• Title/Summary/Keyword: 거동 해석

Search Result 7,269, Processing Time 0.034 seconds

Behavior of Geotextile Tube by Plane Strain Analysis and 3-Dimensional Finite Element Method (평면변형해석과 3-D FEM 기법을 통한 지오텍스타일 튜브의 거동해석)

  • 신은철;오영인
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.5
    • /
    • pp.233-241
    • /
    • 2003
  • Geotextile tube is hydraulically filled with dredged materials and has been applied to coastal protection and scour protection, dewatering method of slurry, and isolation of contaminated material. Recently, geotextile tube technology is no longer alternative construction technique but suitable desired solution. In this paper, the numerical analysis was performed to investigate the behavior of geotextile tube with various properties of geotextile sheet and hydraulic pumping conditions. Numerical analysis was executed to compare with the results from the large-scale field model tests, and also with those of plane strain analysis and 3-D FEM analysis. A geotextile tube was modeled using the commercial finite element analysis program ABAQUS and the one-quarter of tube was modeled. Behavior of geotextile tube during the hydraulic pumping procedure was analyzed by comparing the large-scale field model test and numerical analysis. The shape variation and maximum tube height between the numerical analysis results and large-scale filed test results are turned out to be in a good agreement.

Moment-Curvature Analysis of Steel Fiber-Reinforced Ultra High Performance Concrete Beams with Tension Softening Behavior (인장연화거동을 고려한 강섬유 보강 초고성능 콘크리트 보의 모멘트-곡률 해석)

  • Yang, In-Hwan;Joh, Chang-Bin;Kim, Byung-Suk
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.24 no.3
    • /
    • pp.237-248
    • /
    • 2011
  • Tensile softening characteristics play an important role in the structural behavior of steel fiber-reinforced ultra high performance concrete. Tension softening modeling and numerical analysis method are necessary for the prediction of structural performance of steel fiber-reinforced concrete. The numerical method to predict the flexural behavior is proposed in this study. Tension softening modeling is carried out by using crack equation based on fictitious crack and inverse analysis in which load-crack opening displacement relationship is considered. Thereafter material modeling is performed considering tension softening. The comparison of moment-curvature curves of the numerical analysis results with the test results indicates a reasonable agreement. Therefore, the present numerical results prove that good prediction of flexural behavior of steel fiber-reinforced ultra high performance concrete beams can be achieved by employing the proposed method.

Measurement of Physical Properties of Pepper for Particle Behavior analysis of sorting system for Pepper Harvester (고추수확기용 선별장치의 입자 거동 해석을 위한 고추 물성측정)

  • Byun, Jun Hee;Kim, Su Bin;Kim, Myoung Ho;Kim, Dae Cheol
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2017.04a
    • /
    • pp.9-9
    • /
    • 2017
  • 입자거동해석소프트웨어(EDEM)은 DEM(Discrete Element Method)기법을 이용한 입자 거동 전용 해석툴로 입자 유입량, 위치 등을 조절하여 입자거동과 관련된 제품 개발, 프로세스 최적화를 위한 비용 및 시간 절감에 활용도가 뛰어난 소프트웨어이다. EDEM을 활용하기 위해선 적용대상에 대한 물성치를 적용하여야 한다. 따라서 본 연구에서는 EDEM를 이용하여 현재 연구개발 중인 카드클리너 방식의 고추 선별기의 성능을 분석을 수행하기 위해 고추 물성측정 실험을 수행 하였다. EDEM을 이용한 입자거동해석에 필요한 개인 물성치에는 포아송비, 전단탄성계수, 밀도가 있다. 또한 입자-입자, 입자-Geometry 간의 상호관계를 위한 물성치인 반발계수, 정지마찰계수, 구름마찰계수가 필요하다. 공시 시료인 고추는 광주광역시 남구 승촌동 소재의 개인농가 Plastic 온실로 재배된 '천상'품종을 사용하였다. 푸아송 비와, 전단 탄성계수를 측정하기 위한 인장시험기기로는 만능인장시험기(TA-XT2, Stable Micro, 영국)를 이용하였으며, 인장에 의한 고추의 변형량 축정은 초고속카메라(NX4-SI, IDT, 미국)을 이용하였다. 밀도는 비중병법에 기초하여 질량과 부피를 측정하여 밀도를 계산하였다. 반발계수는 고추의 충돌 실험을 통해 변화한 높이를 이용하여 계산하였고, 충동 실험을 통해 변화한 높이는 초고속카메라를 이용하여 측정하였다. 정지마찰계수와 구름마찰계수는 고추의 미끄러짐이 시작하는 각도와 등속도 운동으로 구르는 각도를 초고속카메라를 이용하여 측정 후 계산하였다. 모든 실험은 3번 반복을 통해 평균값을 시험 결과 값으로 이용하였다. 고추의 대한 물성치 실험결과 고추의 푸아송 비는 0.294(std : 0.2), 전단탄성계수 4.624E+06 Pa, 밀도 $600kg/m^3$로 나타났다. 또한 입자-입자 간의 물성치인 반발계수는 0.383, 정지마찰계수는 0.455, 구름마찰 계수는 0.043로 나타났다. 추후 본 연구에서 측정한 고추의 물성치를 적용한 EDEM 입자거동해석 시뮬레이션을 통해 카드클리너 방식의 고추 선별기의 성능에 대한 분석을 하고자 한다.

