• 제목/요약/키워드: 건물에너지 소비량

검색결과 80건 처리시간 0.024초

인공신경망 변수에 따른 HVAC 에너지 소비량 예측 정확도 평가 - 송풍기를 중심으로- (An Analysis of the Prediction Accuracy of HVAC Fan Energy Consumption According to Artificial Neural Network Variables)

  • 김지헌;성남철;최원창;최기봉
    • 대한건축학회논문집:구조계
    • /
    • 제34권11호
    • /
    • pp.73-79
    • /
    • 2018
  • In this study, for the prediction of energy consumption in the ventilator, one of the components of the air conditioning system, the predicted results were analyzed and accurate by the change in the number of neurons and inputs. The input variables of the prediction model for the energy volume of the fan were the supply air flow rate, the exhaust air flow rate, and the output value was the energy consumption of the fan. A predictive model has been developed to study with the Levenbarg-Marquardt algorithm through 8760 sets of one-minute resolution. Comparison of actual energy use and forecast results showed a margin of error of less than 1% in all cases and utilization time of less than 3% with very high predictability. MBE was distributed with a learning period of 1.7% to 2.95% and a service period of 2.26% to 4.48% respectively, and the distribution rate of ${\pm}10%$ indicated by ASHRAE Guidelines 14 was high.8.

Metal Layer의 두께 변화에 따른 ZnO/Ag/ZnO 다층 박막의 특성 연구 Properties of Multi Layer (ZnO/Ag/ZnO Thin Films With Different Metal Layer Thickness)

  • 이승민;이상렬;김홍배
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제44회 동계 정기학술대회 초록집
    • /
    • pp.352-352
    • /
    • 2013
  • 국내 에너지 소비량의 21.6%가 건물 분야에 소비되고 있다. 창호는 벽체에 비해 8~10배 이상 낮은 단열 특성을 가지기 때문에 열 손실량이 크다. 유리는 창호를 이루는 요소 중 가장 큰 면적을 차지하고 있으며, 창호의 단열성능을 2배로 향상시키면 30% 이상 건물의 에너지 절감 효과를 가질 수 있다. 창호의 단열 성능을 향상시키기 위해서 Low-e(emissivity) 기술 연구가 진행 중이다. 이번 실험에서는 RF 마그네트론 스퍼터링 시스템을 사용하여 XG 유리기판 위에 ZnO박막을 증착하고, evaporator 장비를 사용하여 metal층인 Ag를 증착하였다. 그리고 다시 한번 ZnO박막을 증착하였다. Low-e 연구에 활용할 수 있는지를 확인하기 위해 XRD, AFM, 투과도를 측정하였다. ZnO박막의 증착 조건은 초기압력 $3.0{\times}10^{-6}$ Torr, 공정압력 $2.0{\times}10^{-2}$ Torr, RF파워 30 W, Ar gas는 50 sccm, 증착온도는 상온으로 하였다. Metal층인 Ag를 증착하기 위해 evaporator의 증착 조건은 Rotate rate 2 rpm, voltage 0.3V, 공정압력 $5.0{\times}10^{-6}$ Torr이며, 변수로 Ag두께를 3,5,7,9,11,13,15 nm로 하였다. AFM 측정결과 Ag두께가 증가할수록 RMS roughness값이 높아졌으며, 최소 0.71 nm의 거칠기를 가지는 것을 확인하였다. XRD분석결과 37도 부근의 피크가 발생하여 ZnO 박막이 결정질 구조임을 확인할 수 있었다. 그리고 UV-Visible-NIR 분광 광도계를 이용하여 광학적 투과를 측정한 결과 Ag두께가 13 nm일 때 가시광 영역의 투과도가 최대 75%, 적외선 영역의 투과도가 최소 28%로 좋은 차단 특성을 가지는 것을 확인하였다. 위 결과들로 ZnO 박막이 Low-e 기술에 활용될 수 있음을 확인하였다.

