• 제목/요약/키워드: 건조층

검색결과 427건 처리시간 0.03초

건조 조건하에서 TEDA주입 탄소층에 의한 Methyliodide 제거 효율에 관한 연구 (Study on the Removal Efficiency of a TEDA Impregnated Charcoal Bed for Methyliodide under Dry Condition)

  • Won Jim Cho;Soon Heung Chang
    • Nuclear Engineering and Technology
    • /
    • 제16권2호
    • /
    • pp.80-88
    • /
    • 1984
  • Thriethylenediamine(TEDA)주입 활성탄층에 의한 공기중의 methyliodide 제거 메카니즘이 조사되었다. 실험 결과, 공기 유속이 20cm/sec 이상일 때는 기공확산이 율속 단계였으며, 10cm/sec 일때는 기공확산 저항과 외부 물질 전달 저항이 모두 총괄 물질 전달 저항에 기여하였다. 공기중 수증기가 존재하지 않는 건조 조건하에서의 TEDA 함침 탄소층의 성능을 묘사하기 위한 흡착 모델이 제안되었다. 계산된 값은 실험 결과와 잘 일치하였다.

  • PDF

농산물의 유동층 건조특성 연구 - 파 및 앙파의 유동층 건조특성 - (Study on the Drying Characteristics of Agricultural Products During Fluidized Bed Drying - Drying Characteristics of Green Onion and Onion During Fluidized Bed Drying -)

  • 이귀현
    • Journal of Biosystems Engineering
    • /
    • 제31권5호
    • /
    • pp.416-422
    • /
    • 2006
  • Drying characteristics of green onion and onion during fluidized and fixed bed drying were investigated and compared. Sliced peen onion and onion were dried at drying air temperature of 45, 55, and $65^{\circ}C$. Drying air velocity during fluidized bed drying was adjusted with drying time at each drying temperature. Drying time to reach a given final moisture content was shorten in fluidized bed drying than in fixed bed drying - for drying temperature of 45, 55, and $65^{\circ}C$, the differences were 60, 60, and 50 min for green onion and 360, 180, and 60 min for onion. Drying constant (K) was greatly affected by drying method and drying temperature. Terminal velocity under fluidized bed drying was decreased exponentially for green onion and linearly (or onion with increase of drying temperature. Also, terminal velocity had linear relationship with moisture content for both green onion and onion.

시공단계를 고려한 콘크리트 프레임 구조물의 해석 (Analysis of Concrete Frame Structures Considering the Construction Sequences)

  • 곽효경;서영재
    • 한국전산구조공학회논문집
    • /
    • 제12권2호
    • /
    • pp.171-184
    • /
    • 1999
  • 이 논문은 시공단계를 고려한 콘크리트 프레임 구조물의 거동 해석을 다루고 있다. 고층건물의 경우 하루에 시공이 완료되지 않으므로 각 시공단계에 따라 콘크리트의 시간의존적 현상은 다르게 발생된다. 이를 위하여 이 논문에서는 일반적인 프레임 해석기법에 콘크리트의 시간의존적 특성을 고려하였다. 이 연구에 도입된 해석기법은 단면을 가상의 층으로 나누고 각층은 일축상태로 가정한 적층단면을 사용하였다. 요소는 평면 보요소를 사용하였으며 강성행렬은 변위법을 바탕으로 유도하였고 전체적인 구조해석은 비선형 구조해석 방법의 하나인 복합법을 사용하였다. 콘크리트의 시간의존적 특성을 고려하기 위하여 단면의 각 층에서 크리프와 건조수축에 의한 변형률을 계산하였으며 크리프는 크리프 Compliance의 전개에 기본을 둔 1차 순환적 단계 알고리즘을 사용하였다. 끝으로 이 연구에서 제안된 해석모델을 이용하여 프레임해석 및 기둥축소에 관한 예제를 해석하였다.

