• Title/Summary/Keyword: 거주성능

Search Result 149, Processing Time 0.023 seconds

Study of Multi-Resident Location Tracking Service Model Based on Context Information (상황정보 기반의 다중 거주자 위치 추적 서비스에 관한 연구)

  • Won, Jeong Chang;Man, Ko Kwang;Chong, Joo Su
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.3 no.5
    • /
    • pp.141-150
    • /
    • 2014
  • In recent years, because of the development of ubiquitous technology in healthcare research is actively progress. Especially, healthcare service area is change to home for the elderly or patients from hospital. The technology to identify residents in a home is crucial for smart home application services. However, existing researches for resident identification have several problems. In this case, residents are needed to attach of various sensors on their body. Also relating private life, it is difficult to apply to resident's environment. In this paper, we used constraint-free sensor and unconscious sensor to solve these problems and we limited using of sensor and indoor environment in the way of working economical price systems. The way of multi-resident identification using only these limited sensors, we selected elements of personal identifications and suggested the methods in giving the weight to apply these elements to systems. And we designed the SABA mechanism to tract their location and identify the residents. It mechanism can distinguish residents through the sensors located each space and can finally identify them by using the records of their behaviors occurred before. And we applied the mechanism designed for applications to approve this location tracking system. We verified to the location tracking system performance according to the scenario.

이슈 & 이슈 - 원하는 만큼 고쳐쓰는 '아파트 리모델링'

  • 대한설비건설협회
    • 월간 기계설비
    • /
    • s.277
    • /
    • pp.48-55
    • /
    • 2013
  • 국토교통부(장관 서승환)는 수직증축 리모델링 허용 등을 포함한 '공동주택 리모델링 제도개선 방안'(6.5 발표)의 후속조치로 노후 공동주택 거주 주민이 부담 가능한 범위에서 불편사례를 선택적으로 개선할 수 있도록 '맞춤형 리모델링' 활성화를 위한 연구용역을 마무리하고, 조만간 가이드라인을 제작 발표할 계획이라고 밝혔다. 가이드라인에는 주차장 부족, 배관 노후화 등 노후 공동주택 거주 주민들의 주요 불편사항(급 배수관 노후화, 주차장 부족, 난방효율 저하, 승강기 부족 등)을 효과적으로 해소할 수 있도록 단지 동 세대 내에서 각각 시행할 수 있는 총 39가지의 리모델링 아이템에 대한 소개와 공사비 등의 정보가 포함될 예정이다. 먼저, 단지내 리모델링에는 데크 지하주차장 신설, 녹지 보육시설 및 헬스장 등 확충, 노후상가 철거 후 별동 증축 등이 포함되며, 아파트 개별 동 내에서는 급 배수관/전기 통신/소방 등 노후 설비 교체, 승강기 신설, 코어증축(복도${\rightarrow}$계단식 변경) 등이, 세대 내에는 문 창호 및 내장재 교체, 단열 기밀 등 에너지 성능 향상, 실내공간 재배치 등이 포함된다. 특히, 아이템별 이주기간을 재실형과 이주형으로 구분하여 주민 선택의 폭을 한층 더 넓힐 것으로 기대된다.

  • PDF

연안여객선 거주구 실내디자인 개선방안에 관한 연구

  • Park, Jin;Lee, Han-Seok
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2019.11a
    • /
    • pp.127-129
    • /
    • 2019
  • 전라남도 완도 연안여객선 터미널에서 2018년 10월 연안여객선 현대화편드 1호에 의한 선박 '한일고속페리 실버클라우드호'가 취항식을 가졌다. 국내 여객선 시장은 그간 해외 중고선에만 의존해왔는데 순수 국내 기술로 건조된 여객선이 등장한 것이다. 이에 따라 우리나라 여객선 산업은 기술발전과 디자인 등 그 품질이 향상 될 것이다. 그간 여객선 이용객의 수요는 꾸준히 증가하고 있으나 영세한 규모의 국내 선사는 비용 부담 때문에 신조를 건조하기 어려워 해외 중고선을 수입하였다. 이로 인해 국내 여객선의 실내 인테리어의 노후화, 인테리어 개조에 따르는 선박 성능의 저하 등 다양한 문제점을 가지고 있었다. 따라서 정부는 2018년 현대화펀드를 통해 노후된 연안여객선을 대체할 새로운 선박의 건조를 지원함으로써 연안여객선은 이제 선사의 사적 소유물을 넘어 공공적 성격이 교통수단이 되었다. 이로써 연안여객선은 이동 편의 향상을 비롯하여 승객에게 더 큰 만족을 줄 수 있는 디자인 개선방안이 요구된다.

