• Title/Summary/Keyword: 건축물에너지 평가

Search Result 150, Processing Time 0.027 seconds

Study on the Fire Suppression by Heat Transfer of Thermal Insulation Materials (건축물 외단열재의 열전달평가를 통한 화재 억제 방안 연구)

  • Ryu, Hwa Sung;Shin, Sang Hun;Song, sung young;Kim, Deuck Mo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.277-278
    • /
    • 2018
  • Improvement of insulation performance of buildings is a major part. Adiabatic method The adiabatic method minimizes the heat loss of the building. External insulation uses insulation to prevent fire. Ambient air hazards are less prone to fire. When a fire occurs, a phenolic pattern is formed and bond strength with the wall increases. EPS insulation and phenol foam were used to compare external heat transfer and external heat transfer. The heat transfer properties of phenolic foam and styrofoam were evaluated as follows. In the mortar and styrofoam structure, the problem of styrofoam reaching the burning point occurred before the collapse of the mortar, and the phenol foam had a problem in that when the direct fire was continued on the phenol foam. The characteristics of continuous infiltration appeared. In the case of mortar and phenol foam + styrofoam, the heat penetrated into the interior due to the shrinkage due to the shrinkage of the carbon screen on the phenol foam. However, when reinforced with glass mesh on the outer surface, And to reduce infiltration.

  • PDF

Seismic Performance Evaluation of R/C Different Floor Type Interior Beam-Column Joints in the Middle and High-rise Mixed-use Residential Building (중.고층 주상복합 R/C 건축물의 단차형 내부 보-기둥 접합부 내진성능평가)

  • Ha, Gee-Joo;Shin, Jong-Hak;Huh, Mean-Haeng;Hong, Kun-Ho;Ha, Jae-Hoon;Nam, Young-Sik
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.453-454
    • /
    • 2009
  • In this dissertation, experimental program was carried out to study the hysteretic behavior of the reinforced different floor type interior beam-column joint repeated cyclic loads under seismic actions. The test results was as follow. The reinforced interior beam-column joint, designed by the different floor type, was increased energy dissipation capacity and maximum load carrying capacity according to the increase of different floor in comparison to standard specimen. And it was also dissimilar to failure mode adjacent to joint region. energy dissipation capacity of each specimen, designed by the different floor type, was increased 1.1${\sim}$1.35 times in comparison to standard specimen.

  • PDF

Analysis of input factor variability for scenario analysis of urban water resource real-time cyper physical system simulator (도시수자원 실시간 사이버물리시스템 시뮬레이터의 시나리오 분석을 위한 입력인자 변동성 분석)

  • Yoo, Do Guen;Chung, Gunhui;Ok, Wonsu;Jun, Hwandon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.381-381
    • /
    • 2022
  • 본 연구에서는 실시간적으로 계측, 수집된 자료를 이용하여 도시지역 물순환 전 과정에 대한 개별 물리모델 구동을 실시하고, 수자원의 양적인 흐름을 연계하여 표출하는 도시 수자원 사이버 물리시스템(CPS) 시뮬레이터에 활용되는 입력인자 변동성 분석을 실시하였다. 도시 수자원 실시간 CPS 시뮬레이터의 시나리오 분석을 위한 변동입력인자는 취수량, 타 배수지 구역 공급량, 대상지역 수용가 사용량 변화, 오수전환률 및 오수배출 지연시간 등으로 설정하였으며, 변동입력인자 변화모의를 위한 발현가능한 시나리오를 구축하고, 분석결과를 정량화하여 제시하였다. 본 연구에서 활용된 발현가능한 시나리오는 가뭄 등 취수제한상황에 따른 양적인 공급 흐름모의, 수용가 물 사용 패턴 변화(예, 코로나로 인한 비대면 재택 근무 증가 등)에 의한 상수, 오수변화량 모의 등으로 설정되었다. 분석 결과 다양한 입력인자의 변화에 따른 도시수자원 흐름변화에 영향을 주는 구성요소의 파악과 정성, 정량적 영향을 직관적, 정량적으로 평가할 수 있음을 확인하였다. 도출된 변동성 평가 결과는 설정된 시나리오가 현실화될 경우 효과성 높은 대응책을 마련하는데 활용이 가능하다.

