• Title/Summary/Keyword: 감쇠기

Search Result 978, Processing Time 0.026 seconds

Design of Ultra Wide Band MMIC Digital Attenuator with High Attenuation Accuracy (높은 감쇠 정확도를 가지는 초광대역 MMIC 디지털 감쇠기 설계)

  • Ju Inkwon;Yom In-Bok
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.2 s.105
    • /
    • pp.101-109
    • /
    • 2006
  • A broadband, DC to 40 GHz 5-bit MMIC digital attenuator has been developed. The ultra broadband attenuator has been achieved by adding transmission lines in the conventional Switched-T attenuator and optimizing the transmission line parameters. Momentum simulation was performed in design for accurate performance prediction at high frequencies and Monte Carlo analysis was applied to verify the performance stability against the MMIC process variation. The attenuator has been fabricated with $0.15\;{\mu}m$ GaAs pHEMT process. This attenuator has 1 dB resolution and 23 dB dynamic ranges. High attenuation accuracy has been achieved over all attenuation ranges and 40 GHz bandwidth with the reference state insertion loss of less than 6 dB at 20 GHz. The input and output return losses of the attenuator are better than 14 dB over all attenuation states and frequencies. The measured IIP3 of the attenuator is 33 dBm.

A Study on Fabrication of Variable Attenuator Using a Directional Coupler (방향성 결합기를 이용한 가변감쇠기의 설계 및 제작에 관한 연구)

  • 전중성;임종근;김동일;김기문
    • Journal of the Korean Institute of Navigation
    • /
    • v.25 no.4
    • /
    • pp.455-460
    • /
    • 2001
  • 본 연구에서는 방향성 결합기의 특성과 PIN다이오드의 특성을 이용하여 가변 감쇠기를 구현하였다. 기존의 Even-Odd Mode해석법이 아닌 간단한 2-port 기법으로 감쇠기를 분석하였으며, 산란 파라미터는 결합포트의 종단 임피던스가 동일한 경우와 동일하지 않은 경우에 있어서의 감쇠기의 동작특성을 평가하였다. 방향성 결합기의 결합포트는 가변종단을 HP사의 전류제어 소자인 HSMP-3864 PIN다이오드를 사용하였다. 구현된 가변감쇠기는 PCS 송신주파수 1.9 GHz에서 감쇠 범위가 30 dB 이상, 삽입손실 5 dB 이하, 입·출력 반사계수 -25 dB 이하의 특성을 나타내었으며, 이는 PCS와 셀룰러 이동통신 기지국용 전력 증폭기를 온도 등과 같은 외부의 환경변화에 따라서 이득을 가변 시킬 수 있으며, 또한 증폭기의 선형성을 향상시킬 것으로 사료된다.

  • PDF

Eigenvalue Analysis of the Building with Viscoelastic Dampers Using Component Mode Method (부분모드 방법을 이용한 점탄성 감쇠기가 설치된 건물의 고유치 해석)

  • 민경원;김진구;조한욱;이성경
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.2 no.1
    • /
    • pp.71-78
    • /
    • 1998
  • The eigenvalue problem is presented for the building with added viscoelastic dampers by using component mode method. The Lagrange multiplier formulation is used to derive the eigenvalue problem which is expressed with the natural frequencies of the building, the mode components at which the dampers are added, and the viscoelastic property of the damper. The derived eigenvalue problem has a nonstandard form for determining the eigenvalues. Therefore, the problem is examined by the graphical depiction to give new insight into the eigenvalues for the building with added viscoelastic dampers. Using the present approach the exact eigenvalues can be found and also upper and lower bounds of the eigenvalues can be obtained.