  • PDF

f-k 분석에 의한 레이다파 속도 측정 및 레이다파의 분산성 가이드 현상을 이용한 지하 물성 계산 (Measurement of GPR Direct Wave Velocity by f-k Analysis and Determination of Dielectric Property by Dispersive Guided Wave)

  • 이명종;;김정호
    • 지구물리와물리탐사
    • /
    • 제9권4호
    • /
    • pp.304-315
    • /
    • 2006
  • 지표 천부 불포화대의 특성화에서 중요한 토양수분함량의 측정을 위한 GPR 탐사에서 지중 직접파 측정 자료의 f-k 분석을 이용한 레이다파 속도 측정법의 응용성을 검토하였다. 상부 토양이 하부에 비하여 건조한 경우에는 f-k 스펙트럼 상에서 대부분의 에너지가 공기층과 건조 토양의 속도로 이루어지는 영역 내에 존재하며, 고주파수 자료를 이용하여 비교적 정확하게 상부층의 속도를 획득할 수 있었다. 이에 비하여 천부 토양층이 하부에 비하여 수분 함유량이 높은 조건하에서는 대부분의 에너지가 건조토양과 습윤토양의 속도로 형성되는 영역 내에 분포하고 있으며, 특히 이 경우 레이다파는 습윤 토양층을 통하여 비손실성으로 전파하는 레이다파의 분산성 가이드 현상을 나타내었다. 이와 같은 가이드 현상은 모드 전파이론으로 설명되며, 이 연구에서는 이를 이용하여 2층 층서구조의 각 층의 유전율과 층의 두께를 정확히 계산할 수 있는 역산 알고리듬을 개발하였다. FDTD 수치모델링 자료에 f-k 분석을 적용하여 속도분산곡선을 획득하고 이 자료에 개발된 역산 알고림듬을 적용함으로써 두층의 유전율과 두께를 정확하게 계산할 수 있었으며, 특히 역산 시 고차 모드를 포함함으로써 그 정확도를 향상시킬 수 있었다. 향후 비슷한 조건을 가지는 현장에 개발된 알고리듬을 적용하여 정량적인 전기적 물성을 획득할 수 있을 것으로 기대된다.

수산식품의 건조방법에 관한 연구 1 . 오정어의 고정층건조 (Studies on the Drying Methods of Sea Foods 1 . Fixed Bed Drying of Squid)

  • 허종화
    • 한국수산과학회지
    • /
    • 제15권1호
    • /
    • pp.107-110
    • /
    • 1982
  • Fixed bed drying method was selected to reduce the initial drying time of squid and the effects of drying air temperature and bed height on the drying rate were investigated, with following results. 1. The drying rate in the fixed bed dryer was faster than that of natural convection type dryer heated indirectly and that of hot air dryer heated directly. 2, Shirai-equation was applicable to squid being dried. Using the equation, drying rate constant obtained was as shown in table 1.

  • PDF

무중력 유동층 건조기 개발에 관한 연구 (The Study on the Development of The Non-Gravity Fluidized Dryer)

  • 김석철;배동규;한지웅;금성민;이창언
    • 대한기계학회논문집B
    • /
    • 제24권9호
    • /
    • pp.1195-1209
    • /
    • 2000
  • The purpose of this study is to develop the non-gravity fluidized dryer. In this non-gravity fluidized dryer the fluidized zone is produced by two paddles in mixer, which maximizes the surface area of materials and then heated air through the guiding panels dehumidify them. This can conduct the drying process quickly and control moisture contents to lower limits. The ventilation system is closed loop system, which can be changeable to open system, and can be used as a multi-purposed dryer in which mixing, drying, granulating and cooling process is conducted. In order to develop the non-gravity fluidized dryer, in the first fundamental experiments were performed to mixing accuracy and then the other parts of dryer and control system were examined to check whether they were designed properly and operated harmoniously with mixer. Also the preparatory experiments were fulfilled to examine the efficiency and reliability of the dryer. Lastly, on the basis of preparatory experiments, performance test for the non-gravity fluidized dryer carried out for the variation of the initial moisture contents, desired moisture contents, heated air velocity and heating temperature.

