• Title/Summary/Keyword: 감쇠(damping)

Search Result 1,418, Processing Time 0.025 seconds

Estimation of Nonlinear Site Effects of Soil Profiles in Korea (국내 지반에서의 비선형 부지효과 예측)

  • Lee, Hong-Sung;Yun, Se-Ung;Park, Du-Hee;Kim, In-Tai
    • Journal of the Korean Geotechnical Society
    • /
    • v.24 no.3
    • /
    • pp.13-23
    • /
    • 2008
  • In a nonlinear site response analysis which is performed in time domain, small strain damping is modeled as viscous damping through use of various forms of Rayleigh damping formulations. Small strain damping of soil is known to be independent of the loading frequency, but the viscous damping is greatly influenced by the loading frequency. The type of Rayleigh damping formulation has a pronounced influence on the dependence. This paper performs a series of nonlinear analyses to evaluate the degree of influence of the viscous damping formulation on Korean soil profiles. Analyses highlight the strong influence of the viscous damping formulation for soil profiles exceeding 30 m in thickness, commonly used in simplified Rayleigh damping formulation overestimating energy dissipation at high frequencies due to artificially introduced damping. When using the full Rayleigh damping formulation and carefully selecting the optimum modes, the artificial damping is greatly reduced. Results are further compared to equivalent linear analyses. The equivalent linear analyses can overestimate the peak ground acceleration even for shallow profiles less than 20 m in thickness.

Optimization Design of Damping Devices for a Super-Tall Building Using Computational Platform (전산플랫폼을 이용한 초고층구조물의 감쇠장치 최적화 설계)

  • Joung, Bo-Ra;Lee, Sang-Hyun;Chung, Lan;Choi, Hyun-Chul
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.28 no.2
    • /
    • pp.145-152
    • /
    • 2015
  • In the study, the effects of damping devices on damping ratio increase and wind-load reduction were investigated based on the computational platform, which is one of the parametric modeling methods. The computational platform helps the designers or engineers to evaluate the efficacy of the numerous alternative structural systems for irregular Super-Tall building, which is crucial in determining the capacity and the number of the supplemental damping devices for adding the required damping ratios to the building. The inherent damping ratio was estimated based on the related domestic and foreign researches conducted by using real wind-load records. Two types of damping devices were considered: One is inter-story installation type passive control devices and the other is mass type active control devices. The supplemental damping ratio due to the damping devices was calculated by means of equivalent static analysis using an equation suggested by FEMA. The optimal design of the damping devices was conducted by using the computational platform. The structural element quantity reduction effect resulting from the installation of the damping devices could be simply assessed by proposing a wind-load reduction factor, and the effectiveness of the proposed method was verified by a numerical example of a 455m high-rise building. The comparison between roof displacement and the story shear forces by the nonlinear time history analysis and the proposed method indicated that the proposed method could simply but approximately estimate the effects of the supplemental damping devices on the roof displacement and the member force reduction.

Experimental study on the damping characteristics of a cylindrical structure containing oil and bearing balls (윤활유와 베어링 볼을 내장한 원통형 구조물의 감쇠특성에 관한 실험적 연구)

  • 류봉조;송선호
    • Journal of KSNVE
    • /
    • v.6 no.1
    • /
    • pp.107-114
    • /
    • 1996
  • The damping characteristics of a cylindrical structure containing oil and bearing balls is investigated for external bending forces. The experimental data obtained through the use of bearing balls with viscous oil in a column is given and analyzed. The viscous action of the oil and inertia effects of the balls on the inside of column create a drag force. The drag force dampens the vibration of the column. This study aims to search for an optimum combination of oil and balls which would produce maximum damping. Machining oils of various viscosities along with ball bearings of various sizes place inside cantilevered aluminium tubes of various diameters to create a rig on which the damping properties of the oil and balls can be studied. The contileved tubes are studied in both horizontal and vertical positions in order to gauge the effect of gravity on the system. The actions of the ball in the column and damping characteristics are investigated according to the dimensionless terms. The Buckingham theorem is used to reduce the variables and to predict the damping of an oil ball column. Though the damping ratio remains fairly constant in the horizontal position of column, the damping ratio begins to increase as the ratio of the number of balls and column length rise above 0.28 in the vertical position of oil ball column. The ratio of the ball diameter to column diameter influences the damping ratio with an optimum diameter ratio. Slenderness ratio and gravity effects on the damping ratio ane investigated.

