• Title/Summary/Keyword: 강우침투

Search Result 565, Processing Time 0.034 seconds

In-situ Monitoring of Matric Suctions in a Weathered Soil Slope (풍화토 사면에서 강우로 인한 간극수압 변화에 대한 실험연구)

  • 이인모;조우성;김영욱;성상규
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.1
    • /
    • pp.41-49
    • /
    • 2003
  • Rainfall-induced landslides in a weathered granite soil slope usually happen on shallow slip surfaces above the groundwater table. The pore-water pressure of soil above the groundwater table is usually negative. This negative pore-water pressure (or matric suction) has been found to make a large contribution to the slope stability. Therefore, the variation of in-situ matric suction profiles with time elapse in a soil slope should be understood. In this study, a field measurement program was carried out from June to August, 2001 in order to monitor in-situ matric suctions and volumetric water contents in a weathered granite soil slope. Finite-element transient seepage analyses are also conducted using SEEP/W. The influence of climatic conditions on the variation of in-situ matric suctions could be found to decrease rapidly with the change of depth. It could be found that decrement of matric suction induced by precipitation is affected not only by the amount and duration of rainfalls but also by the initial matric suction just prior to rainstorms. The soil-water characteristic from the field monitoring tends toward the wetting path of SWCC obtained from the laboratory test.

Study on Rainfall infiltration Characteristics for Weathered Soils: Analysis of Soil Volumetric Water Content and Its Application (국내 풍화토의 강우 침투특성 분석을 위한 실험연구: 토양 체적함수비 분석 및 적용성 평가)

  • Kim, Man-Il;Chae, Byung-Gon;Cho, Yong-Chan;Seo, Yong-Seok
    • The Journal of Engineering Geology
    • /
    • v.18 no.1
    • /
    • pp.83-92
    • /
    • 2008
  • In order to analyze infiltration characteristics of rainfall in soil, two laboratory experiments were conducted using an amplitude domain reflectometry (ADR) sensor and a pore water pressure meter (PWP) in this study. The first experiment is to understand the dependency of volumetric water content and temperature for standard sand and weathered granite soil. The second experiment is a laboratory flume test with changes of rainfall condition. As the results of the dependency experiment, the volumetric water content is increased with increase of the output voltage measured by the ADR sensor in both the standard sands and weathered granite soil. Furthermore, the results also indicate necessity of consideration of the temperature dependency under the condition of high volumetric water contents from 0.15 to 0.45. In the flume test, two measurement devices are detected to the variation of volumetric water content and pore water pressure at the installation point of the flume. In especial, the measured values of ADR4 and PWP3 installed on the lower part of slope are higher than those of the others. It means that the lower part of slope plays a role of a runoff face and a beginning point of slope failure.

An Experimental Study of Runoff Reduction Using Infiltration Facility (건축물에 적용된 우수침투시설의 유출저감효과에 관한 실험적 연구)

  • Park Jae-Roh;Kwon Hyok
    • Journal of Soil and Groundwater Environment
    • /
    • v.10 no.5
    • /
    • pp.37-44
    • /
    • 2005
  • The main object of this study is to develop the infiltration facility that it can be used in grounds, parking areas, roads, pathway, housing etc. As a result, it is much alike in the infiltration method of facility to use permeable concrete, permeable hole and be filled with broken stones. And through this experiment, it was perceived the truth that the state of ground, the groundwater level, buildings around them, the history of submerging and the applicable infiltration facilities are the key. To verify how much the infiltration facility reduce the outflow, we set up the infiltration facility in the test area. In result, it reduced the outflow 89% in 24 mm rainfall, 93% in 12 mm, 51% in 140 mm, 75% in 64 mm and 80% in 54 mm. As the rainfall rate increased, the infiltration increased up to the limited rainfall. And in the limited rainfall, we knew that the infiltration was reduced suddenly. Infiltration is closely related to the state of ground, the rain interval etc. and we will analyze these conditions through the continuous monitoring.

An Experimental Study on Infiltration Characteristics of Facilities for Reducing Runoff Considering Surface Materials According to Housing Lot Developments (택지개발에 따른 표면재료를 고려한 우수유출저감시설의 침투 특성에 관한 실험 연구)

  • Im, Janghyuk;Song, Jaiwoo;Park, Sungsik;Park, Hosang
    • Journal of the Korean GEO-environmental Society
    • /
    • v.8 no.5
    • /
    • pp.47-55
    • /
    • 2007
  • The increment of impermeable land area due to widespread land development caused the adverse impact on urban disaster prevention because it could decrease the peak rate of runoff as well as increase the runoff and peak flow during rainy period. To date, little research has been conducted on the infiltration characteristics and quantitative analysis because of their highly dependence on construction method, paving material, surface permeability, and field condition. Hence, this study was performed to investigate the infiltration characteristics of runoff-reducing facilities according to the type of paving material, which were examined using experimental apparatus with varying paving material and rainfall intensity, and thus to provide fundamental research data for runoff-reducing infiltration facilities. In this study, the infiltration characteristics were examined under the rainfall intensity of 20, 30, 50, 80, 100, 200 mm/hr for a variety type of paving materials such as concrete, asphalt, sand, grassland, and permeable paving material. The infiltration rate for permeable paving material was observed to be more than 93% under the condition of less than 200 mm/hr of rainfall intensity. For the compacted earth and grassland, the ultimate infiltration rate was estimated to be about 13% to 67%. The permeable paving material was concluded to be the most appropriate one for the runoff-reducing infiltration facilities because it has more favorable advantages than others in the light of infiltration volume, disaster prevention, and river training.

