• Title/Summary/Keyword: 감쇄측정시험

Search Result 29, Processing Time 0.029 seconds

Construction of Indoor Ground Station for Cubesat Communication Test (큐브위성 송수신시험을 위한 실내용 지상국 구축)

  • Han, Sanghyuck;Moon, Sangman;Shin, Dongyeop;Moon, SungTae;Gong, Hyeon Cheol;Choi, Gi-Hyuk
    • Aerospace Engineering and Technology
    • /
    • v.13 no.2
    • /
    • pp.73-79
    • /
    • 2014
  • During developing cubesat flight software, Communication test between cubesat and ground station is needed. For this, we have constructed indoor ground station without outdoor antenna for decreasing total cost and time. In this time, if output power of ground station is high, it will affect for cubesat transceiver to be fail. For solving this problem, ground station must be designed for output power of it to be lower than input power of cubesat satellite, and it must be verified. In this paper, first, we describe cubesat indoor ground station using UHF and VHF. Second, we describe output power decreasing test for indoor operation of ground station by attaching attenuators in the end of the output connector.

A Study on the Partial Discharge Pulse Attenuation of the EPR Retardant 15kV Cable (15kV급 EPR 난연 케이블의 부분방전신호 감쇄현상 연구)

  • Kim, Ki-Sang;Kwon, Hyun-Sook;Hong, Dong-Suk
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1610-1611
    • /
    • 2011
  • 실선로 전력 케이블의 부분방전 측정은 주위 전력설비의 신호들이 혼합되면 정확한 부분방전 진단이 어려운 면이 있다. 본 논문에서는 15kV급 EPR 난연 케이블을 대상으로 거리에 따른 부분방전 신호를 검출 및 감쇄 정도 확인 시험을 통하여 발생 위치 추정 기준을 마련하고자 한다. 이를 위해 길이 500m의 EPR 난연 케이블을 제작하여 모의 선로를 구성하였고, IEC60270에 적합한 Calibrator를 이용하여 신호를 인가한 후 HFCT 센서를 사용하여 일정한 거리를 두고 방전 신호를 검출하고, Techimp사(社)의 PDBASE와 OMICRON사(社)의 MPD600을 이용하여 부분방전 신호를 분류하였다. 전압 인가 지점에서 단계적인 거리증가에 따른 부분방전 신호 감쇄 현상 및 일정 길이(300[m])에 대한 주입 신호별 감도 측정을 분석하였다. 본 논문의 시험대상인 15kV급 EPR 난연 케이블은 원자력 발전소의 배전선으로 사용하기 위해 제작된 것으로, 포설 후 절연체 내에 B/D가 발생했다고 가정했을 때, PD신호의 검출 및 대략적인 위치의 추정은 안전을 최우선시 하는 원자력 발전 및 배전 부문에서 주요한 문제로 부각 될 것이다.

  • PDF

A design research on the L-band omnidirectional circular polarized wave antnna for telemetry ystem in vehicle performance test (차량성능계측 원격측정 시스템의 L-band 무지향성 원편파 안테나 설계연구)

  • 유제택;이장명;구상화
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.23 no.9A
    • /
    • pp.2391-2401
    • /
    • 1998
  • An L-band (1435-MHz~1535MHz) omnidirectional circular polarized wave antenna is designed and evaluated for transmitting/receiving of vehicle data. Conventioanl linear polarized wave antenna can not receive clearly all of the vehicle data which come from the wide driving test range on account of distortion. To vercome this problem, an omnidirectional circular polarized wave antenna is reuaried an designed. For the design, first of all, the charcteristics, design principle and theoretical background of circular polarized wav ewith a little signal loss ahve been reviewed. The characteristics of th edesigned antenna are analyzed wave with a little signal loss have been reviewed. The characteristics of the designed antenna is increased over 5dB comparing to that of linear polarized wave. Our results also demonstrate that the strength of vehicle data is flat enough over the full test range using this new antenna.

