• 제목/요약/키워드: 감마변환

검색결과 69건 처리시간 0.027초

The Spin Reorientations in $\alpha-Fe_2O_3$ Thin Film ($\alpha-Fe_2O_3$ 박막에서 스핀 재 정렬에 관한 연구)

  • 서정철;이호선
    • Journal of the Korean Magnetics Society
    • /
    • 제11권1호
    • /
    • pp.21-25
    • /
    • 2001
  • $\alpha$-Fe$_2$O$_3$ thin films were prepared on Si substrate by a pulsed laser deposition system and characterized by X-ray and Mossbauer spectroscopy. The appropriate conditions of pulsation was the power of 5.128 W/cm2 at on oxygen pressure of 0.1 Torr at a substrate temperature of 30$0^{\circ}C$. After that the film was heated at 80$0^{\circ}C$ for 1 day. The particles shape deposited on the film was ellipsoidal and the average length and width were 200~300 nm, 70~150 am respectively. The crystal structure was conformed to be of corundums symmetry with the hexagonal unit cell having a lattice constant of u = 5.03$\pm$0.05 $\AA$, c = 13.735$\pm$0.05 $\AA$. The average angles between the atomic spin and the magnetic hyperfine field of Fe ion were 38$^{\circ}$and 48$^{\circ}$ at above and blow the Morin transition temperature respectively. The Morin transition was found to occur at the temperature ranges from 200 K to room temperature and atomic spin direction was assumed to change from 48$^{\circ}$ to 80$^{\circ}$in respect to the c-axis.

  • PDF

Efficacy and Accuracy of Patient Specific Customize Bolus Using a 3-Dimensional Printer for Electron Beam Therapy (전자선 빔 치료 시 삼차원프린터를 이용하여 제작한 환자맞춤형 볼루스의 유용성 및 선량 정확도 평가)

  • Choi, Woo Keun;Chun, Jun Chul;Ju, Sang Gyu;Min, Byung Jun;Park, Su Yeon;Nam, Hee Rim;Hong, Chae-Seon;Kim, MinKyu;Koo, Bum Yong;Lim, Do Hoon
    • Progress in Medical Physics
    • /
    • 제27권2호
    • /
    • pp.64-71
    • /
    • 2016
  • We develop a manufacture procedure for the production of a patient specific customized bolus (PSCB) using a 3D printer (3DP). The dosimetric accuracy of the 3D-PSCB is evaluated for electron beam therapy. In order to cover the required planning target volume (PTV), we select the proper electron beam energy and the field size through initial dose calculation using a treatment planning system. The PSCB is delineated based on the initial dose distribution. The dose calculation is repeated after applying the PSCB. We iteratively fine-tune the PSCB shape until the plan quality is sufficient to meet the required clinical criteria. Then the contour data of the PSCB is transferred to an in-house conversion software through the DICOMRT protocol. This contour data is converted into the 3DP data format, STereoLithography data format and then printed using a 3DP. Two virtual patients, having concave and convex shapes, were generated with a virtual PTV and an organ at risk (OAR). Then, two corresponding electron treatment plans with and without a PSCB were generated to evaluate the dosimetric effect of the PSCB. The dosimetric characteristics and dose volume histograms for the PTV and OAR are compared in both plans. Film dosimetry is performed to verify the dosimetric accuracy of the 3D-PSCB. The calculated planar dose distribution is compared to that measured using film dosimetry taken from the beam central axis. We compare the percent depth dose curve and gamma analysis (the dose difference is 3%, and the distance to agreement is 3 mm) results. No significant difference in the PTV dose is observed in the plan with the PSCB compared to that without the PSCB. The maximum, minimum, and mean doses of the OAR in the plan with the PSCB were significantly reduced by 9.7%, 36.6%, and 28.3%, respectively, compared to those in the plan without the PSCB. By applying the PSCB, the OAR volumes receiving 90% and 80% of the prescribed dose were reduced from $14.40cm^3$ to $0.1cm^3$ and from $42.6cm^3$ to $3.7cm^3$, respectively, in comparison to that without using the PSCB. The gamma pass rates of the concave and convex plans were 95% and 98%, respectively. A new procedure of the fabrication of a PSCB is developed using a 3DP. We confirm the usefulness and dosimetric accuracy of the 3D-PSCB for the clinical use. Thus, rapidly advancing 3DP technology is able to ease and expand clinical implementation of the PSCB.