  • PDF

Structural Damping Effects on Stability of a Cantilever Column under Sub-tangentially Follower Force (종동력을 받는 외팔기둥의 동적 안정성에 미치는 구조감쇠 효과)

  • Min, Dong-Ju;Park, Jae-gyun;Kim, Moon-Young
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.26 no.6_spc
    • /
    • pp.635-643
    • /
    • 2016
  • A stability theory of a damped cantilever column under sub-tangential follower forces is first summarized based on the stability map. It is then demonstrated that internal and external damping can be exactly transformed to Rayleigh damping so that the damping coefficients can be effectively determined using proportional damping. Particularly a parametric study with variation of damping coefficients is performed in association with flutter loads of Beck's column and it is shown that two damping coefficients can be correctly estimated for real systems under the assumption of Rayleigh damping. Finally a frequency equation of a cantilever beam subjected to both a sub-tangentially follower force and two kinds of damping forces is presented in the closed-form and its stability maps are constructed and compared with FE solutions in the practical range of damping coefficients.

Modal Analysis of a Building with Viscoelastic Dampers (점탄성 감쇠기를 설치한 건물의 모드해석)

  • 김진구;민경원
    • Computational Structural Engineering
    • /
    • v.11 no.1
    • /
    • pp.171-178
    • /
    • 1998
  • The added viscoelastic dampers increase damping and stiffness of buildings and results in so called non-classical or non-proportional damping problem. In this system the eigenvectors of the undamped system may not diagonalize the damping matrix, and the system is generally analyzed by converting the equation of motion into a 2n first order state-space form. As this approach is complex and time-consuming compared to the classically damped problem, the system is often analyzed by neglecting the off-diagonal terms in the damping matrix. In this paper the theoretical background of the approximate approach is studied, and the vibration characteristics of a three-story shear building with a viscoelastic damper are investigated using the exact and approximate method. It is found that the approximate method may produce good result when the additional damping is small, but as the damping increases the error also increase.

  • PDF

An Experimental Study on Effect of an Acoustic Resonator Position on Suppression of Pressure Oscillations in a Model Combustion Chamber (모형 연소실내 음향 공명기 장착 위치에 따른 압력 섭동 감쇠 효과에 관한 실험적 연구)

  • Sohn, Chae-Hoon;Kim, Chul-Hee;Park, Ju-Hyun
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.17-20
    • /
    • 2007
  • Effect of radial position of half-wave resonator is investigated experimentally for acoustic damping of tangential mode in a combustion chamber by adopting acoustic cold test. When resonator with optimal tuning length is installed, damping is enhanced as its radial location is away from the center of the faceplate. And, radial profile of damping factor is similar to that of the amplitude of the acoustic mode to be damped. As the location is close to the center, acoustic damping is mitigated and independent on the resonator length. on the other hand, the resonator with non-optimal length dose not show any effect of its radial position.

  • PDF

Design of Viscoelastic Dampers to Meet Performance Objectives (성능목표를 달성하기 위한 점탄성 감쇠기의 설계)

  • 김진구;최현훈
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.15 no.2
    • /
    • pp.329-339
    • /
    • 2002
  • This research presents a systematic design procedure for supplemental viscoelastic dampers required to satisfy the given performance objectives using capacity spectrum method. To obtain required damper size, the amount of supplemental damping was computed from effective damping minus equivalent damping and inherent damping of structure. In the case of viscoelastic damper, iterative procedure is required because of the inherent stiffness of the damper. To verify the design method proposed in this study, parametric studies were performed for single degree of freedom systems with design variables. The method was also applied to a 10-story steel framed structure and the earthquake responses were obtained. According to time history analysis result the controlled displacements turned out to be close to the target displacement regardless of the design parameters.

