• Title/Summary/Keyword: 강재케이블

Search Result 25, Processing Time 0.022 seconds

Load Transfer Characteristics of the 7-wire strand using FBG Sensor Embedded Smart Tendon (FBG센서가 내장된 스마트 텐던을 이용한 7연 강연선의 인발 하중전이 특성)

  • Kim, Young-Sang;Suh, Dong-Nam;Kim, Jae-Min;Sung, Hyun-Jong
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.9 no.5
    • /
    • pp.79-86
    • /
    • 2009
  • With the substantial increase of the size of structure, the management of excavation becomes more difficult. Therefore, massive collapses which are related to retaining wall recently increase. However, since the study on measuring and monitoring the pre-stressing force of anchor is insufficient, behavior of anchor may not be predicted and monitored appropriately by the existing strain gauge and load cell type monitoring system. FBG Sensor, which is smaller than strain gauge and has better durability and does not have a noise from electromagnetic waves, is adapted to measure the strain and pre-stressing force of 7-wire strand, so called smart tendon. A series of pullout tests were performed to verify the feasibility of smart tendon and find out the load transfer mechanism around the steel wire tendon fixed to rock with grout. Distribution of measured strains and estimated shear stresses are compared with those predicted by theoretical solutions. It was found that developed smart tendon can be used effectively for measuring strain of 7-wire strand anchor and theoretical solutions underestimate the magnitude of shear stress and load transfer depth.

Optimization of Arc-Start Performance by Digital Controlled Wire Feeding System (디지털 제어형 와이어 송급 시스템에서의 Arc-Start 성능 최적화)

  • Ryu, Gyeong-Su;Kim, Dong-Cheol;Kang, Mun-Jin;Rhee, Se-Hun
    • Proceedings of the KWS Conference
    • /
    • 2009.11a
    • /
    • pp.21-21
    • /
    • 2009
  • 현장의 GMA 용접기는 일반적으로 용접기 본체로부터 와이어 송급장치까지의 거리가 약 50m 정도 떨어져 있고 송급장치로부터 토치까지의 거리는 약 3~5m 정도이다. 특히 국산 GMA 용접기의 와이어 송급장치는 DC 모터의 일종인 프린트모터를 사용하고 있으며 제어기는 오픈루프 제어를 하고 있다. 따라서 와이어 송급속도의 변동을 보상할 수 있는 어떤 수단도 장착되어 있지 않다. 또한 송급장치와 토치간 와이어를 안내하는 케이블 도관의 마찰 때문에 토치 끝단에서의 와이어 송급속도가 불규칙해질 수밖에 없다. 용접 시 와이어 송급속도의 순간적인 변동 때문에 용접부의 전류 파형이 매우 불규칙해지고 이 때문에 용융된 용적이 용융풀로 이행하지 못하고 스패터로 비산하는 현상을 발생시킨다. 본 연구에서는 이를 해결하고자 국산 SCR 용접기 및 인버터 용접기와 호환 가능한 디지털 제어형 와이어 송급장치와 Push-Pull 용접 토치를 개발하였다. 또한, 개발된 시스템을 이용하여 정 역 방향 제어기술을 적용하였고 아크 발생 시의 스패터 최소화 공정을 제안하였다. 실험은 SM490A 강재를 사용하여 BOP(Bead On Plate) 용접을 실행하였다. 용접 중 LabVIEW를 이용하여 아크 발생 초기 전류, 전압 그리고 와이어 송급속도를 측정하였고, 고속 카메라를 이용하여 용접현상을 분석하였다. 본 연구를 통해 아크 발생 초기의 스패터를 최소화하는 공정을 도출할 수 있었다. 용접공정 변수인 아크 발생 초기의 와이어 송급속도, 와이어의 역송급 진행거리 그리고 역송급 판단 시점의 용접 전류 값은 실험을 통해 얻을 수 있었다. 또한, 이 연구를 통해 개발된 시스템의 성능을 평가하였다.