  • PDF

A Study on the Calculation Process of Carbon Dioxide Emission for Buildings with Life Cycle Assessment (건축물 생애과정에서의 이산화탄소 배출량 계산 프로세스에 관한 연구)

  • Jeong, Young-Sun;Huh, Jung-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.1
    • /
    • pp.23-30
    • /
    • 2011
  • International cooperation to reduce greenhouse gas emissions is expected to provide a big crisis and a great opportunity at the same time for our industry that heavily consumes energy. To cope actively with the international environmental regulation, such as the Framework Convention on Climate Change, quantitative measurement of the volume of greenhouse gases emitted by various industries and quantitative prediction of the greenhouse gas emissions of the future are becoming more important than anything else at the national level. This study aims to propose the calculation process of carbon dioxide($CO_2$) emission for building in life cycle. This paper describes and compares 9 different tool for environmental load estimation with LCA. This study proposed the calculation process for quantitatively predicting and assessing $CO_2$ emissions during the life cycle of buildings based on the life cycle assessment(LCA). The life cycle steps of buildings were divided into the design/supervision, new construction, repair, renovation, use of operating energy in buildings, maintenance, and reconstruction stage in the life cycle inventory analysis and the method of assessing the environmental load in each stage was proposed.

A Case Study on Energy Performance Analysis of Retrofitted Building Using Inverse Model Toolkit (Inverse Model Toolkit을 이용한 리모델링 건축물의 에너지 성능평가 사례)

  • Kwon, Kyung-Woo;Lee, Suk-Joo;Park, Jun-Seok
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.8
    • /
    • pp.394-400
    • /
    • 2014
  • Several models and methods have been developed to verify the improvement of energy performance in retrofit buildings. The verification is important to confirm the effectiveness of new technologies or retrofits. Inverse model toolkit proposed by ASHRAE evaluates the changes of the energy performance of retrofit buildings by using actual energy consumption data. In this study, the inverse model toolkit was used to analyze heating and cooling energy performance of an office building. Analyzed coefficients of correlation of actual energy consumption with estimated energy consumption was above 0.92 and well fitted. It was confirmed that energy consumption of natural gas decreased by 43.4% and also that electricity decreased by 13.8%, after the retrofit of the case building. For the energy usage, cooling energy was increased by 7.4%, heating energy was decreased by 42.3%, hot water and cooking were increased by 3.4%, lighting and electronics were decreased by 19.3%, and the total energy was decreased by 18.9%.

Rock Bolt Integrity Assessment in Time-Frequency Domain : In-situ Application at Hard Rock Site (유도파를 이용한 시간-주파수 영역 해석을 통한 록볼트 건전도 실험의 경암지반 현장 적용성 평가)

  • Lee, In-Mo;Han, Shin-In;Min, Bok-Ki;Lee, Jong-Sub
    • Journal of the Korean Geotechnical Society
    • /
    • v.25 no.12
    • /
    • pp.5-12
    • /
    • 2009
  • As rock bolts become one of the main support systems in tunnels and underground structures, the integrity of the rock bolts affects the safety of these structures. The purpose of this study is the evaluation of rock bolt integrity using wavelet transforms of the guided ultrasonic waves by using transmission test in the field. After several rock bolts with various defect ratios are embedded into a large scale concrete block and rock mass, guided waves are generated by a piezo disk element and measured by an acoustic emission (AE) sensor. The captured signals are analyzed in the time-frequency domain using the wavelet transform based on a Gabor wavelet. Peak values in the time-frequency domain represent the interval of travel time of each echo. The energy velocities of the guided waves increase with an increase in the defect ratio. The suitable curing time for the evergy velocity analysis is proposed by the laboratory test, and in-situ tests are performed in two tunnelling sites to verify the applicability of rock bolt integrity tests performed after proposed curing time. This study proves that time-frequency domain analysis is an effective tool for the evaluation of the rock bolt integrity.

