• Title/Summary/Keyword: 개인 방호

Search Result 136, Processing Time 0.025 seconds

Water Quality and Hydrochemistry of Natural Springs and Community Wells in Daejeon Area (대전지역 자연샘물 및 공동우물의 수질 및 수리화학적 특성)

  • 정찬호;박충화;이광식
    • Economic and Environmental Geology
    • /
    • v.35 no.5
    • /
    • pp.395-406
    • /
    • 2002
  • The sixty natural springs and community wells used as a drinking water in the Daejeon area are mainly located at the parks and the natural green districts. The purpose of this study is to investigate the characteristics of water quality and the contamination of the springs and the wells, and to suggest the management strategy for the springs and wells. For this study, we undertook water quality data from Daejeon City. According to the statistic analysis of water quality data, unacceptable rate as a drinking water was about 28 percent in 1999 and 24.5 percent in 2000, respectively. Major unacceptable factor is coliform, and others are bacteria, yersinia, color, turbidity, Fe and F. The unacceptable rate shows a roughly positive relationship with precipitation, that is, it shows highest rate during a rainy season between June and September. The major contamination source is likely to be the excrement of wild animals around natural springs and wells. Most of springs are vulnerable to the contamination of coliform and bacteria because of short residence time and shallow circulation in subsurface environment. The water samples collected from 31 springs or wells show weak acidic pHs, the electrical conductivity ranging from 63 to 357 $\mu\textrm{S}$/cm, and the hydrochemical types of Na(Ca)-HC0$_3$ and Ca-HC0$_3$. The groundwater samples of low total dissolved solid(TDS) belong to Na(Ca)-HC0$_3$. type, and the groundwater of high total dissolved solid is shifted towards Ca-HC0$_3$ type in the chemical composition. These hydrochemical characteristics indicate that most natural springs is in the early stage of geochemical evolution. The natural springs should be closed during a rainy season, which shows a high contamination rate. We suggest that a protection barrier around the springs should be built to keep wild animals away from the springs.

Policy Suggestions Regarding to Soil Quality Levels in Korea from a Comparison Study of the United States, the United Kingdom, Germany, the Netherlands, and Denmark's Soil Quality Policies (토양질 기준에 관한 주요 외국 정책의 비교분석을 통한 우리나라의 토양질 기준 개념설정과 적용)

  • Park Yong-Ha;Yang Jae-E;Ok Yong-Sik
    • Journal of Soil and Groundwater Environment
    • /
    • v.10 no.4
    • /
    • pp.1-12
    • /
    • 2005
  • Policies regarding to soil quality of the United States, the United Kingdom, the Netherlands, Germany, and Demark were analyzed to suggest Korean policy for improving soil quality concept and it's implementation. All countries met four criteria: I) Soil quality levels of contaminants are indebt to concept of contaminant risk to recipients (human and ecosystem); ii) Any soil quality value can't be a magic number to determine whether a site is contaminated or not. To determine risk of sites, risk assessment of the sites should be followed; iii) Concentrations of contaminants of sites are not always significantly certain to risk of human and ecosystem of the sites; and iv) Soil quality levels are adopted based on land uses and plans. Considering our rooms to improve policies and analysis of the other country reports on their legislations about soil quality levels, our policy implementation could be approached from these directions: i) Our concept for soil quality levels needs to develop in scientific and rational. ii) Soil quality levels and risk assessment should be implemented as determining tools of site contamination in parallel, and iii) Soil quality levels depending on land uses and plans should be developed in debt with rational and scientific concept of risk. Increasing efficacy of Korea policy regarding the soil quality levels would be in dept to applying concepts of SCL (Soil Contamination Level) and SRL (Soil Regulatory Level) developed, implementing soil quality levels and risk assessment of contaminated sites in conjunction, and classifying three distinctions of land uses based on sensitiveness of recipients (human and ecosystem) to contaminants in soil in this research.

Classification of submitted KSNMT dissertation (대한핵의학기술학회 투고 논문 분류)

