• Title/Summary/Keyword: 감마분광

Search Result 101, Processing Time 0.046 seconds

A Study on the Natural Uranium Contamination Measuring Technology (천연우라늄 오염에 관한 방사선/능 측정기술 연구)

  • 정운수;홍상범;서범경;박진호;조용우;조성원;이정민
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2004.06a
    • /
    • pp.407-417
    • /
    • 2004
  • This study is to verify radiation detection method by using $\alpha$-spectroscopy and ${\gamma}$-spectroscopy for concretes and components which will be generated during the decommissioning of the uranium conversion plant. Components and inside walls of the building were contaminated with natural uranium materials. Some parts of the stainless steel pipes and concretes of the walls were sampled and analyzed their alpha and gamma activities respectively. Alpha and gamma activities are well matched each other in the range of high activity region to 0.01 Bq/g and gamma activities are over estimated comparing alpha activities corresponded in below 0.005 Bq/g region for the natural uranium of AUC sample. The $^{238}U$ originated from natural products of conversion process could be distinguished by measuring $^{214}Pb$ or $^{214}Bi$ and $^{234}Th$ or $^{234m}Pa$. Uranium contaminations mainly are in the wall surface of the plant. Decontamination process of generating wastes which can be reached tp background level gamma activities measured by gamma spectroscopy can also be used to conservative assessment data.

  • PDF

감마선 동위원소 핵종비를 이용한 PWR 사용후핵연료의 연소도 결정

  • 박형종;박대규;박광준;서기석;엄성호;민덕기;노성기
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05b
    • /
    • pp.509-514
    • /
    • 1998
  • ORIGEN-S 전산코드로 계산된 가압경수로(PWR)사용후핵연료 내에 존재하는 방사성핵종비 $^{134}$ Cs/$^{137}$Cs 및 $^{154}$ Eu/$^{137}$Cs 를 감마선 분광실험으로 측정한 값과 비교하여 핵연료의 연소도를 결정하였다. 고리 1호기 및 2호기 사용후핵연료봉에 대한 감마선 분광실험을 한국원자력연구소 조사재시험시설(IMEF)과 조사후시험시설(PIEF)의 시험기기 및 장치를 이용하여 수행하고 이 결과로부터 $^{134}$ Cs/$^{137}$Cs 와 $^{154}$ Eu/$^{137}$Cs 의 핵종비를 측정하였다. 이와 별도로 사용후핵연료의 연소도, 냉각시간, 초기농축도등에 따른 $^{134}$ Cs/$^{137}$Cs 와 $^{154}$ Eu/$^{137}$Cs의 핵종비를 ORIGEN-S 코드로 계산을 하였으며, 이 핵종비와 연소도 사이의 관계를 회귀분석하여 2차 다항식 함수로 유도하였다 이관계식과 감마선 분광실험으로 측정한 $^{134}$ Cs/$^{137}$Cs와 $^{154}$ Eu/$^{137}$Cs 의 핵종비를 이용하여 각각의 연소도를 결정할 수 있었다.

  • PDF

Development of a simple laboratory-made radioactive source to check the integrity of a gamma spectrometry system with HPGe detector (HPGe 검출기를 사용한 감마분광분석계의 점검선원 개발)

  • Lee, Mo Sung
    • Journal of Radiation Protection and Research
    • /
    • v.38 no.2
    • /
    • pp.119-123
    • /
    • 2013
  • A simple laboratory-made radioactive source to check the integrity of a gamma spectrometry system with HPGe detector was developed. The check source consists of radium-riched soil which was ground in size of less than 0.154mm and contained in air tight cylinderical vial, and provides photons with 12 distinct energies. The spectra of the check source were measured once a month during one year, analyzed the charactreictics of their peaks. When the gamma spectrometry system was in normal state, the areas and FWHMs of the gamma rays with more than 3% gamma emission rate in radium and its decay products was constant within standard deviation 2% and 3%, respectively, except 77 keV peak. And it was found that this check source can play a sufficient role to check the integrity of a gamma spectrometry system using 10 peaks in the range of 77 to 2202 keV.