Evaluation of Flexural Behavior of Masonry Members Reinforced with Engineered Cementitious Composite (고인성 복합체로 보강한 조적부재의 휨 거동 평가)

  • Yang, Seung-Hyeon;Kim, Sun-Woong;Kim, Jae-Hwan;Kang, Suk-Pyo;Hong, Seong-Uk
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.4
    • /
    • pp.37-45
    • /
    • 2021
  • This paper is a basic study to evaluate the possibility of earthquake-resistant reinforcement by reinforcing engineered cementitious composite in masonry members. In order to examine the performance according to the fiber mixing rate of the engineered cementitious composite, a test specimen was prepared according to the formulation design, and flow ability, compressive strength, flexural strength, length change rate, and direct tensile strain were measured. In addition, non-reinforced masonry members, masonry members reinforced with engineered cementitious composite, and masonry members in which glass fibers and wire mesh were separately reinforced with engineered cementitious composites were manufactured, and flexural strength and maximum displacement were measured. All specimens reinforced with engineered cementitious composite showed more than 16 times the effect of maximal strength compared to that of no reinforcement, and as a result of examining the crack shape, the energy dissipation ability was excellent, confirming the possibility of seismic reinforcement.

A Study on Estimating Recycling Potential of Demolition Waste Generated in End-of-Life of Buildings by Structural Type Considering Economic Efficiency (경제적 효율성 측면에서 건축물 구조를 고려한 해체폐기물의 재활용가능성에 관한 연구)

  • Cha, Gi-Wook;Kim, Jin Ho;Moon, Hyeun Jun;Kim, Young-Chan;Hong, Won-Hwa
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.36 no.4
    • /
    • pp.153-161
    • /
    • 2020
  • This study investigates the recycling potential of demolition waste (DW) according to building structure, while considering economic aspects. For that, this study surveyed 1,034 residential buildings to collect reliable information on demolition waste generation rates (DWGRs). This study suggested a method for operational cost calculation for each stage and carried out an inventory analysis. The economic value of recycled DW materials was also calculated. And then, the recycling potential(RP) was calculated by building structures and waste types. RP by building structure was low (27-40%), and RP was found in the order of masonry-block, wooden, RC and concrete-brick. By type of DWs, the RP of aggregates was considerably lower than 7%, and DWs such as wood, plastics, and metals showed more than 100% RP. Considering the results of this study, In order to improve the RP of buildings and DWs, the diversification of products that recycled waste like aggregates (i.e., mortar, concrete, bricks, blocks, tiles) and the development of high value-added products are considered to be the most urgent problems. Based on the above RP results, this study proposed a more advanced method for life cycle assessment of buildings and demolition waste.

Load-Displacement Relationship of Passive Vibration Units Composed with a Spring and Vibration-Proof Rubbers (스프링과 방진고무가 융합된 제진장치의 하중-변위 관계)

  • Mun, Ju-Hyun;Im, Chae-Rim;Wang, Hye-Rin;Yang, Keun-Hyeok
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.6
    • /
    • pp.226-234
    • /
    • 2021
  • The objective of this study is to establish the fundamental design data for axial load-displacement relationship under axial monotonic or cyclic responses of seismic damping·isolation (SDI) units developed for ceiling structures. The main parameters include the installation of a spring, the number of rubber layer, prestress stress of bolts for connector between the spring and rubbers, and loading type. Test results showed that SDI units with a spring in the core and higher prestress stress of bolts tended to be higher stiffness at the ascending branch and more ductile behavior at the descending branch. This trends more notable for the specimens under monotonic load rather than cyclic loads. Consequently, the energy dissipation of SDI unit can be optimally designed with the following conditions: installation of a spring within 3-layer rubbers and prestress applied to the bolts at 10% of their yielding strength . When compared with the experimental tension capacity of the developed SDI units, the predictions by JIS B 2704-1 and KDS 31 00 are conservative under monotonic loading but higher by approximately 10% under cyclic loading.

Evaluation of Shear Performance of RC Web Opening Beams According to the Shape of Web Opening Reinforcement (유공보강근의 형상에 따른 철근콘크리트 유공 보의 전단성능평가)

  • Kim, Min-Jun;Lee, Bum-Sik;Kim, Kil-Hee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.5
    • /
    • pp.76-85
    • /
    • 2021
  • In this study, a shear experiment was conducted to evaluate the structural performance of RC members according to the shape of web opening reinforcement. For a total of 4 RC members specimens, the main variables were with or without web openings, with or without web opening reinforcement, and shape of web opening reinforcement, respectively. In this study, a spiral web opening reinforcement with a mixture of square and octagonal shapes was proposed and compared with the existing band type. As a result of the experiment, the specimen with the proposed web opening reinforcement showed that the shear capacity and the energy dissipation capacity increased compared to other specimens. It was confirmed that the web opening reinforcement proposed in this study had a positive effect on the shear performance and crack control of RC members with web openings.