Dynamic Modeling of Semi-active Squeeze Mode MR Damper for Structural Vibration Control (구조물의 진동 제어를 위한 압착식 MR 감쇠기의 동적 모델링)

  • Heo, Gwang-Hee;Jeon, Joon-Ryong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.13 no.2 s.54
    • /
    • pp.172-180
    • /
    • 2009
  • Normally in order to build a semi-active control system equipped with MR damper, the dynamic modeling of the damper is required to numerically predict its dynamic damping force and also its behavioral characteristics. For the dynamic modeling of the MR damper, this paper attempts to predict and evaluate its dynamic behavior by applying specifically both a power model and a Bingham model. Dynamic loading tests were performed on the squeeze type of damper specially designed for this research, and force-displacement hysteresis loops confirmed the effectiveness of the damper as a semi-active control device. In the meantime, in order to evaluate the effectiveness of each model applied, the model parameter for each model was identified. On the basis of the parameter, we derived the error ratio of the force-velocity relationship curve and the dynamic damping force, which was contrasted and compared with the experimental results of the squeeze type of damper. Finally, the squeeze type of MR damper developed in this research was proved to be valid as a semi-active control device, and also the evaluation of the two dynamic models showed they were working fine so that they were likely to be easily utilized to numerically predict the dynamic characteristics of any dampers with MR fluid as well as the squeeze type of MR damper.

A Study on the Applicability of Hybrid Mass Damper for the Vibration Control of the Structure under Base Excitation (지반 기진력을 받는 구조물의 진도제어를 위한 Hybrid Mass Damper의 유용성에 관한 연구)

  • 문석준;임채욱;정태영;한성용
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.5 no.4
    • /
    • pp.1-8
    • /
    • 2001
  • In this paper, a hybrid mass damper using AC-servomotor was designed and developed in order to reduce vibration levels of a 5-story test structure under base excitation. Control performances of the HMD under random and earthquakes excitations are compared with those of TMD through experimental test. It is confirmed that the HMD is more effective to reduce the vibration levels of the test structure especially for the earthquake excitation which excites more than 2 vibration modes of the structure simultaneously.

  • PDF

An Experimental Study on Effect of Half-Wave Resonator Position on Acoustic Damping in a Combustion Chamber (연소실내 공명기 장착 위치에 따른 음향갑쇠 효과에 관한 실험적 연구)

  • Sohn, Chae-Hoon;Kim, Chul-Hee
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.12 no.2
    • /
    • pp.1-7
    • /
    • 2008
  • Effect of radial position of half-wave resonator is investigated experimentally for acoustic damping in a combustion chamber by adopting acoustic cold test. Acoustic damping is quantified by damping factor. When resonator with optimal tuning length is installed, damping is enhanced as its radial location is away from the center of the faceplate. And, spatial profile of damping factor is similar to that of the amplitude of the acoustic mode to be damped. As the location is close to the center, acoustic damping is mitigated and independent of the resonator length. On the other hand, the resonator with non-optimal length dose not show any effects of its radial position. Acoustic-damping capacity can be evaluated as functions of resonator length and position.

Calculation of Optimum Damping Ratio of Viscous Dampers Using Capacity Spectrum Method (능력스펙트럼법을 이용한 점성 감쇠기의 적정 감쇠비 산정)

  • 김진구;최현훈
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.5 no.1
    • /
    • pp.45-52
    • /
    • 2001
  • 에너지 소산장치가 설치된 건무의 비선형 시간이력해석은 복잡하고 많은 시간이 소모된다. 본 연구에서는 비선형 정적해석법인 능력 스펙트럼을 이용하여 구조물의 주어긴 거동 한계를 만족할 수 있는 감쇠기의 양을 산정하는 방법에 관하여 연구하였다. 먼저 능력스펙트럼법을 이용하여 건물의 비선형 정적응답을 구하고 건물의 응답과 목표변위의 차이를 이용하여 유효감쇠비를 구하고 이러한 유효 감쇠비를 이용하여 필용한 점성 감쇠기의 양을 구하였다. 본 연구에서는 단자 유도계에서 건물의 주기, 요구되는 탄성강도에 대한 항복강도의 비, 항복 후 강성비 등을 변수로 하여 연구를 수행하였다. 제안된 방법에 따라 설계된 점성 감쇠기를 설치한 예제 구조물의 시간이력 해석에 의한 최대 응답은 설계의 초기단계에서 사용한 목표변위와 잘 일치하였다.