  • PDF

A 2D GPU-Accelerated High Resolution Numerical Scheme for Solving Diffusive Wave Equation (고해상도 수치기법을 이용한 GPU 기반 2D 확산파 모형)

  • Park, Seonryang;Kim, Dae-Hong
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2019.05a
    • /
    • pp.109-109
    • /
    • 2019
  • 본 연구에서는 강우-유출 과정 모의를 위한 GPU 기반 확산파 모형을 개발하였다. 확산파 방정식을 풀기위한 수치기법으로는 유한체적법을 이용하였으며, van Leer TVD limiter를 적용한 MUSCL 기법을 이용하여 각 셀의 인터페이스의 물리적 성질을 재구성하여 구하였다. 또한, 침투를 고려하기 위하여 Horton 침투 모형을 이용하였다. 개발된 모형을 이용하여 1D single overland plane과 2D V-shaped overland에서 강우-유출 과정을 모의실험을 하였으며, 각각 해석해와 dynamic wave model을 이용하여 계산된 수치 결과와 비교하여 본 모형의 정확성을 검증하였다. 또한, 1D와 2D의 기복이 심한 지형에 적용하여 강우-유출과정이 본 모형을 통하여 물리적으로 타당한 해석이 가능함을 검증하였다. 마지막으로 복잡한 실제 지형에 적용하였으며, 측정값과의 비교를 통하여 실제 유역에서의 확산파 모형의 적정성을 검증하였다. 또한, 본 연구에서는 NVIDIA사의 GPU인 Geforce GTX 1050과 GPU의 병렬 연산 처리 능력을 활용할 수 있는 NVIDIA사의 CUDA-Fortran을 이용하여 GPU 기반 확산파 모형을 개발하였다. PC windows에서 CPU(Intel i7, 4.70 GHz) 기반 모형 대비 GPU 기반 모형의 계산속도 성능을 비교한 결과, 격자 간격이 증가할수록 CPU 기반 모형 대비 GPU 기반 모형의 연산 효율이 증가하였으며, 격자 간격이 $3200{\times}3200$일 때, CPU 기반 모형 대비 GPU 기반 모형의 연산 효율이 최대 약 150배 증가하였다.

  • PDF

An Effective Stress Analysis of Unsaturated Slope Failures by Rainfall Infiltration (강우 침투로 인한 불포화 사면 붕괴의 유효응력 해석)

  • Lee, Young-Huy;Oh, Se-Boong;Jin, In-Chul;Kim, Jun-Woo;Park, Yeong-Mog
    • Journal of the Korean Geotechnical Society
    • /
    • v.29 no.12
    • /
    • pp.77-85
    • /
    • 2013
  • Unsaturated slopes experience infiltration during rainfall and become unstable when saturated. On the viewpoint of unsaturated effective stress, as matric suction decreases, both effective stress and shear strength decrease, which declines slope stability consequently. This study is focused on describing effective stress based on suction stress. The actual slope failures are simulated to calculate factors of safety in the field of finite element stress. In the residual soils of Hadong and Pohang, unsaturated properties are evaluated by laboratory tests. For unsaturated slopes, analyses of infiltration, stress and stability were performed to simulate actual failures. Based on unsaturated effective stress principle, the stability of actual slopes could be evaluated successfully. It is verified for the effective stress concept to be applicable to the engineering practice on slope design which considers infiltration by rainfall.

Applicability Estimation of LID Techniques (LID 요소기술의 적용성 평가)

