• Title/Summary/Keyword: 강조 기법

Search Result 655, Processing Time 0.025 seconds

Frequency Range Enhancement for Faster Convergence of Neural Music Source Separation Systems (신경망 기반 음원 분리 시스템의 학습 속도 향상을 위한 음역대 강조 기법)

  • Kim, Min-Seok;Choi, Woo-Sung;Jung, Soon-Young
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2020.05a
    • /
    • pp.567-569
    • /
    • 2020
  • 여러 악기가 섞여 있는 음원으로부터 원하는 악기 소리를 추출하는 음원 분리 기법 중 최근 신경망 기반 시스템이 활발히 연구되고 있다. 악기마다 고유의 음역대를 가진다는 사실에 감안하여, 연구진은 기존 음원 분리 신경망에 적은 수의 학습 파라미터를 추가하여 학습 속도를 대폭 향상시킬 수 있는 음역대 강조 기법을 제안한다.

An effectiveness of multitransmit parallel technique on scan time reduction in hip joint MRI (고관절 자기공명영상 검사 시 multitransmit 기법의 적용에 따른 검사시간 단축의 유용성)

  • Choi, Kwan-Woo;Son, Soon-Yong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.3
    • /
    • pp.103-108
    • /
    • 2016
  • This study examined the effectiveness of the multitransmit parallel technique on the MRI scan time reduction by removing the dielectric effect. The T1 and T2 weighted images of the patients' hip joint were acquired with and without a multitransmit technique. The ROIs were located in the head of femur and iliopsoas muscle. The SNR, CNR and scan time were measured and compared. There was no difference in the images with and without multitransmit. In contrast, the acquisition time was decreased by 42.8% in T1WI and 49.7% in T2WI. In conclusion, this study demonstrated that significant scan time reductions can be accomplished without any differences in the image quality in hip joint MRI by applying the multitransmit parallel technique. Furthermore, the multitranstmit technique is useful in other body parts to resolve the long scan time of an MRI examination.

개선된 영상 처리기법을 이용한 콘크리트 표면 균열 추출 및 분석

  • Lee, Jae-Eon;Kim, Gwang-Baek
    • Proceedings of the Korea Inteligent Information System Society Conference
    • /
    • 2007.05a
    • /
    • pp.365-372
    • /
    • 2007
  • 본 논문에서는 콘크리트 표면 균열 영상에서 균열의 특징들을 추출하기 위하여, 영상 처리 기법을 개선하여 균열의 특징(길이,폭,방향)들을 자동으로 추출 및 분석 할 수 있는 기법을 제안한다. 기존의 영상 처리 기법에서는 비교적 잡음이 적고 균열이 적은 영상을 대상으로 균열을 추출하는 알고리즘을 제시하였기 때문에 많은 잡음과 균열을 가지는 영상에 대해서는 균열 검출 성능이 떨어지는 경향이 있다. 따라서, 본 논문에서 제안한 균열 추출 및 분석 알고리즘은 컬러 영상에서 Histogram Stretching 기법을 적용하여 영상의 콘트라스트 특성을 향상 시킨 후, Robert 연산자를 다시 적용해 균열을 강조하고, 강조된 균열을 Multiple 연산을 이용하여 밝기 차이를 크게 한 후, 개선된 적응 이진화기법을 이용하여 균열의 후보 영역을 추출한다. 추출된 균열 후보 영역을 형상 분석과 위치 및 방향분석을 이용하여 잡음을 제거하고 균열의 특징을 분석한다. 실제 콘크리트 표면 균열 영상을 대상으로 실험한 결과, 균열 검출 성능이 기존의 방법보다 본 논문에서 제안한 방법이 더 우수함을 확인하였다.

  • PDF

Cataract Extraction of Pet Dog using 8 directional Contour Tacking Method (8 방향 윤곽선 추적 기법을 이용한 애견 백내장 추출)

  • Kim, su-Hyeon;Park, Gi-Baek;Song, Doo Heon;Kim, Kwang Beak
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.05a
    • /
    • pp.485-487
    • /
    • 2015
  • 본 논문에서는 애견의 안구 영상을 분석하여 백내장을 추출하는 방법을 제안한다. 제안된 방법은 애견의 영상에서 안구 영역을 선택한 후, 양선형 보간법을 적용하여 선택된 안구 영역을 확대한 후, 퍼지 스트레칭 기법을 적용하여 명암 대비를 강조한다. 강조된 영상에서 이진화 기법과 침식, 팽창기법을 적용하여 잡음 영역을 제거한다. 잡음이 제거된 안구 영역에 8 방향 윤곽선 추적 기법을 적용하여 백내장을 추출한다. 추출된 백내장 부분을 애견의 평균적인 백내장의 크기와 비교 분석하여 백내장 가능성을 도출한다.

