• Title/Summary/Keyword: 거울 실험

Search Result 108, Processing Time 0.02 seconds

Autofocus of Infinity-Corrected Optical Microscopes by Confocal Principle and Fiber Source Modulation Technique (공초점 원리와 광섬유 광원 변조를 이용한 무한보정 현미경 자동초점)

  • Park, Jung-Jae;Kim, Seung-Woo;Lee, Ho-Jae
    • Korean Journal of Optics and Photonics
    • /
    • v.15 no.6
    • /
    • pp.583-590
    • /
    • 2004
  • The autofocus is one of the important processes in the automated vision inspection or measurements using optical microscopes, because it influences the measuring accuracy. In this paper, we used the confocal microscope configuration based on not a pinhole but a single-mode optical fiber. A single mode fiber has the functions of source and detector by applying the reciprocal scheme. As a result, we acquired a simple system configuration and easy alignment of the optical axis. Also, we embodied a fast autofocus system by acquiring the focus error signal through a source modulation technique. The source modulation technique can effectively reduce physical disturbances compared with objective lens modulation, and it is easily applicable to general optical microscopes. The focus error signal was measured with respect to the modulation amplitude, reflectance of the specimen and inclination angle of the measuring surface. The performance of the proposed autofocus system was verified through autofocusing flat mirror surface. In addition, we confirmed that source modulation rarely degrades the depth resolution by the comparison between the FWHMs of axial response curves.

Design and fabrication of a holographic scanner using the ray tracing method (광선 추적을 이용한 홀로그래픽 스캐너의 설계 및 제작)

  • 김종재;정만호
    • Korean Journal of Optics and Photonics
    • /
    • v.10 no.2
    • /
    • pp.107-113
    • /
    • 1999
  • Low-aberration holographic scanners that eliminate the need for lenses and mirrors promise to greatly reduce the cost of laser printers and image scanners. In this study, a holographic optical element that can simultaneously scan and focus a laser beam is designed with analytic ray tracing method. An analytic and experimental work is conducted in which we investigated the hologram structure and hologon configuration for linear aberration-free scanning. For a prototype scanner, a He-Ne laser is used to manufacture and reconstruct the hologram, and the measured bow is about $\pm$133$\mu\textrm{m}$ and spot size(half-intensity beamwidth) in under 100$\mu\textrm{m}$ for a 300 mm scan length without using a correcting lens or mirror. The diffraction efficiency is about 55$\pm$5%, which is acceptably flat. The experimentally measured results agrees with the computed values. From this fact, we can conclude that the computed results using ray tracing method are practical and useful values, and have a potential for use in high resolution laser printers.

  • PDF

Numerical Modeling and Experimental Verification for Target Strength of Submerged Objects (수중물체에 대한 음향 표적강도의 수치해석과 실험적 검증)

  • CHOI YOUNG-HO;SHIN KEE-CHUL;YOU JIN-SU;KIM JEA-SOO;JOO WON-HO;KIM YOUNG-HYUN;PARK JONG-HYUN;CHOI SANG-MUN;KIM WOO-SHIK
    • Journal of Ocean Engineering and Technology
    • /
    • v.19 no.1 s.62
    • /
    • pp.64-70
    • /
    • 2005
  • Target Strength(TS) is an important factor for the detection of the target in an active sonar system: thus the numerical model for the prediction of TS is widely being developed. For the frequency range of several kHz, the most important scattering mechanism is known to be specular reflection, which is largely affected by the geometrical shape of the target. In this paper, a numerical algorithm to predict TS is developed based on the Kirchhoff approximation which is computationally efficient. The developed algorithm is applied to the canonical targets of simple shapes, for which the analytical solutions exist. The numerical results show good agreement with the analytical solutions. Also, the algorithm is applied to more complex scatterers, and is compared with the experimental data obtained in the water tank experiment for the purpose of verifying the developed numerical model. Discussions on the effect of spatial sampling and other aspects of numerical m odeling are presented.