  • Yeon, Jong Sang;Kim, Eung Seok;Shin, Hyun Suk;Jang, Young su
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.444-444
    • /
    • 2015
  • 현제 도시유역의 산업화와 도시화로 인해 유역 내 불투수면적의 증가는 직접 유출량 증가, 지하수자원 고갈, 침투량 감소, 증발산량의 감소 등의 물 순환 체계의 변화를 가져왔다. 이러한 도시 유역 내 물 순환 체계 변화를 개선하기 위해 여러 국가에서 저영향개발(Low Impact Development, LID)의 개발 및 도입이 진행되고 있다. LID는 분산형 빗물관리 시설로써 유역 내 소규모의 LID 요소기술을 대상유역에 적용하여 강우유출수를 저류, 체류, 방지 및 처리하는 시설을 의미한다. LID는 궁극적 목표로 계획단계에서 개발이전의 수문기능을 유지하기 위해 보전, 영향최소화, 유출이동시간 유지, 추가유출량 감소, 오염발지에 초점을 맞추어 계획된다. 현제 LID의 성능 및 적용성에 대한 다양한 연구가 진해되어지고 있으나, LID 요소기술별 시공 비용, 유지관리 비용, 강우유출수 저감효율, 비점오염원 저감효율, 적용위치 등의 다양한 인자를 복합적으로 고려하여 LID요소기술별 적용성 평가를 수행한 연구는 미미한 실정이다. 따라서 본 연구에서는 LID 요소기술 중 나무화분 여과장치, 옥상녹화, 빗무정원, 투수성포장, 침투트렌치, 빗물통, 식생수로 등의 총 7가지 LID 요소기술을 대상으로 연구를 수행하였다. LID 요소기술의 적용성평가를 수행하기 위해 시공비용, 유지관리비용, 강우유출수 저감효율, 비점오염원 저감효율, 적용위치 등의 촐 5가지 평가인자를 Entropy 방법을 이용하여 평가인자별 가중치를 산정하였다. 이후 다기준의사결정 방법 중 PROMETHEE 방법을 이용하여 LID 요소기술의 우선순위를 산정하였다. 현제 PROMETHEE 방법을 이용하여 LID 요소기술별 우선순위를 산정한 결과 옥상녹화가 첫번째 우선순위로 분석되었으며, 침투트렌치, 나무화분여과장치, 투수성포장, 식생수로, 빗물통, 빗물정원 순으로 분석되었다. 따라서 국내에 LID를 적용할 경우 옥상녹화, 침투트렌치, 나무화분 여과 장치 등의 LID 요소기술의 적용성 및 기대효과가 클 것으로 판단된다. 그러나 국내의 모든 지역을 대상으로 적용하기에는 문제가 있으며, 국내 LID 요소기술 적용 시 기초자료로 사용될 수 있을 것으로 판단된다. 대상지역별 신뢰도 높은 LID 요소기술 적용성 평가를 위해서는 대상유역 내 시공된 LID 요소기술을 계측하여 비점오염원 및 우수유출수 저감효율, 시공 비용, 연간 유지관리 비용을 분석하여 평가를 수행되어 한다고 판단된다.

  • PDF

Analysis of Reduction Efficiency of Storm water and Pollutant in Filter Type and Clearance Type Permeable Blocks (침투형 및 틈새형 투수블럭에서의 빗물유출 및 오염물질 저감효율 분석)

  • Gil, Kyungik;Lee, Dawon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.210-210
    • /
    • 2020
  • LID (Low Impact Development, 저영향개발)는 산업화 및 도시화 진행 지역에서 비점오염원으로부터 배출되는 오염물질을 제어해 개발지역 내 자연순화 기능을 최대한 유지하고, 물순환 기능증대를 통해 강우 유출수를 지역 내에서 관리하는 것을 목표로 한다. 비점오염원 저감 LID 시설에는 자연형과 장치형 시설이 있다. 자연형 시설에는 저류형, 침투, 식생형 시설 등이 있다. 특히, 침투시설에는 대표적으로 투수블럭이 있으며, 이는 투수성 포장재를 통해 강우 유출수를 지하로 침투시켜 여과나 흡착 등으로 비점오염물질을 제어하는 시설이다. 장치형 시설로는 여과재나 망을 이용해 비점오염물질을 분리하는 여과형 및 스크린형 시설, 응집과 침전을 통해 비점오염물질을 분리하는 응집·침전 시설 등이 있다. 이에 본 연구는 2016년부터 2018년 3년간 전주 서곡지구 지역 내 설치된 필터형 투수블럭, 틈새형 투수블럭에서 진행했다. 각각의 투수블럭에서 총 19회, 20회의 강우 모니터링을 실시했고, 오염물질 유입 및 유출 EMC 등의 분석을 통해 유출 및 오염물질 저감효과를 분석했다. 연구 대상 각 투수블럭의 주요 제원은 시설 용량 14.4㎥, 시설 면적은 14.4㎡이다. 모니터링 결과값을 분석한 결과 필터형 투수블럭의 경우 유출 저감율은 17.4 ~ 100%, 틈새형 투수블럭은 29.6 ~ 100%이었다. 필터형 투수블럭과 틈새형 투수블럭의 단위면적당 유량 저감량은 각각 0.014 ~ 0.583㎥/㎡, 0.035 ~ 0.588㎥/㎡이었다. 오염물질 저감효율을 분석한 결과 유기물 항목(BOD, TOC)의 경우 틈새형 투수블럭에서의 저감효율(BOD 93.59%, TOC 90.39%)이 필터형 투수블럭에서의 저감효율(BOD 89.99%, TOC 86.94%) 보다 다소 높게 나타났다. 영양염류 항목(T-N, T-P)의 경우 필터형, 틈새형 모두 비슷한 저감효율(필터형 T-N 89.02%, 필터형 T-P 98.12%, 틈새형 T-N 90.41%, 틈새형 T-P 98.04%)을 보였다.

  • PDF