• Title/Summary/Keyword: 강케이블

Search Result 130, Processing Time 0.041 seconds

Bonding Stress Analysis of Cable Fairings used in Small Guided Missiles and Strength Tests of Bonding Materials (유도무기 케이블 페어링의 강도 해석 및 접착재 강도 시험)

  • Goo, N.-S.;Yoo, K.-J.;Shin, Y.-S.;Lee, Y.-H.;Cheong, H.-Y.;Kim, B.-H.
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.33 no.6
    • /
    • pp.76-82
    • /
    • 2005
  • Cable fairings of guided missiles are generally used for protection of electric cables under aerodynamic heating and mechanical loading. The stress distributions between a cable fairing and missile main body along a cable fairing are necessary for its design. In this paper, a method for bonding stress and strength analysis of a cable fairing has been investigated and its computer program developed. Tensile and three-point bending tests of generally used bonding materials were also conducted to supply basic material properties for design of cable fairings.

Local Fault Detection Technique for Steel Cable using Multi-Channel Magnetic Flux Leakage Sensor (다채널 자속누설 센서를 이용한 강케이블의 국부 단면손상 검색)

  • Park, Seunghee;Kim, Ju-Won;Lee, Changgil;Lee, Jongjae;Gil, Heung-Bae
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.25 no.4
    • /
    • pp.287-292
    • /
    • 2012
  • In this study, Multi-Channel Magnetic Flux Leakage(MFL) sensor - based inspection system was applied to monitor the condition of cables. This inspection system measures magnetic flux to detect the local faults(LF) of steel cable. To verify the feasibility of the proposed damage detection technique, an 8-channel MFL sensor head prototype was designed and fabricated. A steel cable bunch specimen with several types of damage was fabricated and scanned by the MFL sensor head to measure the magnetic flux density of the specimen. To interpret the condition of the steel cable, magnetic flux signals were used to determine the locations of the flaws and the level of damage. Measured signals from the damaged specimen were compared with thresholds set for objective decision making. In addition, the magnetic flux density values measured from every channel were summed to focus on the detection of axial location. And, sum of flux density were displayed with threshold. Finally, the results were compared with information on actual inflicted damages to confirm the accuracy and effectiveness of the proposed cable monitoring method.

Analysis of the cause of breakdown in Underground Transmission cable of Pipe (관로내 송전 XLPE 케이블 고장분석 및 검토)

  • Moon, Kyoung-Hee;Kang, Ji-Won
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.513-514
    • /
    • 2011
  • 본 논문에서는 154kV 지중송전선로의 관로내 XLPE 케이블에서 발생하는 절연파괴 고장원인을 분석하였다. 일반적으로 케이블은 제조공정 과정에서 결함을 철저히 걸러내도록 조치하고 공장 출하시 시험을 통해 점거하고 있어, 케이블 자체고장은 현장에서 시공하는 접속함에 비해 매우 작지만 드물게 발생하고 있다. 케이블 자체에서 고장 발생시 고장원인 파악을 위해 제조 품질, 시공과정 등을 체계적으로 분석하고 검토하여 케이블 생산, 시공현장 품질저하 및 관리소홀 등으로 인한 케이블 고장을 최소화하고자 한다.

  • PDF

Analysis of the cause of insulation breakdown in Transmission cable EB-A (지중송전케이블 기중종단접속함 절연파괴 원인분석)

  • Moon, Kyoung-Hee;Kang, Ji-Won;Kim, Jong-Chae
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.511-512
    • /
    • 2011
  • 본 논문에서는 154kV 지중송전선로의 기중종단접속함 (EB-A)에서 발생한 절연파괴 고장을 분석하여 정확한 원인을 규명하고자 한다. 케이블 결함은 제조 공정에서 철저히 걸러내도록 조치하고 케이블 공장 출하시 시험을 통해 점검하고 있어, 고장은 케이블 자체 보다 현장에서 시공하는 접속함에서 발생할 우려가 매우 크다. 따라서 접속함 시공은 케이블의 안정적인 운전을 위해 매우 중요한 공정으로 접속작업 후 성능이 케이블과 동등 이상의 특성을 유지하도록 하여야 한다.

  • PDF

A Study on Cooling System Basic Design for HTS Power Cable (고온 초전도 전력케이볼의 냉각시스템 설계에 관한 연구)

  • Kim, D.W.;Yang, B.M.;Yoon, H.H.;Kang, J.W.
    • Proceedings of the KIEE Conference
    • /
    • 2008.10a
    • /
    • pp.81-82
    • /
    • 2008
  • 고온초전도 케이블은 초전도 상태를 유지하기 위해서 반드시 액체질소를 이용한 냉각시스템이 필요하다. 액체질소는 순환펌프에 의해 케이블의 유로를 순환하고 케이블을 냉각시키게 된다. 논문에서는 초전도 케이블의 냉각시스템의 기돈 설계에 있어서 중요한 운전온도 운전압력, 열부하에 대해서 고찰하였고, 현재 국내 초전도 케이블의 연구개발에 대해 고찰함으로써 향후 초전도 케이블이 실용화되기 위해 나아가야 할 방향에 대해 제시하였다.

  • PDF

Effects of Cable Rupture on Dynamic Responses of a Concrete Cable-stayed Bridge (케이블 파단이 콘크리트사장교 동적거동에 미치는 영향)

  • Kim, Yu Hee;Go, Hyeong Gyu;Kim, Jae Cheon;Shin, Soobong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.3
    • /
    • pp.84-91
    • /
    • 2012
  • This paper aims to investigate the effects of cable rupture on the dynamic responses of concrete cable-stayed bridges in comparison with those of steel composite ones. It examines an adequate analysis method for simulating cable rupture using a time history function and evaluates the design guidelines for dynamic amplification factor (DAF). The computed DAFs from a concrete cable-stayed bridge are compared with those from a steel composite one based on the design guideline. As a conclusion, the current design guidelines for DAF may be reliable in overall but show some unstable cases despite satisfying the design guidelines, especially for concrete cable-stayed bridges.