  • PDF

Behaviour of Leaking Tunnels under Unconfined Flow Condition (비구속 흐름조건하에 있는 배수형 터널의 거동)

  • Shin Jong-Ho
    • Journal of the Korean Geotechnical Society
    • /
    • v.21 no.7
    • /
    • pp.43-54
    • /
    • 2005
  • Tunnelling in a water bearing soil may cause draw-down of ground water table. Modelling of this problem requires considering the change of phreatic surface including the stress constitutive relationship for an unsaturated soil. However, it is normally assumed that ground water is confined. Numerical formulation of coupled behavior considering phreatic surface is described and implemented into computer program. Influence of unconfined flow on tunnel and ground is thoroughly investigated and compared with that of confined flow condition. It is identified that ground and lining behaviour below phreatic surface is almost the same as that under confined flow conditions, however, there is considerable difference in ground behaviour above phreatic surface. It is generally concluded that the assumption of confined flow is acceptable in terms of lining design.

A Study on the Rational Application of 3D Numerical Analysis for Anchored Earth Retaining Wall (앵커지지 흙막이 벽체의 합리적인 3차원 수치해석기법 적용에 관한 연구)

  • Jeong, Sang-Seom;Sim, Jae-Uk;Lee, Sung-June
    • Journal of the Korean Geotechnical Society
    • /
    • v.32 no.4
    • /
    • pp.29-39
    • /
    • 2016
  • This paper presents the results of 2D and 3D finite element simulations conducted to analyze the effects of excavation depth (H), excavation width (L), and ground condition on the behavior of anchored earth retaining wall in inclined ground layers. The results of numerical analyses are compared with those of the site instrumentation analyses. Based on the results obtained, it appeared that 2D numerical analysis tends to overestimate the horizontal displacement of retaining wall compared to the 3D numerical analysis. When the excavation depth is deeper than 20m, it is found that 2D and 3D numerical analysis results of excavation work in soil ground condition are more different from the results in rock ground condition. For an accurate 3D numerical analysis, applying 3D mesh which has an excavation width twice longer than excavation depth is recommended. Consequently, 3D numerical analysis may be able to offer significantly better predictions of movement than 2D analysis.

Nonlinear Analysis for the Prediction of Lateral Behavior of Single Piles in Non-homogeneous Sandy Soil (비균질 사질토 지반에서 단일말뚝의 수평거동 예측을 위한 비선형 해석기법)

  • 김영수;김병탁;허노영
    • Journal of the Korean Geotechnical Society
    • /
    • v.16 no.4
    • /
    • pp.5-16
    • /
    • 2000
  • THe purpose of this paper is to suggest the analytical method which can predict lateral nonlinear behavior in non-homogeneous soil using the coefficient of soil resistance and ultimate soil resistance. Those parameters are obtained through back analysis on the base of the results of a series of model tests.Analytical method of Chang is more or less difficult to predict nonlinear behavior in non-homogeneous sol. So, in this study, for the prediction of nonlinear behavior the compositive analytical method which apply the p - y curve to Chang model is suggested. Also, the program is developed to predict nonlinear behavior using the compositive analytical method and it can be used to calculated the deflection, bending moment and soil reaction with DFM in non-homogeneous soil. To establish applicability of the suggested analytical method, the results of model tests and field tests and Pentagon2D finite element program are compared with those of the compositive analytical method. In the analysis values of the coefficient of soil reaction and ultimate soil resistance are also applied to the case of non-homogeneous soil. Lateral defection calculated using the compositive analytical method has been found to be in good agreement with values measured in field and model load tests.

