• 제목/요약/키워드: 감쇠 지도

Search Result 510, Processing Time 0.168 seconds

Response Characteristics of Forced Vibration of High Damping Vehicle Passing the Bumped Barrier (둔턱을 진행하는 고감쇠 차량의 강제진동 응답특성)

  • Kim, Jong-Do;Yoon, Moon-Chul
    • Journal of Convergence for Information Technology
    • /
    • v.11 no.3
    • /
    • pp.132-139
    • /
    • 2021
  • The response characteristics of the forced vibration generated when the high-damped vehicle pass the bumped barrier was studied, and in particular, the response behavior of displacement, velocity and acceleration was analyzed for the forced vibration model. In addition, in order to obtain responses such as displacement, velocity, and acceleration, a numerical analysis technique of the Runge-Kutta-Gill method was performed in time domain. The response was successfully obtained in detail under several high damping conditions. As a numerical analysis result, the response of the vehicle was obtained by considering the vehicle body to which the impulse impact was applied. Also, the analysis result was compared with the experimental result in order to verify the validity of vehicle model. The amplitude and natural frequency of the vehicle were considered and analyzed. The Nyquist diagram of the vehicle model was also obtained and the relationship could be analyzed. And the vibration response was analyzed on different mass, damping and stiffness.

Nonlinear Noise Attenuator by Adaptive Wiener Filter with Neural Network (신경망 구조의 적응 Wiener 필터를 이용한 비선형 잡음감쇠기)

  • Haeng-Woo Lee
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.18 no.1
    • /
    • pp.71-76
    • /
    • 2023
  • This paper studied a method of attenuating nonlinear noise using a Wiener filter of a neural network structure in an acoustic noise attenuator. This system improves nonlinear noise attenuation performance with a deep learning algorithm using a neural network Wiener filter instead of using a conventional adaptive filter. A voice is estimated from a single input voice signal containing nonlinear noise using a 128-neuron, 8-neuron hidden layer and an error back propagation algorithm. In this study, a simulation program using the Keras library was written and a simulation was performed to verify the attenuation performance for nonlinear noise. As a result of the simulation, it can be seen that the noise attenuation performance of this system is significantly improved when the FNN filter is used instead of the Wiener filter even when nonlinear noise is included. This is because the complex structure of the FNN filter expresses any type of nonlinear characteristics well.

The Effect of Attenuation Correction with CT on the Interpretation of Myocardial Perfusion SPECT: in Patients with Normal Coronary Angiogram (관상동맥조영술상 정상소견을 보인 환자에서 전산화단층촬영술(CT)를 이용한 감쇠보정이 심근관류 SPECT의 판독에 미치는 영향)

  • Chun, Kyung-Ah;Cho, Ihn-Ho;Won, Kyu-Chang;Lee, Hyung-Woo;Hong, Geu-Ru;Shin, Dong-Gu;Kim, Young-Jo;Shim, Bong-Sup
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.4
    • /
    • pp.246-251
    • /
    • 2005
  • Purpose: There has been many reports for the effect of attenuation correction on myocardial perfusion SPECT. We studied the effect of attenuation correction with CT (computed tomography) in patients with normal coronary angiography. Materials and Methods: Fifteen patients with normal coronary artery on angiography and low likelihood of coronary artery disease were enrolled in this study (male: 6, female: 9, mean age: $58{\pm}8$ year). Myocardial perfusion SPECT was done with Millennium VG with Hawkeye device (GE, SPECT/CT camera). A visual analysis and polar map quantification (Emory tool box) was performed. In quantitative analysis, percent uptake of each myocardial wall on polar map (percent of maximal uptake) was compared between non-corrected (NC) and corrected (AC) images. Results: Visual analysis showed AC images led to an increase of uptake in the inferior wall, but decrease of uptake in the anterior wall, apex and septum. liver activity is also increased in AC images. In quantitative analysis, the percent uptake is decreased in the anterior wall, apex and septum, but increased in the inferior wall. It is helpful to interpret the images in the inferior wall after AC, but difficult in the apex and anterior wall after AC. Conclusion: AC is helpful in the inferior wall. But in the apex or anterior wall, AC must be carefully applied to normal perfused myocardium.