Present Status and Accuracy Improvement Plan on Partial Discharge Diagnosis Technology for Underground Transmission Cable (지중 송전케이블 PD진단 기술 현황 및 정확도 향상방안 검토)

  • Jang, Tae-In;Kang, Yeon-Woog;Kang, Ji-Won;Kim, Jong-Chae
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.537-538
    • /
    • 2011
  • 본 논문은 지중송전 XLPE 케이블에 대한 국내외 부분방전(Partial Discharge) 진단기술 현황과 정확도 향상방안을 다룬다. 먼저, 최근의 국내 XLPE 케이블 설치 및 고장 현황을 살펴보고, 국내외 PD진단 동향, PD 진단장비의 특징, 접속부 계면 PD의 주파수 특성을 차례로 알아본다. 마지막으로 이를 종합하여 진단 정확도 향상 방안 및 케이블 고장예방을 위한 향후 연구방향을 제시한다.

  • PDF

Analysis and Review on Effect of Fault Current for an 154kV OF Cable System (고장전류에 의한 OF케이블 영향 분석 및 검토)

  • Jang, Tae-In;Kang, Ji-Won;Yoon, Hyung-Hee;Park, Hung-Sok;Choi, Kyung-Kyu;Kim, Yang-Sang
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.434-435
    • /
    • 2008
  • 본 논문은 지중 송전케이블 사고시 수반되는 고장전류가 케이블에 미치는 영향에 대한 내용을 다룬다. 현재까지 고장전류가 케이블에 미치는 영향에 대해서는 그 중요성에 비하여 구체적인 연구결과물이 미약한 형편이다. 따라서 본 논문에서는 이 분야에 대한 본격적인 연구의 첫 단계로서 단락 고장전류에 의해 발생할 수 있는 종단접속함, 케이블 및 절연 접속부의 현상, 케이블간 작용 전자력, 내부전계 영향, 절연지 특성 등을 분석하였다. 이들 결과는 향후 케이블 고장영향 최소화를 위한 대책수립의 기본 자료로서 활용될 예정이다.

  • PDF

Reliability Test Evaluation in Transmission level HTS Cable (송전급 초전도 케이블의 신뢰성 시험평가 방법)

  • Yang, B.M.;Kim, D.W.;Park, J.W.;Lee, S.Y.;Suk, K.H.;Kim, J.S.;Kim, H.H.;Kang, J.W.
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.379_380
    • /
    • 2009
  • 고온 초전도 전력케이블은 기존 케이블에 비해 많은 전력을 공급할 수 있기 때문에 대용량 신규부하 밀집지역이나 노후 전력케이블 교체시 대용량 송전을 가능하게 하는 대안으로 관심이 많아지고 있다. 그러나 고온 초전도 케이블은 전기적인 특성이나 냉각시스템을 필요로 하는 등 기존 케이블과 다른 많은 특성을 가지고 있기 때문에 실계통에 투입하기 이전에 초전도 케이블의 신뢰성 검증 및 평가가 새롭게 검토해야할 사안들로 받아들여주고 있다. 이를 위해서는 국내외적으로 진행된 많은 고온 초전도 전력케이블에 시험 데이터 및 경험을 근거로 실계통에 적합한 새로운 신뢰성 평가방법을 제시되어야 한다. 본 논문에서는 국내외적으로 진행된 고온 초전도케이블의 신뢰성평가 방법을 검토하고 국내에서 개발중인 세계최고의 전압인 154kV 고온 초전도 전력케이블에 대한 신뢰성 평가방법을 제시하고자 한다.

  • PDF

Evaluation of Cable Impact Factor by Moving Vehicle Load Analysis in Steel Composite Cable-Stayed Bridges (차량 이동하중 해석에 의한 강합성 사장교 케이블의 충격계수 평가)

  • Park, Yong-Myung;Park, Jae-Bong;Kim, Dong-Hyun;Choi, Byung-Ho
    • Journal of Korean Society of Steel Construction
    • /
    • v.23 no.2
    • /
    • pp.199-210
    • /
    • 2011
  • The cables in cable-stayed bridges are under high stress and are very sensitive to vibration due to their small section areas compared with other members. Therefore, it is reasonable to evaluate the cable impact factor by taking into account the dynamic effect due to moving-vehicle motion. In this study, the cable impact factors were evaluated via moving-vehicle-load analysis, considering the design parameters, i.e., vehicle weight, cable model, road surface roughness, vehicle speed, longitudinal distance between vehicles. For this purpose, two steel composite cable-stayed bridges with 230- and 540-m main spans were selected. The results of the analysis were then compared with those of the influence line method that is currently being used in design practice. The road surface roughness was randomly generated based on ISO 8608, and the convergence of impact factors according to the number of generated road surfaces was evaluated to improve the reliability of the results. A9-d.o.f. tractor-trailer vehicle was used, and the vehicle motion was derived from Lagrange's equation. 3D finite element models for the selected cable-stayed bridges were constructed with truss elements having equivalent moduli for the cables, and with beam elements for the girders and the pylons. The direct integration method was used for the analysis of the bridge-vehicle interaction, and the analysis was conducted iteratively until the displacement error rate of the bridge was within the specified tolerance. It was acknowledged that the influence line method, which cannot consider the dynamic effect due to moving-vehicle motion, could underestimate the impact factors of the end-cables at the side spans, unlike moving-vehicle-load analysis.