인, 분석이 가능하기 때문에 건물의 화재 안전성을 검증하는데 활용할 수 있고 방재시스템 설계 조건을 변경하여 반복 시뮬레이션을 실시함으로써 보다 효율성이 높은 방재 시스템을 설계 및 채택할 수 있다. 또한 화재 시뮬레이션 결과를 감안하여 유사시 효과적으로 대응할 수 있도록 방재계획을 수립할 수 있고, 건축물의 구조, 내장재 및 수용품에 대한 설계, 배치 등에 사용할 수 있으며, 화재사고조사 및 원인 규명에도 활용할 수 있는 등 화재 시뮬레이션의 활용분야는 광범위하다. 최근 국내에도 화재로 인한 인적/물적 피해와 화재 안전 설계에 대한 관심증가로 화재 모델에 대한 많은 연구가 이루어지고 있다. 그러나 대부분의 연구가 시뮬레이션을 이용한 결과 분석에 치중되어있고 화재 시뮬레이션에 관한 특성 연구 및 개발은 거의 이루어지지 않고 있다. 본 자료는 국내에서 화재 시뮬레이션 코드로 많이 알려지지 않았으며, 유럽에서 개발된 SOFIE(Simulation of Fire in enclosures)에 대해서 기초적인 연구를 수행하였으며, SOFIE에 대한 특정 문제나 평가 부분은 다루지 아니하였다.

  • PDF

A Study on the Evaluation of Evacuation Safety in Welfare Facilities of Handicapped (장애인 복지시설의 피난안전성평가에 관한 연구)

  • Hong, Hae-Ri;Seo, Dong-Goo;Kwon, Young-Sook;Kwon, Young-Jin
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.11a
    • /
    • pp.344-347
    • /
    • 2011
  • 최근 대형화된 재난사고가 빈번히 발생하고 있으며 이에 따른 건축물의 피난설계가 중요시 되고 있지만 일반인에 비해 재해 시 피난이 곤란한 재해약자가 이용하는 시설에서의 성능설계나 피난계획은 미흡한 실정이다. 따라서 본 연구에서는 국내 장애인 복지시설을 대상으로 피난안전성평가를 실시하여 그 문제점을 도출하였으며 그 결과 장애인시설의 피난안전을 위해서는 피난개시시간, 엘리베이터 피난, 내장재, 발코니 유무, 출구 폭 등의 문제점에 관한 대책이 시급하며 또한 성능기반 피난안전설계 의무화가 우선시 되어야 할것으로 판단되었다.

  • PDF

A Study on Evaluation Plan of Fire Safety Performance for Public Building (공동주택의 화재안전성능 평가방안에 관한 연구)

  • Ku, Jae-Hyun
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.4
    • /
    • pp.25-32
    • /
    • 2019
  • From the viewpoint of fire-fighting activities, public building have structural and management problems in fire, so evacuation disturbance and risk of expanding combustion are high. As a result of analyzing various fire fragile factors of public building, The evaluation areas were derived from safety systems, fire-fighting facility, structure safety, general safety and the evaluation factors were presented. Also, the characteristics of domestic and foreign certification systems were analyzed by comparing and analyzing the status of fire safety performance certification system for 6 domestic and overseas apartment houses. In conclusion, the 5 convergence directions of certification system and 22 evaluation items by 4 evaluation fields were derived, and based on this, we have established 3 convergence introduction plans of fire safety performance certification system of public building.

A study of on the occupant movement speed during emergency evacuations for the evacuation safety assessment of domestic buildings (국내 건축물의 피난안정성평가를 위한 비상대피 시 재실자 이동속도에 관한 연구)

  • Youn, Ho-Ju;Hwang, Eunkyung
    • Journal of the Society of Disaster Information
    • /
    • v.9 no.3
    • /
    • pp.332-338
    • /
    • 2013
  • Recently in Korea, in order to ensure evacuation safety within buildings, reviewing and evacuation assessment using computer simulations has been performed from the planning and design stages. Since the results from the assessment mainly depends on the initial values of input elements, it is important to establish element specific data. Nevertheless evacuation related experiments and research are still insufficient to apply overseas standards to domestic conditions. This study intended to conduct a experiment on evacuation movement speed by age as part of element-specific data construction for domestic occupant movement speed. After analyzing domestic and overseas studies on evacuation movement speed, we conducted the experiment of evacuation movement speed for 134 people. Then, by carrying out a comparative analysis of the results of the movement speed obtained from the experiment with overseas movement speeds, we followed the validation procedures of the experimental results under domestic evacuation conditions. The data derived from the experiment is expected to serve as a basis for the movement speed of domestic evacuation safety assessment.