Color Image Enhancement Based on an Improved Image Formation Model (개선된 영상 생성 모델에 기반한 칼라 영상 향상)

  • Choi, Doo-Hyun;Jang, Ick-Hoon;Kim, Nam-Chul
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • 제43권6호
    • /
    • pp.65-84
    • /
    • 2006
  • In this paper, we present an improved image formation model and propose a color image enhancement based on the model. In the presented image formation model, an input image is represented as a product of global illumination, local illumination, and reflectance. In the proposed color image enhancement, an input RGB color image is converted into an HSV color image. Under the assumption of white-light illumination, the H and S component images are remained as they are and the V component image only is enhanced based on the image formation model. The global illumination is estimated by applying a linear LPF with wide support region to the input V component image and the local illumination by applying a JND (just noticeable difference)-based nonlinear LPF with narrow support region to the processed image, where the estimated global illumination is eliminated from the input V component image. The reflectance is estimated by dividing the input V component image by the estimated global and local illuminations. After performing the gamma correction on the three estimated components, the output V component image is obtained from their product. Histogram modeling is next executed such that the final output V component image is obtained. Finally an output RGB color image is obtained from the H and S component images of the input color image and the final output V component image. Experimental results for the test image DB built with color images downloaded from NASA homepage and MPEG-7 CCD color images show that the proposed method gives output color images of very well-increased global and local contrast without halo effect and color shift.

High Energy Photon Dosimetry by ESR Spectroscopy in Radiotherapy (ESR Spectroscopy에 의한 치료용 고에너지 광자선의 선량측정)

  • Chu, Sung-Sil
    • Progress in Medical Physics
    • /
    • 제1권1호
    • /
    • pp.31-42
    • /
    • 1990
  • The finding of long lived free radicals produced by ionizing radiation in organic crystals and the quantification of this effect by electron spin resonance(ESR) spactroscopy has proven excellent dosimetric applicability. The tissue equivalent alanine dosimeter also appear appropriate for radiation therapy level dosimetry. The dose measurement was performed in a Rando phantom using high energy photons as produced by high energy medical linear accelerator and cobalt-60 teletherapy unit. The absorbed dose range of the ESR/alanine dosimetry system could be extended down to 0.1 Gy. The response of the alanine dosimeters was determined for photons at different therapeutic dose levels from less than 0.1 Gy to 100 Gy and the depth dose measurements were carried out for photon energies of 1.25MeV, 6 and 10 MV with alanine dosimeters in Rando phantom. Comparisons between ESR/alanine in a Rando phantom and ion chamber in a water phantom were made performing depth dose measurements to examine the agreement of both methods under field conditions.

  • PDF

Oral Toxicity Study on the 90-day Repeated-dose of 50 kGy Irradiated Methanol Extract Powder of Red Ginseng (50 kGy 감마선 조사된 홍삼 메탄올 추출물의 90일 반복 투여 독성시험)

  • Jeon, Young-Eun;Kim, Jin-Kyung;Yin, Xing-Fu;Lee, Ju-Woon;Nam, Jin-Sik;Kang, Il-Jun
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • 제40권6호
    • /
    • pp.824-831
    • /
    • 2011
  • This study was to investigate 90-day repeated-dose toxicities of 50 kGy irradiated methanol extract powder of red ginseng in ICR mice. The test materials (methanol extract powder of red ginseng with or without 50 kGy irradiation) were administered by gavage to male and female ICR mice at dose levels of 0, 125, 250 and 500 mg/kg/day for 90 days. In the results, no abnormality was observed in mortality, clinical findings, body weight changes, food consumptions, opthalmoscopic findings, necropsy findings and histopathological findings. Although the minor changes in blood and biochemical parameters were observed, they were not dose dependent and not affected by gamma irradiation. In conclusion, 90-day repeated oral dose of the methanol extract powder of red ginseng and 50 kGy irradiated methanol extract powder of red ginseng to ICR mice did not cause apparent toxicological change at the dose of 125, 250 and 500 mg/kg body weight.