  • PDF

Diffusion-Weighted Imaging as a Stand-Alone Breast Imaging Modality (독립적 검사 방법으로서의 확산강조 자기공명영상검사)

  • Hee Jung Shin;Su Hyun Lee;Woo Kyung Moon
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.1
    • /
    • pp.29-48
    • /
    • 2021
  • Diffusion-weighted magnetic resonance imaging (DW MRI) is a fast unenhanced technique that shows promise as a stand-alone modality for cancer screening and characterization. Currently, DW MRI may have lower sensitivity than that of dynamic contrast-enhanced MRI as a standalone modality for breast cancer detection but superior to that of mammography, which may provide a useful alternative for supplemental screening. Standardized acquisition and interpretation of DW MRI can improve the image quality and reduce the variability of the results. Furthermore, high-resolution DW MRI, with advanced techniques and postprocessing, will facilitate better detection and characterization of subcentimeter cancers and reduce false-negatives and false-positives. Future results from ongoing prospective multicenter clinical trials using standardized and optimized protocols will facilitate the use of DW MRI as a stand-alone modality.

Comparative Analysis of Signal Intensity and Apparent Diffusion Coefficient at Varying b-values in the Brain : Diffusion Weighted-Echo Planar Image ($T_2^*$ and FLAIR) Sequence (뇌의 확산강조 영상에서 b-value의 변화에 따른 신호강도, 현성확산계수에 관한 비교 분석 : 확산강조 에코평면영상($T_2^*$ 및 FLAIR)기법 중심으로)

  • Oh, Jong-Kap;Im, Jung-Yeol
    • Journal of radiological science and technology
    • /
    • v.32 no.3
    • /
    • pp.313-323
    • /
    • 2009
  • Diffusion-weighted imaging (DWI) has been demonstrated to be a practical method for the diagnosis of various brain diseases such as acute infarction, brain tumor, and white matter disease. In this study, we used two techniques to examine the average signal intensity (SI) and apparent diffusion coefficient (ADC) of the brains of patients who ranged in age from 10 to 60 years. Our results indicated that the average SI was the highest in amygdala (as derived from DWI), whereas that in the cerebrospinal fluid was the lowest. The average ADC was the highest in the cerebrospinal fluid, whereas the lowest measurement was derived from the pons. The average SI and ADC were higher in $T_2^*$-DW-EPI than in FLAIR-DW-EPI. The higher the b-value, the smaller the average difference in both imaging techniques; the lower the b-value, the greater the average difference. Also, comparative analysis of the brains of patients who had experienced cerebral infarction showed no distinct lesion in the general MR image over time. However, there was a high SI in apparent weighted images. Analysis of other brain diseases (e.g., bleeding, acute, subacute, chronic infarction) indicated SI variance in accordance with characteristics of the two techniques. The higher the SI, the lower the ADC. Taken together, the value of SI and ADC in accordance with frequently occurring areas and various brain disease varies based on the b-value and imaging technique. Because they provide additional useful information in the diagnosis and treatment of patients with various brain diseases through signal recognition, the proper imaging technique and b-value are important for the detection and interpretation of subacute stroke and other brain diseases.

  • PDF

Applying Information and Communication Technology for Advancing Educational Assessment (교육 평가의 혁신을 위한 테크놀러지의 활용)

  • Park, Joo-Yong
    • Proceedings of the Korean Society for Cognitive Science Conference
    • /
    • 2005.05a
    • /
    • pp.112-121
    • /
    • 2005
  • 평가는 교수와 함께 교육 목표를 이루는데 있어 핵심적인 역할을 한다. 그렇지만 평가는 교수법의 발전 속도에 비교하면 상당히 느릴 뿐만 아니라, 교사는 물론 학생들에게 부정적으로 비추어지고 있다. 본 논문에서는 시험이 학생들을 동기화시킬 뿐만 아니라 그 자체로 중요한 학습 경험임을 강조하면서, 학습을 위한 평가를 활성화시키기 위해 테크놀러지를 이용한 평가 방식들을 소개하였다. 개발을 물론 어느 정도 연구가 이루어진 테크놀러지를 활용한 평가 기법을, 수행평가와 선다형의 개선안으로 대별하였다. 수행평가를 위한 기법에서는 논술채점, 지식 지도 제작법, 그리고 학습자 모형을 이용한 평가기법이, 선다형의 개선안으로 적응형 컴퓨터화 검사, 다중평가 및 변형선다형 방식이 각각 상술되었다. 결론에서는 평가를 통한 교육 효과를 극대화하기 위해서는, 교사는 물론 학생들의 평가에 대한 태도 변화 교육과 실제 교육 현장에서 쉽게 활용될 수 있는 컴퓨터를 이용한 평가기법의 개발과 보급의 중요성이 강조되었다.

