A Design of Dual-band Microstrip Antenna Loading Inverted-L-shaped Parasitic Elements Vertically at Radiation Apertures for GPS Applications (방사개구면에 역 L형 기생소자를 세운 GPS용 이중대역 마이크로스트립 안테나 설계)

  • Choi, Yoon-Seon;Woo, Jong-Myung
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.14 no.5
    • /
    • pp.38-43
    • /
    • 2015
  • In this paper, we present novel dual-band microstrip antennas using inverted-L-shaped parasitic elements vertically at radiation apertures for GPS L1(1.575 GHz) and L2(1.227 GHz) bands. For making dual band which has large interval, the inverted-L-shaped parasitic element was loaded at the radiation aperture of a half-wavelength patch antenna(GPS L1) in opposite direction of the feeding point for receiving the low frequency(GPS L2). The low frequency occurs by perturbation and coupling between the patch and parasitic. Next, due to use circular polarizations at the GPS applications, two inverted-L-shaped parasitic elements were loaded at radiation apertures of each polarizations and the feeding point was moved at diagonal part of the patch. The dimensions of the designed circularly polarized antenna were $88.5{\times}79{\times}10.4mm^3$ ($0.36{\lambda}L{\times}0.32{\lambda}L{\times}0.04{\lambda}L$, ${\lambda}L$ is the free-space wavelength at 1.227 GHz). Measured -10 dB bandwidths were 116.3 MHz(7.4%) and 64.3 MHz(5.2%) at GPS L1 and L2 bands, respectively. All of these cover the respective required system bandwidths. The measured 3 dB axial ratio bandwidths were 11.7 MHz(0.74%) and 14 MHz(1.14%), respectively. Within each of the designed bands, broadside radiation patterns were observed.

Improvement of Capturing Velocity in the Fume Hood using Computational Fluid Dynamics(I) - Uniform flow (전산유체역학을 이용한 흄후드 제어유속 개선(I) - 균일류)

  • Jung, Jong-Hyeon;Lee, Sang-Woon;Lee, Sang-Man;Shon, Byung-Hyun;Lee, Jung-Hee;Jung, Yu-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.2
    • /
    • pp.962-969
    • /
    • 2013
  • This study used Computational Fluid Dynamics(CFD) to assess the properties of the air current inflow and the flow velocity distribution in the fume hood. In order to verify the effect of improvement, it was also predicted the characteristics of the flow pattern in case the hood face is structurally improved. The assessment of the capture velocity with the existing fume hood confirmed maximum 23 to 30% difference as compared to the root mean square (RMS). And the hood face showed great difference in flow velocity, with the flow velocity in the upper part is 58 to 68% faster than that in the lower part of the hood. So, as a result of the improvement of the hood designed to maintain a steady exhaust at the hood face (that is, installing a baffle on the inner wall and designing the slot type face), a difference of maximum 7% as compared to RMS appeared while maximum 12% differentiation in flow velocity through sections was predicted, showing mitigation of much of the difference in control velocity as compared to the previous structure.

Performance Analysis of the Inversion Schemes in the Spotlight-mode SAR(Synthetic Aperture Radar) (Spotlight-mode SAR(Synthetic Aperture Radar)에서의 Inversion 기법 성능 분석)

  • 최정희
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.40 no.1
    • /
    • pp.130-138
    • /
    • 2003
  • The classical image reconstruction for stripmap-mode Synthetic Aperture Radar is the Range-Doppler algorithm. When the spotlight-mode SAR system was envisioned, Range-Doppler algorithm turned out to fail rapidly in this SAR imaging modality. Thus, what is referred to as Polar format algorithm, which is based on the Plane wave approximation, was introduced for imaging from spotlight-mode SAR raw- data. In this paper, we have studied for the raw data processing schemes in the spotlight-mode Synthetic Aperture Radar. We apply the Wavefront Reconstruction scheme that does not utilize the approximation in spotlight-mode SAR imaging modelity, and compare the performance of target imaging with the Polar format inversion scheme.

Analysis of Coupling Waveguide and Cavity with Lossy Dielectric (도파관과 손실 유전체를 가진 공동의 결합 해석)

  • Jung, Baek-Ho;Lee, Hwa-Yong;Ryu, Ji-Jun;Yoo, Kwang-Yeon;Kim, Jin-Joong
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.2171-2173
    • /
    • 2000
  • 도파관에서 개구를 통하여 공동으로 마이크로파 전력이 전송되는 구조를 시간영역 유한차분법을 이용하여 해석하였다. 공동 내부에는 손실 유전체가 있으며, 결합 개구면으로부터 전달된 전력을 흡수하는 구조이다. 전원인가 방법으로 미소간격 전원과 프릴 전원 기법을 적용하여 해의 타당성을 확인하였다. 도파관과 공동의 크기 및 개구의 형태에 따라서 전장 분포 산출을 시뮬레이션하였다.

