• Title/Summary/Keyword: 감마-선

Search Result 1,498, Processing Time 0.025 seconds

The Correlations of Parameters Using Contrast Enhanced Ultrasonography in the Evaluation of Prostate Cancer Angiogenesis (전립선암쥐모형의 신생혈관생성의 평가를 위해 시행된 역동적 조영 증강 초음파에서 얻은 변수간의 상관성연구)

  • Hwang, Sung Il;Lee, Hak Jong;Kim, Kil Joong;Chung, Jin-haeng;Jung, Hyun Sook;Jeon, Jong June
    • Ultrasonography
    • /
    • v.32 no.2
    • /
    • pp.132-142
    • /
    • 2013
  • Purpose: The purpose of this study is to investigate the correlations of various kinetic parameters derived from the time intensity curve in a xenograft mouse model injected with a prostate cancer model (PC-3 and LNCaP) using an ultrasound contrast agent with histopathologic parameters. Materials and Methods: Twenty nude mice were injected with human prostate cancer cells (15 PC-3 and five LNCaP) on their hind limbs. A bolus of $500{\mu}L$ ($1{\times}10^8$ microbubbles) of second-generation US contrast agent (SonoVue) was injected into the retroorbital vein. The region of interest was drawn over the entire tumor. The time intensity curve was acquired and then fitted to a gamma variate function. The maximal intensity (A), time to peak (Tp), maximal wash-in rate (washin), washout rate (washout), area under the curve up to 50 sec ($AUC_{50}$), area under the ascending slope ($AUC_{in}$), and area under the descending slope ($AUC_{out}$) were derived from the parameters of the gamma variate fit. Immunohistochemical staining for VEGF and CD31 was performed. Tumor volume, the area percentage of VEGF stained in a field, and the count of CD31 (microvessel density, MVD) positive vessels showed correlation with the parameters from the time intensity curve. Results: No significant differences were observed between the kinetic and histopathological parameters from each group. MVD showed positive correlation with A (r=0.625, p=0.003), washin (r=0.462, p=0.040), $AUC_{50}$ (r=0.604, p=0.005), and $AUC_{out}$ (r=0.587, p=0.007). Positive correlations were also observed between tumor volume and $AUC_{50}$ (r=0.481, p=0.032), washin (r=0.662, p=0.001), and $AUC_{out}$ (r=0.547, p=0.012). Washout showed negative correlations with MVD (r=-0.454, p=0.044) and tumor volume (r=-0.464, p=0.039). The area percentage of VEGF did not show any correlation with calculated data from the curve. Conclusion: MVD showed correlations with several of the kinetic parameters. CEUS has the potential for prediction of tumor vascularity in a prostate cancer animal model.

Assessment for the Utility of Treatment Plan QA System according to Dosimetric Leaf Gap in Multileaf Collimator (다엽콜리메이터의 선량학적엽간격에 따른 치료계획 정도관리시스템의 효용성 평가)

  • Lee, Soon Sung;Choi, Sang Hyoun;Min, Chul Kee;Kim, Woo Chul;Ji, Young Hoon;Park, Seungwoo;Jung, Haijo;Kim, Mi-Sook;Yoo, Hyung Jun;Kim, Kum Bae
    • Progress in Medical Physics
    • /
    • v.26 no.3
    • /
    • pp.168-177
    • /
    • 2015
  • For evaluating the treatment planning accurately, the quality assurance for treatment planning is recommended when patients were treated with IMRT which is complex and delicate. To realize this purpose, treatment plan quality assurance software can be used to verify the delivered dose accurately before and after of treatment. The purpose of this study is to evaluate the accuracy of treatment plan quality assurance software for each IMRT plan according to MLC DLG (dosimetric leaf gap). Novalis Tx with a built-in HD120 MLC was used in this study to acquire the MLC dynalog file be imported in MobiusFx. To establish IMRT plan, Eclipse RTP system was used and target and organ structures (multi-target, mock prostate, mock head/neck, C-shape case) were contoured in I'mRT phantom. To verify the difference of dose distribution according to DLG, MLC dynalog files were imported to MobiusFx software and changed the DLG (0.5, 0.7, 1.0, 1.3, 1.6 mm) values in MobiusFx. For evaluation dose, dose distribution was evaluated by using 3D gamma index for the gamma criteria 3% and distance to agreement 3 mm, and the point dose was acquired by using the CC13 ionization chamber in isocenter of I'mRT phantom. In the result for point dose, the mock head/neck and multi-target had difference about 4% and 3% in DLG 0.5 and 0.7 mm respectively, and the other DLGs had difference less than 3%. The gamma index passing-rate of mock head/neck were below 81% for PTV and cord, and multi-target were below 30% for center and superior target in DLGs 0.5, 0.7 mm, however, inferior target of multi-target case and parotid of mock head/neck case had 100.0% passing rate in all DLGs. The point dose of mock prostate showed difference below 3.0% in all DLGs, however, the passing rate of PTV were below 95% in 0.5, 0.7 mm DLGs, and the other DLGs were above 98%. The rectum and bladder had 100.0% passing rate in all DLGs. As the difference of point dose in C-shape were 3~9% except for 1.3 mm DLG, the passing rate of PTV in 1.0 1.3 mm were 96.7, 93.0% respectively. However, passing rate of the other DLGs were below 86% and core was 100.0% passing rate in all DLGs. In this study, we verified that the accuracy of treatment planning QA system can be affected by DLG values. For precise quality assurance for treatment technique using the MLC motion like IMRT and VMAT, we should use appropriate DLG value in linear accelerator and RTP system.

