• Title/Summary/Keyword: 건전성

Search Result 2,342, Processing Time 0.029 seconds

Structural Evaluation on HIC Transport Packaging under Accident Conditions (HIC 운반용기의 사고조건에 대한 구조평가)

  • Chung Sung-Hwan;Kim Duck-Hoi;Jung Jin-Se;Yang Ke-Hyung;Lee Heung-Young
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.3 no.3
    • /
    • pp.231-236
    • /
    • 2005
  • HIC transport packaging to transport a high integrity container(HIC) containing dry spent resin generated from nuclear power plants is to comply with the regulatory requirements of Korea and IAEA for Type B packaging due to the high radioactivity of the content, and to maintain the structural integrity under normal and accident conditions. It must withstand 9 m free drop impact onto an unyielding surface and 1 m drop impact onto a mild steel bar in a position causing maximum damage. For the conceptual design of a cylindrical HIC transport package, three dimensional dynamic structural analysis to ensure that the integrity of the package is maintained under all credible loads for 9 m free drop and 1 m puncture conditions were carried out using ABAQUS code.

  • PDF

Seismic Evaluation for Strainer in the Primary Cooling System (일차 냉각계통 스트레이너에 대한 내진 건전성 평가)

  • 정철섭
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.13 no.3
    • /
    • pp.295-304
    • /
    • 2000
  • To evaluate the structural integrity for the strainer under seismic loading the seismic analysis and design were performed for T-type strainer in accordance with ASME, Section Ⅲ, Class 3(ND). Since there are no specified design requirements for the strainer in ASME Code, the strainer body was analysed according to ND-3500, valve design. Flanged joints connected with PCS piping were designed according to ND-3658.3. And the criteria for the cover flange was governed by the Appendix XI. Both a frequency analysis and an equivalent static seismic analysis of the strainer were carried out using the finite element computer program, ANSYS. The frequency analysis results show the fundamental natural frequency is greater than 33Hz, thus justifying the use of the equivalent static analysis through which membrane and bending stresses are obtained in the critical points near the branch connection area. The results of the seismic evaluation fully satisfied with the structural acceptance criteria of the ASME Code. Accordingly the structural integrity on the strainer body and flanges were proved.

  • PDF

Evaluation of Creep-Fatigue Integrity for High Temperature Pressure Vessel in a Sodium Test Loop (소듐 시험루프 내 고온 압력용기의 크리프-피로 건전성 평가)

  • Lee, Hyeong-Yeon;Lee, Dong-Won
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.8
    • /
    • pp.831-836
    • /
    • 2014
  • In this study, high temperature integrity evaluation on a pressure vessel of the expansion tank operating at elevated temperature of $510^{\circ}C$ in the sodium test facility of the SEFLA(Sodium Thermal-hydraulic Experiment Loop for Finned-tube Sodium-to-Air heat exchanger) to be constructed at KAERI has been performed. Evaluations of creep-fatigue damage based on a full 3D finite element analyses were conducted for the expansion tank according to the recent elevated temperature design codes of ASME Section III Subsection NH and French RCC-MRx. It was shown that the expansion tank maintains its integrity under the intended creep-fatigue loads. Quantitative code comparisons were conducted for the pressure vessel of austenitic stainless steel 316L.

The Assessments of Integrity of SA516 Gr.70 Material for the 60 days Exposure in over 40% Relative Humidity Environments (상대습도 40%이상 환경에서 SA516 Gr.70 재료의 장기간 노출에 따른 건전성 평가)

  • Gwon, Hyeok-Cheol;Lee, Du-Ho;Seong, Gi-Bang
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2014.11a
    • /
    • pp.193-194
    • /
    • 2014
  • 원전은 고온기능시험 이후 2차계통 내부를 상대습도 40%이하로 관리하여 계통 재질 부식을 최소화하고 있다. 일반적으로 발전소에서는 운전 정지 후 상대습도 40%이하로 낮추는데 15일정도 소요되지만, 발전소 계통 중 일부 곡관부위는 약 60일정도 소요된다. 본 연구는 일부 계통 재료가 상대습도 제한치(<40%) 이상의 환경에서 장기간(최대 60일) 노출시 재료 건전성에 미치는 영향 평가이다. 평가를 위해 시편의 실험 전, 후 무게변화를 이용한 부식률 측정과 표면분석을 위해 광학현미경을 이용하였다. 사용 시편의 재료는 SA516 Gr.70이며 표면상태를 인위적으로 산화피막을 생성 시킨 것(2개)과 산화피막이 없는 것(6개)으로 2종류로 제작하였다. 총 시험기간은 60일이고 시험기간 중 산화피막이 없는 시편은 7일, 21일, 60일에 시편을 2개씩 꺼내어 무게를 측정하여 부식률을 계산하였다. 실험결과, 산화피막이 없는 시편은 노출되는 시간에 따라 부식률이 각각 0.35(7일), 0.21(21일), 0.67(60일) mpy이었고 산화피막이 있는 시편은 0.06(60일) mpy였다. 산화표면 분석결과, 산화피막이 없는 시편은 노출되는 시간에 관계없이 물방울이 맺힌 부분에 pitting을 확인하였다. 하지만, 산화피막이 있는 시편은 pitting의 흔적은 없었다. 산화피막이 없는 시편의 경우 시간에 따라 부식률은 높아지지만 학계에서 통용되는 뛰어난 내부식성 재료의 부식률 기준인 < 1 mpy이하기 때문에 재료 건전성에 미치는 영향은 거의 없을 것으로 판단된다. 또한, 대부분 원전의 경우 고온기능시험 또는 운전기간 동안에 2차계통 구성 재료 표면에 산화막이 생성되었기 때문에 산화피막이 있는 시편의 결과로 판단하면 상대습도 40%이상에 60일 이상 노출되어도 부식은 거의 일어나지 않았을 것으로 사료된다. 실증실험결과를 가지고 종합적으로 평가하면 상대습도 40%이상 환경에서 곡관부위가 60일이상 노출되어도 재료 건전성에 미치는 영향은 거의 없을 것으로 판단된다.

  • PDF

The Analysis of Landscape Ecological Effect of Forest by Trail-Building (등산로 개설에 의한 산림의 경관생태학적 영향 분석)

  • Lee, Woo-Sung;Park, Kyung-Hun;Kim, Dong-Pil
    • Korean Journal of Environment and Ecology
    • /
    • v.22 no.2
    • /
    • pp.128-137
    • /
    • 2008
  • The purpose of this study is to analyze the effect of hiking trails on forest landscape's fragmentation, based on which also to assess the landscape-ecology-based integrity by small drainage area by selecting Bukhansan National Park as a survey target. The results of effect analysis are as follow; size of forest patch decreased; the density of patch and edge increased; patch shape became complicated; the dimensions of core area noticeably decreased and proximity degree between patch increased after trail-building. In addotion, the assessment results of overall landscape ecology-based integrity by small drainage basin showed that the Bukhansan catchment area was highest making 3.7 point, while Gugi catchment area was rated the lowest making 1.6 point. Putting the above results together, it is necessary to prohibit the opening up of unnecessary trails and to make room for ecological restoration of damaged and disturbance area to their original state as nature goes for landscape-ecology-based conservation and management of forests.