• Title/Summary/Keyword: 감마-선

Search Result 1,495, Processing Time 0.022 seconds

A Study on Optimized Design of Wideband Pulsed Gamma-ray Detectors (광대역 펄스감마선 탐지센서 최적화설계에 관한 연구)

  • Jeong, Sang-hun;Lee, Nam-ho;Son, Eui-seung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.10a
    • /
    • pp.1121-1124
    • /
    • 2015
  • In this paper, we propose and demonstrate an optimal design of wideband pulsed gamma-ray detectors. Pulsed gamma-ray detectors are designed to operate in a dose rate of $1{\times}10^6{\sim}1{\times}10^8rad(Si)/s$. The input parameter was derived based on the energy ratio of pulse gamma-ray spectrum and the time of the energy. The sensor output current was calculated based on the dose rate control circuit. Using the N-type Epi Wafer, the optimum condition detection sensor was designed based on TCAD. The simulation results show that the optimal Epi layer thickness is 45um when applied voltage 3.3V. The doping concentrations are as follows : N-type is an Arsenic as $1{\times}10^{19}/cm^3$, P-type is a Boron as $1{\times}10^{19}/cm^3$ and Epi layer is Phosphorus as $3.4{\times}10^{12}/cm^3$. Pulse gamma-ray detector diameter is the 1.3mm.

  • PDF

Evaluation of the Sensory Quality Characteristics during Storage and Mutagenicity of Gamma-irradiated Sujeonggwa Powder (Korean Traditional Cinnamon Beverage) (감마선 조사 분말수정과의 저장 중 관능적 품질특성 및 유전독성학적 안전성 평가)

  • Lee, Hyun-Ja;Sul, Min-Sook;Park, Jae-Nam;Kim, Jae-Hun;Song, Beom-Seok;Lee, Ju-Woon;Byun, Myung-Woo
    • Food Science and Preservation
    • /
    • v.14 no.4
    • /
    • pp.408-413
    • /
    • 2007
  • This study evaluated the sensory quality characteristics of gamma-irradiated Sujeonggwa a Korean traditional cinnamon beverage during storage, and the mutagenicity of the beverage. The minimum irradiation dose required to ensure the microbiological safety of powdered Sujeonggwa was 4.5 kGy. Sensory characteristics, and the Hunter's color value, of Sujeonggwa, deteriorated with increased irradiation doses, but no significant changes in sensory qualities were found during storage. The Ames test yielded no evidence that gamma irradiation induced mutagenicity in Sujeonggwa powder.

Microarray Analysis of Radiation Related Gene Expression in Mutants of Bacillus lentimorbus WJ5 Induced by Gamma Radiation (Bacillus lentimorbus WJ5의 감마선유도 돌연변이체들에서 공통으로 발현되는 방사선 관련 유전자의 microarray 분석)

  • Lee Young-Keun;Chang Hwa-Hyoung;Jang Yu-Sin;Huh Jae-Ho;Hyung Seok-Won;Chung Hye-Young
    • Korean Journal of Environmental Biology
    • /
    • v.22 no.3
    • /
    • pp.472-477
    • /
    • 2004
  • To study the radiation related gene expression in mutants of Bacillus lentimorbus WJ5 induced by gamm radiation, the simultaneous gene expression was analyzed by DNA micro array. We constructed DNA chips including two thousand randomly digested genome spots of B. lentimorbus WJ5 and compared its quantitative aspect with seven mutants induced by gamma radiation $(^{60}/Co)$. From the cluster analysis of gene expression pattern, totally 408 genes were expressed and 27 genes were significantly upregulated by the gamma radiation in all mutants. Especially, genes involved in repair (mutL, mutM), energy metabolism (acsA, sdhB, pgk, yhjB, citB), protease (npr), and reduction response to oxidative stress (HMM) were simultaneously upregulated. It seems that the induction of the direct and/or indirect repair related genes in mutants induced by gamma radiation could be remarkably different from the adaptive responses against acute exposure to radiation.

