• 제목/요약/키워드: 건도(Quality)

검색결과 658건 처리시간 0.025초

공원 음수대의 수질 특성 및 영향인자 연구 (Water Quality Characteristics and Influencing Factors of Park Drinking Fountains)

  • 권상조;김은아;조덕희;이효진;정승규;조승연
    • 한국물환경학회지
    • /
    • 제40권5호
    • /
    • pp.229-242
    • /
    • 2024
  • This study investigated water quality characteristics and influencing factors of park drinking fountains having directly piped water systems by analyzing stagnation water (first draw) and water after a 10-minute flush (flushed water). First draws exhibited significant variations in residual chlorine, heavy metals, bacteria, and turbidity, which were largely influenced by usage frequency and external environmental contamination. However, water quality stabilized after flushing. A seasonal analysis indicated that the greatest difference in residual chlorine between first draws and flushed water occurred in spring, followed by that in winter when drinking fountains were discontinued, accompanied by increased zinc concentrations in stagnation water. A comparative analysis of water quality variability by faucet type revealed that push-button faucets exhibited greater variabilities in copper, zinc, and nickel levels than screw-down faucets, likely due to corrosive by-products generated from water hammer effects. Additionally, an analysis based on exterior material indicated that metal fountains experienced higher temperature increases and elevated zinc concentrations in first draws than stone fountains. Regarding installation environments, drinking fountains exposed to direct sunlight or partial shade had higher concentrations of copper, zinc, and nickel in first draws than those installed in constant shade. Overall, these findings suggest that frequent use or flushing can help maintain stable water quality with the exception of push-button faucets.

전처리 및 건조방법에 따른 곶감의 품질변화 (Quality Changes in Dried Persimmons Processed by Different Pretreatment and Drying Method)

  • 문광덕;김종국;손태화
    • 한국식생활문화학회지
    • /
    • 제8권4호
    • /
    • pp.331-335
    • /
    • 1993
  • 건시의 품질향상을 위하여 국내 유명산지의 건시를 시료로 하여 건시의 제조시험과 품질평가에 관한 기초자료로서 그 품질요소를 조사하였다. 건시의 수분함량은 30-36%였으며, 탄닌함량은 0-20%로 무처리구는 $CO_2$와 alcohol 처리구보다 그 함량이 높게 나타났다. 전당함량은 55-60%였고 그 구성은 glucose와 fructose로 구성되어 있었다. 열풍건조에 의한 건시의 제조는 천일건조보다 그 품질이 전반적으로 우수하였으며 특히 slice 한 제품의 품질은 전과의 경우보다 비교적 우수하였다.

  • PDF

저장 중 건오디박 첨가 빵의 품질 특성 (Storage Quality Characteristics of Bread Added with Dried Mulberry Pomace)