  • Han, Dong-Chan;Lee, Hyuk;Hong, Gun-Chul;Ahn, Byeong-Ho;Choi, Seong-Wook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.1
    • /
    • pp.65-69
    • /
    • 2017
  • Purpose KSNMT(Korea Society of Nuclear Medicine Technology) stepping first step in 1997, has published first journal related with nuclear medicine technology in 1985. With classifying In Vivo Session Dissertation reported in the entire journal, trend of the Dissertation will be studied. Materials and Methods Dissertations which published from 1985 to first half of 2016 in the journal are classified with presentation form and with scanner, And all the data is organized with Excel program. Through the data, the number of dissertations published in each year, the number of dissertation published in details, and keyword distributions in each period are analyzed. Results The number of In-vivo section dissertations was 1151 and the number of In-vivo section dissertations that have common subject with In-vitro section was 28. The number of In-vivo section dissertation in 1980s was 46, in 1990s was 149, in 2000 was 467 and from 2010 to the first half of 2016 was 517. The number of dissertation with original articles was 571, with abstract was 529, with symposium was 31, with special lecture was 25, with review was 11, with interesting image was 7, with poster was 3 and with case report was 2. With symposium and special lecture excluded, which count 56, the number of dissertation with PET was 319, with Planar was 302, with SPECT was 172, with radiopharmaceutical was 113, with guard and safety management 103, with BMD was 28, etc. was 86. The number of dissertation about oncology was 201, about scanner was 179, about cardiovascular and circulatory system was 102, about safe environment was 82, about musculoskeletal system was 76, about nervous nuclear medicine was 66, about quality assurance was 61, about genitourinary system was 56, about endocrine system was 49, about digestive system was 44, about Therapy, about industrial safety was 24, about molecular imaging was 15, infection and inflammation was 9, about respiratory system was 8 and etc. was 108. The mostly used keyword through 1999 to 2005 was PET and through 2006 to 2016 was PET/CT. Conclusion To encourage various dissertations to be submitted, Korea Society of Nuclear Medicine should analyze date about not only about dissertations that are already published, but also about various research materials. Moreover, Korea Society of Nuclear Medicine also have to provide technical support such as sharing big data from homepage and systematical support to its member to publish dissertation that has high impact factor. It is important each individual researcher to have continuing effort as well as each organization cooperation.

  • PDF

The Study of Radiation Exposed dose According to 131I Radiation Isotope Therapy (131I 방사성 동위원소 치료에 따른 피폭 선량 연구)

  • Chang, Boseok;Yu, Seung-Man
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.4
    • /
    • pp.653-659
    • /
    • 2019
  • The purpose of this study is to measure the (air dose rate of radiation dose) the discharged patient who was administrated high dose $^{131}I$ treatment, and to predict exposure radiation dose in public person. The dosimetric evaluation was performed according to the distance and angle using three copper rings in 30 patients who were treated with over 200mCi high dose Iodine therapy. The two observer were measured using a GM surverymeter with 8 point azimuth angle and three difference distance 50, 100, 150cm for precise radion dose measurement. We set up three predictive simulations to calculate the exposure dose based on this data. The most highest radiation dose rate was showed measuring angle $0^{\circ}$ at the height of 1m. The each distance average dose rate was used the azimuth angle average value of radiation dose rate. The maximum values of the external radiation dose rate depending on the distance were $214{\pm}16.5$, $59{\pm}9.1$ and $38{\pm}5.8{\mu}Sv/h$ at 50, 100, 150cm, respectively. If high dose Iodine treatment patient moves 5 hours using public transportation, an unspecified person in a side seat at 50cm is exposed 1.14 mSv radiation dose. A person who cares for 4days at a distance of 1 meter from a patient wearing a urine bag receives a maximum radiation dose of 6.5mSv. The maximum dose of radiation that a guardian can receive is 1.08mSv at a distance of 1.5m for 7days. The annual radiation dose limit is exceeded in a short time when applied the our developed radiation dose predictive modeling on the general public person who was around the patients with Iodine therapy. This study can be helpful in suggesting a reasonable guideline of the general public person protection system after discharge of high dose Iodine administered patients.

The Early Experience with a Laparoscopy-assisted Pylorus-preserving Gastrectomy: A Comparison with a Laparoscopy-assisted Distal Gastrectomy with Billroth-I Reconstruction (복강경 보조 유문부보존 위절제술의 초기 경험: 복강경 보조 원위부 위절제술 후 Billroth-I 재건술과의 비교)