The Evaluation for Attenuation Map using Low Dose in PET/CT System (PET/CT 시스템에서 감쇠지도를 만들기 위한 저선량 CT 평가)

  • Nam, So-Ra;Cho, Hyo-Min;Jung, Ji-Young;Lee, Chang-Lae;Lim, Han-Sang;Park, Hoon-Hee;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.18 no.3
    • /
    • pp.134-138
    • /
    • 2007
  • The current PET/CT system with high quality CT images not only increases diagnostic value by providing anatomic localization, but also shortens the acquisition time for attenuation correction than primary PET system. All commercially available PET/CT system uses the CT scan for attenuation correction instead of the transmission scan using radioactive source such as $^{137}Cs,\;^{68}Ge$. However the CT scan may substantially increase the patient dose. The purpose of this study was to evaluate quality of PET images reconstructed by CT attenuation map using various tube currents. in this study, images were acquired for 3D Hoffman brain phantom and cylindrical phantom using GE DSTe PET/CT system. The emission data were acquired for 10 min using phantoms after injecting 44.03 MBq of $^{18}F-FDG$. The CT images for attenuation map were acquired by changing tube current from 10 mA to 95 mA with fixed exposure time of 8 sec and fixed tube voltage of 140 kVp. The PET images were reconstructed using these CT attenuation maps. Image quality of CT images was evaluated by measuring SD (standard deviation) of cylindrical phantom which was filled with water and $^{18}F-FDG$ solution. The PET images were evaluated by measuring the activity ratio between gray matter and white matter in Hoffman phantom images. SDs of CT images decrease by increasing tube current. When PET images were reconstructed using CT attenuation maps with various tube currents, the activity ratios between gray matter and white matter of PET images were almost same. These results indicated that the quality of the PET images using low dose CT data were comparable to the PET images using general dose CT data. Therefore, the use of low dose CT is recommended than the use of general dose CT, when the diagnostic high quality CT is not required. Further studies may need to be performed for other system, since this study is limited to the GE DSTe system used in this study.

  • PDF

Prediction Model of Rain Attenuation for Ka-Band Satellite Communication (Ka-대역 위성 통신의 위한 강우에 의한 전파 감쇠 예측 모델)

  • 우병훈;강희조
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.6 no.7
    • /
    • pp.1038-1043
    • /
    • 2002
  • The demand for multimedia service using Ka-band satellite communication are growing rapi이y. So, in this paper, we have analyzed rain attenuation with typical model, and proposed prediction model of rain attenuation in high frequency(over 20[GHz]). Path loss model by rain attenuation is based upon rain rate of representative region(6 cities). Proposed prediction model of rain attenuation and parameter of satellite link can be available for the Ka-band satellite communication.

Development of Air Spring Damper System(ASDS) (공기 스프링 댐퍼 시스템(ASDS)의 개발)

  • Kim, Dong Baek;Park, Heung Sik
    • Journal of the Society of Disaster Information
    • /
    • v.17 no.4
    • /
    • pp.829-838
    • /
    • 2021
  • Purpose: The Air Spring Damper System (ASDS) is proposed when existing concrete structures that have not been seismic resistant for economic and technical reasons or low-rise concrete structures that are difficult to earthquake. Method: To conduct a study on the damping force antigen in the kinetic equation of free vibration, we analyze whether this device has damping ability as a damper experimentally and theoretically, and examine the possibility of field application. Result: The air damper system is considered to be more economical than steel hysteresis dampers even if the number of dampers increases due to its easy manufacture and construction and low restrictions on shape, size, material, etc. Conclusion: In an air spring damper system, it is essential to reduce the diameter of the air inlet/outlet hole to improve the damping ratio, and in this case, if the diameter exceeds a certain lower limit, consideration of the compressibility of air is required, so further research is needed.

