• 제목/요약/키워드: 강골조

검색결과 27건 처리시간 0.023초

내진설계 강골조 구조물의 감쇠기 위치 최적화 (Optimum of Damper Position for Steel Frame Structure on Seismic Design)

  • 박순응;박문호;김진규
    • 한국산업융합학회 논문집
    • /
    • 제12권4호
    • /
    • pp.187-192
    • /
    • 2009
  • This study is performing a seismic analysis on the steel frames structure with dampers and analyzing the dynamic behavior in order to examine their efficiency and study the optimum dampers position to the seismic design steel structure. To improve the ability against an earthquake, this study performed the time history analysis. Controling an earthquake is the way to minimize the damage of the steel structure by dissipating input energy generated by an earthquake.

  • PDF

P.E.B 시스템 강골조에서 H형강 기둥 - Rafter 접합부의 구조성능 (Structural Performance of H-shaped Column-Rafter Connection in the P.E.B Systematic Steel Frames)

  • 김종성
    • 한국강구조학회 논문집
    • /
    • 제17권3호통권76호
    • /
    • pp.347-356
    • /
    • 2005
  • 최근 들어 강구조 공장건축은 상당부분 P.E.B.시스템으로 지어지고 있으나 관련기술이 대부분 외국에서 수입된 것으로 전용프로그램(예, MBS, LTI 등)에만 의존하고 있고 국내의 설계지침이 없어서 AISC-ASD에 의해 설계하고 있다. 또한 P.E.B.골조의 구조적 거동을 검토한 연구 및 H형강을 이용한 요소기술 개발이 부족한 실정에 있다 특히, 기둥-보(rafter) 접합부는 Extended type end plate에 의한 접합에만 의존하여 과다설계의 경향이 있으므로. 접합부에 대한 구조적 검토가 필요하다. 따라서 이 연구에서는 P.E.B.시스템 공장건물에서 H형강-보(rafter)의 접합부(Extended/Flush type)의 구조성능을 실험적으로 평가하여 구조적, 경제적으로 우수한 P.E.B. 시스템 골조의 설계를 위한 기초자료를 제공하고자 한다.

무보강 상·하부 ㄱ형강 접합부의 소성휨모멘트 저항능력 예측을 위한 실험 및 해석적 연구 (Experimental Tests and Analytical Study for the Prediction of the Plastic Moment Capacity of an Unstiffened Top and Seat Angle Connection)

  • 양재근;최정환;김현광;박재호
    • 한국강구조학회 논문집
    • /
    • 제23권5호
    • /
    • pp.547-555
    • /
    • 2011
  • 무보강 상 하부 ㄱ형강 접합부는 중 저층 강골조의 시공에 적합한 부분강접 접합부의 한 형태이다. 무보강 상 하부 ㄱ형강 접합부의 초기회전강성뿐만 아니라 소성휨모멘트 지지능력은 실제 설계 및 시공에 있어서 매우 중요한 인자로 이에 대한 예측이 반드시 필요하다. 따라서 그동안 진행된 무보강 상 하부 ㄱ형강 접합부에 대한 연구는 초기회전강성 및 소성휨모멘트 지지능력에 영향을 미치는 접합부의 기하학적 형상을 변화시키면서 거동양상을 파악하였다. 이 연구에서는 AISC LRFD Spec.에서 정의한 Type A 형태 접합부의 상부 ㄱ형강의 두께 및 고력볼트 게이지 거리를 변수로 하여 접합부 실험을 수행하여 휨모멘트 지지능력을 파악하였고, 이를 바탕으로 소성휨모멘트 지지능력 예측을 위한 해석모델을 제안하고자 진행하였다. 해석모델 적용의 타당성은 타 연구자가 수행한 접합부 실험결과와 비교 검토함으로써 입증하였다.

패널존과 점성감쇠기를 고려한 강골조 구조물의 내진 설계 모델 (Seismic Design of Steel Frame Model Considering the Panel Zone and Viscous Dampers)

  • 박순응;이택우
    • 한국공간구조학회논문집
    • /
    • 제20권2호
    • /
    • pp.87-94
    • /
    • 2020
  • The present study is aimed to calculate the optimal damping according to the seismic load on the structure with a non-seismic design to perform structure analysis considering the deformation of structural joint connection and panel zone; to develop design program equipped with structural stability of the steel frame structures reinforced with the panel zone and viscous dampers, using the results of the analysis, in order to systematically integrate the seismic reinforcement of the non-seismic structures and the analysis and design of steel frame structures. The study results are as follows: When considering the deformation of the panel zone, the deformation has been reduced up to thickness of the panel double plate below twice the flange thickness, which indicates the effect of the double plate thickness on the panel zone, but the deformation showed uniform convergence when the ration is more than twice. The SMRPF system that was applied to this study determines the damping force and displacement by considering the panel zone to the joint connection and calculating the shear each floor for the seismic load at the same time. The result indicates that the competence of the damper is predictable that can secure seismic performance for the structures with non-seismic design without changing the cross-section of the members.

