• Title/Summary/Keyword: 강도감소 모델

Search Result 363, Processing Time 0.02 seconds

The Comparative Imaging Study on Mn-phthalocyanine and Mangafodipir trisodium in Experimental VX2 Animal Model (실험적으로 유발시킨 VX2 동물모델에서의 Mn-phthalocyanine과 Mangafodipir trisodium의 비교영상)

  • Park Hyun-Jeong;Ko Sung-Min;Kim Yong-Sun;Chang Yongmin
    • Investigative Magnetic Resonance Imaging
    • /
    • v.8 no.1
    • /
    • pp.32-41
    • /
    • 2004
  • Purpose : To measure the NMR relaxation properties of MnPC, to observe the characteristics of liver enhancement patterns on MR images in experimentally implanted rabbit VX2 tumor model, and to estimate the possibility of tissue specific contrast agent for MnPC in comparison with the hepatobiliary agent. Materials and Methods : Phthalocyanine (PC) was chelated with paramagnetic ions, manganese (Mn). 2.01 g (5.2 mmol) of phthalocyanine was mixed with 0.37 g (1.4 nlmol) of Mn chloride at $310^{\circ}C$ for 36 hours and then purified by chromatography ($CHCl_3:\;CH_3OH=98:2$, volume ratio) to obtain 1.04 g $(46\%)$ of MnPC (molecular weight = 2000 daltons). The T1/T2 relaxivity (R1/R2) for MnPC were determined at a 1.5 T (64 MHz) MR spectrometer. VX2 tumor model was experimentally implanted in the liver parenchyma of rabbits. All MR studies were performed on 1.5 T. The human extremity radio frequency coil of a bird cage type was employed. MR images were acquired at 17 to 24 days after VX2 carcinoma implantation.4 mmol/kg MnPC and 0.01 mmol/kg Mn-DPDP were injected via the ear vein of rabbits. T1-weighted images were obtained with spin-echo (TR/TE=516/14 msec) and fast multiplanar spoiled gradient recalled (TR/TE : 80/4 msec, $60^{\circ}$ flip angle) pulse sequence. Fast spin-echo (TR/TE=1200/85 msec) was used to obtain the T2-weighted images. Results : The value of T1/T2 relaxivity (R1/R2) of MnPC was $7.28\;mM^{-1}S^{-1}$ and $55.56\;mM^{-1}S^{-1}$ respectively at 1.5 T (64 MHz). Because the T2 relaxivity of MnPC that bonded strongly, covalently manganese with phthalocyanine was very high, the signal intensity of liver parenchyma was decreased on postcontrast T2-weighted images and we could easily distinguish the VX2 carcinoma within the liver parenchyma. When MnPC was administrated intravenously, the tumor margin delineation was more remarkable than Mn-DPDP-enhanced images. The enhancement of liver parenchyma with MnPC persisted at relatively high levels over at least one hour after injection of the contrast agents. Conclusion : The hepatic uptake and biliary excretion of MnPC, which are similar to Mn-DPDP, suggest that this agent is a new liver-specific agent. Also, MnPC seems to be used as a dual contrast agent (T1 and T2) with high T2 relaxivity. However, it is warranted that MnPC needs further investigation as a potential contrast agent for MR imaging of the liver. That is, further characterizations of MnPC are needed in vivo and in vitro before clinical trials. The diagnostic potential of MnPC will also have to be examined more in the animal models of additional types.

  • PDF

Anti-climacterium Effects of Gagamguibiondam-tang in Ovariectomized Rats (난소적출로 유발된 랫트 갱년기 장애에 대한 가감귀비온담탕의 생리활성 효과 평가)