Improvement of the Hygienic Quality and Shelf-life of Kwamegi from Cololabis seira by Gamma Irradiation (꽁치과메기의 위생적 품질개선 및 저장기간 연장을 위한 감마선 조사)

  • Cho, Kyung-Hwan;Lee, Ju-Woon;Kim, Jae-Hun;Ryu, Gi-Hyung;Yook, Hong-Sun;Byun, Myung-Woo
    • Korean Journal of Food Science and Technology
    • /
    • v.32 no.5
    • /
    • pp.1102-1106
    • /
    • 2000
  • This study was carried out to investigate the effects of gamma irradiation for the improvement of hygienic quality and the extension of shelf-life of Kwamegi(semi-dried colobabis seira). Kwamegi was stored at $5^{\circ}C$ and $15^{\circ}C$ after gamma irradiation with doses of 0, 3, 5, 7 and 10 kGy. In microbiological aspects, non-irradiated Kwamegi was rapidly deteriorated during storage, and some harmful bacteria were detected in a microbial analysis using a selective medium. However, the total viable cells and presumptive pathogens were reduced with the increase of irradiation dose, and dose level of 7 to 10 kGy was considered to be optimum and effective dose for the preservation of Kwamegi.

  • PDF

A Monitoring Ability of the High-Performance Color CCD Camera under High Dose-Rate Gamma Ray Irradiation Environments (고 선량율 감마선 조사 환경에서의 고성능 칼라 CCD 카메라의 관측성능)

  • Cho, JaiWan;Choi, Young Soo;Seo, Yong Chil;Jeong, KyungMin
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2014.04a
    • /
    • pp.811-814
    • /
    • 2014
  • 일본 후쿠시마 제일 원자력발전소의 대지진/쓰나미에 이은 원자로 건물 수소폭발 사고의 수습 과정에서 사용후 핵연료 저장조에 보관되어 있는 핵연료의 안전문제가 대두되었다. 사용후 핵연료의 잔열 성분을 냉각시키고, 그리고 사용후 핵연료가 방출하는 고선량 방사선을 차폐시키기 위해서 일정 깊이 이상의 수조에 사용후 핵연료를 저장한다. 사용후 핵연료 저장조에 냉각수 공급이 중단되면, 사용후 핵연료의 고유 잔열에 의해 수조의 물이 증발하여 수위가 감소하게 된다. 계속해서 냉각수 공급이 되지 않으면, 사용후 핵연료의 잔열은 증가하게 되고, 수조의 물은 비등하여 증발은 가속화 된다. 사용후 핵연료 저장조의 수위가 고갈되면 고선량의 감마선이 방출된다. 수조의 수위가 정상적일 경우 사용후 핵연료 저장조의 공기중 감마선 선량율은 0.15mSv/h 이다. 수조의 수위가 사용후 핵연료 상부 꼭대기를 기준으로 2m, 1m, 및 0m (핵연료 노출) 로 감소하게 되면, 사용후 핵연료 저장조의 공기중 감마선 선량율은 500mSv/h, 50Sv/h, 및 5kSv/h 로, 급격히 증가한다. 본 논문에서는 사용후 핵연료 저장조 감시카메라의 관측 성능을 평가하기 위해, 고성능 칼라 CCD 카메라에 대해서 1 kGy/h 의 고선량율로 감마선 조사실험을 수행하였다. 이에 대한 실험결과를 기술한다.

Optimum of Gamma Irradiation Dose for Rice-based Infant Foods with Improved Energy-density and Shelf-life (쌀기본 이유식의 에너지 밀도 및 저장성 증대를 위한 최적 감마선 조사 선량)

  • 이유석;오상희;이주운;김장호;김재훈;김관수;김왕근;변명우
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.33 no.5
    • /
    • pp.894-898
    • /
    • 2004
  • This study was carried out to determine the optimum irradiation dose for infant foods with improved energy-density and extend shelf-life using gamma irradiation. Rice and rice porridge were irradiated at 0, 2.5, 5, 7.5, 10, 15 and 20 kGy, and rheological characteristics and total plate count of porridge were evaluated for 6 weeks. Rice and rice porridge at 2.5 kGy dose reduced the viscosity with 22% and 98%, respectively. The result of total aerobic bacteria of non-irradiated rice porridge was 6 log CFU/g and that of 2.5 kGy irradiated rice porridge on 2 weeks storage was 3 log CFU/g, while that of 7.5 kGy irradiated sample was not detected even at the end of storage. Irradiation on rice-based porridge was proper to enhance the total solid in inverse proportion to considering viscosity and extend shelf-life. Gamma irradiation was effective technology in enhancing calorie value of porridge due to reduction of viscosity.