  • PDF

Characteristics of a Microstrip Circularly-Polarized Aperture-Patch $8\times8$ Array Antenna (마이크로스트립 원형 편파 개구면-패치 $8\times8$ 배열 안테나의 특성)

  • 김인광;박위상
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.10 no.7
    • /
    • pp.1022-1032
    • /
    • 1999
  • The radiation characteristics of a microstrip circularly-polarized aperture-patch $8\times8$ array antenna are investigated at X-band. The radiator consists of a truncated square aperture on the ground plane with an inclined rectangular patch inside, and it is coupled by a microstrip line on the opposite side of the ground. The element spacing of the array was chosen as $0.8\lambda_0$so as to minimize the mutual coupling and maximize the gain. A corporate feed network was employed to distribute the power to each element through four Wilkinson and two T-junction dividers. Measurement results for the $8\times8$ array at 10 GHz showed a directivity of 26.3 dBi, a gain of 22.2 dBi, an axial ratio of 2.97 dB, and a side lobe level of -12.7dB. It was observed that when the array size increases, the directivity increases while the efficiency decreases.

  • PDF

A Study on the Vented Gas Explosion Characteristics of Indoor Leakage of the LPG (실내 LPG 누출시 폭발특성에 관한 연구)

  • Oh Kyu-hyung;Kim Hong;Kim Sang-sub;Jo Yoong-do;Jo Jee-whan;Oh Shin-kyu
    • Journal of the Korean Institute of Gas
    • /
    • v.3 no.3 s.8
    • /
    • pp.51-57
    • /
    • 1999
  • A study on the vented gas explosion characteristics were carried out with the liquified petroleum gas(LPG) which is used in domestics and industries fuel. To evaluate a damage by gas explosion and to predict a explosion hazards, a series of experiment have been performed in the regular hexahedron vessel of 270${\iota}$. A side of the vessel was made to setting a polyester diaphragm which was ruptured by explosion to simulate an accidental explosion which ruptured the window by explosion. Experimental parameters were LPG concentration, ignition position, venting area, a strength of diaphragm which was ruptured and distances from venting, Experimental results showed that vented gas explosion pressure was more affected by the diaphragm strength than the gas concentration, and the vented gas explosion pressure and blast wave pressure was increased with decreasing the venting area and increasing the strength of diaphragm. In this research we can find that a damage by vented explosion at the outside can be larger than the inside by blast wave pressure near the venting.

  • PDF

Permittivity Characteristic Analysis of Planar Substrates Using H-shaped Resonant Aperture (H-모양 공진 개구를 이용한 평면 기판의 유전율 특성 분석)

  • Yeo, Junho;Lee, Jong-Ig
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2018.05a
    • /
    • pp.55-56
    • /
    • 2018
  • In this paper, a method for analyzing the dielectric constant of a planar substrate is proposed. To this end, a band-stop filter was created by adding a H-shaped resonant aperture to the ground plane of a microstrip transmission line. A planar substrate of 2 mm thickness was placed behind the ground plane of the microstrip transmission line and the change of the resonant frequency with the change of the dielectric constant of the substrate was investigated. It can be seen that the change ratio of the frequency to the reference resonant frequency is larger than that of the conventional complementary split ring resonator structure.

  • PDF

Strength and Initial Stiffness of Composite Beams with a Rectangular Web-Opening (직사각형 웨브 개구부를 가진 합성보의 강도와 초기강성도)

  • 김원기;박노웅;이승준
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.3 no.3
    • /
    • pp.55-62
    • /
    • 1999
  • For the efficient performance of steel and composite building structures subjected to strong earthquake, one of current research investigates the cyclic behavior of open-web composite beams. Both experimental test and nonlinear FEM analysis demonstrate their behavior so ductile that four T-sections around the corners of rectangular web-opening develop plastic hinges prior to potential brittle failure at the beam end, i.e. at the column face. This research proposes simplified equations for determining strength and initial stiffness of composite beams with a rectangular web-opening, and compares its results with those of experimental test and nonlinear FEM analysis.

  • PDF

A study on the characteristics of gas explosion with vent area (밀폐공간에서 파열면에 따른 가스폭발특성에 관한 연구)

  • Kim Sang Sub;Chae Jae Ou;Jo Young Do;Jang Gi Hyun
    • Journal of the Korean Institute of Gas
    • /
    • v.7 no.4 s.21
    • /
    • pp.53-60
    • /
    • 2003
  • Accident occurred by gas explosion in house or building causes damage on lives and properties. To avoid secondary damage, this study drew area ratio of vent area with the experiment for pressure variation with vent area versus building volume by selection of model for different size and shapes of vent area generated by explosion. In addition, Appropriate model was chosen to predict the damage by minimum pressure with the experiment of opening are shapes. This model can prevent secondary damage with the selected vent area and shape to guarantee building safety.

  • PDF

Shielding effectiveness of an Aperture in Infinite Conducting plane Due to HEMP Incidence (무한 도체평판 개구에 입사하는 HEMP 파형에 따른 침투 전자파의 차폐효과)

  • Lim, Byoung-Jin;Seo, Hun-Wook;Lim, Sung-Min;Kim, Ki-Chai
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.8
    • /
    • pp.1647-1652
    • /
    • 2011
  • This paper presents the shielding effectiveness for the IEC 61000-2-9 standard when HEMP source penetrates through an aperture in a planar conducting plane of infinite extent. An integral equation is derived and solved by applying Galerkin's method of moments for calculating the electric shielding effectiveness. The electric shielding effectiveness is examined based on changing the aperture length and width. It is shown that the electric shielding effectiveness is suddenly decreases as the aperture width of 0.4 ~ 0.45${\lambda}$. It is also found that the penetrated electric field for the IEC 61000-2-9 incident field is different from the Bell Laboratory incident field, but the frequency characteristic of the electric shielding effectiveness becomes the same shape.