• Title/Summary/Keyword: 건축물 구조해석

Search Result 430, Processing Time 0.021 seconds

A Study on Compressive Strength of Built-up H Shaped Columns Fabricated with HSA800 High Performance Steels (건축구조용 고성능강(HSA800) 용접 H형단면 기둥의 압축강도에 관한 연구)

  • Kim, Tae Soo;Lee, Myung Jae;Oh, Young Suk;Lee, Kang Min;Kim, Do Hwan
    • Journal of Korean Society of Steel Construction
    • /
    • v.24 no.6
    • /
    • pp.627-636
    • /
    • 2012
  • Recently, high performance(strength) steels have been utilized to structural materials in buildings and bridges with the demand for high-rise and long-span of main structures. This paper is a series of basic study for the design specification of structural members using high performance steel, material properties of high performance rolled steel building structures; material properties of HSA800 steel was compared with the requirements of Korean Standards(KS) for HSA800. Welded H-shape stub columns with variables of width-to-thickness ratios are planned in order to investigate the local buckling behaviors and check the current design limit of width-to-thickness ratio and uniaxial compressive tests are carried out. In addition, the buckling behaviors of stub columns obtained finite element analysis were compared with those of test results.

Evaluation on Applicability of Built-up Square Tubular Compression Members Fabricated with HSA800 High Performance Steel Considering Local Buckling (국부좌굴을 고려한 건축구조용 고성능강(HSA800) 조립각형강관 압축재의 적용성 평가)

  • Yoo, Jung Han;Kim, Joo Woo;Yang, Jae Guen;Kang, Joo Won;Lee, Dong Woo
    • Journal of Korean Society of Steel Construction
    • /
    • v.25 no.3
    • /
    • pp.223-231
    • /
    • 2013
  • Recently, high-performance steels have been increasingly used for structural materials in buildings and bridges with the demand for high-rise and long-span of main structures. This paper offers a series of basic study for the design specification of structural members using high performance steel, that is material properties of HSA800 (High-performance rolled steel for building structures). Built-up square tube stub columns with variables of width-to-thickness ratios are planned as a parametric study in order to investigate the local buckling behaviors and check the current design limit of width-to-thickness ratio. In addition, the buckling behaviors of stub columns obtained finite element (FE) analysis were compared with those from experimental tests. The verified FE model was used for parametric study and checked applicability of high-strength steel on current design specification.

Study on the Surface Temperature and Fire Protective Thickness for Structural Steel Elements at Fire Conditions (강구조 부재의 표면온도 산정 및 내화피복두께에 관한 연구)

  • Kwon, In-Kyu
    • Fire Science and Engineering
    • /
    • v.24 no.4
    • /
    • pp.55-61
    • /
    • 2010
  • Fire resistance is very essential for all buildings to save peoples who live within buildings or use and to protect the properties when the buildings are covered with fire. The fire resistance were evaluated by loading or nonloading fire tests which are known very expensive and require lots of time. That causes the lacks of research activities and there are only small cases of fire resistance. The purposes of this paper are to analyze the temperature analysis for various structural elements such as columns and beams those are can be applied to buildings and to suggest the resonable fire protective thickness of concrete slab according to the required fire resistance time.

Real-time Hybrid Testing a Building Structure Equipped with Full-scale MR dampers and Application of Semi-active Control Algorithms (대형 MR감쇠기가 설치된 건축구조물의 실시간 하이브리드 실험 및 준능동 알고리즘 적용)