건조방법과 온도변화에 따른 감 분말의 흡습특성 (Absorption Characteristics of Persimmon Powder Depending on Temperature Changes and Drying Methods)

  • 이원영;김종국
    • 동아시아식생활학회지
    • /
    • 제11권6호
    • /
    • pp.479-484
    • /
    • 2001
  • 감 과육 파쇄물을 열풍, 진공, 동결의 건조방법으로 건조를 행하였다. 각 건조 방법별로 감분말의 물리적 특성치인 공극률은 열풍 건조한 시료가 1.9%로 가장 작게 나타났으며, 진공건조 2.13%, 동결건조가 3.95%의 순으로 나타났다. 또한 총공극 면적 역시 동결, 진공. 열풍건조의 순으로 나타났으며 공극의 평균지름은 반대의 순으로 나타났다. 상대습도의 변화에 따른 감 분말의 평형수분함량에 도달하는 기간을 조사한 결과이다. 상대습도가 증가할수록 흡습량이 증가하는 것으로 나타났으며 저장 3일을 기점으로 그 이전에는 흡습량이 급격히 증가하다가 그 이후에는 증가폭이 둔화하는 것으로 나타났다. 또한 낮은 상대습도에서는 수분평형상태에 도달하는 시간이 짧은 반면 상대습도가 증가할수록 평형수분함량에 도달하는 시간이 길어지는 경향을 나타내었다. 온도의 변화에 있어서는 저장온도가 증가할수록 평형상태에 이르는 시간이 길어졌으며 저장상대습도에 따른 평형수분함량의 도달시간은 실험구간내 에서의 상대습도변화에서는 5일 정도에서 평형상태에 거의 다다르는 것으로 나타나 저장 적정 수분함량을 구하기 위해 단분자층 수분함량을 구한 결과는 BET식에서 동결건조한 시료가 다른 시료보다 높은 값을 나타내었고, 등온 흡습선으로서 적합도는 건조 방법별로 0.95 이상의 상관계수 값을 나타내었다.

  • PDF

알긴산 나트륨을 이용한 유산균 캡슐화의 상업화 공정 개발 (Development of a Commercial Process for Micro-Encapsulation of Lactic Acid Bacteria Using Sodium Alginate)

  • 김지연;유성식
    • Korean Chemical Engineering Research
    • /
    • 제55권3호
    • /
    • pp.313-321
    • /
    • 2017
  • 바이오 고분자인 알긴산 나트륨(Sodium Alginate)을 이용하여 기존의 방법에 비해 생산성이 우수한 캡슐화의 상업화 공정을 개발하고자 하였다. 또한, 동일 공정으로 키토산을 알긴산과 함께 캡슐화하여 알긴산 나트륨으로 캡슐화 된 유산균과 비교하였다. 유산균 캡슐화의 상업화 공정의 주요 공정은 캡슐화 후 기존의 동결건조 대신에 본 연구진이 개발한 생산성이 우수한 유동화 건조 방법에 의하여 건조시간을 15~24이상 단축할 수 있었지만, 생균수는 동결건조와 유동층 건조의 비율이 1:0.75로 동결건조 방법이 좋았다. 하지만 건조에 드는 비용과 시간을 고려 해 볼 때 유동층 건조 방법으로 상업화 공정이 가능함을 확인할 수 있었다. Chitosan-alginate 캡슐은 알긴산 칼슘캡슐과 생균수를 비교하였을 때, 알긴산을 이용한 캡슐은 희석배수 $10^{-9}$, 즉 약 $1{\times}10^9$ 마리 이상의 균이 존재하고, 키토산을 이용한 캡슐은 희석배수 $10^{-3}$, 즉 약 $1{\times}10^3$ 마리의 균이 존재함을 확인 할 수 있었다. 본 연구의 기술로 제조된 유산균 캡슐은 pH 4.65, 6.01에서 96시간 이상 동안 안정하였지만, pH 7.07, 8.35에서는 1시간 이내에 모두 붕해되었다. 이는 유산균 캡슐이 위산에서 안정성을 보이고 pH 7이상을 띠는 소화기관인 소장과 대장에서는 쉽게 붕해가 일어날 수 있음을 알 수 있었다.