Design and Fabrication of K-band Attenuation Standard (K-대역 감소량 표준기의 설계 및 제작)

  • Lee Joo-Gwang;Kim Jeong-Hwan;Kang Jin-Seob;Kang Tae-Weon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.4 s.107
    • /
    • pp.387-392
    • /
    • 2006
  • In this paper, measurement scheme and uncertainty estimation of the K-band attenuation standard fitted with 3.5 mm coaxial connectors are described. The standard comprises a build-up chain of four steps of power ratio mea-surement and operates in the frequency range of 18 GHz to 26.5 GHz. The nominal attenuation of each step is around 20 dB and total dynamic range is 80 dB. The expanded uncertainty of the overall system is 0.01 dB at the confidence level of approximately 95%.

A Signal Anti-reduction System in PLC using Ferrite Core and Switching Amplifier (페라이트 코어와 스위칭 증폭기를 이용한 PLC 신호 감쇠 저하 시스템)

  • 고종선;김영일;김규겸
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.6 no.6
    • /
    • pp.474-480
    • /
    • 2001
  • In this paper a low signal reduction communication system that does not use the communication line but power line is presented It will be very useful for an information-oriented society with tele-metering and home automation. The conventional system has a difficulty in transmitting information due to decreasing communication voltage. The proposed system employs a special type switching amplifier system which has a low inner resistance and uses high efficient ferrite core in coupling circuit. This new system is proposed to reduce the loss of conductor load and coupling circuit in a PLC system.

  • PDF

The Optimum Design of Adaptive Channel Coding for Rain-Attenuation Compensation in Satellite Communication Systems (위성통신시스템에서 강우감쇠 보상을 위한 적응형 부호화 기법 최적 설계)

  • 김상명;최은아;장대익;정지원;오덕길
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.26 no.5B
    • /
    • pp.572-581
    • /
    • 2001
  • 본 논문에서는 위성통신에서 강우감쇠에 따라 가변 부호화율을 적용시킬 수 있는 적응형 부호화 기법에 대한 연구를 하였다. 따라서, 3bit 연판정을 적용한 Viterbi 복호기를 이용하여 QPSK와 TC-8PSK 신호를 복호할 수 있는 pragmatic TCM과 LSB 부호화 알고리즘에 대해 여러 부호화율에서 성능분석을 하였다. 또한 구현을 위한 최적의 파라미터를 설정하여 부호화율 2/3를 가지는 pragmatic TCM을 VHDL 모델링 하였다. 구현결과 PLEX10KE100EQC208-1 CPLD 칩으로 구현 가능하였으며, 42.36 Mbps의 복호 속도를 가진다. 실제 ASIC 설계시 CPLD 속도보다 약 5∼6배의 고속화가 가능하므로, 200 MHz 트렌스 폰더를 갖는 Ka 대역 초고속 위성통신 시스템에서 강우 감쇠에 대처하기 위한 적응형 트렐리스 부호화방식에 적용할 수 있다.

  • PDF

A Novel Dielectric Resonator Bandpass Filter with Variable Attenuation Poles for Duplexer Applications (가변 감쇠극을 갖는 새로운 구조의 유전체 공진기 대역통과 여파기의 설계)

  • 조상호;성영제;김영식
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.13 no.1
    • /
    • pp.12-18
    • /
    • 2002
  • In this paper a novel dielectric resonator (DR) bandpass filter (BPF) with flexible arrangement of attenuation poles is proposed. This DR filter is similar to a conventional DR filter except adding a microstrip line below a DR, which not only shifts the location of attenuation poles, but also improves skirt characteristics. The duplexer with the proposed DR BPF has been yielded better isolation and sharper skirt behavior than that with a conventional DR filter. The implemented duplexer has shown a good performance and been well agreed with the simulation.