  • Park, Eun-Churn;Lee, Sung-Kyung;Lee, Heon-Jae;Moon, Suk-Jun;Jung, Hyung-Jo;Min, Kyung-Won
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.21 no.5
    • /
    • pp.465-474
    • /
    • 2008
  • The real-time hybrid testing method(RT-HYTEM) is a structural testing technique in which the numerical integration of the equation of motion for a numerical substructure and the physical testing for an experimental substructure are performed simultaneously in real-time. This study presents the quantitative evaluation of the seismic performance of a building structure installed with an passive and semi-active MR damper by using RT-HYTEM. The building model that was identified from the force-vibration testing results of a real-scaled 5-story building is used as the numerical substructure, and an MR damper corresponding to an experimental substructure is physically tested by using the universal testing machine(UTM). The RT-HYTEM implemented in this study is validated because the real-time hybrid testing results obtained by application of sinusoidal and earthquake excitations and the corresponding analytical results obtained by using the Bouc-Wen model as the control force of the MR damper respect to input currents were in good agreement. Also for preliminary study, some semi-active control algorithms were applied to the MR damper in order to control the structural responses optimally. Comparing between the test results of semi-active control using RT-HYTEM and numerical analysis results show that the RT-HYTEM is more resonable than numerical analysis to evaluate the performance of semi-active control algorithms.

State-of-art on Its Application and Errors in Pushover Analysis of Building Structures (건축물의 내진설계에서 정적 비선형해석의 적용과 오차에 대한 고찰)

  • Jun, Dae-Han;Song, Ho-San
    • Journal of Korean Association for Spatial Structures
    • /
    • v.5 no.1 s.15
    • /
    • pp.99-105
    • /
    • 2005
  • The pushover analysis is becoming a popular tool for seismic design of building structures. In this paper the state-of-art on static nonlinear analysis of building structures is presented with the emphasis on the effects of analysis parameters; i. e., lateral load patterns, modeling of members, and analysis computer programs. The analysed results may have variation even if a same structure is analysed. This paper is to investigate how large the variation is and what the main causes of the variation are. The difference of analysed results, the resultant variation of lateral story shear force and flexural strength of structural members are discussed. The pushover analysis procedure are routinely used in the seismic design of building structures, but some problems must yet be clarified, such as the effects to evaluate the parameters of analysis on the basis of a lateral load patterns and modeling of members.

  • PDF

Seismic Response Estimation and System Identification of Test Steel Structure Using Approximate Nonlinear Filter (비선형 근사필터에 강구조시험체의 지진응답추정 및 동특성식별)

  • 배기환;김두영
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.5 no.2
    • /
    • pp.67-72
    • /
    • 2001
  • 대상으로 하는 시스템의 입출력신호에 근거하여, 시스템의 수학적 모델을 결정하는 것을 총칭하여 시스템식별이라 한다. 본 논문에서는 지진응답 관측치를 입출력신호로 하여 조건부대치를 최적치로 판단하는 비선형근사필터법을 사용한 건축구조물의 지진응답추정 및 파라미터식별에 관하여 논한다. 비선형근사필터법에 의한 건축구조물식별의 유효성의 적용성을 판단하기 위해, 진동대를 사용하여 강구조시험체의 진동실험을 행하고 결과적으로 얻어진 시험체의 수학적 모델에 대한 지진응답 수치해석결과와 진동실험에서의 관측기록을 비교하여 본 식별법의 타당성을 보인다.

  • PDF

Vibration Analysis of Building Floor Subjected to Walking Loads (보행하중을 받는 건축물 바닥판의 진동해석)

  • 김기철;이동근
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2001.04a
    • /
    • pp.414-421
    • /
    • 2001
  • Recently, the damping effect of building structures are greatly reduced because the use of non-structures members as like curtain wall are decreased and large open space are in need for the service of buildings. Assembly and office buildings with a lower natural frequency have a higher possibility of experiencing excessive vibration induced by human activities as like jumping, running and walking. These excessive vibration make the occupants uncomfortable and the serviceability deterioration. The common method of application of walking loads for the vibration analysis of structures subjected to walking loads is to inflict a series unit walking load and a periodic function at a node. But this method could not consider the moving effect of walking. In this study, natural frequency and damping ratio of plate structure are evaluated by heel drop tests. And new application of equivalent walking loads are introduced for vibration analysis of real slab system subjected to walking loads. The response obtained from the numerical analysis are compared well to the results measured by experimental tests. It is possible to efficiently analyze the vibration of floor which is subjected to walking loads by applying equivalent walking loads.