Improvements in Storage Stability of Undaria pinnatifida after Gamma Irradiation (감마선 조사에 의한 미역의 저장성 개선)

  • Kim, Hyun-Joo;Choi, Jong-Il;Kim, Jae-Hun;Chun, Byung-Soo;Ahn, Dong-Hyun;Kim, Gwang-Hoon;Byun, Myung-Woo;Lee, Ju-Woon
    • Food Science and Preservation
    • /
    • v.16 no.4
    • /
    • pp.590-593
    • /
    • 2009
  • The effect of gamma irradiation on the storage stability of Undaria pinnatifida was investigated. A three-log reduction in total aerobic bacteria in U. pinnatifida samples was obtained by irradiation with 3 kGy. During storage for 2 weeks, the viable counts of microorganisms in non-irradiated U. pinnatifida increased to 6 log CFU/g. However, irradiation of U. pinnatifida by 5 kGy eliminated microorganisms. The Hunter $L^{\ast}-value$ of U. pinnatifida was slightly increased after 5 kGy of irradiation. The hardness properties of U. pinnatifida decreased during storage, but were not changed by irradiation with up to 3 kGy. These results indicate that low-dose irradiation (3 kGy) could be effective for improvement of the storage stability of U. pinnatifida.

Changes of Microorganisms and Active Compounds in Glycyrrhizae Radix as Affected by Drying Method and Gamma Ray Treatments (건조 방법 및 감마선 조사에 따른 감초의 미생물 저감효과 및 유효성분 변화)

  • Kim, Joon-Hee;Kang, Byoung-Man;Kim, Jun Yong;Kim, Ryu-Dam;Hwang, Hyun Chul;Lee, Jae-Woong
    • Korean Journal of Plant Resources
    • /
    • v.35 no.4
    • /
    • pp.428-434
    • /
    • 2022
  • Glycyrrhizae Radix is an herbal medicine vulnerable to fungi. So there are regulations on mycotoxins. Therefore, in this study, the affect of various drying methods and additional gamma irradiation (10 kGy) was studied to suppress the microbial generation of Glycyrrhizae Radix. As a result of detecting and comparing microorganisms using the dry film method for samples prepared by each of natural, hot air, freezing, microwave drying and gamma irradiation, the affect of reducing microorganisms by microwave drying and gamma irradiation was confirmed. There was no statistically significant change in the content of the active compounds between the treatment groups.

A Study on the Nuclear Structure through the Multipurpose Coincidence Measurement System Development ( I ) - The Electromagnetic Properties of the Gamma Transitions in $^{75}As$- (다목적 동시측정 장치 개발에 의한 원자핵 구조 연구(I) - $^{75}As$의 감마 전이에 대한 전자기적 특성 -)

  • Chung, Won-Mo;Chung, Kap-Soo;Joo, Koan-Sik;Na, Sang-Kyun;Hwang, Han-Yull
    • Journal of Radiation Protection and Research
    • /
    • v.18 no.1
    • /
    • pp.53-61
    • /
    • 1993
  • The gamma-gamma coincidence measurements and angular correlation measurement associated with the electron capture of $^{75}Se$ have been carried to understand the structure for the odd nuclei $^{75}As$ with two HPGe detectors. As a result, we could determined the band structure of 5/2 state to be of 1/2 [310] band which is based on $f_{5/2}$ proton state. Also we obtained the multipole admixture in the state of 279.5keV by using the mixing ratios of $121.1{\sim}279.5keV$ cascade. Subsequently, it is determined that 25.56% electric quadrupole transition is involved in the state of 279.5keV.

  • PDF

The Study Image Aquisition System for Radiation Source Using the Stereo Gamma-ray Detector (스테레오 감마선 탐지장치를 이용한 감마선원 분포측정 시스템에 관한 연구)

  • Hwang, Young-Gwan;Lee, Nam-Ho;Lee, Seung-Min
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.4
    • /
    • pp.197-203
    • /
    • 2015
  • Nuclear power plant has increased continuously for power production in all over the world and the interest about nuclear accident and the dismantling of aging nuclear power plant has been a growing. The leaked radioactive source that is generated by radiation accidents must detect and remove to minimized the damage as soon as possible. Gamma-ray detection system that have been developed until now cannot provide the precise position of radioactive sources because they detect and imaging the position of radiation sources in just two dimensions. In this paper, stereo gamma ray detection system has developed and the algorithm for calculation of the distance has implemented to be able to measure the distribution of the leakage gamma ray source for the system. Stereo camera calibration for distance detection was conducted with the correction pattern and LED light and we carried out performance test of the system for the LED light source and a gamma ray source. In both experiments the results of the performance test, it was confirmed to have a 5% error. The results of this paper is used as a material for the development of gamma-ray imaging device.