Measurement of MDA of Soil Samples Using Unsuppression System and Compton Suppression of Environmental Radioactivity in Processing Technology (환경 방사능 처리기술에서의 Compton suppression 및 Unsuppression system을 이용한 토양시료의 MDA 측정)

  • Kang, Suman;Im, Inchul;Lee, Jaeseung;Jang, Eunsung;Lee, Mihyeon;Kwon, Kyungtae;Kim, Changtae
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.6
    • /
    • pp.293-299
    • /
    • 2014
  • Compton suppression device is a device by using the Compton scattering reaction and suppress the Compton continuum portion of the spectrum, so can be made more clear analysis of gamma ray peak in the Compton continuum region. Measurements above background occurs or, radioactivity counts of radioactivity concentration value of $^{40}K$ nuclides $^{137}Cs$ and natural radioactivity artificial radioactivity detected from the surface soil sample, unwanted non-target analysis and interference peak who dotted line you know the calibration of the measurement energy is allowed to apply the (Compton suppression) non-suppressed spectrum inhibition spectrum and (Compton Unsuppression) the background to the measured value of the activity concentration value of the standard-ray source is detected relative to the peak of By measuring according to the different distances cause $^{137}Cs$, and comparative analysis of the Monte Carlo simulation, in order to obtain a detection capability for efficient, looking at the Compton inhibitor, as the CSF value increases with increase in the distance, more It was found that the background due to Compton continuum of the measured spectrum suppression mode Compton unrestrained mode can know that the Compton suppression many were made, using a $^{137}Cs$ is reduced.

Prediction of Reservoir Properties Using Extended Elastic Impedance Inversion (확장 탄성 임피던스 역산을 이용한 저류층 물성 예측)

  • Kim, Hyeonju;Lee, Gwang H.;Moon, Seonghoon
    • Economic and Environmental Geology
    • /
    • v.48 no.2
    • /
    • pp.115-130
    • /
    • 2015
  • Extended elastic impedance (EEI) is an extension of elastic impedance (EI) which is a generalization of acoustic impedance (AI) for nonzero angles of incidence and can be tuned to be proportional to reservoir properties. In this study, we evaluated EEI inversion by estimating the P-($V_p$) and S-wave velocities ($V_s$), P-wave to S-wave velocity ratio ($V_p/V_s$), and Poisson's ratio of the Second Wall Creek Sand of the Teapot Dome field, Wyoming, USA. We also applied the EEI inversion technique to estimate porosity, gamma-ray values, and density of the Second Wall Creek Sand. Data used in the study include 3-D pre-stack seismic data from the southern part of the field and four wells, selected from a large well database. The $V_s$ logs at the wells were constructed from the $V_p$ logs using the empirical relationships. The percent prediction errors for the four velocity properties are less than about 5% except for Poisson's ratio at one well, supporting that the EEI inversion can be used in the prediction of rock properties. However, the results from the EEI inversion analysis of porosity, gamma-ray values, and density at the wells were unsatisfactory and thus these properties, which are not directly computed from velocities, may not be suitable for EEI inversion.