  • PDF

Design of Ku-band Channel Amplifier Engineering Model for Communication and Broadcasting Satellite Payload (통신방송위성 중계기용 Ku-대역 채널증폭기 시험 모델 설계)

  • 장병준;염인복;이성팔
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.13 no.10
    • /
    • pp.982-988
    • /
    • 2002
  • This paper summarizes the design concepts and implementation of a Ku-band channel amplifier's engineering model for the communication and broadcasting satellite applications. The selected architecture uses the analog gain control for the FGM(Fixed Gain Mode) and the output level limiting using automatic loop control for the ALC (automatic level control) mode. The Ku-band channel amplifier incorporates several state-of-the-art components including voltage-controlled PIN diode attenuators, and various temperature-compensation circuits. The measured characteristics of the Ku-band channel amplifier are in good agreement with the expected performance. The results show a fixed gain control of 28 dB, and an automatic level control of 16 dB over operating temperature range. The designed engineering model could be used as a channel amplifier for Ku-band communication and broadcasting satellite payload system.

Experimental study on the damping estimation of the 5$\times$5 rod bundle (5$\times$5 봉다발의 감쇄추정을 위한 실험적 연구)

  • Lee, Kang-Hee;Yoon, Kyung-Ho;Song, Kee-Nam
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.503-506
    • /
    • 2005
  • The PWR Nuclear Fuel assembly consists of more than 250 fuel rods that are supported by leaf springs in the cells of more than 10 Spacer Grids (SG) along the rod length. Since it is not easy to conduct mechanical tests on a full-scale model basis, the small-scaled rod bundle (5$\times$5) is generally used for various performance tests during the development stage. As one of the small-scaled tests, a flow test should be carried out in order to verify the performance of the spacer grid like the coolant mixing performance and to obtain the Flow-Induced Vibration (FIV) characteristics of the rod bundle over the specified flow range. A vibration test should be also performed to obtain the modal parameters of the bundle prior to the flow test. In this study, we want to develop the estimation procedure of the damping ratio for the small scaled test bundle. For the damping factor of the rod bundle and the grid case at the first vibration mode, as one of the vibration tests, a so-called pluck testing has been performed in air as a preliminary test prior to in-flow damping measurement test. Logarithmic decrement method is used for calculation of the damping ratio. Estimated damping ratio of the rod bundle is about 0.7% with reasonable error of 2% for the previous results. Nonlinear behavior of the rod bundle might be stem mainly Iron the rod-grid support configuration.

  • PDF

PLC Channel Characteristics of High Voltage Underground Distribution Line (고압 배전 지중선의 PLC 채널 특성)

  • Choi, In-Ji;Choi, Moon-Suk;Park, Byung-Seok;Hyun, Duck-Hwa
    • Proceedings of the KIEE Conference
    • /
    • 2006.07d
    • /
    • pp.2043-2044
    • /
    • 2006
  • 배전 계통을 대상으로 하는 통신 시스템에 전력통신(PLC : Power Line Communication)기술을 적용하고자 할 때, 고압 배전선의 통신 채널로서의 특성 분석이 근간이 되어야 한다. 일반적으로 지하 공동구의 배전 지중 케이블에는 케이블-케이블 간의 전기적, 물리적 접촉점인 접속 개소가 일정한 간격으로 존재하게 된다. 그러므로 통신 신호의 매개체가 되는 전력 케이블의 채널 특성 분석에는 케이블 접속 개소의 영향도 고려 대상이 되어야 한다. 본 논문에서는 서울시 광진구 일부의 부하를 담당하고 있는 22.9 kV 고압 배전 지중 선로를 시험 선로로 비접촉식 커플러를 통해 통신 신호를 전송하여 삽입 손실 측정 결과를 보았고 케이블 접속 개소의 영향을 주파수 영역에서 채널 특성을 통해 분석 하였다. 시험 결과 케이블 접속 개소를 통과할 때 채널 특성은 십여 dB의 신호 감쇄를 보였다.