  • PDF

Semiactive Control of Cable-Stayed Bridges Using Full-Scale MR Fluid Dampers (실제규모의 자기유변 유체 감쇠기를 이용한 사장교의 진동제어)

  • Jung, Hyung-Jo;Park, Kyu-Sik;Ko, Man-Gi;Lee, In-Won
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2002.03a
    • /
    • pp.443-450
    • /
    • 2002
  • 본 논문에서는 미국토목학회(ASCE)의 사장교에 대한 첫번째 벤치마크 문제를 이용하여 제어-구조물 상호작용을 고려한 새로운 반능동 제어 기법을 제안하였다. 이 벤치마크 문제에서는 2003년 완공 예정으로 미국 Missouri 주에 건설 중인 Cape Girardeau 교를 대상 구조물로 고려하였다. Cape Girardeau 교는 New Madrid 지진구역에 위치하고, Mississippi 강을 횡단하는 주요 교량이라는 점 때문에 설계단계에서부터 내진 문제에 대하여 자세하게 고려되었다. 상세 설계 도면을 기반으로 하여 교량의 전체적인 거동 특성을 정확하게 나타낼 수 있는 3차원 모델이 만들어졌고, 사장교의 제어 성능에 관련된 평가 기준이 수립되었다. 본 연구에서는 제어 가능한 유체 감쇠기에 속하는 MR 유체 감쇠기를 제어 장치로 제안하였고, 기존 연구에서 MR 유체 감쇠기를 포함한 구조물의 제어에 효율적이라고 검증된 clipped-optimal 알고리듬을 제어 알고리듬으로 사용하였다. 또한, 실제 규모의 MR 유체 감쇠기 실험 결과를 이용하여 수치해석에 이용할 수 있는 동적 모델을 개발하였다. MR 유체 감쇠기는 제어 가능한 에너지 소산장치이며 구조물에 에너지를 가하지 않기 때문에 제안된 제어 기법은 한정입출력 안정성이 보장된다. 수치해석을 통해, MR 유체 감쇠기를 이용한 반능동 제어 기법이 사장교의 응답 감소에 효과적인 방법임을 증명하였다.

  • PDF

Seismic Behavior of Viscoelastically Damped Steel-Frame Structures (점탄성 감쇠기를 설치한 강구조건물의 지진하중에 대한 거동 연구)

  • 오순택
    • Computational Structural Engineering
    • /
    • v.6 no.1
    • /
    • pp.127-135
    • /
    • 1993
  • This paper summarizes a study on the application of viscoelastic dampers as an energy dissipation device in the frame structure. It can be concluded that, even at high temperatures, the viscoelastically damped structure can achieve a significant reduction of structural response as compared to the case with no dampers added. Empirical formulae for estimating the dynamic properties of the viscoelastic damper are established based on the regression analysis using data obtained from component tests of the damper. The structural damping with added dampers can be satisfactorily estimated by the modal strain energy method and the derived empirical formulae. Numerical simulations using conventional modal analysis methods are also carried out to predict the dynamic response of viscoelastically damped structures under seismic excitations. Comparison between numerical simulations and test results shows very good agreement. Based on the above studies, a design procedure for viscoelastically damped structures is present . This design procedure fits naturally into the conventional structural design flow-chart by including damping ratio an additional design parameter.

  • PDF

Development of Variable Voltage Sensing for Identification of Dynamic Characteristics of TLCDs (동조액체기둥감쇠기의 동적특성을 파악하기 위한 가변전압측정 시스템 개발)

  • Jang, Seok-Jung;Kim, Jun-Hee;Min, Kyung-Won
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.28 no.3
    • /
    • pp.275-281
    • /
    • 2015
  • In this study, vertical motion of a Tuned Liquid Column Damper(TLCD) is measured by a variable voltage measurement system in the electric field and design parameters of the TLCD are determined. First, nonlinear damping term of the TLCD is replaced as the equivalent viscous damping term. The natural frequency and damping ratio of dynamic characteristics of the TLCD are verified. In addition, a novel liquid level measurement system is developed for measuring vertical motion of the TLCD. For the experimental achievement, experimental characterizations of natural frequency and damping ratio of the TLCD are undertaken utilizing the developed variable voltage sensing. Also, shake table testing is performed to determine the dynamic characteristics of the TLCD. As a result, the feasibility of the proposed liquid level measurement system is verified by comparison with the capacitive type wavemeter.