On the Damping of A Shock Absorption Device Composed of Disk Spring Stacks (디스크 스프링의 적층 배열에 따른 완충장치의 감쇠에 관한 연구)

  • Choi, Myung-Jin;Ko, Seok-Hoon
    • Journal of the Korean Institute of Gas
    • /
    • v.12 no.4
    • /
    • pp.46-51
    • /
    • 2008
  • The damping of a shock absorption device composed of nonlinear disk spring stacks and rubber rings was investigated. Friction forces of rubber rings and hysteresis of disk springs were obtained experimentally. The hysteresis curves of several types of disk spring stacks were approximated, from which the energy dissipated was estimated. Based upon the friction force and the energy dissipated, 4 damping models were presented and shock responses of the damping models were investigated. The hysteresis of disk spring is more meaningful than the friction of the rubber ring for the damping. For practical use, equivalent viscous damping model for total energy dissipated per cycle was suggested.

  • PDF

A Study on the Noise and Vibration Damping Performance of RC Hollow Core Slab (중공형 RC 슬래브의 소음 및 진동 감쇠성능에 대한 연구)

  • Kim, Dong Baek;Kim, In Bae;Kim, Jong Hoon;Lee, Jae Won
    • Journal of the Society of Disaster Information
    • /
    • v.15 no.2
    • /
    • pp.292-300
    • /
    • 2019
  • Purpose: To reduce the noise and vibration of reinforced concrete slab structures, the damping performance is to be performed experimentally after installing hollow core or filling it with liquid. Method: Using the hollow rate as an experimental variable, the damping ratio and stiffness of each test specimen at impact load are obtained to determine the difference between the damping ratio and stiffness of the numerical analysis. In addition, the damping effects are reviewed by comparing the difference in the damping ratio and stiffness of a test specimen filled with liquid 50% of the study. Results: Since the difference in resistance between a specimen with or without hollow core is 5%, it is judged that there is no structural problem, and the injection of liquid into the hollow core can increase the damping ratio, which can reduce noise or vibration. Conclusion: At less than 20% of hollow rate, there was little damping effect, and at 30%, damping effect was found. However, if liquid is injected into the hollow core of the specimen, damping rate is shown to increase, and the injection of liquid into the hollow part is believed to reduce noise or vibration.

Dynamic Damping Characteristics of Grouthed Coal Ash (약액처리된 석탄회의 동적 감쇠특성)

  • Chun, Byung Sik;Chung, Hyoung Sik;Koh, Yong Il;Lee, Hyoung Soo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.11 no.1
    • /
    • pp.145-151
    • /
    • 1991
  • The final purpose of this study is to examine the uses of coal ash, by-product from thermal power plant as a type of filling-embankment materials and the reuses of ash ponds. In this time, to investigate the dynamic properties, we made the test piece specimen with coal ashes, and obtained the damping ratio. In place(ash pond), the damping property by underground wall was investigated before and after soil improvements. The damping ratio of coal ash test piece specimen of 12% cement is the highest and that of 9% cement or chemical grout, that of 6% cement is in order. In same coal ash test piece, the damping ratio increases with decreasing the void ratio. In conclusion, it could be said that the damping ratio increases with the stiffness of materials. In the ash pond, the damping effect is the most when trench is set through the vibration wave propagation course, and when soil is improved the higher stiffness of the improved soil is, the more damping effect appeared. It is justified to obtain not only the dropping of permeability and the strength increase, but also the damping effect fairly by soil improvements.

  • PDF