  • PDF

Analysis on Shock Wave and Sensitivity of Explosives in Through-Bulkhead Initiator (격벽착화기 화약의 충격파와 민감도 분석)

  • Jang, Seung-gyo;Hwang, Jung-min;Baek, Sung-Hyun
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.21 no.4
    • /
    • pp.36-43
    • /
    • 2017
  • We studied attenuation characteristics of shock waves induced by a donor charge and the sensitivity of an acceptor for optimal design of a TBI (Through-bulkhead initiator). The attenuation behavior of shock waves was studied by measuring free surface velocity using a VISAR (Velocity Interferometer System for Any Reflector), and the sensitivity of the acceptor explosives was analyzed via SSGT (Small Scale Gap Test). It was found that the acceptor sensitivity obtained by the SSGT may be inappropriate for the design of the small-scale explosive devices such as TBI due to the different shock duration time.

Data Analysis of International Joint Road and Sea Transportation Tests Under Normal Conditions of Transport (국제공동 육해상 정상운반시험의 데이터 분석)

  • Lim, JaeHoon;Cho, Sang Soon;Choi, Woo-seok
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.18 no.2_spc
    • /
    • pp.275-289
    • /
    • 2020
  • In 2017, multimodal transportation tests for evaluating road, sea, and rail transport were performed by research institutes in the US, Spain, and the Republic of Korea. In this study, acceleration and strain data determined through road and sea tests were analyzed. It was investigated whether the load generated for each transport mode was amplified or attenuated according to the load transfer path. From the results, it was confirmed that the load transfer characteristics differed according to the transportation mode and loading path. The effects of strain determined through each test on the structural integrity of the spent nuclear fuel were also investigated. It was found that the magnitude of the measured strain had a negligible effect on the structural integrity of the spent nuclear fuel, considering its fatigue strength. The results for the acceleration and strain data analyses obtained in this study will be useful for scheduled domestic transportation tests under normal transport conditions.

Improvement of Microwave Water Surface Current Meter and its Commercialization (전자파표면유속계의 성능개선 및 실용화)