Application of MR Damper for Vibration Control of Floor Slab (바닥판 구조물의 진동제어를 위한 MR 감쇠기의 적용)

  • Kim, Gee-Cheol;Kwak, Chul-Seung
    • Journal of Korean Association for Spatial Structures
    • /
    • v.6 no.3 s.21
    • /
    • pp.59-67
    • /
    • 2006
  • A conventional passive TMD is only effective when it is tuned properly. In many practical applications, inevitable off-tuning of a TMD occurs because the mass in a building floor could change by moving furnishings, people gathering, etc. when TMDs are offtuned, TMDs their effectiveness is sharply reduced. Moreover, the off-tuned nTMDs can excessively amplify the vibration levels of the primary structures. This paper discusses the application of a new class of MR damper, for the reduction of floor vibrations due to machine and human movements. The STMD introduced uses a MR damper called to semi-active damper to achieve reduction in the floor vibration. Here, the STMD and the groundhook algorithm are applied to a single degree of freedom system representative of building floors. The performance or the STMD is compared to that or the equivalent passive TMD. In addition, the effects of off-tuning due to variations in the mass of the floor system. Comparison of the results demonstrates the efficiency and robustness or STMD with respect to equivalent TMD.

  • PDF

Experimental Evaluation of Design Parameters for TLCD and LCVA (TLCD와 LCVA의 설계파라미터에 대한 실험적 평가)

  • Lee, Sung-Kyung;Min, Kyung-Won;Park, Ji-Hun
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.22 no.5
    • /
    • pp.403-410
    • /
    • 2009
  • In this paper, damping coefficients and effective masses of tuned liquid-type column dampers were quantitatively evaluated based on experimental results by using system identification technique. First, shaking table tests were performed for two types of tuned liquid-type column dampers. Then, the dynamic characteristics of dampers used in this study were experimentally grasped from harmonic wave excitation testing results of the dampers with various water level. Finally, damping ratios and effective masses of the dampers with varying water level were quantitatively evaluated from minimizing the errors between numerical and experimental results. It was confirmed from system identification results that damping ratio and effective mass are decreased as the water level of dampers is increased.

Seismic Behavior of Steel Structure with Added Viscoelastic Dampers under Strong Earthquake Ground Motions (점탄성 감쇠기를 설치한 강구조 건물의 강지진 하중에 의한 거동 연구)

  • Oh, Soon Taek
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.13 no.2
    • /
    • pp.111-120
    • /
    • 1993
  • This paper summarizes an experimental and analytical study on the application of viscoelastic dampers as energy dissipation devices in structural applications. It can be concluded the viscoelastic dampers are effective in reducing excessive vibrations of structures under strong earthquake ground motions. It is also found that the modal strain energy method can be used to reliably predict the equivalent structural damping, and the seismic response of a viscoelastically damped structure can be accurately estimated by conventional modal analysis techniques. Based on the above studies, a design procedure for viscoelastically damped structures is presented. This design procedure fits naturally into the conventional structural design flow chart by including damping ratio as an additional design parameter.

  • PDF

Performance Evaluation of the New Smart Passive Control Device using Shaking Table Test (진동대 실험을 통한 신개념 스마트 수동제진장치의 제진성능 평가)

  • Jang, Dong-Doo;Jung, Hyung-Jo;Moon, Seok-Jun
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.23 no.1
    • /
    • pp.27-35
    • /
    • 2010
  • This paper presents the vibration control performance of the smart passive control system to suppress the undesired vibration of the structure subjected to the earthquake loadings. Smart passive control system is the MR damper-based control system augmented with electromagnetic induction(EMI) device which consists of permanent magnets and solenoid coils. According to the Faraday's law of electromagnetic induction, an EMI device produces electrical energy from the mechanical energy due to the reciprocal motions of the structure and provide it to the MR damper. The smart passive control system can be the simple and easy to implement and maintain control system by replacing the feedback control system including sensors, controllers and external power sources of the conventional MR damper-based semiactive control system with the EMI device. The control performance of the smart passive control system is evaluated through the set of shaking table test considering the various historical earthquake loadings.