• Title/Summary/Keyword: 건축면적

Search Result 515, Processing Time 0.023 seconds

A Study on Architectural Planning Elements And Spatial Hierarchy of Kindergarten Attached to Elementary School - Focused on the Cases of Hwaseong, Gyeonggi Province - (초등학교 병설유치원의 건축계획요소 및 공간위계에 관한 연구 - 경기도 화성지역사례를 중심으로 -)

  • Kim, Hyoung-Soo;Park, Jae-Seung
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.22 no.4
    • /
    • pp.3-14
    • /
    • 2015
  • This study analyzes the domestic kindergarten attached to elementary school, and that is to present the basic data to be established in the future on the basis of the problems seen in kindergarten attached to elementary school analysis of construction planning. For this study, selecting 10 kindergartens in Hwaseong, Gyeonggi-do, and the selected spatial configuration of kindergarten. And then, analyzes Space Organization, Circulation Plan, Area Distribution, Spatial Hierarchy of them. The results were as follows. 1) The current kindergarten attached to elementary school is associated with the most elementary building planes are independent. 2) Most of them don't have space for secondary activities such as playroom or hallway space between the classrooms and the entrance. 3) Interior space is composed of educational space, service space, administrative space. 4) Kindergarten attached to elementary school should plan increase the area because it is small scale there are a lot of dead space. 5) The main users of kindergarten children should be planned simultaneously in a space that is used along with the teacher. Such a kindergarten attached to elementary school in order to be implemented in construction and environmental characteristics of the kindergarten curriculum developers and juxtaposition of kindergarten teachers and architects such exchanges should be made a doctor of the tripartite briskly.

Survey of actual status of ecological environment elements of certification schools of environment friendly architecture (친환경건축물인증학교의 생태환경요소에 대한 실태조사)

  • Song, Byung-joon;Cho, Jin-il
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.7 no.1
    • /
    • pp.39-55
    • /
    • 2008
  • The purpose of this study is to suggest improvement of certification standards of environment friendly architecture in ecological environment field by surveying and analyzing actual status of actual certification schools of environment friendly architecture per ecological environment elements through extracting ecological environment elements which is possible to analyze in quantity certification standards of environment friendly architecture. As contents of the study, first, certification as an examination on certification system of environment friendly architecture, summary of certification system of environment friendly architecture, ecological environment elements which is possible for quantitative analysis of ecological environment certification standards were extracted. Second, actual status of ecological environment elements per school grade, region, and population increase by collecting actual data of certification schools of environment friendly architecture. Third, using analysis data of ecological environment elements, ecological area ratio of certification schools of environment friendly architecture per weighted values of space types was calculated and the results were analyzed as the follows. (1) In case of preliminary certification out of total objects of investigation schools was average 34.06% but in this case of certification, it was reduced to 33.07%. However, it is difficult to make judgment as actual evidence data since ecological area ratio of actual preliminary certification is data based on drawing planes. Therefore, in case of this certification, elementary schools was investigated at average 33.11%, middle schools 34.81%, and high schools 31.28% and middle school showed the highest relatively. (2) Besides, average composition ratio of ecological area ratio was 63.04% in case of this certification regardless of school grade and region and it was analyzed that about 70% of ecological area ratio is composed of the natural based green area including pure natural based green land and 6.89% of ecological learning institute.

  • PDF

The Study on Appropriateness of Ergonomically Designed in Living Space of an Apartment Unit (아파트 주거공간의 인체공학적 적합성 연구)

  • Park, Byong-Gyu
    • Journal of Korean Association for Spatial Structures
    • /
    • v.9 no.4
    • /
    • pp.89-96
    • /
    • 2009
  • Apartment is the most favorite residential type which already occupies more than 50 percent of total number of housing unite in Korea. The interior space design shows various changes of trends within old and legal standard in terms of basic dimension. The most important function of housing means that Provides comfortable living spaces for a family and enjoying relaxation of stress form social activities. This residential space effects direct or indirect to each family members self-satisfaction and relationship. The basic factor for space design brings dimension which is enable space efficiency together with behavioral route, size of electronics and furnitures. Apartment dwelling type was introduced from out of countries. From the very beginning that inharmonious conflicts found and adjusted for several decades. But, the changes of body conditions of new generation has not considered as a dwelling space design yet. This research may call for attention of changing human scale standards for housing in various field of study.