  • PDF

Control Effectiveness of Shear Walls Connected by Beams with Friction Dampers (인방보에 마찰형 감쇠기가 설치된 전단벽의 제진효과)

  • Chung, Hee-San;Min, Kyung-Won
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.22 no.1
    • /
    • pp.105-115
    • /
    • 2009
  • Numerical analysis of shear walls governed by flexural behavior is conducted for the seismic control performance of proposed friction dampers installed at the center of coupling beams. Control effectiveness of shear walls connected by beams with the proposed dampers are compared for single shear wall with same flexural rigidity. Average responses of the shear walls with the dampers are found with seven scaled-downed earthquakes based on KEC 2005 design spectrum. Slip load is the most important design parameter. It is designed to be 5, 10, 20, 30, 60, 90% of total vertical shear force at damper location to prevent damper slip in specific stories. Nonlinear time-history analysis is conducted by using SeismoStruct analysis program. Seismic control performance of the dampers is evaluated for base shear, energy dissipation, curvature and top-floor displacement. Results show that the dampers are the most effective in reducing the responses when their total slip load is 30% of total vertical shear force.

Preliminary Design Procedure of MR Dampers for Controlling Seismic Response of Building Structures (건축구조물의 지진응답제어를 위한 MR 감쇠기 예비설계절차)

  • Lee, Sang-Hyun;Min, Kyung-Won;Lee, Roo-Jee;Kim, Joong-Koo
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.8 no.5 s.39
    • /
    • pp.55-64
    • /
    • 2004
  • In this paper, the preliminary design procedure of magnetorheological (MR) dampers is developed for controlling the building response induced by seismic excitation. The dynamic characteristics and control effects of the modeling methods of MR dampers such as Bingham, biviscous, hysteretic biviscous, simple Bouc?Wen, Bouc?Wen with mass element, and phenomenological models are investigated. Of these models, hysteretic biviscous model which is simple and capable describing the hysteretic characteristics, is used for numerical studies. The capacity of MR damper is determined as a portion of not the building weight but the lateral restoring force. A method is proposed for optimal placement and number of MR dampers, and its effectiveness is verified by comparing it with the simplified sequential search algorithm. Numerical results indicate that the capacity, number and the placement can be reasonably determined using the proposed design procedure.

자기유변유체 댐퍼를 이용한 대형구조물의 반능동제어

  • 윤정방;구자인;김상범;전준보
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.127-132
    • /
    • 2001
  • 자기유변유체감쇠기를 이용한 반능동 제어 시스템은 최근에 개발되어 승용차의 승차감 향상을 위한 진동제어에 사용되고 있다. 본 연구에서는 바람, 지진, 파랑 등에 대한 대형구조물의 진동제어를 위한 MR 감쇠기의 적용성을 분석하기 위하여, 미국 토목학회에서 제안한 76층 건물의 풍하중에 대한 진동제어에 관한 Benchmark Problem에 대하여 수치모의 해석을 수행하였다. 연구결과로부터, 풍하중에 대한 고층 건물의 진동제어를 위하여 MR 감쇠기를 이용한 반능동 제어의 성능은 능동형 동조질량 감쇠기의 성능과 유사함을 확인할 수 있었다.

