• Title/Summary/Keyword: 강인 제어기

Search Result 1,016, Processing Time 0.022 seconds

Effects of aminoethoxyvinylglycine (AVG) and 1-methylcyclopropene (1-MCP) treatments on fruit quality attributes in cold-stored 'Jonathan' apples (수확 후 aminoethoxyvinylglycine(AVG)와 1-methylcyclopropene(1-MCP) 처리가 '홍옥' 사과의 저온저장 중 과실품질에 미치는 영향)

  • Park, Jun-yeun;Kim, Kyoung-ook;Yoo, Jingi;Win, Nay Myo;Lee, Jinwook;Choung, Myoung-Gun;Jung, Hee-Young;Kang, In-Kyu
    • Food Science and Preservation
    • /
    • v.23 no.4
    • /
    • pp.453-458
    • /
    • 2016
  • 'Jonathan' apples are relatively small size which contributes to enhancing fruit consumption and gaining popularity. Thus, this study was carried out to evaluate the effects of AVG (aminoethoxyvinylglycine, ReTain$^{(R)}$), sprayable 1-MCP (1-methylcyclopropene, Harvista$^{TM}$), and fumigation 1-MCP (SmartFresh$^{TM}$) applications on fruit quality attributes and storability in 'Jonathan' apple fruits during cold-stored. The Jonathan fruits were dipped with either ReTain (75 mg/L) or Harvista (125 mg/L) solutions for 5 min, or fumigated with SmartFresh (1 mg/L) for 18 hr before storage at $0{\pm}1^{\circ}C$ for 75 days. Flesh firmness and titratable acidity remained higher in all pre-treated apples than control ones during cold storage period. Flesh firmness was higher for apples treated with ReTain and SmartFresh than samples treated with Harvista, while soluble solid content and respiration rate were not affected by sample pretreatment. Internal ethylene concentration (IEC) of all pretreated apples remained below about $4.5{\mu}L/L$ during the entire storage period while that of control sample greatly increased to $10.29{\mu}L/L$. Ethylene production was much higher in control fruits than in treated ones during cold storage. These results indicated that ReTain and 1-MCP treatments would be considerably effective in retention of fruit quality attributes of 'Jonathan' apple during cold-stored.

Comparison of the Result of Radiation Alone and Radiation with Daily Low Dose Cisplatin in Management of Locally Advanced Cervical Cancer (국소적으로 진행된 자궁경부암에서 방사선 단독치료와 방사선 및 저용량 Cisplatin 항암화학요법 병용치료의 비교)

  • Kim Hun Jung;Kim Woo Chul;Lee Mee Jo;Kim Chul Su;Song Eun Seop;Loh John J K.
    • Radiation Oncology Journal
    • /
    • v.22 no.3
    • /
    • pp.200-207
    • /
    • 2004
  • Purpose: An analysis was to compare the results of radiation alone with those of radiation with dally low dose cisplatin as a radiation sensitizer in locally advanced cervical cancer. Materials and Methods: A retrospective analysis of 59 patients diagnosed with locally advanced uterine cervix cancer between December 1996 and March 2001 was peformed. Thirty one patients received radiation alone and 28 patients received dally low dose cisplatin, as a radiation sensitizer, and radiation therapy. The median follow-up period was 34 months, ranging from 2.5 to 73 months. The radiation therapy consisted of 4500 cGy external beam irradiation to the whole pelvis (midline block after 3060 cGy), a 900$\~$l,000 cGy boost to the involved parametrium and high dose-rate intracavitary brachytherapy (a total dose of 3,000$\~$3,500 cGy/500 cGy per fraction to point A, twice per week). In the chemoradiation group, 10 mg of daily intravenous cisplatin was given daily from the 1st day of radiation therapy to the 20th day of radiation therapy. According to the FIGO classification, the patients were subdivided into 51 (86.4$\%$) and 8 (13.6$\%$) stages IIB and stage IIIB, respectively. Results: The overall 5 year survival rate was 65.65$\%$ and according to treatment modality were 56.75$\%$ and 73.42$\%$ in the radiation alone and chemoradiation groups, respectively (p=0.180). The 5 year disease-free survival rates were 49.39$\%$ and 63.34$\%$ in the radiation alone and chemoradiatoin groups, respectively (p=0.053), The 5 year locoregional control rates were 52.34$\%$ and 73.58$\%$ in the radiation alone and chemoradiation groups, respectively (p=0.013). The 5 year distant disease-free survival rates were 59.29$\%$ and 81.46$\%$ in the radiation alone and chemoradiation groups, respectively (p=0.477), Treatment related hematologic toxicity were prominent in the chemoradiation group. Leukopenia $\geq$grade) occurred in 3.2$\%$and 28.5$\%$ of the radiation alone and chemoradiation groups, respectively (p=0.02). There were no statistical differences in the incidences of vesical, rectal and small bowel complications between two groups. Conclusion: Radiation therapy with low dose cisplatin did not improve the rates of survival and response rates, but did improve the rate of disease free survival and locoregional control rates In locally advanced cervical cancer. The incidence of bone marrow suppression was higher in the chemoradiation group.