  • Han, Sang-Gyeom;Kim, Dong-Chul
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.30 no.4
    • /
    • pp.18-44
    • /
    • 2017
  • Purpose: The object of this study was to observe the anti-climacterium activity of Gagamguibiondam-tang (GGOT) on ovariectomized (OVX) rats, a well-documented rodent models resembles with women postmenopausal climacterium symptoms, as including cardiovascular diseases, obesity, hyperlipidemia, osteoporosis, organ steatosis and mental disorders. Methods: In this study, anti-climacteric effects were evaluated separated into three categories; 1) anti-obese, 2) anti-uterine atrophy and 3) anti-osteoporotic effects. Five groups were used (8 rats in each group); sham control, OVX control, GGOT 500, 250 and 125 mg/kg administered groups. Twenty-eight days after bilateral OVX surgery, GGOT were orally administered, once a day for 84 days, and then the changes on the body weight and gain during experimental periods, serum estradiol levels, abdominal fat pad and uterus weights with histopathology of abdominal fat pads (total thickness and mean adipocyte diameters) and uterus (total, epithelial and mucosal thickness, percentages of uterine gland regions) for anti-obese and estrogenic effects. In addition, femur, tibia and fourth or fifth lumbar vertebrae (L4 or L5) wet, dry and ash weights, mineral density (BMD), bone strength (failure load), serum osteocalcin and bone specific alkaline phosphatase (bALP) contents, histological and histomorphometrical analyses - bone mass and structure with bone resorption, were monitored for anti-osteoporosis activity. Results: As a result of OVX, noticeable increases of body weight and gains, food and water consumption, weights of abdominal fat pad deposited in dorsal abdominal cavity, serum osteocalcin levels were demonstrated in this experiment with decrease of uterus, femur, tibia and L5 weights, serum bALP and estradiol levels. In addition, marked hypertrophic changes of adipocytes located in deposited abdominal fat pads, uterine disused atrophic changes, decreases of bone mass and structures of femur, tibia and L4 were also observed in OVX control rats with dramatic increases of bone resorption markers, the Ocn and OS/BS at histopathological and histomorphometrical analysis in this study as compared with sham-operated control rats, suggesting the estrogen-deficient climacterium symptoms - obese and osteoporosis were induced by OVX, respectively. However, these estrogen-deficient climacterium symptoms induced by bilateral OVX in rats were significantly inhibited by 84 days of continuous oral treatment of GGOT 500, 250 and 125 mg/kg, respectively. Especially, GGOT 500, 250 and 125 mg/kg showed clear dose-dependent inhibitory activities on the OVX-induced climacterium signs. Conclusion: The results suggest that oral administration of GGOT 500, 250 and 125 mg/kg has clear dose-dependent favorable anti-climacterium effects - estrogenic, anti-obese and anti-osteoporotic activities in OVX rats in this experiment.

[ $^1H$ ] MR Spectroscopy of the Normal Human Brains: Comparison between Signa and Echospeed 1.5 T System (정상 뇌의 수소 자기공명분광 소견: 1.5 T Signa와 Echospeed 자기공명영상기기에서의 비교)

  • Kang Young Hye;Lee Yoon Mi;Park Sun Won;Suh Chang Hae;Lim Myung Kwan
    • Investigative Magnetic Resonance Imaging
    • /
    • v.8 no.2
    • /
    • pp.79-85
    • /
    • 2004
  • Purpose : To evaluate the usefulness and reproducibility of $^1H$ MRS in different 1.5 T MR machines with different coils to compare the SNR, scan time and the spectral patterns in different brain regions in normal volunteers. Materials and Methods : Localized $^1H$ MR spectroscopy ($^1H$ MRS) was performed in a total of 10 normal volunteers (age; 20-45 years) with spectral parameters adjusted by the autoprescan routine (PROBE package). In all volunteers, MRS was performed in a three times using conventional MRS (Signa Horizon) with 1 channel coil and upgraded MRS (Echospeed plus with EXCITE) with both 1 channel and 8 channel coil. Using these three different machines and coils, SNRs of the spectra in both phantom and volunteers and (pre)scan time of MRS were compared. Two regions of the human brain (basal ganglia and deep white matter) were examined and relative metabolite ratios (NAA/Cr, Cho/Cr, and mI/Cr ratios) were measured in all volunteers. For all spectra, a STEAM localization sequence with three-pulse CHESS $H_2O$ suppression was used, with the following acquisition parameters: TR=3.0/2.0 sec, TE=30 msec, TM=13.7 msec, SW=2500 Hz, SI=2048 pts, AVG : 64/128, and NEX=2/8 (Signa/Echospeed). Results : The SNR was about over $30\%$ higher in Echospeed machine and time for prescan and scan was almost same in different machines and coils. Reliable spectra were obtained on both MRS systems and there were no significant differences in spectral patterns and relative metabolite ratios in two brain regions (p>0.05). Conclusion : Both conventional and new MRI systems are highly reliable and reproducible for $^1H$ MR spectroscopic examinations in human brains and there are no significant differences in applications for $^1H$ MRS between two different MRI systems.

  • PDF