  • PDF

Analysis characteristics of surface runoff rate of Nae-seong catchment at Nakdong River (낙동강 내성천유역의 표면유출비 특성분석)

  • Chang, Hyung Joon;Lee, Hyo Sang;Min, Byung Yun;Jo, Guk-Hui;Lee, Mu-Gyeong
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.440-440
    • /
    • 2015
  • 최근 급증하는 기후변화 영향으로 인한 자연재해의 위험이 증대되고 있다. 이러한 자연재해 중 가뭄은 그 빈도수나 피해의 규모가 홍수보다 작아 관련된 연구가 제한적이므로 유역의 특성을 반영한 장 단기 유출특성의 면밀한 검토가 요구되며, 향후 이를 반영한 홍수유출모형의 개발이 필요하다. 본 연구에서는 유역 수자원산정의 기초연구로서 낙동강 내성천 유역을 대상으로 유역의 유출수문자료를 구축하고 장기기저흐름지수(BFI: Base Flow Index), 표면유출지수(1-Base Flow Index)를 산정하여 유역의 유출특성을 분석하였다. 내성천유역은 낙동강 상류유역으로 본류길이는 110.69km, 유역면적은 $1,815.28km^2$이며, 분수계의 능선부가 대체로 1,000m이상의 고도를 나타내고, 유역분지의 평균 해발고도는 318.2m이다. 또한 영주댐이 검설 중에 있으며, 향후 댐 건설이 수자원에 끼치는 영향등을 분석 할 수 있는 유역이다. 본 연구에서는 내성천 유역을 분석하기 위해서 8개의 수위관측지점을 선정한 후, 2001년부터 2012년 기간의 일 유량자료를 바탕으로 유출비를 산정하였다. 내성천 8개 소유역의 유역 장기유출비를 분석한 결과 기저흐름지수는 0.24~0.47, 표면유출지수는 0.53~0.76의 분포를 나타내었다. 표면유출비는 미호(0.76), 월호(0.53), 점촌(0.71)유역을 제외한 5개 유역에서 0.62~0.65의 분포를 나타내었으므로 낙동강 상류인 내성천유역의 표면유출비로 0.63을 제시할 수 있을 것으로 판단된다. 향후 다수의 낙동강유역을 추가분석하여, 낙동강유역의 고유 유출특성을 제시 할 수 있을 것으로 기대된다.

  • PDF

Evaluation of Shear Performance of RC Web Opening Beams According to the Shape of Web Opening Reinforcement (유공보강근의 형상에 따른 철근콘크리트 유공 보의 전단성능평가)

  • Kim, Min-Jun;Lee, Bum-Sik;Kim, Kil-Hee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.5
    • /
    • pp.76-85
    • /
    • 2021
  • In this study, a shear experiment was conducted to evaluate the structural performance of RC members according to the shape of web opening reinforcement. For a total of 4 RC members specimens, the main variables were with or without web openings, with or without web opening reinforcement, and shape of web opening reinforcement, respectively. In this study, a spiral web opening reinforcement with a mixture of square and octagonal shapes was proposed and compared with the existing band type. As a result of the experiment, the specimen with the proposed web opening reinforcement showed that the shear capacity and the energy dissipation capacity increased compared to other specimens. It was confirmed that the web opening reinforcement proposed in this study had a positive effect on the shear performance and crack control of RC members with web openings.

A Study on Improvement of Evacuation Safety Evaluation for Performance Based Design in Underground Parking Lot (지하주차장 성능위주설계의 피난안전성 평가 개선에 관한 연구)

  • Song, Young-Joo;Kong, II-Chean;Kim, Hak-Jung
    • Fire Science and Engineering
    • /
    • v.33 no.2
    • /
    • pp.85-97
    • /
    • 2019
  • Today, building constructions are becoming larger, higher, deeper, and complex to improve quality of human life and meet various needs. As a result, new design space for non - typically standardized space has been created, and targets for performance-based design are also becoming increased. An evacuation safety evaluation of performance-based design should be compared with ASET and RSET estimation so that the value of RSET does not exceed the value of ASET. However, there is a problem that it is difficult to secure the safety with using the performance-based design evaluation method currently in use, especially in case of the underground parking lot, because it has wide compartment area and various routes for evacuation. Therefore, in order to overcome these problems, this paper first investigates the simulation setting method of the performance-based design that is currently in use, and then conducts two fire simulations and three evacuation simulations for underground parking lots each time, so performs the evacuation safety evaluationin total six cases of situations. Here this paper analyzes the problem with comparative evaluation research and suggests the better solution for improved evacuation safety evaluation of performance-based design.

Comparing Water Management Categories of Green Building Rating Systems for Development of Evaluation Criteria of Watersheds (유역 평가 기준 개발을 위한 그린빌딩 평가 시스템의 물관리 관련 항목 비교 연구)

  • Idrees, Muhammad Bilal;Lee, Jin-Young;Ahn, Jae-Hyun;Kim, Tae-Woong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.38 no.6
    • /
    • pp.1013-1020
    • /
    • 2018
  • With the rapid industrialization and increase in population, more and more people are moving to live in cities. This urbanization trend is resulting in increased construction and development activities which associates with escalation of impervious surface. This in turn causes problems like groundwater depletion, higher flood peaks, and increased rate of soil loss from the watershed. Watershed management projects are being implemented around the globe concerning with the application of soil and water resources conservation practices. It is desirable that an entire watershed be evaluated based on soil and water conservation practices applied. In this study, water management categories of green building rating systems (GBRS) of South Korea, Taiwan, and the Philippines were discussed. The water management practices rating criteria of G-SEED (South Korea), BERDE (Philippines), and EEWH (Taiwan) were explored and compared. The insights of this study are expected to be projected to establish a comprehensive rating system for the evaluation of watersheds. The quantification of watershed management practices will help future planners to identify areas of potential water-related risks and counter the hazards more effectively.