  • PDF

공동주택 단위세대의 생애 비용 최적화 방법론 연구 (The Life Cycle Cost Optimization Methodology as a Tool for Designing Apartment Units)

  • 박태근
    • 한국건설관리학회논문집
    • /
    • 제1권1호
    • /
    • pp.80-86
    • /
    • 2000
  • 최근 공동주택의 유지관리를 위한 인건비, 에너지비가 급속하게 증가하고 있다. 이에 따라 설계단계에서 이 비용을 절감할 수 있는 기법의 필요성이 제기되고 있다. 공동주택에 있어서는 대부분의 경우 세대당 동일한 내외벽, 창호 등이 반복적으로 사용되므로 단위평면의 LCC 최적화가 전체 건물의 LCC 최적화에 있어서 가장 중요하다. 이를 위하여 본 연구에서는 LCC 비용항목 중 공동주택의 물리적 시스템에 탄력성있게 변화하는 LCC 비용항목을 파악하였고, 초기건축비, 보수교체비, 에너지비를 종합적으로 최적화시킬 수 있도록 LCC 부위단가 개념을 도입하여 공동주택 적정치수 산정방법을 제시하였다. 여기에서 보수교체비산정은 보수교체비용 최소화에 의한 최적 보수교체주기법에 근거하였으며, 에너지 소비량 추정은 DOE-2에 의한 동적 에너지 부하량을 추정하여 LCC 부위단가 개념에 접목하였다. 보수교체비 최적화 기법과 동적에너지 분석에 의한 LCC 부위단가 개념은 기존의 개념과는 다른 독창적인 개념이다.

  • PDF

주거용 건물의 유형에 따른 환경조절요구에 대한 분석 (An Analysis of Demand for Environmental Controls on Different Residential Building Types)

  • 이승복;원종서
    • 설비공학논문집
    • /
    • 제16권10호
    • /
    • pp.960-968
    • /
    • 2004
  • One of the most important functions of a building is to provide thermally comfortable indoor environmental conditions for the occupants. Therefore, a great deal of energy is consumed for heating and cooling to satisfy those thermal requirements. In order to provide thermal comfort with minimum heating and cooling energy consumption, optimal design of building affecting indoor climate is required. This study used the TRNSYS for modeling and simulation of the energy flows of residential building types, and examined the energy efficient measures to reduce the thermal loads. The residential building types are classified into the detached house, apartment house and high-rise residential complex. The results of the simulation show that the heating energy consumption in the detached house is especially high, whereas the cooling load is an important determinant in the apartment house and high-rise residential complex. The measures examined are the insulation thickness, various types of glazing, infiltration, natural and controlled ventilation, solar shading, orientation and etc. Comparative evaluations and sensitivity analyses revealed the effects of these variables and identified their energy efficient building design strategies.

분뇨처리방법의 비용 및 에너지소비 비교 (Comparing Night Soil Treatment Processes in Aspects of Cost and Energy Consumption)

  • 유기영
    • 유기물자원화
    • /
    • 제16권3호
    • /
    • pp.38-45
    • /
    • 2008
  • 서울에는 아직도 생활하수와 빗물이 함께 흘러가는 합류식 하수관거가 많다. 합류식 관거 지역의 모든 건물은 화장실 세정수로부터 고체상 물질을 분리해서 저장하는 정화조가 설치되어 있다. 정화조는 연 l회이상 청소를 해야 하며 수거된 분뇨는 처리시설을 필요로 한다. 선행연구에 따르면 서울에서는 분뇨량이 꾸준히 증가하여 2020년에는 1일 3,549kL의 시설이 부족하다고 한다. 이 부족한 부분을 어떤 시설로 확보할 것인가에 도움을 주고자 본 연구는 수행되었다. 현재와 같은 하수병합방식에 의해 1일 3,549톤의 분뇨를 처리할 때는 연간 64억원의 비용이 소요되고 공공하수처리시설 방류수 수준으로 처리하면 연간 700억원으로 비용이 급격히 증가한다. 전력량소비량에서는 각각 연간 260만kWh, 8,161만kWh로 비용보다 더 큰 차이가 예성된다. 결국 하수처리시설에서의 분뇨의 병합처리는 비용적 환경적 측면에서 크게 유리한 방법이었다.