Two-Dimensional Electrophoresis Analysis of Proteins between Bacillus licheniformis DM3 and Its Antifungal Activity Deficient Mutant (이차원전기영동법을 이용한 길항세균 Bacillus licheniformis DM3와 이의 항진균 활성 결여 돌연변이균주간 단백질 비교 분석)

  • Lee, Young-Keun;Kim, Jae-Sung;Chung, Hye-Young;Jang, Yu-Sin;Jang, Byung-Il
    • Korean Journal of Environmental Agriculture
    • /
    • v.22 no.3
    • /
    • pp.203-209
    • /
    • 2003
  • In the course of screening for antifungal agents, a bacterial strain, DM3 was isolated from a mud sample collected at Daechon in Chungnam province and identified as Bacillus licheniformis based on API 50CHB test. It has antifungal activity against 12 plant pathogenic fungi in paper disc assay. At the 95% lethal dose of gamma radiation ($^{60}Co$, 10 kGy, $D_{10}=2.32\;kGy$), the antifungal activity deficient mutant (mDM3) against Colletotrichum gloeosporioides was induced From 2-D electrophoresis analysis, serine hydroxymethyltransferase (45.0 kDa), hypothetical protein(40.7 kDa), NifU protein homolog(15.4 kDa), and resolvase(12.5 kDa) homologous proteins were detected only in B. licheniformis DM3. Lysozyme(18.1 kDa) and alkyl hydroperoxide reductase(15.6 kDa) homologous proteins were expressed uniquely in B. licheniformis mDM3. Further studies are needed to reveal that these proteins from B. licheniformis DM3 could be closely related to the antifungal activity against plant pathogenic fungi.

Effects of Low Dose Gamma Radiation and Seed Moisture Content on Germination and Early Growth of Vegetable Crops (저선량 방사선 조사 시 종자수분함량이 채소류의 발아와 초기생장에 미치는 영향)

  • Baek, Myung-Hwa;Lee, Young-Keun;Lee, Young-Bok;Yang, Seung-Gyun;Kim, Jae-Sung
    • Korean Journal of Environmental Agriculture
    • /
    • v.22 no.3
    • /
    • pp.215-219
    • /
    • 2003
  • To investigate the effects of low dose gamma radiation and seed moisture content (SMC) on germination and early growth of vegetable crops, seeds of chinese cabbage (Brassica campestris L.), radish (Raphanus sativus L.), red pepper (Capcicum annuum L.), figleaf gourd (Cucurbita ficifolia Bouche) and bottle gourd (Lagenaria siceraria Standl), with different SMC were irradiated with different doses ($0{\sim}20\;Gy$) of gamma-ray by irradiator ($^{60}Co$, ca.150 TBq of capacity, AECL). Vegetable crops in which low dose gamma radiation was irradiated in seeds with different moisture content showed different response in seed germination and early growth to low dose gamma radiation. The germination rate of chinese cabbage, figleaf ground and bottle gourd irradiated with $2{\sim}8\;Gy$ showed interactive responses against relative SMC. Also, significant interactions occurred for the early growth between those factors. The stimulating effects of gamma radiation were more pronounced for hydrated seeds of chinese cabbage, radish, figleaf gourd and bottle gourd showing prominent responses with $2{\sim}10\;Gy$ irradiation, particularly for chinese cabbage and bottle gourd. These results suggest that radiation may promote germination and early growth of vegetable crops through interaction with SMC.

Response Function of HPGe Detector using $^{23}Na$(p, $\gamma$)$^{24}Mg$ and $^{27}Al$(p, $\gamma$)$^{28}Si$ Reaction ($^{23}Na$(p, $\gamma$)$^{24}Mg$$^{27}Al$(p, $\gamma$)$^{28}Si$반응을 이용한 HPGe 검출기의 응답함수)

  • Park, Sang-Tae
    • Journal of Radiation Protection and Research
    • /
    • v.35 no.2
    • /
    • pp.85-90
    • /
    • 2010
  • In the present work, peak relative efficiency for the energy was obtained and response function was worked out. This study was carried out using the high resolution high efficiency HPGe detector(diameter 78.7 mm, length 86.5 mm) and NaI(Tl) detector for anti-compton. The anti-coincidence of the signals from the two detectors could be used to lessen the Compton effect signal; thus, the $\gamma$-ray energy resolution could be improved. The $\gamma$-ray spectrum was measured at $55^{\circ}$ to the direction of the incident proton beam. Reaction spectrum was obtained from the $^{23}Na$(p, $\gamma$)$^{24}Mg$ reaction at $E_p$ = 1424 keV and $^{27}Al$(p, $\gamma$)$^{28}Si$ reaction at $E_p$ = 992 keV. To accelerate the incident proton which creates the (p, $\gamma$) capture reaction, the 3 MeV Pelletron accelerator at the Tokyo Institute of Technology was used. Response function was worked out by a noble technique. We worked out a response function from 1.2 to 9.4 MeV at intervals of 0.75 MeV.