Interstitial Vaginal Needle Implantation in Gynecological Tumors : Design and Construction of Applicator (부인과암에서 조직내 삽입 방사선치료 - Applicator의 고안 및 제작-)

  • Kang, Seung-Hee;Chun, Mi-Son;Kang, Hae-Jin;Jung, Chil;Son, Jeong-Hyae
    • Radiation Oncology Journal
    • /
    • v.16 no.2
    • /
    • pp.167-175
    • /
    • 1998
  • Purpose : It is not a simple task to achieve the ideal isodose curve with a standard vaginal applicator or sing1e plane needle impant in the paravaginal tissue when primary or recurrent gynecological neoplasms(cervical cancers, vaginal cancers and vulvar cancers) are treated as a boost following external beam radiotherapy. The authors introduce the development and construction of a simple, inexpensive, customized applicator for volume implant to maximize the radiation dose to the tumor while minimizing the dose to the rectum and the bladder. Materials and Methods : Nine patients underwent Ir-192 transperineal interstitial implantation for either recurrent(5 cases) or primary(3 cases) cervical cancers or primary vaginal cancer(1 case) between August 1994 and February 1998 at Ajou university hospital. First 3 cases were performed with a sing1e plane implant guided by digital palpation. Because of inadequate isodose coverage in the tumor volume in first 3 cases, we designed and constructed interstitial vaginal applicator for volume implant to improve tumor dose distribution and homogeneity while sparing the surrounding normal tissue. Our applicators consist of vaginal obturator and perineal template that made of the clear acrylamide and dental mold material$(Provil^{(R)})$. The applicators were customized individually according to the tumor size and its location Both HDR and LDR irradiation were given with these applicators accomodating 6 Fr needles(Microselectron Nucletron). The pretreatment planning prior to actual implant was performed whenever possible. Results : Needles can be inserted easily and evenly into the tumor volume through the holes of templates, requiring less efforts and time for the implant procedure. Our applicators made of materials available from commercial vendors. These have an advantage that require easy procedure, and spend relatively short time to construct. Also it was possible to fabricate applicators to individualize according to the tumor size and its location and to achieve the ideal isodose coverage. We found an accurate needle arrangement and ideal dose distribution through the CT scan that was obtained in 3 cases after needle implant. Three patients with primary cervical and vaginal cancers were controlled locally at final follow up. But all recurrent cases failed to do so. Conclusion : The authors introduce inexpensive, simple interstitial vaginal templates which were self-designed and constructed using materials available from commercial vendors such as acrylanide and dental mold material $(Provil^{(R)})$.

  • PDF

Study of Quality Control of Traditional Wine Using IT Sensing Technology (IT 센싱 기술을 이용한 전통주 발효의 품질관리 연구)

  • Song, Hyeji;Choi, Jihee;Park, Chan-Won;Shin, Dong-Beom;Kang, Sung-Soo;Oh, Sung Hoon;Hwang, Kwontack
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.44 no.6
    • /
    • pp.904-911
    • /
    • 2015
  • The objective of this study was to investigate the quality characteristics of traditional wine using an radio-frequency identification (RFID) system annexed to a fermenter. In this study, we proposed an RFID-based data transmission scheme for monitoring fermentation of traditional alcoholic beverages. The pH, total acidity, total sugar, soluble sugar, free sugar, alcohol content, and organic acids of were investigated and subjected to fermentation of traditional alcoholic beverages three times. The pH ranged from 7.98, 7.95, and 7.68 at day 0, decreased drastically to 3.31~2.96 at day 2, and then slowly increased to the end point, finally reaching 3.34 at day 20. Acidity tended to increase quickly with time, especially for all samples after day 2. The fermentation environment induced a sudden increase acidity in reactants and indicated a low pH. The total sugars during fermentation quickly decreased to the range of 20.3, 22.43, and 19.2% at day 2, and the slope of reduction steadily decreased to 5.1, 6.1, and 4.8% at day 10. On the other hand, the alcohol content showed the reverse trend as total sugars. The alcohol content also showed the same pattern as total acids, showing the highest alcohol content of 17.3% (v/v) on day 20. In this study on traditional wine fermentation using an RFID system, we showed that pH, soluble sugar, and alcohol content can be adopted as key indicators for quality control and standardization of traditional wine manufacturing.