  • PDF

Management of Design and Construction Information of Building Structures Based on IFC (IFC기반 건축물 골조설계 및 시공정보 유통)

  • Park, Chan-Ho;Kim, Chee-Kyeong
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2010.04a
    • /
    • pp.533-536
    • /
    • 2010
  • 현재 우리나라 건설 사업에는 BIM의 관심과 사용이 급증하고 있다. BIM의 현주소는 실무에 적용하기 어려운 단점이 많고 IFC를 이용한 정보호환에 어려움이 많다. 결과적으로 Architectural BIM Tool에서 모델링한 프로젝트를 Structural BIM Tool에서 다시 모델링을 하고 MEP단계에서도 다시 한 번 더 BIM 모델링을 하는 반복 작업과 반복 작업으로 인한 인력손실과 프로그램간의 유통과 호환에 문제가 많은 것이 현 실정이다. 이에 본 연구는 타 분야와의 정보 공유를 설계단계에 따라 상세 수준별로 분류하여 설계/설비 분야와 정보를 공유하고 물리적 모델과 해석적 모델의 상이로 인하여 현 정보 교류에 많은 문제점이 있어 두 모델간의 정보변환을 위한 알고리즘을 개발하고 구현하였다.

  • PDF

Influence of Incidence Direction of Seismic Wave on the Probabilistic Seismic Fragility Assessment of Bridges (교량의 확률론적 지진취약도에 대한 지진파의 입사방향성의 영향)

  • Sina Kong;Yeeun Kim;Sinith Kung;Jiho Moon;Jong-Keol Song
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.37 no.3
    • /
    • pp.151-162
    • /
    • 2024
  • As the incidence direction of ground motion (or seismic wave) changes, the seismic response of the structure will also change according to that direction. In order to analyze the effect of the seismic response of the example bridge according to the direction of incidence of ground motion, the acceleration response spectra (Sa-T1) corresponding to the 1-second period obtained for various angles of incidence were obtained. Using Sa-T1, 40 sets of orthogonal pairs of horizontal component seismic waves corresponding to 5 types of percentiles were generated. Seismic vulnerability analysis of the bridge piers was performed by obtaining the seismic response of an example bridge according to the direction of incidence of ground motion. By analyzing the seismic vulnerability analysis of seismic waves corresponding to five types of percentiles, it was found that the median value of the seismic vulnerability curve differs by about 1.2 to 2.6 times depending on the incident direction of the seismic wave. In other words, depending on the incidence direction of seismic waves, the degree of damage to the bridge structure can vary by about 1.2 to 2.6 times.

Analytical Performance Evaluation of Structure Reinforced with HRS Damper (고감쇠고무와 강재슬릿의 복합 댐퍼로 보강한 건축물의 해석적 성능평가)

  • Kim, Yu-Seong;Lee, Joon-Ho
    • Journal of Korean Association for Spatial Structures
    • /
    • v.22 no.4
    • /
    • pp.31-38
    • /
    • 2022
  • In this study, an incremental loading test of the HRS(Hybrid Rubber Slit) damper was additionally performed to define the physical characteristics according to the incremental test results, and an analytical study was performed according to the damping design procedure by selecting an example structure. As a result of performing seismic performance evaluation before reinforcement by selecting a RC structure similar to an actual school structure as an example structure, the story drift ratio was satisfied, but some column members collapsed due to bending deformation. In order to secure the seismic performance, the damping design procedure of the HRS damper was presented and performed. As a result of calculating the amount of damping device according to the expected damping ratio and applying it to the example structure, the hysteresis behavior was stable without decrease in strength, and the story drift ratio and the shear force were reduced according to the damping effect. Finally the column members that had collapsed before reinforcement satisfied the LS Level.