• Title/Summary/Keyword: 건물성능시뮬레이션

Search Result 106, Processing Time 0.024 seconds

3D Object Modeling for Laser Radar Simulation (레이저레이더 시뮬레이션을 위한 3차원 객체 모델링)

  • Kim, Geun-Han;Jun, Chul-Min
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.16 no.2
    • /
    • pp.57-65
    • /
    • 2008
  • The improvement of the performance in laser radar simulation requires fast retrievals of the spatial locations and attributes of objects in response to the laser signals of the simulators. Since the data used in simulation are complex 3D objects such as terrain, buildings and vehicles, and are of large sizes, commonly used 3D modeling tools are not suitable for this use. We proposed a method to store such 3D objects in a database, perform required queries and integrate with visualization tools. We showed the processes for the data modeling based on 3D topological concepts and then building a spatial DBMS. Also, we illustrated the process for accessing and visualizing the stored data using VRML and performed test computations using some laser signal data. With further enhancement on data modeling and LOD problems in visualization, the proposed method will be practically applied in different situations including laser simulation.

  • PDF

A Road Traffic Noise Management Using a Noise Mapping Simulation (소음지도 시뮬레이션을 이용한 도로교통소음 개선방안 연구)

  • Kim, Hyung-Chul;Jeong, Jea-Hun;Kwon, Woo-Taeg
    • The Journal of the Acoustical Society of Korea
    • /
    • v.26 no.7
    • /
    • pp.353-360
    • /
    • 2007
  • Rapid urbanization and population increasing are making a high-rise residential building and high-density residential area. According to spacial concentration of population is occurred road traffic noise problem. Now we are popularly using almost only noise barrier installation, but it makes many disfunctions such as poor landscape, low noise barrier performance and crimes. The purpose of this research is to figure out which is best method one the traffic noise management. Alternative are composed to building layout type ($30^{\circ},\;90^{\circ},\;180^{\circ}$), separation between road and residential building, noise barrier types(noise barrier only, noise barrier and forests and etc). The noise barrier are shown to reduce barrier and building layout angle $30^{\circ}$ position is the best comparing with horizontal and vertical layouts. The gab distance is decreased approximately noise level 5dB(A). We figured out there are noise important method except noise barrier wall and it was analyzed how much decreased. This can be very useful before making a road planning and residential building design.

Economic Comparison of Medium Capacity and Multi Boiler System Applied to Military Officer Housing (군간부 숙소에 적용한 중용량 및 멀티보일러 시스템의 경제성 비교)

  • Kim, Min-yong;Kim, Young Il;Chung, Kwang Seop
    • Journal of Energy Engineering
    • /
    • v.24 no.4
    • /
    • pp.81-88
    • /
    • 2015
  • In midst of electrical energy consumption on the rise due to the industrial development and the improved quality of living, medium capacity and multi boilers which use gas that is comparatively low cost and can be supplied reliably are simulated for energy consumption using the partial load data obtained from the experiment. Economic analysis that considers initial and operation costs is carried out based on the Annual equal payment method.

Simulation and Verification Experiment of Cooling and Heating Load for a Test Space with Forced Ventilation (강제환기가 적용된 시험공간에서 냉난방부하의 시뮬레이션 및 실증실험)

  • Kim, Dong-Hyuk;Hong, Hi-Ki;Yoo, Ho-Seon;Kim, Ook-Joong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.12
    • /
    • pp.947-954
    • /
    • 2006
  • Building energy consumption according to the ventilation has been considered to be an important subject. The purpose of this study is to investigate the cooling and heating loads in a test space with a forced ventilating system. In the test space, on/off controlled air-conditioning and forced ventilating facility were operated between 8 : 30 to 21 : 00 during 4 days and some important data like temperatures and energy consumption were measured to obtain actual thermal loads. The simulation was carried out in a mode of temperature level control using a TRNSYS 15.3 with a precisely measured air change amount and performance data of air-conditioner. Heating load and cooling load including sensible and latent were compared between by experiment and by simulation. Both of thermal loads associated with ventilation show a close agreement within an engineering tolerance.

Performance Prediction on the Application of a Ground-Source Heat Pump(GSHP) System in an Office Building (업무용 건물의 지열 히트펌프 시스템에 대한 성능 예측)

  • Sohn, Byonghu;Kwon, Han Sol
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.9
    • /
    • pp.409-415
    • /
    • 2014
  • Ground-source heat pump (GSHP) systems have become an efficient alternative to conventional cooling and heating methods due to their higher energy efficiency. These systems use the ground as a heat source and the heat sink for cooling mode operation. The purpose of this simulation study is to evaluate the performance of a hypothetical GSHP system in an office building and to assess the energy saving effect against the existing HVAC systems (boiler and turbo chiller). We collected monthly energy consumption data from an actual office building ($32,488m^2$) in Seoul, and created a model to calculate the hourly building loads with EnergyPlus. In addition, we used GLD (Ground Loop Design) V8.0, a GSHP system design and simulation software tool, to evaluate hourly and monthly performance of the GSHP system. The energy consumption for the GSHP system based on the hourly simulation results were estimated to be 582.6 MWh/year for cooling and 593.2 MWh/year for heating, while those for the existing HVAC systems were found to be 674.5 MWh/year and 2,496.4 MWh/year, respectively. The seasonal performance factor (SPF) of the GSHP system was also calculated to be in the range of 3.37~4.28.

