Performance Comparison of Steel Dampers with or without Lateral Deformation Prevention Details and Strut Shapes (횡변형 방지 상세 유무 및 스트럿 형상에 따른 강재댐퍼의 성능 비교)

  • Lee, Hyun-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.5
    • /
    • pp.66-73
    • /
    • 2022
  • In this study, the experimental results of 7 dampers with the same strut height and similar cross-sectional area were compared based on the existing research results on steel dampers with rocking behavior. As steel plate dampers, SI-260, SV-260, SS-260 without Lateral deformation prevention detail(Ldpd), I-1, V-1, S-1 with Ldpd, and R20-260 with steel rod damper were evaluated. In addition, R15-260, which has a cross-sectional area of 0.56 times than other dampers, was also reviewed to appropriately evaluate the behavior of the steel rod damper. An important study result is the application superiority of the steel rod damper, which improved the unidirectional behavior of the steel plate dampers. This was proved in the moment-resistance capacity and displacement ratio evaluation. As a result of the evaluation, the R20-260, a steel bar damper, was evaluated as having the best performance. In addition, it is judged to have sufficient seismic resistance as it shows deformability up to a displacement ratio of 2.0.

Steel Rod Damper and Rocking Behavior (강봉 댐퍼와 록킹 거동)

  • Lee, Hyun-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.6
    • /
    • pp.1-9
    • /
    • 2020
  • In this study, a seismic reinforcement system was developed considering the rocking behavior of walls. The rocking behavior is to rotate left and right around the vertical axis of the wall, and the development system is a method of dissipating energy by installing a damper to a large displacement part. Developed steel rod damper was used, and steel rod diameter and length(aspect ratio) were selected as variables. As a result of the experiment, it was evaluated to have excellent seismic performance when the damper length was 260mm.

Displacement Dependency and Capacity Evaluation According to the Cross-Sectional Shape and Aspect Ratio of Steel Rod Dampers (강봉댐퍼의 단면형상과 형상비에 따른 변위의존성 및 성능 평가)

  • Hyun-Ho Lee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.5
    • /
    • pp.89-96
    • /
    • 2023
  • In this study, the displacement dependence, strength, and energy dissipation capacity of the steel rod damper were evaluated. The test variables were cross-sectional shape and aspect ratio. The 6th test specimens were made for performance test. From the test results, it was evaluated that the displacement dependence conditions of design code were satisfied in all specimens. And the strength effect according to the cross-sectional shape was minimal. As a result, the strength and energy dissipation capacity of the aspect ratio of 13.7 were evaluated as excellent.

Dependency and Performance Evaluation according to the Number of Steel Rod Dampers and the use of Z plates (강봉댐퍼의 개수 및 Z 플레이트 사용에 따른 의존성 및 성능 평가)

  • Lee, Hyun-Ho
    • Journal of Korean Association for Spatial Structures
    • /
    • v.23 no.4
    • /
    • pp.51-58
    • /
    • 2023
  • In this study, the displacement dependence, strength, and energy dissipation capacity of the steel rod damper were evaluated. The test variables are the number of steel rod dampers and the lateral deformation prevention details. From test results, it was evaluated that the displacement dependence conditions in the structural design code were satisfied. The maximum strength and energy dissipation capacity increased linearly as the number of steel rod increased. In addition, the maximum strength and energy dissipation capacity were evaluated by more than 20 times increased by using of the lateral deformation prevention details.

Performance Comparison of Steel Rod and Steel Plate Dampers with the Same Damper Height (댐퍼 높이가 같은 강봉 및 강판 댐퍼의 성능 비교)

  • Lee, Hyun-Ho
    • Journal of Korean Association for Spatial Structures
    • /
    • v.22 no.4
    • /
    • pp.49-57
    • /
    • 2022
  • In this study, based on the research results of the steel plate and steel rod dampers with rocking behavior, the moment and the drift ratio were compared and evaluated. As a test result evaluation, it was showed that the behavior of R15-200 and R15-140 was very good than other dampers. And the steel rod damper showed in-plane behavior to the loading direction, and was evaluated to prevent out-of-plane behavior that causes performance degradation.

Seismic Performance of an Existing Low-Rise Reinforced Concrete Piloti Building Retrofitted by Steel Rod Damper (강봉댐퍼로 보강한 기존 저층 철근콘크리트 필로티 건물의 내진성능)

  • Baek, Eun Lim;Oh, Sang Hoon;Lee, Sang Ho
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.18 no.5
    • /
    • pp.241-251
    • /
    • 2014
  • In this study, shaking table test was carried out to evaluate the seismic behavior and performance of low-rise reinforced concrete (RC) piloti structures with and without retrofit. The specimens were designed considering the characteristics of existing building with pilotis such as natural period, distribution factor of strength and stiffness between columns and core wall on the first soft story. The test for the non-retrofit specimen showed that damage was concentrated on the stiffer member on the same floor as the core wall failed by shear fracture whereas columns experienced slight flexural cracks. Considering the failure mode of the non-retrofit specimen, the retrofit method using steel rod damper was presented for improving the seismic performance of piloti structures. The results of the test for retrofit specimen revealed that the retrofit method was effective for controlling the damage as the main RC structural members were not destroyed and most of input energy was dissipated by hysteretic behavior of the damper.