  • PDF

An analysis on the Relative Weights of Residential Environmental Constituents - Comparison of the Dwellers' and Experts' Evaluations - (주거환경 구성요소의 상대적 가중치 분석 - 일반인과 전문가 평가의 비교를 중심으로 -)

  • Kang, In-Ho;Lee, Seung-Mi;Park, In-Seok
    • Journal of the Korean housing association
    • /
    • v.20 no.2
    • /
    • pp.69-76
    • /
    • 2009
  • The evaluation of the quality of residential environment, in the planning process, is very important. If the environmental quality can be measured on the design scheme itself, it would be possible not only to estimate the residential environment, but also to apply the results of measuring in the planning and design of new residential projects. This study aimed at estimating the relative weights of the constituents of a residential environment by AHP (Analytic Hierarchy Process). For the detailed analysis of relative weights, the respondent of survey were composed of two different groups-dwellers and experts. The findings are as follows (:) 1) the relative weights of residential constituents were different between the respondent groups; 2) the relative weights of residential constituents were different according to socio-demographic characteristics; and 3) for the practical application of estimation results of the relative weights, the relation between residential performance constituents and physical design elements should be considered.

선박진동 허용기준

  • 정균양
    • Bulletin of the Society of Naval Architects of Korea
    • /
    • v.31 no.3
    • /
    • pp.36-42
    • /
    • 1994
  • 고품질 선박 평가의 중요한 척도인 진동허용 기준에 대한 관심이 점차 높아지고 있다. 진동 허 용기준은 선박 계약시 건조사양에 포함될 뿐 아니라 건조후 시운전 결과 평가시나 인도후 아프터 서비스 과정에서도 선주와 건조자간에 자주 거론되는 항목이다. 평가 관점으로서는 .승무원의 거주성 및 작업성 .구조 부재의 피로파괴 발생 가능성 .기계기기 기구들의 성능 보존성 등이 있으며 IOS(국제표준화기구)나 여러 선급 기준들이 사용되고 있다. 그러나 보다 쾌적한 거주구나 작업 구역을 원하는 탑승자들의 욕구가 커짐에 따라 최근 저 진동선을 요구하는 선주 들의 허용기준에 대한 관심 또한 늘어나고 있다. 이에 따라 IOS는 선박진동의 종합평가 기준인 IOS 6954 개정 작업을 진행중에 있으며 일부 선급에서도 자체적으로 보완한 기준들을 제시하고 있다. 반면에 조선소들의 입장에서 보면 그간 진동 예측 방법과 방진설계 기술이 발전된 덕분에 심각한 진동문제는 많이 줄어들었다 하겠으나 90년대 아후 선박의 고속화에 따른 기진력 증가로 인하여 저 진동 선박 건조가 쉽지만은 않은 것이 최근의 상황이다. 따라서 본 고에서는 현재 사용되는 각종 선박진동 허용 기준들을 다시 정리하고 그중 강화될 전망이 있는 거주구 진동 허용기준에 대한 변화 추세를 살펴보고자 한다.

  • PDF

An experimental study on the thermal response characteristic for a water mist nozzle in accommodation on passenger ships (선박 거주구역용 미분무수 노즐의 열응답 특성에 관한 실험적 연구)

  • Han, Yong-Shik;Choi, Byung-Il;Kim, Myung-Bae;Lee, Yu-Whan;Do, Kyu-Hyung;Kim, Chang
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2010.10a
    • /
    • pp.163-166
    • /
    • 2010
  • 여객선 선실 등 선박 거주구역에 사용되는 노즐의 열응답 특성에 관한 실험적 연구를 수행하였다. IMO(국제해사기구)의 수계소화설비 성능평가 기준에 따르면 구주구역에 설치되는 소화시스템의 노즐은 조기 반응 응답 특성을 확보하여야 한다. 본 연구에서는 glass bulb의 선정과 풍동실험을 통해 반응 응답 값을 측정하였으며, 노즐 헤드 형상의 개선을 통해 IMO 기준이 요구하는 RTI(반응시간지수) < $50ms^{1/2}$의 조건을 만족하는 노즐 헤드를 개발하였다.

