• Title/Summary/Keyword: 개구부의 위치

Search Result 90, Processing Time 0.038 seconds

Histochemical Studies of the Goblet Cell of the Oviduct in Korean Ring-necked Pheasants(Phasianus colchicus karpowi) (한국산 꿩 난관의 술잔세포에 관한 조직화학적 연구)

  • 최성도;로경란;김인식;양홍현
    • Korean Journal of Poultry Science
    • /
    • v.29 no.3
    • /
    • pp.177-183
    • /
    • 2002
  • The study was designed to investigate the aspects of the goblet cell of the oviduct in laying Korean ring-necked pheasants by histochemical methods (PAS, alcian blue-PAS, alcian blue pH 2.5, alcian blue pH 1.0, and aldehyde fuchsin-alcian blue stain). Twelve laying Korean ring-necked pheasants were used. The results were summarized as follows. The goblet cell of the oviduct of the Korean ring-necked pheasant contained sulfated acid mucosubstances and neutral mucosubstances in the infundibulum. The compounds of sulfated acid mucosubstances, nonsulfated acid mucosubstances, and neutral mucosubstances are present in goblet cells of the magnum, vagina and openings of the tubular gland of the uterus of the oviduct in the Korean ring-necked pheasant. The goblet cell of the isthmus and uterus of the oviduct of the Korean ring-necked pheasant contained neutral mucosubstances except openings of the tubular gland of the uterus. The histochemical characteristics of secretory granules of goblet cells in oviduct of the Korean ring-necked pheasant were not related to the position of eggs in oviduct.

태백시 용연동굴 지대의 지리환경

  • 오종우;홍현철
    • Journal of the Speleological Society of Korea
    • /
    • v.36 no.37
    • /
    • pp.81-102
    • /
    • 1994
  • 태백산맥의 가장자리에 위치한 용연동굴은 전형적인 산지Karst(Alpine Karst)의 면모를 갖추고 있다. 용연동굴은 태백시 북서부 화전동 용수골 상부 산사면부 약 980m 상에서 북쪽으로 개구하고 있으며, 용수골 서북부 정상(1,418m)에서 동동남 방향으로 이어지는 능선부 하부 가까이 위치한다. 능선은 비교적 완만하나 남북사면은 개석의 진전으로 약 50도 내외의 급경사 사면지형을 나타낸다. 특히 동굴의 남사면은 용수골 용천수의 하식작용에 의하여 북사면 보다 더욱 경사가 급하다.(중략)

  • PDF

방화문의 구조설계

  • Korea Institute of Registered Architects
    • Korean Architects
    • /
    • no.6 s.66
    • /
    • pp.36-42
    • /
    • 1974
  • 설계가 잘 되어있는 문은 사람이나 물건의 출입에 큰 지장을 주지않고 분리, 차음 및 안전등의 제기능을 충분히 발휘할 것이다. 화염이나 연기의 확산을 조지시키는 일은 안전상 가장 중요한 일 중의 하나이다. 건물의 여러곳에 위치한 문의 기능, 성능의 평가방법과 기준등은 전세계에서 논의의 대상이 되고 있다. 건물의 각부분은 내화구조구획에 의해 각각 분리될 수 있으며, 각 구획을 통하는 개구부는 화재시 자기의 기능을 충분히 발휘할 수 있는 문에 의해 차단될 수 있다. 첫째, 문은 그 문이 위치한 벽체에서 화재차단의 효과를 가져야 하며, 둘째, 피난통로의 안전을 조해하는 연소부산물이 침투하는 것을 방지하여야 한다. 그러므로 모든 방화문은, 건물에서 그 위치의 정도에 따라 연기와 화재의 확산을 막는 장벽으로서의 역할이 요구된다. 본 내용은 현재 논의되고 있는 상황에 대한 영국건축연구소의 연구보고서의 요약 소개이다.

  • PDF

An Experimental Study on the Ultimate Strength and Deformation Capacity of Composite Beams with Eccentric Web Openings (편심유공합성보의 종국내력 및 변형능력에 관한 실험적 연구)

  • Choi, San Ho;Seo, Seong Yeon
    • Journal of Korean Society of Steel Construction
    • /
    • v.12 no.5 s.48
    • /
    • pp.595-604
    • /
    • 2000
  • Web openings of large beams provide space for wiring, piping, and duct work to provide for proper drainage, pipes and duct must be slightly sloped with the attendant result that all web openings can not be centered on the centroidal axes of the beams. Test specimens are made for opening-depth to beam-depth ratio of 0.5 and for eccentricities of the opening center line of 10% from middepth of the beam because of the proximity of the opening edge to the flange. In this paper, available test results and theories relating to the strength of composite beams having eccentric rectangular openings are surveyed and experiments were carried out to examine the structural behaviors. In all the tests in this paper good agreement is demonstrated with maximum loads measured in tests, and observed failure modes Furthermore, compared with analytical values and experimental values of interaction diagram between moment and shear capacity were safed as it is scattered with outer part of the analytical values.

  • PDF

A Numerical Study on the Stack Effect and the Neutral Plane of a Single Simplified Shaft (단일 단순수직통로의 연돌효과와 중성대에 관한 수치해석 연구)

  • Jeon, Heung-Kyun;Choi, Young-Sang;Choo, Hong-Lok
    • Fire Science and Engineering
    • /
    • v.23 no.5
    • /
    • pp.143-152
    • /
    • 2009
  • The numerical analyses for each single simplified shaft with three type openings were carried out by using computational fluid dynamics model for the calculation of the pressure difference and the location of the neutral plane and the visualization of stack effect. As the height of shaft heighten, the pressure difference of stack effect is much deviated against the theoretical value. For the Type A models shorter than 30 m height of shaft and the Type B models longer than 30m, the simulation results for the location of the neutral plane are well agreed to the theoretical values with 5% less deviations just after the beginning of simulation (t = 10s). For the Type B models longer than 30m with multiple openings, therefore, it is possible to calculate the location of the neutral plane by using a CFD model. The phenomenon of the air flow of stack effect can be easily understood with the visualization of stack effect.