  • 김현정;신숙경;김미리
    • 한국식품영양과학회지
    • /
    • 제42권12호
    • /
    • pp.1972-1980
    • /
    • 2013
  • 본 연구는 항산화능이 높으나 버려지는 오디박을 건조시킨 후 분쇄하여 분말 형태로 모닝빵에 첨가(1, 3, 5%)하여 $4^{\circ}C$에서 7일간 저장하면서 품질 특성 및 노화 특성을 분석하였다. 또한 관능평가를 통해 기호도를 알아보고, 건오디박 모닝빵에 적절한 건오디박 첨가의 배합과 제빵의 최적조건을 제시하고자 하였다. 저장일이 증가할수록 수분함량은 유의적으로 감소하고 무게도 감소하였으나, 건오디박을 첨가한 모닝빵의 수분함량은 건오디박 첨가량이 증가할수록 수분함량의 감소 정도가 대조군에 비해 낮았다. 명도는 건조 오디박의 첨가량이 증가할수록 감소하였고 저장일이 증가할수록 증가하였다. 적색도는 건조 오디박의 첨가량이 증가할수록 증가하였고 저장일이 증가할수록 감소되었다. 황색도는 건조 오디박의 첨가량이 증가할수록 감소하였고 저장일이 증가할수록 감소했다. 조직감 중 경도는 저장기간이 경과됨에 따라 높아졌으나 건오디박 첨가량이 증가할수록 경도의 증가폭은 적었다. 이를 통해 노화됨에 따라 전분조직의 변화로 인해 빵의 경도가 단단해지는 것을 건오디박이 막아주는 것을 확인하였다. 탄력성은 저장기간이 증가할수록 낮아지고 건오디박을 첨가할수록 낮아지는 경향을 나타냈지만 유의적 차이는 없다. 응집력은 저장기간이 증가할수록 낮아지고 샘플 간의 유의적 차이는 나타나지 않았다. 시차주사열량계로 측정한 결과, 건오디박 첨가량이 증가할수록 엔탈피가 감소하여 대조군에 비하여 노화도가 감소되어 오디박 첨가가 빵의 노화를 지연시키는 효과를 확인했다. 관능검사 결과 기호도에서 외관의 색, 맛, 향은 3% 건오디박 첨가군이 가장 높았다. 조직감은 0일에는 대조군이 가장 높았고 5일부터는 3% 건오디박 첨가군이 가장 높았다. 전반적인 기호도와 구입의사는 저장 0, 1, 3일에 1% 건오디박 첨가군이 가장 높았고 저장 5, 7일에는 3% 건오디박 첨가군이 가장 높았다. 강도검사 결과 건오디박을 첨가할수록 색과 오디향, 오디맛의 강도가 높게 나타났으며, 이와 반대로 조직감의 강도는 건오디박의 첨가량이 증가할수록 낮아지는 것을 볼 수 있다. 이상의 연구를 통해 모닝빵 제조 시 건오디박의 첨가는 수분 보지력을 높여 수분함량 변화를 최소화하고, 조직이 변화되는 것을 막아 경도에서 단단함을 보완하는 것이 가능한 것으로 보인다. 또한 관능검사에서 가장 기호도가 높았던 건오디박 3% 첨가군이 가장 바람직한 제조방법으로 사료된다.

수직관에서의 이상유동 특성 (Characteristics of Two-Phase Flow in Vertical Pipe)

  • 배병모;심우건
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.879-882
    • /
    • 2004
  • Two-phase flow exists in many industrial components. Characteristics of two-phase flow have been studied by many researchers; however, a further study of the two-phase is required for flow-induced vibration. Characteristics of two-phase flow were measured by force sensor at the end of a vertical pipe. The predominant frequency of fluctuation was obtained for various speeds of flow pattern. A correlation to slug frequency for horizontal flow was obtained by Heywood & Richardson (1979), while Legius et al (1997) for vertical flow. A coefficient based on the correlation is estimated and then compared to the existing ones. The existing empirical formulations for average void fraction were proposed by Wallis (1969), Zuber et al (1967) and Ishii (1970). In the present result, flow parameters, such as flow quality and real velocity, are evaluated with void fraction.

  • PDF

경기도 기초지자체 대기환경 관리정책 지원을 위한 선행 연구 (Preliminary Research to Support Air Quality Management Policies for Basic Local Governments in Gyeonggi-do)

  • 전찬일;강진구;오민영;최재형;신종현;황찬원
    • 한국환경보건학회지
    • /
    • 제49권5호
    • /
    • pp.275-288
    • /
    • 2023
  • Background: When basic local governments want to improve their air quality management policies, they need fundamental evidence, such as the effectiveness of current policies or scenario results. Objectives: The purpose of this study is to lay the groundwork for a process to calculate air pollutant reduction from basic local government air quality policies and provide numerical estimates of PM2.5 concentrations following improved policies. Methods: We calculated the amount of air pollutant reduction that can be expected in the research region based on the Gyeonggi-do Air Environment Management Implementation Plan issued in 2021 and guidelines from the Korean Ministry of Environment. The PM2.5 concentration variations were numerically simulated using the CMAQ (photochemical air quality model). Results: The research regions selected were Suwon, Ansan, Yongin, Pyeongtaek, and Hwaseong in consideration of population, air pollutant emissions, and geographical requirements. The expected reduction ratios in 2024 compared to 2018 are CO (3.0%), NOx (7.9%), VOCs (0.7%), SOx (0.1%), PM10 (2.4%), PM2.5 (6.1%), NH3 (0.05%). The reduced PM2.5 concentration ratio was highest in July and lowest in April. The expected concentration reduction of yearly mean PM2.5 in the research region is 0.12 ㎍/m3 (0.6%). Conclusions: Gyeonggi-do is now able to quickly provide air pollutant emission reduction calculations by respective policy scenario and PM2.5 simulation results, including for secondary aerosol particles. In order to provide more generalized results to basic local governments, it is necessary to conduct additional research by expanding the analysis tools and periods.