  • Park, Jong-Ik;Jin, Sung-Ho;Bang, Ho-Yoon;Chae, Gi-Bong;Paik, Nam-Sun;Moon, Nan-Mo;Lee, Jong-Inn
    • Journal of Gastric Cancer
    • /
    • v.8 no.1
    • /
    • pp.20-26
    • /
    • 2008
  • Purpose: Pylorus-preserving gastrectomy (PPG), which retains pyloric ring and gastric function, has been accepted as a function-preserving procedure for early gastric cancer for the prevention of postgastrectomy syndrome. This study was compared laparoscopy-assisted pylorus-preerving gastrectomy (LAPPG) with laparoscopy-assisted distal gastrectomy with Billroth-I reconstruction (LADGB I). Materials and Methods: Between November 2006 and September 2007, 39 patients with early gastric cancer underwent laparoscopy-assisted gastrectomy in the Department of Surgery at Korea Cancer Center Hospital. 9 of these patients underwent LAPPG and 18 underwent LADGBI. When LAPPG was underwent, we preserved the pyloric branch, hepatic branch, and celiac branch of the vagus nerve, the infrapyloric artery, and the right gastric artery and performed D1+$\beta$ lymphadenectomy to the exclusion of suprapyloric lymph node dissection. The distal stomach was resected while retaining a $2.5{\sim}3.0\;cm$ pyloric cuff and maintaining a $3.0{\sim}4.0\;cm$ distal margin for the resection. Results: The mean age for patients who underwent LAPPG and LADGBI were $59.9{\pm}9.4$ year-old and $64.1{\pm}10.0$ year-old, respectively. The sex ratio was 1.3 : 1.0 (male 5, female 4) in the LAPPG group and 2.6 : 1.0 (male 13, female 5) in the LADGBI group. Mean total number of dissected lymph nodes ($28.3{\pm}11.9$ versus $28.1{\pm}8.9$), operation time ($269.0{\pm}34.4$ versus $236.3{\pm}39.6$ minutes), estimated blood loss ($191.1{\pm}85.7$ versus $218.3{\pm}150.6\;ml$), time to first flatus ($3.6{\pm}0.9$ versus $3.5{\pm}0.8$ days), time to start of diet ($5.1{\pm}0.9$ versus $5.1{\pm}1.7$ days), and postoperative hospital stay ($10.1{\pm}4.0$ versus $9.2{\pm}3.0$ days) were not found significant differences (P>0.05). The postoperative complications were 1 patient with gastric stasis and 1 patient with wound seroma in LAPPG group and 1 patient with left lateral segment infarct of liver in the LADGB I group. Conclusion: Patients treated by LAPPG showed a comparable quality of surgical operation compared with those treated by LADGBI. LAPPG has an important role in the surgical management of early gastric cancer in terms of quality of postoperative life. Randomized controlled studies should be undertaken to analyze the optimal survival and long-term outcomes of this operative procedure.

  • PDF

The study of MDCT of Radiation dose in the department of Radiology of general hospitals in the local area (일 지역 종합병원 영상의학과 MDCT선량에 대한 연구)

  • Shin, Jung-Sub
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.4
    • /
    • pp.281-290
    • /
    • 2012
  • The difference of radiation dose of MDCT due to different protocols between hospitals was analyzed by CTDI, DLP, the number of Slice and the number of DLP/Slice in 30 cases of the head, the abdomen and the chest that have 10 cases each from MDCT examination of the department of diagnostic imaging of three general hospitals in Gyeongsangbuk-do. The difference of image quality, CTDI, DLP, radiation dose in the eye and radiation dose in thyroid was analyzed after both helical scan and normal scan for head CT were performed because a protocol of head CT is relatively simple and head CT is the most frequent case. Head CT was significantly higher in two-thirds of hospitals compared to A hospital that does not exceed a CTDI diagnostic reference level (IAEA 50mGy, Korea 60mGy) (p<0.001). DLP was higher in one-third of hospitals than a diagnostic reference level of IAEA 1,050mGy.cm and Korea 1,000mGy.cm and two-thirds exceeded the recommendation of Korea and those were significantly higher than A hospital that does not exceed a diagnostic reference level (p<0.001). Abdomen CT showed 119mGy that was higher than a diagnostic reference level of IAEA 25mGy and Korea 20mGy in one-third. DLP in all hospitals was higher that Korea recommendation of 700mGy.cm. Among target hospitals, C hospital showed high radiation dose in all tests because MPR and 3D were of great importance due to low pitch and high Tube Curren. To analyze the difference of radiation dose by scan methods, normal scan and helical scan for head CT of the same patient were performed. In the result, CTDI and DLP of helical CT were higher 63.4% and 93.7% than normal scan (p<0.05, p<0.01). However, normal scan of radiation dose in thyroid was higher 87.26% (p<0.01). Beam of helical CT looked like a bell in the deep part and the marginal part so thyroid was exposed with low radiation dose deviated from central beam. In addition, helical scan used Gantry angle perpendicularly and normal scan used it parallel to the orbitomeatal line. Therefore, radiation dose in thyroid decreased in helical scan. However, a protocol in this study showed higher radiation dose than diagnostic reference level of KFDA. To obey the recommendation of KFDA, low Tube Curren and high pitch were demanded. In this study, the difference of image quality between normal scan and helical scan was not significant. Therefore, a standardized protocol of normal scan was generally used and protective gear for thyroid was needed except a special case. We studied a part of CT cases in the local area. Therefore, the result could not represent the entire cases. However, we confirmed that patient's radiation dose in some cases exceeded the recommendation and the deviation between hospitals was observed. To improve this issue, doctors of diagnostic imaging or technologists of radiology should perform CT by the optimized protocol to decrease a level of CT radiation and also reveal radiation dose for the right to know of patients. However, they had little understanding of the situation. Therefore, the effort of relevant agencies with education program for CT radiation dose, release of radiation dose from CT examination and addition of radiation dose control and open CT contents into evaluation for hospital services and certification, and also the effort of health professionals with the best protocol to realize optimized CT examination.