Performance Evaluation of Component Detectors of Double-scattering Compton Camera (이중 산란형 컴프턴 카메라 구성 검출기 성능 평가)

  • Seo, Hee;Park, Jin-Hyung;Kim, Chan-Hyeong;Lee, Ju-Hahn;Lee, Chun-Sik;Lee, Jae-Sung
    • Journal of Radiation Protection and Research
    • /
    • v.35 no.2
    • /
    • pp.69-76
    • /
    • 2010
  • Prototype double-scattering Compton camera, which consists of three gamma-ray detectors, that is, two double-sided silicon strip detectors (DSSDs) as scatterer detectors and a NaI(Tl) scintillation detector as an absorber detector, could provide high imaging resolution with a compact system. In the present study, the energy resolution and the timing resolution of component detectors were measured, and the parameters affecting the energy resolution of the DSSD were examined in terms of equivalent noise charge (ENC). The energy resolutions of the DSSD-1 and DSSD-2 were, in average, $25.2keV{\pm}0.8keV$ FWHM and $31.8keV{\pm}4.6keV$ FWHM at the 59.5 keV peak of $^{241}Am$, respectively. The timing resolutions of the DSSD and NaI(Tl) scintillation detector were 57.25 ns FWHM and 7.98 ns FWHM, respectively. In addition, the Compton image was obtained for a point-like $^{137}Cs$ gamma source with double-scattering Compton camera. From the present experiment, the imaging resolution of 8.4 mm FWHM (angular resolution of $8.1^{\circ}$ FWHM), and the imaging sensitivity of $1.5{\times}10^{-7}$ (intrinsic efficiency of $1.9{\times}10^{-6}$) were obtained.

Analysis of the Physical Properties of Ground before and after Low Flowing Grouting (저유동성 그라우팅 시공전후 지반의 물성변화 분석)

  • Seo, Seok-Hyun;Lee, Jung-Sang;Kang, Won-Dong;Jung, Euiyoup
    • Journal of the Korean Geosynthetics Society
    • /
    • v.18 no.4
    • /
    • pp.115-127
    • /
    • 2019
  • The low-flow grouting injection technique, the target construction method for this study, is a method of pouring mortar into the ground by non-emission replacement principle, which can be expected to increase the density of the ground, and, in some cases, be used as a base file using the strength of the high injection solids, along with low noise, low pollution, and high durability. To verify that the dynamic characteristics of the ground are improved by the low-flow injection technique, the test work was conducted on the site and physical tests were performed, and the quality of the improvement formed in the ground was verified through the indoor test on the core and core recovery rate was analyzed. The density logs test layer calculated the volume density of the ground layer by using the Compton scattering of gamma-rays, and the sonic logs was tested on the ground around the drill hole using a detector consisting of sonar and receiver devices inside the drill hole. As a result of the measurement of the change in physical properties (density and sonic logs) before and after grouting, both properties were basically increased after infusion of grout agent. However, the variation in density increase was greater than the increase in speed after grouting, and the ground density measurement method was thought to be effective in measuring the fill effect of the filler. Strength and core recovery rates were measured from specimens taken after the age of 28 days, and the results of the test results of the diffusion and strength test of the improved products were verified to satisfy the design criteria, thereby satisfying the seismic performance reinforcement.

A Study on the Apron Shielding Ratio According to Electromagnetic Radiation Energy (감마선 에너지에 따른 납치마의 차폐효과 분석)

  • Jang, Dong-Gun;Lee, Sang-Ho;Choi, Hyung-Seok;Son, Joo-Chul;Yoon, Chang-Yong;Ji, Yung-Sik;Cho, Yong-In;Lee, Hong Je;Yang, Seoung-Oh
    • Journal of radiological science and technology
    • /
    • v.37 no.4
    • /
    • pp.247-252
    • /
    • 2014
  • The medical institution has been used electromagnetic radiation of various energy. But researchers are divided on whether using apron for radiation shielding will be effective or not. The purpose of present study was to analyze electromagnetic radiation shielding effect of apron by using Monte carlo simulation. 1 MBq electromagnetic radiation was emitted from 10-500 keV at 10 keV increments in Monte carlo simulation. Then shielded radiation dose difference was confirmed, when 0.25 mmPb shield use for shielding. As a results, shielding ratio was markedly decreased in high energy electromagnetic radiation. The radiation dose was inversely increased with 0.25 mmPb shielding.