• Title/Summary/Keyword: 감마선 투과율

Search Result 13, Processing Time 0.025 seconds

Calculations of Radiation Measurement-Related Correction Factors (방사선 측정관련 보정인자 계산)

  • Shin, Hee-Sung;Ro, Seung-Gy;Kim, Ho-Dong
    • Journal of Radiation Protection and Research
    • /
    • v.28 no.1
    • /
    • pp.19-24
    • /
    • 2003
  • The self-attenuation factor for an $^{198}Au$ sample and the 0.412 MeV gamma-ray penetration ratio in the circular Al-cover of the radiation detector have been determined using an analytical solution and MCNP code. The results show that the self-attenuation factors obtained from the analytical solution coincide with those of MCNP code for all but the Au sample with the relatively larger radius. Then the maximum difference between the two methods appears to be 9 % in the Au sample of 1.5 mm radius. It also is revealed that the analytical solutions of the 0.412 MeV gamma-ray penetration ratio in the Al-cover of 7.62 cm radius are consistent with those of the MCNP code within the standard deviation.

Comparison of Weight Functions in Iterative Technique for Image Reconstruction of Gamma-ray CT (감마 CT 영상재구성을 위한 반복적인 방법의 가중치 함수비교)

  • Lee, Na-Young;Jung, Sung-Hee;Kim, Jong-Bum;Kim, Jin-Sup;Kim, Jae-Ho
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2007.10c
    • /
    • pp.480-484
    • /
    • 2007
  • 일반적으로 x선 CT는 물체 투과율이 짧기 때문에 대형 산업공정 내부의 영상진단 시 대상체는 금속으로 구성되어 있으며 내부는 액체, 고체, 기체 등 고밀도 물질이 포함되어 있어 계측이 어렵다. 따라서 본 논문에서는 물체 투과율이 x선에 비해 긴 감마선을 사용하였다. 대형 산업공정 내부의 단면영상을 재구성하기 위하여 반복적인 영상재구성 방법의 가중치 함수를 비교하였다. 실험 결과를 통하여 감마 CT 영상에서 빔 통과 여부에 따른 가중치 함수보다 빔 길이나 면적에 의한 가중치 함수로 복원할 경우, 원 영상과 유사함을 확인하였다.

  • PDF

옥수수 전분 추출공정 및 물성개선을 위한 방사선의 이용연구

  • 강일준;이수정
    • Proceedings of the Korean Society of Postharvest Science and Technology of Agricultural Products Conference
    • /
    • 1994.07a
    • /
    • pp.15-16
    • /
    • 1994
  • 옥수수 전분의 추출공정 개선 연구의 일환으로 메 밀 찰옥수수에 0-10 kGy범위의 감마선을 조사한 후 전분 추출시험과 추출전분의 이화학적 특성을 펴가하였다. 적정선량 범위의 감마선조사는 전분추출을 위한 침지시간을 기존 50시간에서 40시간으로 단축 시킬 수 있었으며, 환경기준 물질인 옥수수침지액(아황산용액)의 농도를 기존 0.8-1.2% 에서 0.2%로 크게 감소시킬 수 있었다. 또한 옥수수전분 추출액에 있어서 감마선 조사된 메옥수수와 찰옥수수는 비조사군에 비해 10-30% 이상의 추출율 증대효과를 나타내었다. 추 전분의 이화학적 특성시험에있어서는 두 시료 모두 감마선조사에 의해 alkaili number와 광투과도가 크게 증가 하였으며, 물 결합능력 및 swelling power는 다소 감소하는 경향이었다.전분의 색도는 조사군과 비조사군 사이에 유의적인 차이가 없었다. 효소반응 시험에서는 감마선 조사량이 증가함에 따라 효소반응 생성물인 포도당과 환원당 함량이 크게 증가하였다. Amylograph에 의한 물성시험에서는 감마선조사에 의해 전분호화액의 점도는 감소되었고, 그 경향은 메옥수수보다 찰옥수수에서 더욱 현저하였다. 또한 감마선의 이용은 옥수수 전분의 breakdown ratio 및 setback ratio를 향상시킬 수 있어 식품가공에서 전분의 고존도 사입 가능성을 시사하였다. 시사하였다.

  • PDF

A study on the measurement of void fraction using gamma ray (감마선을 이용한 기포율측정에 관한 연구)

  • Nam, Pyong-Woo
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.9 no.1
    • /
    • pp.13-23
    • /
    • 1980
  • sing the physical characteristics of nuclear radiation penerated into the cross section of the measurement of void fraction in saturated vapor & water passing through the is analyzed theoretically and the solutions are achieved by means of computer simulation. These theoretical results are also approved through the experiment with the simulators.