연료전지 다공성막을 통한 수분증발량의 정량적 측정에 관한 실험적 연구 (Development of System for Measuring Evaporation Rate through Porous Medium in Fuel Cells)

  • 김종록;김무환;손상영
    • 대한기계학회논문집B
    • /
    • 제36권6호
    • /
    • pp.579-582
    • /
    • 2012
  • 연료전지 시스템에서 잔류 수분의 제거과정은 연료전지의 성능 및 수명 관리를 위해 중요한 과정이다. 효과적인 수분 제거과정의 설계를 위해서는 연료전지내의 수분 제거 특성에 대한 이해가 필수적이다. 이를 위해 본 연구에서는 연료전지의 다공성막인 가스확산층을 통한 수분증발량을 정상상태에서 측정하는 실험 기법을 개발하였다. 이 기법을 이용하여 연료전지의 잔류수분 제거 현상을 모사하는 실험장치를 개발하였다. 그리고 건조가스와 가스확산층의 변수가 수분에 미치는 영향을 실험적으로 측정하였다. 건조가스의 습도가 낮고, 유량이 높을수록 가스확산층을 통해 증발되는 수분량이 높았다. 또한 가스확산층의 두께가 얇을수록 수분 증발량이 높은 특성을 확인하였다.

연소전 $CO_2$ 포집용 분무건조 고체 흡수제의 물성 및 $CO_2$ 흡수 특성 (Characteristics of Solid Regenerable $CO_2$ sorbents for Pre-combustion $CO_2$ Capture)

  • 백점인;류정호;이중범;엄태형;김지웅;전원식;류청걸
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 춘계학술대회 초록집
    • /
    • pp.110.2-110.2
    • /
    • 2010
  • 현재 상용가능한 연소전 $CO_2$ 포집 기술은 습식 스크러빙 방식으로 고온의 합성가스를 상온 수준으로 온도를 낮춘 후 $CO_2$를 포집해야 하고 포집된 $CO_2$의 압력이 낮아 재압축하여 저장소로 보내야 함에 따라 큰 폭의 열효율 손실이 불가피하다. 고온 고압에서 이산화탄소를 포집할수 있는 고체 흡수제를 이용할 경우 이산화탄소 포집 치 저장 추가에 따른 시스템 효율 저하를 최소화할 수 있다. 고체 $CO_2$ 흡수제는 서로 연결된 두 개의 유동층 반응기를 순환하면서 흡수탑에서는 합성가스 중의 $CO_2$를 흡수하고 재생탑에서는 고온의 수증기와 접촉하여 흡수된 $CO_2$를 다시 배출함으로써 재생된다. 따라서 건식 재생 $CO_2$ 흡수제는 유동층 공정에 응용가능한 물성과 함께 높은 $CO_2$ 흡수능과 빠른 반응성이 요구된다. 본 연구에서는 유동층 공정에 적합한 물성을 가진 연소전 $CO_2$ 포집용 고체 흡수제를 분무건조법으로 제조하였으며, 모사 합성가스를 이용하여 열중량분석기와 기포유동층반응기를 이용하여 $200^{\circ}C$ 흡수, $400^{\circ}C$ 재생, 압력 20 bar 조건으로 반응성을 측정하였다. 개발된 고체 $CO_2$ 흡수제는 열중량분석기에서는 반응 후 10-13 wt%의 무게증가를 나타내었고 기포유동층반응기에서는 8-10 wt%의 $CO_2$ 흡수능을 보여주었다. 특히 수증기의 함량이 10% 이상에서 높은 흡수능을 나타내어 수증기가 반응에 크게 작용하고 있음을 알 수 있었다.

  • PDF