  • PDF

두개의 제어기를 사용한 건물 내부의 온도변화와 에너지소비량을 계산하기 위한 해석적 연구 (A study on the analytical method for calculating the inside air temperature transient and energy consumption load of the building using two different controllers)

  • 한규일
    • 수산해양기술연구
    • /
    • 제48권1호
    • /
    • pp.82-90
    • /
    • 2012
  • Four different buildings having various wall construction are analyzed for the effect of wall mass on the thermal performance and inside building air and wall temperature transient and also for calculating the energy consumption load. This analytical study was motivated by the experimental work of Burch et al. An analytical solution of one-dimensional, linear, partial differential equations is obtained using the Laplace transform method, Bromwich and modified Bromwich contour method. A simple dynamic model using steady state analysis as simplified methods is developed and results of energy consumption loads are compared with results obtained using the analytical solution. Typical Meteorological Year data are processed to yield hourly average monthly values. This study is conducted using weather data from two different locations in Korea: Daegu having severe weather in summer and winter and Jeju having mild weather almost all year round. There is a significant wall mass effect on the thermal performance of a building in mild weather condition. Buildings of heavyweight construction with insulation show the highest comfort level in mild weather condition. A proportional controller provides the higher comfort level in comparison with buildings using on-off controller. The steady state analysis gives an accurate estimate of energy load for all types of construction. Finally, it appears that both mass and wall insulation are important factors in the thermal performance of buildings, but their relative merits should be decided in each building by a strict analysis of the building layout, weather conditions and site condition.

대학교 기숙사의 전력소비량과 BIPV시스템의 발전효율·부하부담율에 관한 연구 (A Study on the Power Consumption and the Generation Efficiency and Load Rate of the Building Integrated Photovoltaic System in University Dormitories)

  • 서원덕;이강국;홍원화
    • KIEAE Journal
    • /
    • 제11권6호
    • /
    • pp.87-93
    • /
    • 2011
  • This study examines building's power consumption unit cost and Building Integrated Photovoltaic (BIPV)'s generation efficiency and load rate with the subjects of university dormitory buildings in order to suggest foundational data for new and recycled energy use and management to plan and operate university dormitories afterwards. Thereby, this research gained the following findings. 1. The quantity of solar radiation and efficiency change in the BIPV system applied to the research subject buildings after the lapse of time was averagely 8.7%, and it is thought that temperature increase determines conversion efficiency with the influence of surrounding outside temperature and the module's temperature. 2. The generation efficiency of the BIPV system in the research subject buildings was averagely 10.9%. In May, it was 13.9%, and in January, it was the lowest as 10.25%. Considering the fact that power consumption reduces during an intermediate period, it will be necessary to establish measures for equipment and power consumption load balancing. 3. The monthly load rate of the BIPV system was averagely 4.09%. In May, it was the highest as 4.94%, and in July, it was the lowest as 3.24%. 4. It is intended to conduct constant follow-up research on estimating university dormitory building's power consumption unit cost and examining the generation efficiency and load rate of the BIPV system.

애스터리스크(*) 배열구조 기반 전력저감 수배전반 (Asterisk(*) Array structure based power reduction power distribution board)

  • 김미숙;박동삼
    • 한국산학기술학회논문지
    • /
    • 제18권11호
    • /
    • pp.138-144
    • /
    • 2017
  • 오늘날 전력수요 급증에 따른 전력소비량이 증가하고 있어 전력손실을 줄일 수 있는 에너지 저감을 위한 설계 또는 설비 대체로 전력의 고품질화가 필요하다. 배전반이란 한전의 발전설비로부터 전기를 공급받아 각 건물에 필요한 설비에 계통별 또는 용도별로 나누어 주는 기계장치이다. 배전반은 일반적으로 외함, 개폐기, 전력용 도체, 제어부분으로 구성된다. 본 연구는 배전반내의 메인 요소인 통전을 위한 전력용 도체에 관한 것이다. 실효교류저항 측정시험을 통해 기존방식 판상도체의 수직 배열구조가 비효율적 구조임을 입증해 본다. 실효교류저항이 많이 증가하면 표피효과로 인해 상대적으로 도체의 단면적이 커지게 된다. 본 연구는표피효과를 줄여 실효교류저항을 최소화시키는 애스터리스크(*) 배열구조를 기반으로 설계하여 에너지 절약과 원자재 절감을 연구하였다. 본 연구의 핵심기술 원리는 애스터리스크 배열구조를 적용하여 도체저항 감소기술 기반 에너지 절감 수배전반이다. 수배전반의 교류전력 공급용 판상도체 각각(rst 또는 abc)의 상에서 발생한 자기장이 상호작용으로 상쇄 소멸될 수 있도록 한 판상도체 배열구조에 관한 것으로 효과로는 판상도체에서 유도성 리액턴스의 발생량이 줄어들면서 유효단면적이 증가, 실효교류저항을 줄인다.