  • PDF

Analysis of a Non-proportionally Damped Structure Equipped with Viscoelastic Dampers Subjected to Stationary Wind Loads (점탄성감쇠기를 설치한 비비례 감쇠 구조물의 풍응답 해석)

  • 김진구;이창용
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.12 no.4
    • /
    • pp.649-659
    • /
    • 1999
  • 본 연구에서는 점탄성감쇠기가 설치된 비비례 감쇠 구조물의 바람에 대한 확률적 응답을 진동수영역에서 구하였다. 복소수 고유치 및 고유백터를 바탕으로 모드중첩법을 이용하여 응답의 RMS 값을 구하고 그것을 근사적인 방법인 모드 변형에너지법에서 얻은 결과와 비교하였다. 또한, 가력 진동수에 따라서 변하는 점탄성감쇠기의 강성 및 감쇠 계수를 상수로 모형화하였을 때의 풍응답 해석 결과의 정확성을 진동수영역에서 검증하였다. 해석결과에 의하면 감쇠기의 진동수 의존 특성은 구조물의 1차 고유 진동수에 의해서 비교적 정확하게 표현되었고, 모드 변형에너지법은 대체로 정확한 결과를 도출하였지만, 가속도 응답을 구할 때에는 다소 큰 오차를 유발하였다.

  • PDF

Optimal Design of Viscoelastic Dampers in Building Frames by Eigenvalue Assignment (건축구조물에서 고유값 지전에 의한 점탄성 감쇠기의 최적설계)

  • Son, Dong-In;Lee, Sang-Hyun;Park, Ji-Hun;Kim, Jin-Koo
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.5 no.2
    • /
    • pp.125-138
    • /
    • 2001
  • 고유진동수와 감쇠비는 지진이나 바람과 같은 동적 횡하중에 대해 구조물의 응답을 결정하는 주요한 특성이다. 본 연구는 지진하중에 대하여 목표응답 수준을 만족하는 구조물의 고유진동수와 감쇠비를 지정하고, 이 값을 실현하는 점탄성 감쇠기 파라미터의 처적분포를 구하는 설계방법을 제안한다. 여기서 지정할 고유진동수와 감쇠비는 목표응답 수준을 만족하는 여러 조합 중 설계조건과 원래 건물의 특성에 따라 결정될 수 있다. 제안한 설계방법은 점탄성 감쇠기의 감성 파라미터를 고유값의 기울기 정보를 바탕으로 분포시키므로 최적 위치와 크기에 대한 정보를 동시에 제공한다. 예제로서 평면 10층 전단 건물을 대상으로 최적설계를 수행하여 지정된 고유값을 실현하는 파라미터의 최적분포를 구하고 이를 통해 제안한 최적 설계의 특성을 확인하였다. 또한 더 나아가 3차원 일방향 비대칭 전단전물에 제안된 최적설계를 수행하여 그에 대한 적용가능성을 확인하였다.

  • PDF

Numerical Study of Hybrid Base-isolator with Magnetorheological Damper and Friction Pendulum System (MR 감쇠기와 FPS를 이용한 하이브리드 면진장치의 수치해석적 연구)

  • Kim, Hyun-Su;Roschke, P.N.
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.9 no.2 s.42
    • /
    • pp.7-15
    • /
    • 2005
  • Numerical analysis model is proposed to predict the dynamic behavior of a single-degree-of-freedom structure that is equipped with hybrid base isolation system. Hybrid base isolation system is composed of friction pendulum systems (FPS) and a magnetorheological (MR) damper. A neuro-fuzzy model is used to represent dynamic behavior of the MR damper. Fuzzy model of the MR damper is trained by ANFIS (Adaptive Neuro-Fuzzy Inference System) using various displacement, velocity, and voltage combinations that are obtained from a series of performance tests. Modelling of the FPS is carried out with a nonlinear analytical equation that is derived in this study and neuro-fuzzy training. Fuzzy logic controller is employed to control the command voltage that is sent to MR damper. The dynamic responses of experimental structure subjected to various earthquake excitations are compared with numerically simulated results using neuro-fuzzy modeling method. Numerical simulation using neuro-fuzzy models of the MR damper and FPS predict response of the hybrid base isolation system very well.