  • PDF

Extraction of Intima and Adventitia using Bezier Curve on IVUS Image (IVUS 영상에서 베지어 곡선을 이용한 내막과 외막 추출)

  • Moon, A-Seong;Kim, Yeong-Wan;Kang, Yong Hoon;Kim, Kwang-Baek
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2020.01a
    • /
    • pp.29-31
    • /
    • 2020
  • 제안된 방법은 외막의 경계선을 추출하기 위해 Max-Min 이진화를 적용하여 외막을 추출 한 후에 삼각 함수의 각도 값을 이용하여 외막의 경계점을 추출한다. 추출한 경계점들을 Bezier Curve 기법을 적용하여 외막의 경계점들을 연결하여 외막의 경계선을 추출한다. 그리고 내막 영역을 추출하기 위해 외막 영역을 ROI 영역으로 추출한다. 추출된 ROI 영역을 오목 파라볼라 기법을 적용하여 내막의 영역을 강조한다. 내막영역이 강조된 ROI 영역에 평균 이진화를 적용하여 내막의 영역을 추출한다. 추출된 영역에서 잡음을 제거하기 위해 내막 영역만 Labeling 기법을 적용한다. 제안된 방법을 IVUS 영상을 대상으로 실험한 결과, 내막과 외막간의 포함관계의 정도에 따라 환자의 수술 여부 결정에 대한 외막과 내막의 각 넓이 정보를 개관적으로 제공할 수 있는 가능성을 확인하였다.

  • PDF

Effectiveness of a fast spin echo technique using the signal void in acquisition of black blood images (흑혈류영상 획득 시 신호소실을 활용한 고속스핀에코기법의 유용성)

  • Choi, Kwan-Woo;Kim, Yoon-Shin;Son, Soon-Yong;Lee, Hee-Ju;Min, Jung-Whan;Lee, Jong-Seok;Yoo, Beong-Gyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.9
    • /
    • pp.4313-4319
    • /
    • 2013
  • The purpose of our study is to shorten the scanning time and minimize the inconveniences of the patients in acquisition of the black blood images using the signal void effect in the fast spin echo technique while keeping the diagnostic value of the test. Thirty-two consecutive patients who underwent black blood MR imaging were examed with additional double inversion recovery (DIR) sequence and the conventional fast spin echo (FSE) sequence. Signal to Noise Ratio (SNR) and Contrast to Noise Ratio (CNR) of the internal carotid arteries' lumen were compared in T1 and T2 weighted images to determine whether there are differences between the two techniques for depiction of the signal void effect inside the vessel wall. The FSE images showed lower SNR values than the DIR images in both of the T1 and T2 weighted images (11.49% and 13.66% respectively). While the CNR values were higher in the FSE images than in the DIR images in both of the T1 and T2 weighted images (8.69% and 7.55% respectively).There was no significant difference between the two techniques for either of the SNR or CNR (p>0.05, p>0.05 respectively). The DIR and the FSE images demonstrated almost identical imaging patterns. Therefore, it is anticipated that the use of FSE technique in acquisition of the black blood imaging could reduce the inconveniences of the patients during the scanning and minimize exam time while keeping the diagnostic value of the test.

Development of the Line Scan Diffusion Weighted Imaging at Low Tesla Magnetic Resonance Imaging System (저자장 자기공명영상시스템에서 선주사확산강조영상기법 개발)

  • Hong, Cheol-Pyo;Lee, Dong-Hoon;Lee, Do-Wan;Lee, Man-Woo;Paek, Mun-Young;Han, Bong-Soo
    • Journal of the Korean Society of Radiology
    • /
    • v.2 no.2
    • /
    • pp.31-38
    • /
    • 2008
  • Line scan diffusion weighted imaging (LSDI) pulse sequence for 0.32 T magnetic resonance imaging (MRI) system was developed. In the LSDI pulse sequence, the imaging volume is formed by the intersection of the two perpendicular planes selected by the two slice-selective $\pi$/2-pulse and $\pi$-pulse and two diffusion sensitizing gradients placed on the both side of the refocusing $\pi$-pulse and the standard frequency encoding readout was followed. Since the maximum gradient amplitude for the MR system was 15 mT/m the maximum b value was $301.50s/mm^2$. Using the developed LSDI pulse sequence, the diffusion weighted images for the aqueous NaCl solution phantom and triacylglycerol solution phantom calculated from the line scan diffusion weighted images gives the same results within the standard error range (mean diffusivities = $963.90{\pm}79.83({\times}10^{-6}mm^2/s)$ at 0.32 T, $956.77{\pm}4.12({\times}10^{-6}mm^2/s)$ at 1.5 T) and the LSDI images were insensitive to the magnetic susceptibility difference and chemical shift.

  • PDF