  • PDF

A Study on the Durability Analysis of Underground parking lot and User Awareness on apartment -Focusing on the Bundang New Town- (공동주택 건축물의 지하주차장 내구성 분석 및 사용자 인식 연구 - 분당 신도시를 중심으로 -)

  • Suhr, Myong-Suk
    • The Journal of the Convergence on Culture Technology
    • /
    • v.7 no.4
    • /
    • pp.727-734
    • /
    • 2021
  • The purpose of this study is to analyze the perception of the residents of the new city by examining the consciousness of the occupants to understand the characteristics of the residents of the city of Bundang. As a result of evaluating and analyzing the durability by visual inspection and some equipment tests at the site of the on-site investigation, it was found that there is a problem with the quality, and continuous maintenance is required to improve the durability and usability of the apartment house. In particular, many cracks appearing in the rapidly deteriorated part should be repaired promptly, and a systematic plan should be formulated and carried out. In the apartment housing perception survey of Bundang new city residents, about 93.4% showed above-average satisfaction, and 43.4% showed a favorable preference toward the residential area.

Performance Review and Revitalizing Support Plans for Rural Residence though Current Status Survey (현황조사를 통한 농촌주거의 성능검토 및 재생지원방안)

  • Park, Junmo;Kim, Okkyue
    • Korean Journal of Construction Engineering and Management
    • /
    • v.16 no.2
    • /
    • pp.3-11
    • /
    • 2015
  • The urban has been improved houses and facilities as accelerating industry and society, while the rural area was inferior to the city. Furthermore, there was not a maintenance in time as ageing, and did not expect to rebuilding of using proper techniques and materials for financial reasons. This study find a way to make a revitalizing plan for appropriate real state. For this, perform a current status survey that 900 rural residences of 36 rural villages in Chungcheong area. As a result, Korean traditional structure is a half in residential type, and has poor residential conditions by comparison with western pattern. The structural type comprises two type that a pure structure and a mixed structure, and Korean traditional structure is a mixed structure more than a pure structure. It is considered continuous changes by a resident due to a pure structure was not satisfy various functions. It need appropriate plan to improve a rural residence for each characteristics.

Post Occupancy Evaluation for Office Building with An Underfloor Air Distribution System (바닥공조 시스템이 적용된 사무공간의 거주후 성능평가)

  • Yoon, Seong-Hoon;Jang, Hyang-In;Jung, Hae-Kwon;Choi, Sun-Kyu;Yu, Ki-Hyung
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.6
    • /
    • pp.78-85
    • /
    • 2011
  • In this study, an underfloor air distribution(UFAD) system installed on the S. office building was evaluated for its indoor environmental quality performance. Field measurement and survey were conducted for the overall POE(Post Occupied Evaluation). PMV(including temperature, humidity, air velocity and globe temperature) and several environmental components were measured while thermal comfort, thermal sensation, acoustical environment and others. were investigated through survey. Except for the direct upper part of the air supply diffuser on the floor, the indoor velocity was less than 0.25m/s, which has been suggested by ASHRAES tandard 55 as the limit for thermal comfort. MRT of the perimeter zone of the room showed a higher value than that in the interior because of the introduced solar radiation through the building envelope. PMV was generally maintained in the range of thermal comfort (from -0.5 to +0.5), though it weighted to the warm side. It was reported to have 61% positive response on thermal comfort and 55% on neutral thermal sensation. The results of each survey item showed some gender-based differences. Specifically, female respondents had higher degree of dissatisfaction with indoor air cleanness and acoustical privacy. The working surface showed more than 400 lux and the equivalent noise level showed less than 50 dB(A). In conclusion, the results of the measurement and survey showed good agreement. Indoor environmental quality of the subject office room where the UFAD system was installed showed an overall excellent performance.

A Study on Seismic Performance of External Reinforcement for Unreinforced Masonry Buildings (비보강 조적조 건축물의 외부 보강에 따른 내진성능 연구)

  • Jong-Yeon Kim;Jong Kang
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.28 no.2
    • /
    • pp.43-52
    • /
    • 2024
  • In this study, we evaluated the seismic performance of a masonry building that was not designed to be earthquake-resistant and attempted to improve the seismic performance by adopting a seismic reinforcement method on the exterior of the building. In addition, the building seismic design standards and commentary(KDS 41 17 00:2019) and existing facility(building) seismic performance evaluation methods were applied to evaluate seismic performance, and a pushover analysis was performed using non-linear static analysis. As the result of this study, it was determined that seismic reinforcement was urgent because the distribution rate of earthquake-resistant design of houses in Korea was low and masonry structures accounted for a large proportion of houses. When reinforcing the steel beam-column+brace frame in a masonry building, the story drift angle was 0.043% in the X direction and 0.047% in the Y direction, indicating that it satisfied the regulations. The gravity load resistance capacity by performance level was judged to be a safe building because it was habitable in both X and Y directions. In conclusion, it is believed that the livability and convenience of the house can be secured by reinforcing the exterior of the building and the seismic performance and behavior of the structure can be clearly predicted.