바다골재채취에 따른 주변수역 통항선박의 안전성 평가에 관한 고찰

  • Kim, Se-Won;Park, Yeong-Su;Jo, Ik-Sun;Lee, Yun-Seok;Yun, Gwi-Ho;Kim, Jin-Gwon
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2012.10a
    • /
    • pp.222-224
    • /
    • 2012
  • 최근 들어서 우리나라는 각종 육해상 건축물 축조에 필요한 모래골재의 육상공급이 한계에 다다르면서 부족한 골재를 인근해역의 해저에서 채취하여 공급하고 있으며, 이에 따른 해저 골재채취 작업수역을 통항하는 선박들의 안전문제가 크게 대두되고 있다. 이와 관련하여 최근에 태안해역의 흑도/가대암 TSS 부근수역에서의 바다골재 채취를 위한 해상교통안전진단 사업을 수행한 내용을 중심으로 주변수역으로 통항하는 선박들의 통항안전성에 대하여 평가한다.

  • PDF

Safety Evaluation of Void Plywood Slab System with form Work Panel (거푸집 패널이 부착된 중공슬래브의 안전성 평가)

  • Hur, Moo-Won;Chae, Kyoung-Hun;Park, Tae-Won;Kang, Hyun-Wook;Park, Hyun-Soo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.6
    • /
    • pp.185-192
    • /
    • 2021
  • In this study, Full-scale hollow slab Mock-up with VPS(Void Plywood Slab System) was produced. Through Mock-up, the safety of the flat plate hollow slab against short-term sagging and long-term sagging is to be evaluated. The hollow rate of the mock-up specimen to which the hollow core slab was applied was designed to be 24%. When loading through concrete blocks, the most central part of the slab was deflection 8.88mm when loading. However, it shows a safe value compared to the reference value (ln/240=17.93mm) for short-term deflection. As a result of 3 months of measurement of the mock-up experiment, the deflection at the center of the slab increased by 6.792mm from the initial deflection. In addition, it was found that the reference value by the load used suggested by KBC2016 was satisfied.

Dynamic Responses of Base Isolation Devices for Telecommunication Equipment in Building Structures (건축물 내 방송통신설비를 위한 면진장치의 동적거동)

  • Jeong, Saebyeok;Choi, Hyoung-Suk;Seo, Young-Deuk;Jung, Donghyuk
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.1
    • /
    • pp.39-48
    • /
    • 2022
  • In earthquake situations, broadcasting and communication services are directly linked to rapid on-site rescue and effective restoration works. Recently, a variety of base isolation devices are widely introduced on building floors to avoid critical seismic damages of telecommunication facilities. However, in buildings with long fundamental periods, those devices may have undesirable amplification of seismic responses due to resonance effect between the building floors and base isolation devices. This study performs the seismic safety evaluation of two types of base isolation devices deployed for telecommunication facilities in mid- and high-rise buildings through numerical and experimental approaches. It is found that mid- and high-rise buildings can have low-frequency dynamic responses at the top floor when being subjected to design basis earthquake loading. Furthermore, bi-directional shake table testing demonstrated that the selected base isolation devices can exhibit unstable dynamic behaviors under such low-frequency excitations of the floor.

A Study on Colors through Regeneration Design for Abandoned Factory Buildings - The Color of Buildings in the Port Area of Bongnae-dong, Yeongdo, Busan as an Example - (폐공장 건물 재생디자인에 대한 색채 관한 연구 - 부산 영도 봉래동 항만지역 건축물 색채를 중심으로 -)

  • Li, XinTong;Zhang, Ning;Cho, Joung-Hyung
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.10
    • /
    • pp.177-188
    • /
    • 2021
  • In South Korea, with the advancement of the 'Port' project, the regeneration industry adapted to the modern economic development has been promoted, leading to construction around the port was also redefined. Therefore, through regeneration, the problem of image construction of buildings around the port has been re-examined, in which color is an important content of image construction. In this study, the exterior walls of abandoned factory buildings in the port area of Bongnaedong, Pusan were selected as the color research object and evaluated according to the characteristics of the regenerated factory buildings combined with the building color function. Technically, KSCP color analysis system is used for color analysis. In this way, the color plan for the exterior walls of the factory buildings is proposed to visually enhance the image of abandoned factory buildings and attract more attention, thus driving the regional economic development. The results of this study show that in order to adapt to the regional, industrial and commercial characteristics of the regenerated port space, the color hue, lightness, chroma and use area of the building can be changed to enhance the aesthetic value and enhance the inductivity and security.