  • PDF

Permeability of Magnetic Flux of PS Steel for Variation of Stress and Temperature (긴장재의 응력 및 온도변화에 따른 자속투과율)

  • Park, Jin Su;Kim, Byeong Hwa
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.42 no.3
    • /
    • pp.323-331
    • /
    • 2022
  • An experimental study was conducted to investigate the effect of applied tensile force and temperature on the permeability of magnetic flux in prestressing steel. The permeability of magnetic flux is the ratio at which the magnetic flux between two points passes. The prestressing steel used in these experiments included a 7-mm PS wire mainly used for cable-stayed bridges and a 12.7-mm PS strand for prestressed concrete bridges. The experiments to extract the permeability of the magnetic flux of steel wire and strand were conducted under various tensile levels and temperature conditions. From the experimental results, it was observed that the permeability of magnetic flux of the PS tension material was linearly proportional to the applied tensile stress level, and inversely proportional to the temperature. If the experimental relationship among the magnetic permeability, temperature, and prestressing ratio of a PS tension material is known in advance, the current tension stress level on PS members can be evaluated by measuring solely the magnetic permeability and temperature.

Dynamic Behavior of Submerged Floating Tunnel by Underwater Explosion (수중폭발에 의한 해중터널의 동적거동)

  • Hong, Kwan-Young;Lee, Gye-Hee;Lee, Seong-Lo
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.31 no.5
    • /
    • pp.215-226
    • /
    • 2018
  • In this paper, to estimate the dynamic behavior of a submerged floating tunnel(SFT) by underwater explosion(UE), the SFT is modeled and analyzed by the explicit structural analysis package LS-DYNA. The section of SFT near to explosion point is modeled to shell and solid elements using elasto-plasticity material model for concrete tubular section and steel lining. And the other parts of the SFT are modeled to elastic beam elements. Also, mooring lines are modeled as tension-only cable elements. Total mass of SFT is including an added mass by hydrodynamic effect. The buoyancy on the SFT is considered in its initial condition using a dynamic relaxation method. The accuracy and the feasibility of the analysis model aree verified by the results of series of free field analysis for UE. And buoyancy ratio(B/W) of SFT, the distance between SFT and an explosion point and the arrangement of mooring line aree considered as main parameters of the explosion analysis. As results of the explosion analysis, the dynamic responses such as the dent deformation by the shock pressure are responded less as more distance between SFT and an explosion point. However, the mooring angle of the diagonal mooring system can not affect the responses such as the horizontal displacement of SFT by the shock pressure.

Development and Characterization of High Frequency Ultrasonic Transducer Using PVDF and P(VDF-TrFE) (PVDF 및 P(VDF-TrFE)를 이용한 고주파수 수침용 초음파 탐촉자 개발 및 평가)

  • Kim, Ki-Bok;Kim, Byoung-Geuk;Lee, Seung-Seok
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.22 no.1
    • /
    • pp.1-8
    • /
    • 2002
  • The high frequency ultrasonic transducers using polyvinyliden fluoride(PVDF) and polyvinylidene fluoride trifluorethyylene(P(VDF-TrFE)) were developed. The characteristics of fabricated high frequency ultrasonic transducer such as beam diameter, high frequency ultrasonic detection field and amplitude of the first pulse echo signal from the test target in the water were analyzed. The high frequency ultrasonic detection field was affected by the length of coaxial cable between high frequency transducer and ultrasonic pulser/receiver. As the size of the test target increased, the high frequency detection field decreased and the amplitude of a reflection signal increased. The peak amplitude of the first pulse echo signal of P(VDF-TrFE) transducer was higher than that of PVDF transducer. The high frequency ultrasonic detection field of PVDF transducer was wider than that of P(VDF-TrFE) transducer. With C-scan testing, the developed high frequency ultrasonic transducer could detect the 30 to $100{\mu}m$ of hydrogen induced crack of steel specimen by C-scan testing.