Relationship between the CMOD and the Load-Line Deflection of Concrete (콘크리트의 균열개구 변위와 하중방향 변위관계)

  • 김석기
    • Magazine of the Korea Concrete Institute
    • /
    • v.9 no.1
    • /
    • pp.183-194
    • /
    • 1997
  • Traditional displacmir~nt measurement included an extrancous and cvrntlc. portmn due to test setup and support crushing. The magnitudc of this erroneous deformation was found to be of the same order as the actual displacement, leading to inaccurate determinations of fracture parameters. To overcome this problem, the load-CMOD relationship is a more reliable parameter for determining the fracture characteristics because it is unaffected by the specimen setup and any support crushing. An important step towards the use of load-(:MOD concept as a key fracture parameter depends on relating the CMODto the traditional load-line deflection. This investigation found that there was an unique linear relationship between the CMOD and the load-line deflection. The exact numeric value of relationship between the CMOD and the deflection. that is, the slope ofthe line, is discovered to be a material property. The relationship finds a problem with the existing IZIL,EM recommendations for. measuring the fracture energy of concrete. A proposal to correct the problem is made.

Dynamic Stability Analysis of Tapered Thick Plate according opening position (개구부의 위치변화에 따른 변단면 후판의 동적 안정해석)

  • Kim Il-Jung;Lee Yong-Soo;Oh Soog-Kyoung
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2006.04a
    • /
    • pp.955-962
    • /
    • 2006
  • This paper has the objects of deciding dynamic instability regions of thick plates on Pasternak foundation by finite element method and providing kinematic design data for mats and slabs of building structures. In this paper, dynamic stability analysis of tapered opening thick plate is done by use of Serendipity finite element with 8 nodes considering shearing strain of plate. To verify this finite element method, buckling stress and natural frequencies of thick pate with or without in-plane stress are compared with existing solutions. The results are as follow that this finite element solutions with 4x4 meshes are shown the error of maximum 0.56% about existing solutions, and obtained dynamic instability graph according with variation of opening positions.

  • PDF

The Effects of Shear Capacity on the Locations and Sizes of New Opening in Existing Reinforced Concrete Beams (기존 철근콘크리트 보에서 신설 개구부의 위치와 크기가 전단내력에 미치는 효과)

  • 강민철;이주나;연규원;박찬수
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.10b
    • /
    • pp.891-896
    • /
    • 2000
  • It is necessary to drill new opening in an existing R.C beam either for service ducts and pipes or the determination of in place concrete strength. Therefore, to simulate in this study, 18-R.C beams were fabricated with circular openings. The major parameters considered are the sizes, location of opening and cut-off stirrup. These beams are tested shear failure and capacity under a point loading. The sizes of opening are changed 0.11, 0.2, 0.3 times of beam-depth and the locations of opening are divided into $X_1$ zone, $X_2$ zone, $X_3$zone. Loads are applied up to failure to observe the cracking initiation and propagation, initial diagonal cracking, midspan deflection. As a result, the sizes of opening with 0.11D and 0.2D in R.C beams without cutoff stirrup are profitable in $X_1$ and $X_3$zone. R.C beams with 0.3D and cutoff stirrup are advantageous in $X_3$zone.

Lateral Vibration and Elastic Stability of Rectangular Plates with Cutouts (개구부를 가진 직사각형 평판구조의 진동 및 안정성 해석)

  • 이수곤;김순철;박근흥
    • Computational Structural Engineering
    • /
    • v.3 no.2
    • /
    • pp.77-88
    • /
    • 1990
  • Two perforated plates (a square plate and a rectangular plate having an aspect ratio 1.57(L/sub x/=11, L/sub y/=7)) are taken as analysis examples. Each of these plates is given some changes in the boundary conditions. The size of cutouts as well as their locations are also changed in order to examine the variation of two eigenvalues corresponding to the fundamental mode. The relationship between two eigenvalues is established by changing the magnitude of edge thrust.

  • PDF

Measurement and evaluation of speech privacy in university office rooms (대학 내 사무실의 스피치 프라이버시 측정 및 평가)

  • Lim, Jae-Seop;Choi, Young-Ji
    • The Journal of the Acoustical Society of Korea
    • /
    • v.38 no.4
    • /
    • pp.396-405
    • /
    • 2019
  • The speech privacy of closed office rooms located in a university campus was measured and assessed in terms of SPC (Speech Privacy Class) values. The measurements of two quantities, the LD (Level Difference) between a source and a receiving room, and the background noise level ($L_b$) at the receiving room were carried out in 5 rooms located in 3 different buildings in the university campus. Each of the 5 rooms was adjacent to both offices and corridors through walls. The TL (Transmission Loss) between the source and the receiver room was also measured to compare the difference of two standard methods, ASTM E2836-10 and KS F 2809. The present results show that the speech privacy of the 5 office rooms is not met the requirement for a minimum SPC values of 70. A minimum LD value of 41 dB between the source and the receiver room should be achieved for having a SPC value of 70 when the mean measured value of $L_b$ at the receiving room is 29.2 dB. That is, the TL(avg) value averaged over the octave bands from 160 Hz to 5000 Hz between the source and the receiver room should be or greater than 40 dB. The most important architectural factor influencing the LD value is the presence of openings, such as doors, and windows, on the adjacent walls between the source and receiving room. Therefore, if the opening of the adjacent wall is replaced by an opening with high sound insulation, the appropriate SPC value of the research and office rooms can be achieved.