  • PDF

Development of Thermal-Hydraulic-Mechanical Coupled Numerical Analysis Code for Complex Behavior in Jointed Rock Mass Based on Fracture Mechanics (균열 암반의 복합거동해석을 위한 열-수리-역학적으로 연계된 파괴역학 수치해석코드 개발)

  • Kim, Hyung-Mok;Park, Eui-Seob;Shen, Baotang;Synn, Joong-Ho;Kim, Taek-Kon;Lee, Seong-Cheol;Ko, Tae-Young;Lee, Hee-Suk;Lee, Jin-Moo
    • Tunnel and Underground Space
    • /
    • v.21 no.1
    • /
    • pp.66-81
    • /
    • 2011
  • In this study, it was aimed to develop a thermal-hydraulic-mechanical coupled fracture mechanics code that models a fracture initiation, propagation and failure of underground rock mass due to thermal and hydraulic loadings. The development was based on a 2D FRACOD (Shen & Stephasson, 1993), and newly developed T-M and H-M coupled analysis modules were implemented into it. T-M coupling in FRACOD employed a fictitious heat source and time-marching method, and explicit iteration method was used in H-M coupling. The validity of developed coupled modules was verified by the comparison with the analytical result, and its applicability to the fracture initiation and propagation behavior due to temperature changes and hydraulic fracturing was confirmed by test simulations.

Behavior of Liquid Droplet Driven by Capillarity Force Imbalance on Horizontal Surface Under Various Conditions (다양한 조건하에서 모세관력 불균형에 의해 구동되는 수평 표면 위의 액적 거동)

  • Myong, Hyon Kook;Kwon, Young Hoo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.4
    • /
    • pp.359-370
    • /
    • 2015
  • The present study aims to numerically investigate the behavior of liquid droplet driven by capillarity force imbalance on horizontal surfaces ranging from hydrophilic to hydrophobic, under various conditions. The droplet behavior has been simulated using an in-house solution code(PowerCFD), which employs an unstructured cell-centered method based on a conservative pressure-based finite-volume method with interface capturing method(CICSAM) in a volume of fluid(VOF) scheme for phase interface capturing. The detailed droplet behavior was obtained under various conditions for droplets with different initial shapes, contact angles and surface tension forces(or Bond number). The mechanism of droplet transport was examined using the numerical results on the droplet shapes.

A Study on Seismic Behavior of Space Frame Bridge Using Three-Dimensional Nonlinear Dynamic Analysis (3차원 비선형 동적해석을 이용한 입체라멘교의 지진거동특성에 관한 연구)

  • 김익현
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.6 no.5
    • /
    • pp.45-51
    • /
    • 2002
  • The characteristics of nonlinear seismic behavior and failure mechanism of RC space frame in railroad viaducts have been studied by the numerical analysis in time domain. The structure concerned is modeled in 3 dimensional extent and the RC frame elements consisting of fibers are employed for the columns. The fibers are characterized as RC zone and PC one to distinguish the different energy release after cracking resulted from the bond characteristic between concrete and re-bar. Due to the deviation of the mass center and the stiffness center of the entire structure the complex behavior is shown under seismic actions. The excessive shear force is concentrated on the column beside flexible one relatively, which leads to the failure of bridge concerned.

Dynamic Analysis of Lateral Pile under Seismic Loading (지진하중을 받는 파일기초의 횡방향 동적 거동해석)

  • 이인모;이현종
    • Geotechnical Engineering
    • /
    • v.4 no.1
    • /
    • pp.29-36
    • /
    • 1988
  • Dynamic analysis of lateral pile under seismic loading is performed in this paper. As an analytical model, the Bean-on-twinkler Foundation Model is used for this study because of its simplicity and acceptible accuracy . The method suggested by Kagawa and Kraft, which can account for non-linear effects, is used for the dynamic P-y relationship This relationship is found to be the most important factor in analysis . Group pile effects are also considered approximately The results of dynamic analysis show that a pile without supporting mass follows the soil movement ; in the case of a pile with supporting mass, the relative displacement between the soil and the pile occurs . When designing piles, it must be considered that piles have to resist the curvatures originated by the soil movement.

  • PDF