  • PDF

Development of nuclear measurement system for gamma column scanning (증류탑 진단을 위한 방사선 응용계측기 개발)

  • Kim, Jong-Bum;Jung, Sung-Hee;Jin, Jun-Ha;Jun, Jong-Kuj
    • Proceedings of the KIEE Conference
    • /
    • 2004.07d
    • /
    • pp.2619-2621
    • /
    • 2004
  • 감마선 또는 x-선 등 방사선을 이용한 구조물 진단은 산업전반에 걸쳐 널리 이용되고 있다. 기존의 x-선이나 Ir-192의 감마선 등을 이용한 비파괴검사는 용접부의 확인이나 구조물의 내부 결점 확인과 같이 국부적인 진단에는 유용하나 석유화학산업에서 반응물의 분리 또는 정제 등에 많이 사용되고 있는 증류탑의 내부진단 실험에는 적합하지 않다. 증류탑은 목적에 따라 직경이 $3{\sim}10m$, 높이 $10{\sim}100m$에 달하는 대형 장치로서 내부의 이상현상에 대한 정확한 진단은 공정 전체의 가동효율 최적화에 결정적인 영향을 끼친다. 밀봉 감마선원으로부터 방출된 방사선의 투과율 변화를 증류탑의 반대편에 설치한 방사선 검출기로 측정하여 수직밀도분포(vertical density profile)를 구하여 증류탑의 내부현상에 대한 정확한 정보를 얻을 수 있는데 이러한 작업을 자동으로 수행할 수 있도록 한 것이 자동 증류탑 검사장치이다. 증류탑 진단장치는 크게 방사선 계측 및 데이터 전송회로, 방사선원부와 방사선검출부의 구동장치 및 구동회로, 데이터 수집 및 제어장치 둥으로 구성되어 있으며, 증류탑 검사를 자동화하여 진단결과의 신뢰도와 재현성을 향상시켰다. 본 논문은 방사선원과 방사선 검출장치의 위치를 자동으로 제어하면서 방사선 계측결과를 전송시키는 장치의 개발에 관한 내용으로서 개발된 장치의 소개와 산업현장 적용의 예를 소개함으로써 기존의 비파괴검사기술로는 진단할 수 없는 대형 증류탑의 진단에 효과적인 방사선 응용 계측장치임을 보이고자 한다.

  • PDF

Shielding Effectiveness of Magnetite Heavy Concrete on Cobalt-60 Gamma-rays

  • Lim, Yong-Kyu
    • Nuclear Engineering and Technology
    • /
    • v.3 no.2
    • /
    • pp.65-75
    • /
    • 1971
  • The gamma-ray shielding effects of magnetite concretes have been measured using a broad beam Co-60 gamma-ray source. Mathematical formulae for a trans-mission ratio-to-shield thickness relation were derived from the attenuation curve obtained experimentally and are I (x) = I (ο) exp(-$\mu$X) exp(1.03$\times$10$^{-1}$ X-3.38$\times$10$^{-3}$ X$^2$+5.29$\times$10$^{-5}$ X$^3$) when X< 20 cm, I (x) =I (ο) exp(-$\mu$X) exp(4.66$\times$10$^{-2}$ X+2.12$\times$10$^{-1}$ ) when X>20 cm. Here I (x) is radiation intensity after passing through a thickness X of absorber, I(o) is the initial radiation intensity, $\mu$ is the linear attenuation coefficient of magnetite concrete and is given by (0.0532$\rho$+ 0.0083)$^{4)}$ $cm^{-1}$ / in accordance with an earlier study, and X is the thickness of absorber. In addition, a model shield which is a rectangular magnetite concrete box with walls of 8cm thickness walls and internal demensions of 40$\times$40$\times$40 cm was constructed and its shielding effect has been measured. The emergent radiation flux appears to be greater with this configuration than with a slab shield of equal thickness.

  • PDF

Transmission Dose Measurement of Gamma-ray Using Tungsten Shield (텅스텐 차폐체의 감마선 투과선량 측정)

  • Han, Sang-Hyun;Koo, Bon-Yeoul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.9
    • /
    • pp.124-129
    • /
    • 2018
  • This study was conducted to investigate the penetration dose and shielding rates of tungsten shields used in apron material by changing the type of source used in the nuclear medicine department, thickness of shielding material and distance between the source and detector. For the experiment, the source, shield, and detector were arranged in a straight line and measured with an inspector at a height of 100 cm. The highest shielding effect of tungsten was measured for $^{201}Tl$, while $^{123}I$ showed a higher shielding effect than $^{99m}Tc$. For the sources used in the experiment, the penetration dose decreased with distance and the shielding rate was measured with thicker thickness. However, the shielding rate of $^{13}1I$ and $^{18}F$ sources was found to be lower than when there was no shielding at 0.25 mmPb shield. Therefore, even if the radiation shielding effect of tungsten is high, considering the characteristics according to the type of source and the thickness of the shielding material, it may be helpful to reduce the exposure.