Development of One-channel Gamma ray spectroscope for Automatic Radiopharmaceutical Synthesis System (방사성 의약품 자동합성장치용 단채널 감마선 분광기 보드의 설계 및 제작)

  • Song, Kwanhoon;Kim, Kwangsoo
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.4
    • /
    • pp.193-200
    • /
    • 2014
  • In this paper, the prototype of one-channel gamma-ray spectroscope for automatic radiopharmaceutical systhesis system was designed and characterized. The prototype employed CZT (CdZnTe) spear detector for gamma-ray detection and employed analog-type signal processing method. A radioactive sample Co-60 was used for measuring performance of the gamma-ray spectroscope and energy spectrum is gained with bandwidth of 1173keV. The analog board is made up of SF (shaping filter) and PHA (peak and hold amplifier) for shaping CZT output signal appropriately and ADC (analog to digital converter) and FPGA (field programmable gate array) for drawing gamma-ray spectrum by counting the digitalized gamma-ray signal data.

Shielding Design Optimization of the HANARO Cold Neutron Triple-Axis Spectrometer and Radiation Dose Measurement (냉중성자 삼축분광장치의 차폐능 최적화 설계 및 선량 측정)

  • Ryu, Ji Myung;Hong, Kwang Pyo;Park, J.M. Sungil;Choi, Young Hyeon;Lee, Kye Hong
    • Journal of Radiation Protection and Research
    • /
    • v.39 no.1
    • /
    • pp.21-29
    • /
    • 2014
  • A new cold neutron triple-axis spectrometer (Cold-TAS) was recently constructed at the 30 MWth research reactor, HANARO. The spectrometer, which is composed of neutron optical components and radiation shield, required a redesign of the segmented monochromator shield due to the lack of adequate support of its weight. To shed some weight, lowering the height of the segmented shield was suggested while adding more radiation shield to the top cover of the monochromator chamber. To investigate the radiological effect of such change, we performed MCNPX simulations of a few different configurations of the Cold-TAS monochromator shield and obtained neutron and photon intensities at 5 reference points just outside the shield. Reducing the 35% of the height of the segmented shield and locating lead 10 cm from the bottom of the top cover made of polyethylene was shown to perform just as well as the original configuration as radiation shield excepting gamma flux at two points. Using gamma map by MCNPX, it was checked that is distribution of gamma. Increased flux had direction to the top and it had longer distance from top of segmented shield. However, because of reducing the 35% of the height, height of dissipated gamma was lower than original geometry. Reducing the 35% of the height of the segmented shield and locating lead 10cm from the bottom of the top cover was selected. After changing geometry, radiation dose was measured by TLD for confirming tester's safety at any condition. Neutron(0.21 ${\mu}Svhr^{-1}$) and gamma(3.69 ${\mu}Svhr^{-1}$) radiation dose were satisfied standard(6.25 ${\mu}Svhr^{-1}$).

Uranium Activity Analysis of Soil Sample Using HPGe Gamma Spectrometer (고순도 반도체(HPGe) 감마분광시스템을 이용한 토양 중 우라늄 방사능 분석)

  • Lee, Wan-No;Kim, Hee-Reyoung;Chung, Kun-Ho;Cho, Young-Hyun;Kang, Mun-Ja;Lee, Chang-Woo;Choi, Geun-Sik
    • Journal of Radiation Protection and Research
    • /
    • v.35 no.3
    • /
    • pp.105-110
    • /
    • 2010
  • Using N-type HPGe gamma spectrometer, uranium analysis technique of soil sample is developed where the chemical preprocessing is not a necessity. The results of uranium activities using the method presented in this paper were compared with those results with conventional alpha spectrometer and two results were similar from within uncertainty range. Therefore, this new method will be applied in uranium activity analysis of soil sample.