Application of deep learning method for decision making support of dam release operation (댐 방류 의사결정지원을 위한 딥러닝 기법의 적용성 평가)

  • Jung, Sungho;Le, Xuan Hien;Kim, Yeonsu;Choi, Hyungu;Lee, Giha
    • Journal of Korea Water Resources Association
    • /
    • v.54 no.spc1
    • /
    • pp.1095-1105
    • /
    • 2021
  • The advancement of dam operation is further required due to the upcoming rainy season, typhoons, or torrential rains. Besides, physical models based on specific rules may sometimes have limitations in controlling the release discharge of dam due to inherent uncertainty and complex factors. This study aims to forecast the water level of the nearest station to the dam multi-timestep-ahead and evaluate the availability when it makes a decision for a release discharge of dam based on LSTM (Long Short-Term Memory) of deep learning. The LSTM model was trained and tested on eight data sets with a 1-hour temporal resolution, including primary data used in the dam operation and downstream water level station data about 13 years (2009~2021). The trained model forecasted the water level time series divided by the six lead times: 1, 3, 6, 9, 12, 18-hours, and compared and analyzed with the observed data. As a result, the prediction results of the 1-hour ahead exhibited the best performance for all cases with an average accuracy of MAE of 0.01m, RMSE of 0.015 m, and NSE of 0.99, respectively. In addition, as the lead time increases, the predictive performance of the model tends to decrease slightly. The model may similarly estimate and reliably predicts the temporal pattern of the observed water level. Thus, it is judged that the LSTM model could produce predictive data by extracting the characteristics of complex hydrological non-linear data and can be used to determine the amount of release discharge from the dam when simulating the operation of the dam.

Results of Radiation Therapy for Carcinoma of the Uterine Cervix (자궁경부암의 방사선치료 성적)

  • Lee Kyung-Ja
    • Radiation Oncology Journal
    • /
    • v.13 no.4
    • /
    • pp.359-368
    • /
    • 1995
  • Purpose : This is a retrospective analysis for pattern of failure, survival rate and prognostic factors of 114 patients with histologically proven invasive cancer of the uterine cervix treated with definitive irradiation. Materials and Methods : One hundred fourteen patients with invasive carcinoma of the cervix were treated with a combination of intracavitary irradiation using Fletcher-Suit applicator and external beam irradiation by 6MV X-ray at the Ewha Womans University Hospital between March 1982 and Mar 1990. The median age was 53 years(range:30-77 years). FIGO stage distribution was 19 for IB, 23 for IIA, 42 for IIB, 12 for IIIA and 18 for IIIB. Summation dose of external beam and intracavitary irradiation to point A was 80-90 Gy(median:8580 cGy) in early stage(IB-IIA) and 85-100 Gy(median:8850 cGy) in advanced stage(IIB-IIIB). Kaplan-Meier method was used to estimate the survival rate and multivariate analysis for progrostic factors was performed using the Log likelihood for Weibull Results : The pelvic failure rates by stage were $10.5{\%}$ for IB. $8.7{\%}$ for IIA, $23.8{\%}$ for IIB, $50.0{\%}$ for IIIA and $38.9{\%}$ for IIIB. The rate of distant metastasis by stage were $0{\%}$ for IB, $8.7{\%}$ for IIA, $4.8{\%}$ for IIB. $0{\%}$ for IIIA and $11.1{\%}$ for IIIB. The time of failure was from 3 to 50 months and with median of 15 months after completion of radiation therapy. There was no significant coorelation between dose to point A($\leq$90 Gy vs >90 Gy) and pelvic tumor control(P>0.05). Incidence rates of grade 2 rectal and bladder complications were $3.5{\%}$(4/114) and $7{\%}$(8/114), respectively and 1 patient had sigmoid colon obstruction and 1 patient had severe cystitis. Overall 5-year survival rate was $70.5{\%}$ and disease-free survival rate was $53.6{\%}$. Overall 5-year survival rate by stage was $100{\%}$ for IB, $76.9{\%}$ for IIA, $77.6{\%}$ for IIB $87.5{\%}$ for IIIA and $69.1{\%}$ for IIIB. Five-rear disease-free survival rate by stage was $81.3{\%}$ for IB, $67.9{\%}$ for IIA, $46.8{\%}$ for IIB, $45.4{\%}$ for IIIA and $34.4{\%}$ for IIIB. The prognostic factors for disease-free survival rate by multivariate analysis was performance status(p= 0.0063) and response rate after completion of radiation therapy(p= 0.0026) but stage, age and radiation dose to point A were not siginificant. Conclusion : The result of radiation therapy for early stage of the uterine cervix cancer was relatively good but local control rate and survival rate in advanced stage were poor inspite of high dose irradiation to point A above 90 Gy. Prospective randomized studies are recommended to establish optimal tumor doses for various stages and volume of carcinoma of uterine cervix, And ajuvant chemotherapy or radiation-sensitizing agents must be considered to increase the pelvic control and survival rate in advanced cancer of uterine cervix.

  • PDF