과냉 비등류의 실제건도와 보이드율에 관한 연구 (A Study on the Real Quality and Void Fraction of Subcooled Refrigerant Flow)

  • 김종헌;김춘식;김경근;오철
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제17권2호
    • /
    • pp.36-43
    • /
    • 1993
  • Real quality and axial void fraction distribution of subcooled refrigerant flow is very important to predict the heat transfer rate and pressure drop in the design of refrigerating system. In the subcooled boiling region, the liquid bulk temperature is still below the corresponding saturation temperature. But beyond the net vapor generation point, bubble detachment is occured actively from the vapor layer formed on the wall. A reliable method to predict the vapor fraction from the liquid bulk temperature is suggested in this paper. And also the actual quality of the subcooled R-113 flow is calculated in the range of 261-1239kg/$m^2$s mass velocity and 10-30K subcooling.

  • PDF

감마선 조사와 저장 기간에 따른 건멸치류의 품질 및 열발광 특성 (Quality and Thermoluminescence Properties of ${\gamma}$-Irradiated Boiled-Dried Anchovies during Storage)

  • 권중호;노정은;변명우
    • 한국식품저장유통학회지
    • /
    • 제9권1호
    • /
    • pp.19-27
    • /
    • 2002
  • 건멸치의 위생적 품질개선을 위한 감마선 조사가 품질에 미치는 영향을 조사하였으며, 아울러 감마선 조사 멸치에 대한 검 지법으로서 열발광 특성을 분석하였다. 건멸치류의 미생물 오염도는 총세균이 $10^4$~$10^{6}$ CFU/g 수준으로 건멸치의 종류에 따라 큰 타이를 보였으며, 대장균군은 모든 시료에서 음성으로 나타났다. 미생물학적 품질개선을 위한 3kGy 수준의 감마선 조사는 유통조건(식품포장용 PVC film, 0.06 mm, 500 g)으로 포장하여 6개월 저장(15$\pm$1$^{\circ}C$) 후에도 검출한계이하(20 CFU/g)의 수준을 유지할 수 있었다 저장 중 건멸치의 기계적색도(L, a, b, ΔE ), 갈색도, TBA가, VBN, TMA-N, 관능적 특성 등 건멸치의 품질에 관련된 여러 인자들은 3 kGy의 감마선 조사에 의해 거의 영향을 받지 않았다. 그러나 저장기간에 따른 영향은 매우 크게 나타났으며, 이는 저장온도와 포장조건의 중요성을 뒷받침해 주었다. 건멸치의 방사선 조사 여부 확인을 위한 열발광 특성을 분석해 본 결과, 비조사구는 280~30$0^{\circ}C$ 부근에서 매우 낮은 peak를 나타내었고, 1 kGy 이상의 감마선 조사구는 20$0^{\circ}C$ 전후에서 조사선량에 의존적($R^2$=0.9933)인 높은 glow curve를 나타내어 감마선 조사 건멸치의 판별이 가능하였고, - 2$0^{\circ}C$에서 6개월간 저장 후에도 검지가 가능하였다.