시간이력감쇠기를 가진 강골조의 지진저항성능 (Earthquake resistant performance of steel frame with hysteretic damper)

  • 장준호;권민호
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제7권3호
    • /
    • pp.193-203
    • /
    • 2003
  • 이 논문은 이력감쇠기, 즉 unbonded brace를 이용한 폐브레이싱된 골조의 거동을 지배하는 구조적 특성을 연구하였으며, 이를 이용한 골조의 설계지침 개선을 제시코자 하였다. 본 연구에서는 시간이력댐퍼를 이용한 6층 폐브레이싱된 골조의 지진거동을 예시로 제시하였다. 또한 좌굴방지 브레이싱의 기계적 특징과 장점에 대해 간략히 서술하였다. 골조의 형상과 특성의 중요 파라메타의 효과를 살펴보기 위해 비선형동적해석을 수행, 비교 분석하였다.

2차 탄성해석법에 의한 강뼈대 구조물의 최적설계 (An Optimum Design of Steel Frames by Second Order Elastic Analysis)

  • 박문호;장준호;김기욱
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제10권2호
    • /
    • pp.123-133
    • /
    • 2006
  • 본 연구의 목적은 다단계 동적계획법 및 축차무제약 최소화기법을 이용하여 강접 및 다양한 반강접 접합부 모델을 가진 뼈대 구조물의 최적화 알고리즘을 개발하는데 있다. Bowing effect를 고려한 비선형 보-기둥이론을 사용하였으며, 보-기둥의 접합부는 반강접접합부인 양면 복부앵글을 가진 접합부, 상 하플랜지 접합부, 양면복부앵글을 가진 상 하플랜지 접합부를 고려하여 연구를 수행하였으며, 각 접합부의 해석모델은 수정된 지수모델, 다항식 모델, 파워모델을 사용하였다. 최적화문제에 있어서 목적함수는 강재의 중량을 취하였으며, 설계변수는 부재의 단면치수를 선택하였다. 설계제약조건은 축력, 전단력 및 휨모멘트의 저항성과 사용성에 대해 수식화하였다. 본 연구에서 개발된 기하학적 비선형을 고려한 2차 탄성해석법을 이용하여 강접 및 다양한 모델을 가진 반강접 강뼈대 구조물의 종합적인 연속 최적설계 프로그램을 개발하였다.

벽식마찰감쇄기의 개발 및 R/C 골조구조물에의 해석적 적용 (Development of Frictional Wall Damper and Its Analytical Applications in R/C frame Structures)

  • 조창근;박문호;권민호;강구수;서상길
    • 콘크리트학회논문집
    • /
    • 제14권5호
    • /
    • pp.718-725
    • /
    • 2002
  • 본 연구에서는 R/C 골조구조물에 대한 내진성능개선 방법으로서, 벽식 마찰 감쇄기 모델을 새롭게 제안하였다. 기존의 감쇄 장치가 일반적으로 브레이스 부재 형태를 취하고 있으나, 브레이스형 감쇄장치는 시공상 강골조구조물에는 적용하기 용이한 반면 R/C 골조구조물에 적용 시에는 R/C 구조부재와 감쇄기간의 연결 문제, 감쇄기와 R/C 부재 연결부에서의 응력집중으로 인한 R/C 구조부재의 파손 우려 등의 단점이 있다. 제안된 감쇄기는 감쇄기 연결부의 R/C 구조부재 파손 및 구조물의 P-Δ효과를 줄이는데 장점을 가지면서 감쇄기로서의 역할을 발휘하도록 한 테프론 슬라이더와 R/C 전단벽 조합형 감쇄기이다. 제안된 감쇄기의 내진성능개선 능력을 평가하기 위하여, 감쇄기의 수치모델을 고려한 R/C 골조구조물의 비선형 동적해석 알고리즘을 제시하였다. 지진하중이 작용하는 기존의 10층 3경간 R/C 골조구조물에 본 감쇄기를 적용한 수치해석 결과, 시간이력거동 및 층간변위의 억제에서 탁월한 제어효과를 나타내었으며, 저층 기둥 부재의 소성힌지 발생 및 구조부재의 손상을 감쇄기의 소산에너지로 억제하여 줌으로서 구조물 내진성능개선에 효과가 우수한 것으로 평가되었다.