Night Purge Control Strategies With Outdoor Air Temperature Conditions for Central Cooling System (중앙냉방시스템의 외기온도조건을 고려한 나이트 퍼지 제어방안에 관한 연구)

  • Hwang, Jin-Won;Ahn, Byung-Cheon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.10
    • /
    • pp.6759-6765
    • /
    • 2015
  • In this study, the effects of control strategies of night-purge control system on control characteristics and energy consumption for central cooling system in building are researched by simulation. The start time and set-point temperature for night-purge control with outdoor temperature changes and building cold storage performance are obtained. The system analysis modelling is done by using TRNSYS program package, and the control performances with suggested night-purge control method are compared with the existing control ones. As a result, the suggested night-purge control method shows maximum 16.8% and 28.6% energy saving in comparison with existing control method and conventional one without night-purge control, respectively.

Assessment of Insolation Data in Korea for Building Energy Performance Assessment (건물에너지 성능 평가를 위한 효과적 기상자료 선정에 관한 연구)

  • Kim, K.S.;Kim, C.B.;Park, J.U.;Yoon, J.H.;Lee, E.J.;Song, I.C.
    • Solar Energy
    • /
    • v.18 no.3
    • /
    • pp.31-39
    • /
    • 1998
  • Selection of a right weather data set has been considered as one of important factors for a successful building energy audit process. A set of 30 year raw weather data base for six major cities has been developed to provide the weather data file for building energy audit and retrofit analysis in Korea. The program named as KWDP(KIER Weather Data Processor) uses the DB to produce a right data set for a specific building energy performance simulation program like DOE2.1E. A program called WMAKE has been developed to generate the right set of input parameters for DOE2.1E weather utility program. The set of the programs could provide the right weather data for specific building energy audit and retrofit analysis.

  • PDF

Realization of Digital control of Grid_connected Modular Photovoltaic Inverter (계통연계형 모듈형 태양광 인버터의 디지털 제어의 구현)

  • Lee, Seung min;Lee, Woo cheol
    • Proceedings of the KIPE Conference
    • /
    • 2011.11a
    • /
    • pp.287-288
    • /
    • 2011
  • 주택 혹 산업용, 공공건물용으로 상용화 되어 있는 스트링 어레이 중앙 인버터 방식은 고압의 DC 배선으로 인한 안전문제, 고가의 고압 DC 차단기의 설치 및 과전압보호기 등으로 가격이 상승하게 되고 설치 시에도 패널간 균일 성능을 보장해야하고 스트링 상에 놓여 있는 패널 일부가 불량이거나 그림자가 져서 발전이 미비할 경우 전체 시스템 발전이 정지하거나 발전량이 미비해지는 문제가 생기므로 항상 최적의 상태로 운전할 수 없다. 그래서 이러한 태양광 발전 방식의 문제점을 해결하기 위해 각 모듈마다 마이크로 인버터를 장착하여 각각 패널마다 분산적인 MPPT(Maximum Power Point Tracking) 를 수행할 수 있고 DC 배선이 없기 때문에 시스템 설치비용을 획기적으로 절감할 수 있으며 안정성 문제도 중앙 인버터 방식보다 획기적으로 향상된다. 패널 또는 인버터 고장 시 전체 시스템의 차단 없이 교체가 가능 하여 시스템의 설비 이용률을 최대로 할 수 있다. 이러한 패널에 쓰이는 마이크로 인버터를 PSIM으로 구현하여 DLL로 통해 디지털 제어로 구현을 하고 시뮬레이션으로 통해 시스템의 효능을 알아보았다.

  • PDF

Analysis and Estimation for Stress Distributions under the Spacer Arrangement in a Vacuumed-Panel (진공패널의 지지대 배열에 따른 응력분석 및 평가)

  • Kim, Jae-Kyung;Jeon, Euy-Sik
    • Proceedings of the KAIS Fall Conference
    • /
    • 2009.12a
    • /
    • pp.159-162
    • /
    • 2009
  • 세계적인 에너지 자원 무기화와 더불어 에너지 효율이 높은 창호개발이 지속적으로 진행되고 있다. 이중 진공패널은 단열성능이 우수하여 건물에서의 에너지 절약 측면에서 미래의 창호소재로 각광 받고 있으나 구조 및 제조공법에 관한 규명이 되어 있지 않다. 진공패널은 대기압 및 외력에 견딜 수 있도록 구조를 형성해야 하며, 이를 위하여 진공간극을 유지하기 위한 지지대를 사용한다. 본 논문에서는 진공패널에서 지지대의 배열에 따른 진공패널의 응력분석과 이 데이터 평가를 통한 허용응력 내에서의 유리지지대 배열방안을 제시하고 시뮬레이션을 통해 그 타당성을 검증하였다.

  • PDF

A Study on Energy Reduction of Passive Factor Apply for the Improvement of Energy Performance in Public Building (공공기관 건물의 에너지 성능개선을 위한 패시브 요소 적용의 에너지 절감율 분석 연구)

  • Son, Ji-Hoon;Kim, Sam-Uel
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.196-201
    • /
    • 2011
  • The energy used in Korea is strongly dependent on that produced by foreign countries. Accordingly, saving energy is more important than ever, because of the rise of international oil prices and depletion of oil resources. The development of energy efficient buildings is required especially for public buildings in Korea. In this study, the energy use of public buildings is identify. Then, the analysis of energy usage through regional offices in Busan City offers energy performance for public buildings.

  • PDF