시판 건 해초류(미역, 김, 다시마 등) 중 아황산염류 함량 조사 (Sulfates Contents Survey on Dried Seaweeds in Market)

  • 함희진;김무상;김명희
    • 한국식품위생안전성학회지
    • /
    • 제15권4호
    • /
    • pp.340-343
    • /
    • 2000
  • 서울시내 건 해산물 도매시장인 중부시장으로 반입되는 건 해조류에 대한 아황산염류 함량을 조사한 결과 30ppm 이상을 함유하는 검체가 0.19%(2/1063)이었고, 건 미역 2건에서 171.4ppm. 295.7ppm으로 모니어-월리암스 변법에 의한 검사 결과 나타났다. 아연분말 환원법에 의한 간이 검사 결과에서는 아황산염류 함량 1-30ppm인 경우가 전체 1063건 가운데 54건으로 5.08%를 차지하였고, 품목별로는 김 28건, 건 미역 27건 그리고 다시마 2건에서 단응을 보여 이들 품목들의 가공에 아황산염류가 문제시되고 있음이 나타났다. 앞으로도 건 해조류에 대한 아황산염류 등 첨가물 검사가 강화되어야만 안전한 건 해조류가 시민에게 공급될 수 있으리라고 보여진다.

  • PDF

감마선 조사 건조과일의 품질평가 및 물리적 판별 (Quality Evaluation and Physical Identification of Irradiated Dried Fruits)

  • 정재훈;정윤미;조덕조;권중호
    • 한국식품영양과학회지
    • /
    • 제41권11호
    • /
    • pp.1559-1564
    • /
    • 2012
  • 건포도(Thailand산), 건망고(Philippine산), 건무화과(Iran산)를 0~5 kGy로 감마선 조사한 후 총균수 및 기계적 색차를 측정하고 조사여부 판별가능성을 확인하였다. 총 균수 측정 결과 3 kGy 이상으로 조사된 시료에서는 대부분 검출할 수 없는 수준으로 나타나 미생물학적으로 안전함을 알 수 있었다. 건조과일의 색차 측정에서, 건망고의 색 변화가 방사선조사에 가장 민감하였다. PSL 측정 결과, 건포도의 경우 비 조사시료는 음성으로, 조사시료는 중간 값으로 확인되었고 건망고의 경우 모든 시료가 음성으로 확인되었으며, 무화과의 경우 5 kGy 조사시료만이 양성으로 확인되어, 건조과일의 경우 PSL 측정법은 screening 방법으로의 적용가능성이 낮았다. TL 측정 결과 건무화과의 경우 조사시료는 $150{\sim}200^{\circ}C$ 사이에서 특유의 발광곡선을 나타내었고, 신호 강도 또한 조사선량에 의존적으로 증가하여 TL 적용이 가능하였다. ESR 측정 결과 건포도와 건망고의 경우 조사시료에서 multi-component 신호를 보여주었고, 신호 강도 역시 조사선량에 따라 유의적으로 증가하여 ESR 적용이 가능하였다.

2상 마이크로 채널 히트 싱크에서의 유동 비등 열전달에 관한 연구 (Study on flow boiling heat transfer in two-phase micro-channels heat sink)

  • 최용석;임태우
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제39권7호
    • /
    • pp.702-708
    • /
    • 2015
  • 본 연구에서는 FC-72를 작동 유체로 사용하여 이상 유동 비등에 관한 실험을 수행하였다. 마이크로 채널은 깊이 0.2mm, 폭 0.45mm, 길이 60mm 그리고 채널의 개수는 15개로 구성되었다. 실험은 질량유속과 열유속 각각 $200-400kg/m^2s$, $5.6-49.0kW/m^2$ 범위와 증기 건도 0.02-0.93 범위에서 수행되었다. 실험 결과에 따르면 낮은 건도(x<0.2)영역에서는 핵비등에 의한 열전달이 지배적으로 작용하며, 그 이상의 증기 건도 영역에서는 핵비등과 강제 대류 비등의 영향이 복합적으로 작용하는 것으로 나타났다. 핵비등과 강제 대류 비등은 각각 비등수와 대류수에 관한 함수로 표현할 수 있으며, 실험에서 얻어진 열전달 계수는 기존의 상관식에 의한 열전달 계수와 비교하였다.