Catadioptric Omnidirectional Stereo Imaging System and Reconstruction of 3-dimensional Coordinates (Catadioptric 전방향 스테레오 영상시스템 및 3차원 좌표 복원)

  • Kim, Soon-Cheol;Yi, Soo-Yeong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.6
    • /
    • pp.4108-4114
    • /
    • 2015
  • An image acquisition by using an optical mirror is called as a catadioptric method. The catadioptric imaging method is generally used for acquisition of 360-degree all directional visual information in an image. An exemplar omnidirectional optical mirror is the bowl-shaped hyperbolic mirror. In this paper, a single camera omnidirectional stereo imaging method is studied with an additional concave lens. It is possible to obtain 3 dimensional coordinates of environmental objects from the omnidirectional stereo image by matching the stereo image having different view points. The omnidirectional stereo imaging system in this paper is cost-effective and relatively easy for correspondence matching because of consistent camera intrinsic parameters in the stereo image. The parameters of the imaging system are extracted through 3-step calibration and the performance for 3-dimensional coordinates reconstruction is verified through experiments in this paper. Measurable range of the proposed imaging system is also presented by depth-resolution analysis.

Start-up circuit with wide supply swing voltage range and modified power-up characteristic for bandgap reference voltage generator. (넓은 전압 범위와 개선된 파워-업 특성을 가지는 밴드갭 기준전압 발생기의 스타트-업 회로)

  • Sung, Kwang-Young;Kim, Jong-Hee;Kim, Tae-Ho;Vu, Cao Tuan;Lee, Jae-Hyung;Lim, Gyu-Ho;Park, Mu-Hum;Ha, Pan-Bong;Kim, Young-Hee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.8
    • /
    • pp.1544-1551
    • /
    • 2007
  • A start-up circuit of the bandgap reference voltage generator of cascode current mirror type with wide operating voltage range and enhanced power-up characteristics is proposed in the paper. It is confirmed by simulation that the newly proposed start-up circuit does not affect the operation of the bandgap reference voltage generatory even though the supply voltage(VDDA) is higher and has more stable power-up characteristic than the conventional start-up circuit. Test chips are designed and fabricated with $0.18{\mu}m$ tripple well CMOS process and their test has been completed. The mean value of measured the reference voltage(Vref) is 738mV and The three sigma value($3{\sigma}$) is 29.88mV.

Comparison of Orbit-attitude Model between Spot and Kompsat-2 Imagery (Spot 영상과 Kompsat-2 영상에서의 궤도 자세각 모델의 성능 비교)

  • Jeong, Jae-Hoon;Kim, Tae-Jung
    • Korean Journal of Remote Sensing
    • /
    • v.25 no.2
    • /
    • pp.133-143
    • /
    • 2009
  • This paper describes differences of performance when the orbit attitude model is applied to the respective images obtained from two different types of satellite. The one is Spot that rotates its pointing mirror and the other is Kompsat-2 that rotates its whole body when they obtain imagery for target. Our research scope is limited to the orbit-attitude model only as its good performance was proved in prior investigation. Model performances between two images were compared with sensor model accuracy and 3D coordinates calculation. The results show performances of the orbit-attitude model for each image type were different. For Spot imagery, the model required attitude angle to be included as adjustment parameters. For Kompsat-2 imagery, the model required high-order parameter for adjustment. This implies that satellite sensor model may be applied differently in accordance with platform's attitude control scheme and accuracy. Understanding of this information can be a base for improvement and development of model and application for new satellite images.

Optical Encryption of Binary Information using 2-step Phase-shifting Digital Holography (2-단계 위상 천이 디지털 홀로그래피를 이용한 이진 정보 광 암호화 기법)

  • Byun, Hyun-Joong;Gil, Sang-Keun
    • Korean Journal of Optics and Photonics
    • /
    • v.17 no.5
    • /
    • pp.401-411
    • /
    • 2006
  • We propose an optical encryption/decryption technique for a security system based on 2-step phase-shifting digital holography. Phase-shilling digital holography is used for recording phase and amplitude information on a CCD device. 2-step phase-shifting is implemented by moving the PZT mirror with phase step of 0 or ${\pi}/2$. The binary data and the key are expressed with random code and random phase patterns. The digital hologram is a Fourier transform hologram and is recorded on CCD with 256 gray level quantization. We remove the DC term of the digital hologram fur data reconstruction, which is essential to reconstruct the original binary input data/image. The error evaluation fer the decrypted binary data is analyzed. One of errors is a quantization error in detecting the hologram intensity on CCD, and the other is generated from decrypting the data with the incorrect key. The technique using 2-step phase-shifting holography is more efficient than a 4-step method because 2-step phase-shifting holography system uses less data than the 4-step method for data storage or transmission. The simulation shows that the proposed technique gives good results fur the optical encryption of binary information.