Gamma-Ray Spectrometric Determination of Burnup Distribution and Cooling Time of Spent PWR Fuel Assemblies (감마선 분광분석에 의한 조사후 핵연료 집합체(PWR)의 연소분포 및 냉각시간 결정)

  • Young-Gil Lee;Jae-Shik Jun
    • Nuclear Engineering and Technology
    • /
    • v.17 no.1
    • /
    • pp.1-7
    • /
    • 1985
  • Non-destructive gamma-ray spectrometry was carried out on the spent PWR fuel assemblies at the spent fuel pool of reactor-site. Attention was focused on the determination of burnup distribution and cooling time. For the measurement of burnup distribution, the concentration ratio of $^{134}$ Cs$^{137}$ Cs was used and the results showed these ratios varied with the positions of assemblies in the core during their irradiation. For the measurement of cooling time, $^{144}$ Ce$^{137}$ Cs was used and the results were agreed considerably well with the operator declared cooling time.

  • PDF

Spectroscopic Properties of a Silicon Photomultiplier-based Ce:GAGG Scintillation Detector and Its Applicability for γ-ray Spectroscopy (감마선 분광분석을 위한 실리콘 광 증배소자 기반 Ce:GAGG 섬광검출기의 분광특성 연구)

  • Park, Hye Min;Kim, Jeong Ho;Kim, Dong Seong;Joo, Koan Sik
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.2
    • /
    • pp.73-78
    • /
    • 2015
  • In this study, a scintillation detector was fabricated using a silicon photomultiplier (SiPM) and a Ce:GAGG scintillator single crystal, and its spectroscopic properties were compared with those of commercially available LYSO and CsI:Tl scintillators using ${\gamma}$-ray spectroscopy. The energy resolutions of the self-produced scintillation detector composed of the scintillator single crystal (volume: $3{\times}3{\times}20mm^3$) and SiPM (Photosensitive area: $3{\times}3mm^2$) for standard ${\gamma}$-ray sources, such as $^{133}Ba$, $^{22}Na$, $^{137}Cs$ and $^{60}Co$ were measured and compared. As a result, the energy resolutions of the proposed Ce:GAGG scintillation detector for g-rays, as measured using its spectroscopic properties, were found to be 13.5% for $^{133}Ba$ 0.356 MeV, 6.9% for $^{22}Na$ 0.511 MeV, 5.8% for $^{137}Cs$ 0.662 MeV and 2.3% for $^{60}Co$ 1.33 MeV.

Feasibility about the Direct Measurement of 226Ra Using the Gamma-Ray Spectrometry (감마분광분석을 이용한 226Ra의 직접 측정방법에 대한 적용성 평가)

  • Ji, Young-Yong;Chung, Kun Ho;Lim, Jong-Myoung;Kim, Change-Jong;Jang, Mee;Kang, Mun Ja;Park, Sang Tae;Woo, Zuhee;Koo, Boncheol;Seo, Bokyun
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.12 no.2
    • /
    • pp.97-105
    • /
    • 2014
  • In the case of the direct measurement of $^{226}Ra$ using a HPGe gamma-ray spectrometer, the interference between gammarays with 186.21 keV of $^{226}Ra$ and 185.7 keV of $^{235}U$ should be corrected to calculate the net peak area in the energy spectrum. In general, it is very difficult to conduct peaks stripping with difference of about 0.5 keV, although a HPGe with the superior resolution is applied and the maximum channels is applied to the spectrometer. In this study, several interference correction techniques in the direct measurement were surveyed to evaluate the feasibility for the measurement of $^{226}Ra$ using the gamma-ray spectrometery. Applying the interference corrections to the analysis of raw materials and by-products, the method validation for the direct measurement of $^{226}Ra$ was conducted by evaluating the measurement uncertainty, linearity, and range. As a result, the optimum method of the interference correction was selected by comparing with the indirect measurement of which progenies of $^{226}Ra$, such as $^{214}Pb$ and $^{214}Bi$, were analyzed in the secular equilibrium state.