방사선치료빔 실시간 측정장치 개발

  • Kim, Jae-Hong;Swanepoe, M.W.;deKock, E.A.;Park, Yeon-Su;Yang, Tae-Geon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.288-288
    • /
    • 2010
  • 현대사회의 급속한 고령화로 암 환자의 수는 2002년 기준 약 10만 명에서 매년 7~10 %씩 증가되어 2012년에는 20만 명이 될 것으로 추정되어지고 있다. 수술, 방사선 치료, 약물요법 등이 주요 치료방법이며, 암 환자의 30-50 %가 전리 방사선치료를 받고 있다. 방사선치료는 19세기 말에 발견된 미지의 X-선이 희망의 방사선으로 변화하여 암의 진단 및 치료에 활용되고 있으며, 인간 삶의 질 향상에 핵심적인 역할을 담당하고 있다. 기존의 X-선이나 감마선의 단점을 극복 할 수 있는 입자 빔을 1970년대 미국의 캘리포니아 대학 Berkely National Laboratory에서 처음으로 암 치료에 적용하였다. 현재는 일본과 독일에서 활발하게 활용되고 있으며 국내에서도 입자 치료시설을 구축 또는 개발계획 중에 있다. 방사선치료의 완치율을 높이기 위해서는 정확한 선량을 암세포에 전달해야 한다. 환자에 전달되는 입자빔을 실시간으로 측정하는 기술이 연구되어지고 있다. 지금까지는 빔의 특성을 측정하기 위해 간섭적인 방법을 사용하였으나, 투과형 검출기를 개발하여 실시간으로 치료와 빔 특성을 동시에 수행하는 기술개발연구가 보고되고 있다. 본 연구에서는 Multileaf Faraday Cup (MLPC) 검출기 설계구조와 데이터 측정방법에 관한 연구를 수행하고자 한다. 빔의 전송 방향으로 3개층의 $4{\times}4$ 배열의 구조로 48 channel의 전류값을 측정하여 입자빔의 분포를 실시간으로 관측하고, 측정된 전류는 ADC를 거쳐 치료계획에 의해 선택된 영역의 SOBP를 유지하도록 range modulation propeller를 조절하는 feed-back system을 갖춘 방사선치료빔 실시간 측정장치 개발에 관한 결과를 보고하고자 한다.

  • PDF

Effects of Low Dose Gamma-irradiation on Alleviation of Salt Stress in Rice (Oryza sativa L.) Seedling (저선량 감마선 조사가 벼 유묘의 염 스트레스 경감에 미치는 영향)

  • Baek, Myung-Hwa;Kim, Jin-Hong;Wi, Seung-Gon;Lee, In-Jung;Lee, Kyu-Seong;Kim, Jae-Sung
    • Korean Journal of Environmental Agriculture
    • /
    • v.24 no.2
    • /
    • pp.153-158
    • /
    • 2005
  • To investigate alleviation effects of salt stress by low dose gamma-irradiation on seedling growth of rice (Oryza shrive L), in plants of two rice cultivars (Ilpumbyeo and Gancheokbyeo), seeds were irradiated with the different doses $(0{\sim}32\;Gy)$ of gamma-ray by irradiator ($^{60}Co$, ca.150 TBq of capacity, AECL). The salt stress caused a remarkable decrease of seedling growth, particularly for dry weight. In addition, relative growth rate was decreased over 50% by the salt stress. However, the salt stress-induced inhibition of growth was alleviated by gamma-irradiation. Especially, the relative growth rate of shoot showed the reduction effect over 30% at 4 Gy-irradiated groups as compared with that of control. Also, electrolyte leakage and relative water content were damaged, respectively 4 times and 30% by the salt stress but the damages were alleviated by the gamma-irradiation. These alleviation effects were observed similarly in both the cultivars tested. These results suggest that the low dose gamma-irradiation may have a better protection or the salt stress.

A Study of Gamma-ray Irradiation Effects on Commercially Available Single-mode Optical Fiber (국내외 상용 단일모드 광섬유의 감마선 영향 분석 연구)

  • Kim, Jong-Yeol;Lee, Nam-Ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.05a
    • /
    • pp.564-567
    • /
    • 2012
  • Optical fibers are going to be used for telecommunication, image fibers, sensors under irradiation in nuclear power plants and various irradiation facilities. Especially, Temperature detection sensors using Raman light scattering, temperature or strain sensors using fiber gratings, magnet-optical sensors using photo-magnetic effect, are already commercialized. However, When fibers are exposed to ionizing radiation, color centers are formed in fibers which reduces their light transmission, and it is limited in applying under radiation environments. In this study, $Co^{60}$ gamma-ray induced optical attenuation on Ge-doped single mode(SM) fiber has been measured. Gamma-ray is irradiated for 4hours at the dose rate of 0.5kGy/hr, 2kGy/hr, 8kGy/hr. Consequently, gamma-ray induced loss based on radiation effects in Ge-doped SM fiber occur precisely. Furthermore, dose rate effect that the higher dose rate in the same total dose, the more increase loss of optical fiber and annealing effect that the higher the loss after irradiation, the more increase the recovery rate of the loss are observed in the fiber. This results plan to make use of bases in the study of the radiation-hardened optical fiber.

  • PDF