Passive sonar signal classification using attention based gated recurrent unit (어텐션 기반 게이트 순환 유닛을 이용한 수동소나 신호분류)

  • Kibae Lee;Guhn Hyeok Ko;Chong Hyun Lee
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.4
    • /
    • pp.345-356
    • /
    • 2023
  • Target signal of passive sonar shows narrow band harmonic characteristic with a variation in intensity within a few seconds and long term frequency variation due to the Lloyd's mirror effect. We propose a signal classification algorithm based on Gated Recurrent Unit (GRU) that learns local and global time series features. The algorithm proposed implements a multi layer network using GRU and extracts local and global time series features via dilated connections. We learns attention mechanism to weight time series features and classify passive sonar signals. In experiments using public underwater acoustic data, the proposed network showed superior classification accuracy of 96.50 %. This result is 4.17 % higher classification accuracy compared to existing skip connected GRU network.

Measurement of Optical Purity for Commercially Avialable Dexibuprofen and Ibuprofen Sold in 2013 (2013년도 시판된 Dexibuprofen과 Ibuprofen의 광학 순도 측정)

  • Ryoo, Sang Hyun;Lee, Sang Heon;Seo, Hae Chan;Song, Jung Suk;Ryoo, Dong Hyun;Yu, Jeong Jae;Kim, Hyun Young;Lee, Jae Hwan;Ryoo, Jae Jeong
    • Journal of the Korean Chemical Society
    • /
    • v.58 no.3
    • /
    • pp.277-282
    • /
    • 2014
  • The optical purity of 11 commercial dexibuprofens and 7 ibuprofens sold in Korea in 2013 were examined by chiral HPLC. The Chiralcel OD-H column and LUX-Cellulose-1 column were used as chiral stationary phases and the mixed eluent of hexane:isopropanol:acetic acid as 100:1:0.1 was used as a mobile phase with a flow rate of 1.0 mL/min. Each data was obtained from an average value of at least three different experiments for each sample and the average value of relative standard deviation of them appeared very small, 0.19%. Average optical purity value (97.5%) of eleven commercial dexibuprofens used in this study were smaller than those of 9 years ago (99.2%), but larger than four years ago (95.6%). Enantiomeric ratios of (R)- and (S)-isomers of seven ibuprofen samples used in this experiment were achieved at about 50:50 which was different with the result (44:56) from four years ago.

The Effect of Invisible Cue on Change Detection Performance: using Continuous Flash Suppression (시각적으로 자각되지 않는 단서자극이 변화 탐지 수행에 미치는 효과: 연속 플래시 억제를 사용하여)

  • Park, Hyeonggyu;Byoun, Shinchul;Kwak, Ho-Wan
    • Korean Journal of Cognitive Science
    • /
    • v.27 no.1
    • /
    • pp.1-25
    • /
    • 2016
  • The present study investigated the effect size of attention and consciousness on change detection. We confirmed the effect size of consciousness by comparing the condition which combined attention and consciousness and the condition of attention without consciousness. Then, we confirmed the effect size of attention by comparing the condition of attention without consciousness and the control condition which excluded attention and consciousness. For this purpose, change detection task and continuous flash suppression (CFS) were used. CFS renders a highly visible image invisible. In CFS, one eye is presented with a static stimulus, while the other eye is presented with a series of rapidly changing stimuli, such as mondrian patterns. The result is that the static stimulus becomes suppressed from conscious awareness by the stimuli presented in the other eye. We used a customized device with smartphone and google cardboard instead of stereoscope to trigger CFS. In Experiment 1-1, we reenacted some study to validate our experimental setup. Our experimental setup produced the duration of stimulus suppression that were similar to those of preceding research. In Experiment 1-2, we reenacted a study for attention without consciousness using an customized device. The results showed that attention without consciousness more strongly work as a cue. We think that it is reasonable to use CFS treatment employing smartphone and google cardboard for a follow-up study. In Experiment 2, when performing the change detection task, we measured the effect size of consciousness and attention by manipulating the consciousness level of cue. We used the method in which everything but the variable of interest kept being fixed. That way, the difference this independent variable makes to the action of the entire system can be isolated. We found that there was significant difference of correct response rate on change detection performance among different consciousness level of cue. In this study, we investigated that not only the role of attention and consciousness were different also we were able to estimated the effect size.

  • PDF