정치식 원적외선 건조기를 이용한 알팔파 건초 조제 기술 연구 (Study on Hay Preparation Technology for Alfalfa Using Stationary Far-Infrared Dryer)

  • 김종근;김현래;정은찬;;장태균
    • 한국초지조사료학회지
    • /
    • 제42권2호
    • /
    • pp.73-78
    • /
    • 2022
  • 본 시험은 우리나라에서 인공건초 조제 기술을 확보를 위해 수행되었다. 원적외선 히터를 활용하여 온도, 송풍량, 원적외선 방사량을 조절할 수 있는 기기를 제작하여 4차 수확한 알팔파를 대상으로 실시하였다. 건조를 위한 조건은 전체 4개의 조건을 선택하여 수행하였으며 각각의 조건은 방사율은 40% 내외(33-42%)로 설정을 하여 복합 조건에서는 시간이 지날수록 방사율을 낮추었다. 온도는 58~65℃로 설정하였으며, 기기내의 기류의 속도는 60m/s로 고정하였다. 전체적인 건조시간은 단일조건에서는 30분, 복합조건은 60분(30-30분) 및 90분(30-30-30분)으로 설정하여 시간대별로 방사율과 온도에 변화를 주었다. 건조 조건 1 (30분건조)의 경우에는 최종 건물함량이 46.26%로 건초에 적합한 건물에는 도달하지 못하였다. 그러나 나머지 2~7번 건조 조건에 해당하는 알팔파는 모두 건물함량이 80% 이상으로 나타나 최적의 알팔파 건초가 생산되었다. 건조 조건에 따른 전력 소비량의 차이를 보면 2번 건조조건에서 4.7 KW로 가장 낮게 나타났으며 나머지 건조조건은 6.5~7.1KW로 높았다. 조단백질 함량은 평균 25.91%로 높게 나타났으며 수확 당시(23.39%)보다 전체적인 함량은 높아졌다. 또한 5번 건조 조건에서 가장 높은 함량을 나타내었으며(26.93%) 6번 건조 조건에서 가장 낮은 값을 나타내었다(25.16%). 소화율은 평균 84.90%로 높은 값을 나타내었으며 처리간에 유의적인 차이를 나타내지 않았다(p>0.05). TDN 함량은 ADF 함량을 기반으로 하여 계산된 수치로 전체적인 경향은 ADF 함량과 비슷하였으며 원적외선 건조 조건에서 대체로 높은 경향을 보여주었다. 한편 4차 예취한 알팔파 건초의 RFV 값은 평균 166으로 높았으며 열풍건조 조건에서 유의적으로 낮았으며 원적외선 건조 조건에서는 큰 차이가 없었다. 이상의 결과를 종합하여 볼 때 2번 건조조건이 가장 유리한 것으로 판단되었다.

최적구조설계를 이용한 SRC 기둥의 CO2 배출량 평가 (CO2 Emissions Evaluation for Steel Reinforced Concrete Columns Based on the Optimal Structural Design)

  • 최세운;전지혜;이환영;김유석;박효선
    • 한국전산구조공학회논문집
    • /
    • 제26권5호
    • /
    • pp.335-342
    • /
    • 2013
  • 최근 환경오염 문제에 대한 심각성이 대두되며 전 세계적으로 환경부하 저감을 위해 다양한 노력을 쏟고 있다. 특히 환경 저해 산업의 하나인 건설분야에서는 $CO_2$배출량과 에너지 소비량을 줄이기 위해 활발한 연구를 진행해 왔다. 그러나 건설분야의 기존 연구들은 대부분 $CO_2$배출량이 가장 큰 사용 및 유지관리 단계에만 집중하고 있으며, 설계단계에 대한 연구는 2D의 철근콘크리트 부재 및 구조물에 대해서만 실행되었을 정도로 초기단계이다. 사실, LCA적 관점에서 친환경적 건설산업을 이루기 위해서는 건물의 초기설계 단계에서부터 $CO_2$배출량을 저감시키기 위한 방향으로 설계를 유도할 수 있어야 하며, 구조 엔지니어로서 환경성을 고려한 설계안을 제시할 수 있어야 한다. 그러므로 본 연구에서는 매입형 합성기둥(SRC)을 대상으로 $CO_2$최적화 기법을 제시하였으며, 이를 통해 얻은 여러 설계단면을 이용하여 SRC기둥의 $CO_2$배출량에 영향을 미치는 3가지 요소((1) 강재 크기, (2) 콘크리트 압축강도, (3) 작용 하중 크기)에 대한 영향관계를 분석하였다.