Numerical Investigation on Fire of Stage in Theater: Effects of Natural Smoke Vent Area and Fire Source Location (공연장 무대부 화재에 대한 전산해석 연구: 자연 배연구 면적과 화원 위치 영향)

  • Park, Min Yeong;Lee, Chi Young
    • Journal of the Korean Society of Safety
    • /
    • v.37 no.1
    • /
    • pp.1-11
    • /
    • 2022
  • This numerical study investigates the effects of the size of the natural smoke vent area (10% and 1% of the floor area) and the location of the fire source (i.e., at the side and center of the stage) on the temperature distribution in the compartment and velocity distribution and mass flow rate of flow through a natural smoke vent for a reduced-scale model of a theater stage. Then, the mass flow rate of outflow through the natural smoke vent in the event of a fire for a real-scale theater stage was examined. The case with the larger natural smoke vent area and central fire source location showed lower temperature distributions and higher mass flow rates of outflow and inflow than the case with the smaller natural smoke vent area and side fire source location. The trends of the temperature distributions were closely related to those of the mass flow rates for the outflow and inflow. Additionally, the case with the larger natural smoke vent area and central fire source location exhibited the most non-uniform flow velocity distribution in all cases tested. A bidirectional flow, in which the outflow and inflow occur simultaneously, was observed through the natural smoke vent. In the event of a fire situation in a real-scale theater stage, it was predicted that the case with the larger natural smoke vent area and central fire source location would have a mass flow rate of outflow that is 43.53 times higher than that of the case with the smaller natural smoke vent area and side fire source location. The present results indicate that the natural smoke vent location should be determined by considering the location in a theater stage where a fire can occur.

An Analysis of the Key Factors Affecting Apartment Sales Price in Gwangju, South Korea (광주광역시 아파트 매매가 영향요인 분석)

  • Lim, Sung Yeon;Ko, Chang Wan;Jeong, Young-Seon
    • Smart Media Journal
    • /
    • v.11 no.3
    • /
    • pp.62-73
    • /
    • 2022
  • Researches on the prediction of domestic apartment sales price have been continuously conducted, but it is not easy to accurately predict apartment prices because various characteristics are compounded. Prior to predicting apartment sales price, the analysis of major factors, influencing on sale prices, is of paramount importance to improve the accuracy of sales price. Therefore, this study aims to analyze what are the factors that affect the apartment sales price in Gwangju, which is currently showing a steady increase rate. With 6 years of Gwangju apartment transaction price and various social factor data, several maching learning techniques such as multiple regression analysis, random forest, and deep artificial neural network algorithms are applied to identify major factors in each model. The performances of each model are compared with RMSE (Root Mean Squared Error), MAE (Mean Absolute Error) and R2 (coefficient of determination). The experiment shows that several factors such as 'contract year', 'applicable area', 'certificate of deposit', 'mortgage rate', 'leading index', 'producer price index', 'coincident composite index' are analyzed as main factors, affecting the sales price.

A Study on the Urban Spatial Policy for the Industrial Cities in Abandoned Mining Area Through the Analysis of the Actual Condition of Urban Shrinkage - A Case Study on Shrinking Cities in Abandoned Mining area by the Coal Industry Rationalization Policy (폐광지역 산업도시의 도시축소양상과 도시공간정책방안에 관한 연구 -석탄산업합리화조치에 따른 폐광지역 축소도시에 대한 사례 연구)

  • Chi, Eun Hee;Han, Dong Gyu;Jeoung, Chan Gu;Kang, Jun Mo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.42 no.1
    • /
    • pp.135-144
    • /
    • 2022
  • This paper aimed to analyze the type of urban shrinkage over the past 20 years for four case cities designated as abandoned mining area promotion zones and present the direction of future urban spatial policies through the analysis of shrinking status. According to the analysis of urban shrinkage in the past 20 years, all of the case cities were analyzed as fixed-type shrinking cities, showing a population decrease of more than 30% over the past 40 years compared to the peak population. Despite the decrease in population, the designated area of urbanization and non-urban areas is increasing every year, and the development permit and construction permit in non-urban areas are also increasing, requiring efficient management and operation of urban space. It is necessary to study military-level cities in the high-risk phase of extinction in the future, and to develop various indicators for segmentation of urban shrinkage types and analysis of status by type.