  • Kim, Young-Sung;Lee, Hyun-Seok
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2011.05a
    • /
    • pp.85-85
    • /
    • 2011
  • 홍수기에 안전하고 정확한 유량측정을 통하여 물관리에 필요한 기초수문자료를 확보하고자 한국수자원공사에서 1993년도부터 홍수유량측정기술 확보를 위한 연구를 시작하였다. 그간의 연구성과를 바탕으로 1999년도에 하천의 유속을 비접촉식으로 측정할 수 있는 홍수용 전자파표면유속계를 개발하여 특허등록하였고 그와 동시에 이의 상품화를 추진하여 2010년도까지 75대를 보급하여 실무에서 이용하고 있다. 이동식인 홍수용 전자파표면유속계를 바탕으로 2001년도에는 고정식 실시간 홍수유량측정측정시스템을 개발하여 특허등록하였고, 이 시제품을 현재 용담 수자원시험유역의 동향지점에서 시험운영하고 있다. 또한, 현장 유량측정실무자들의 홍수용 전자파표면유속계 개선요구에 따라 편각용 전자파표면유속계 시제품을 개발하였으며, 이는 임의의 한 지점에 설치한 한 대의 장비로 좌우 여러 측선의 유속을 동시에 측정할 수 있는 다점 측정기능을 갖도록 성능을 개선하였다. 이에 따라 홍수시 유량측정에 소요되는 시간이 줄어들어 신속하게 유량측정을 완료할 수 있는 계기를 마련하였다. 이와 더불어 유속측정 범위를 확장하여 홍수시의 고유속 뿐만 아니라 0.5 m/s 이하의 저유속까지 측정할 수 있는 범용 전자파표면유속계의 시제품을 추가로 개발하였다. 이 장비는 최저유속 0.03 m/s의 측정을 실내시험을 통하여 입증하였다. 범용 전자파표면유속계는 상품화 시제품의 개발을 목표로 기존 시제품의 현장시험을 통하여 현장적용상의 문제점에 대한 해결에 주력하였다. 첫째, 평갈수용 전자파표면유속계의 사용편의를 개선하기 위하여 소형화 및 경량화를 추진하였고, 이를 위하여 사용주파수를 기존의 10 GHz에서 24 GHz로 변경함으로써 $35{\times}35\;cm$ 크기의 기존안테나를 $22{\times}22\;cm$ 크기로 소형화하였으며 송수신부의 무게는 기존 18 kg에서 3.3 kg으로 혁신적으로 줄이는데 성공하였다. 이를 위하여 안테나는 기존의 반사형안테나에서 도파관슬롯배열안테나로 변경하였다. 둘째, 측정값의 안정화를 위하여 안테나의 특성을 개선하여 부엽(side-lobe) 레벨 30 dB 이하 그리고 전후방비(front-back ratio) 50 dB 이하로 개선하여 안테나가 지향하는 방향 이외의 위치에서 반사되는 불필요한 신호를 줄였다. 또한 적응형 이득제어(adaptive gain control)기법의 채택으로 미소 신호에 대한 안정적 측정 및 과다 신호에 대한 능동적 감쇄를 할 수 있도록 시스템을 구성하여 전 유속범위에 대한 안정적 측정을 가능토록 설계 및 제작하였다. 셋째, 자가점검 기능을 탑재하여 유속측정 전에 기기의 상태에 대한 self test기능을 통하여 측정자가 기기의 상태를 사전에 파악 가능토록함으로써, 기기 오작동에 대한 능동 대처할 수 있도록 하였다. 이외에도 저전력 회로설계를 통하여 배터리 사용시간을 확장하였고, 기존의 전자파표면유속계가 가지고 있던 방습 및 방수에도 내성을 갖는 제품으로 설계하였으며 스마트기기를 이용한 무선측정 및 세련된 디자인 등 사용자의 요구사항을 충분히 반영하였다.

  • PDF

Transport and Fate of Benzene in a Sandy Soil (사질토양에서의 Benzene의 이동성에 관한 연구)

  • 백두성;김동주
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.6 no.2
    • /
    • pp.95-100
    • /
    • 1999
  • Hydrocarbon compounds in vadose zone soils caused by adsorption onto the surfaces of solid particles are generally considered to show retardation effect. In this study, we investigated the retardation effect on the transport of Benzene in a sandy soil by conducting batch and column tests. The batch test was conducted by equilibrating dry soil mass with Benzene solutions of various initial concentrations. and by analyzing the concentrations of Benzene in initial and equilibrated solutions using HPLC. The column test consisted of monitoring the concentrations of effluent versus time known as a breakthrough curve (BTC). We used KCl and Benzene solutions with the concentration of 10 g/L and 0.88 g/L as a tracer, and injected them into the inlet boundary of the soil sample as a square pulse type respectively, and monitored the effluent concentrations at the exit boundary under a steady state condition using an EC-meter and HPLC. From the batch test, we obtained a distribution coefficient assuming that a linear adsorption isotherm exists and calculated the retardation factor based on the bulk density and porosity of the column sample. We also predicted the column BTC curve using the retardation factor obtained from the distribution coefficient and compared with the measured BTC of Benzene. The results of the column test showed that i) the peak concentration of Benzene was much smaller than that of KCl and ⅱ) the travel times of peak concentrations for the two tracers were more or less identical. These results indicate that adsorption of Benzene onto the sand panicles occurred during the pulse propagation but the retardation of Benzene caused by adsorption was not present in the studied soil. Comparison of the predicted with the measured BTC of Benzene resulted in a poor agreement due to the absence of the retardation phenomenon. The only way to describe the absolute decrease of Benzene concentration in the column leaching experiment was to introduce a decay or sink coefficient in the convection-dispersion equation (CDE) model to account for an irreversible sorption of Benzene in the aqueous phase.

  • PDF