The efficiency Analysis of study using brainwave measurement device (Biopac 뇌파측정 장치를 이용한 학습의 효율성 분석)

  • An, Young-Jun;Lee, Chung-Heon;Park, Mun-Kyu;Ji, Hoon;Lee, Dong-Hoon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 한국정보통신학회 2015년도 춘계학술대회
    • /
    • pp.951-953
    • /
    • 2015
  • Learning for thinking says the behavior of the organism changes as a result of practice or experience. It is very difficult to identify focusing ability objectively when students study. But, brain of the body is not so. EEG signal means continuously electric records of brain potential variation between two points on the scalp when brain activities take place. In types of EEG, there are delta(0~4Hz), theta(4~8Hz), alpha(8~13Hz), beta(13~30Hz) and gamma waves(30~50Hz). SMR waves and Mid-beta waves appear when focused for studying. Part for the most influence on concentrating reported that Mid-beta waves. In relation to brain activities, EEG has been actively researched for evaluating brain focus index system during learning and study. So, By using Biopac system for this study, measured brain wave was converted into FFT for extracting Mid-beta domain signals that are related to learning after giving focus invoked subjects to a small number of people. When concentrating, we measured the change in the power of the Mid-beta frequency domain and presented a correlation. Based on these results, we analyzed whether students are concentrated objectively on learning or not. and hope to offer more efficient learning method.

  • PDF

Development of Signal Processing Circuit for Side-absorber of Dual-mode Compton Camera (이중 모드 컴프턴 카메라의 측면 흡수부 제작을 위한 신호처리회로 개발)

  • Seo, Hee;Park, Jin-Hyung;Park, Jong-Hoon;Kim, Young-Su;Kim, Chan-Hyeong;Lee, Ju-Hahn;Lee, Chun-Sik
    • Journal of Radiation Protection and Research
    • /
    • 제37권1호
    • /
    • pp.16-24
    • /
    • 2012
  • In the present study, a gamma-ray detector and associated signal processing circuit was developed for a side-absorber of a dual-mode Compton camera. The gamma-ray detector was made by optically coupling a CsI(Tl) scintillation crystal to a silicon photodiode. The developed signal processing circuit consists of two parts, i.e., the slow part for energy measurement and the fast part for timing measurement. In the fast part, there are three components: (1) fast shaper, (2) leading-edge discriminator, and (3) TTL-to-NIM logic converter. AC coupling configuration between the detector and front-end electronics (FEE) was used. Because the noise properties of FEE can significantly affect the overall performance of the detection system, some design criteria were presented. The performance of the developed system was evaluated in terms of energy and timing resolutions. The evaluated energy resolution was 12.0% and 15.6% FWHM for 662 and 511 keV peaks, respectively. The evaluated timing resolution was 59.0 ns. In the conclusion, the methods to improve the performance were discussed because the developed gamma-ray detection system showed the performance that could be applicable but not satisfactory in Compton camera application.

Color Image Rendering using A Modified Image Formation Model (변형된 영상 생성 모델을 이용한 칼라 영상 보정)

  • Choi, Ho-Hyoung;Yun, Byoung-Ju
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • 제48권1호
    • /
    • pp.71-79
    • /
    • 2011
  • The objective of the imaging pipeline is to transform the original scene into a display image that appear similar, Generally, gamma adjustment or histogram-based method is modified to improve the contrast and detail. However, this is insufficient as the intensity and the chromaticity of illumination vary with geometric position. Thus, MSR (Multi-Scale Retinex) has been proposed. the MSR is based on a channel-independent logarithm, and it is dependent on the scale of the Gaussian filter, which varies according to input image. Therefore, after correcting the color, image quality degradations, such as halo, graying-out, and dominated color, may occur. Accordingly, this paper presents a novel color correction method using a modified image formation model in which the image is divided into three components such as global illumination, local illumination, and reflectance. The global illumination is obtained through Gaussian filtering of the original image, and the local illumination is estimated by using JND-based adaptive filter. Thereafter, the reflectance is estimated by dividing the original image by the estimated global and the local illumination to remove the influence of the illumination effects. The output image is obtained based on sRGB color representation. The experiment results show that the proposed method yields better performance of color correction over the conventional methods.

Qualitative Evaluation of 2D Dosimetry System for Helical Tomotherapy (2차원 토모테라피 선량측정시스템의 정성적 평가)

  • Ma, Sun Young;Jeung, Tae Sig;Shim, Jang Bo;Lim, Sangwook
    • Progress in Medical Physics
    • /
    • 제25권4호
    • /
    • pp.193-198
    • /
    • 2014
  • The purpose of this study is to see the feasibility of the newly developed 2D dosimetry system using phosphor screen for helical tomotherapy. The cylindrical water phantom was fabricated with phosphor screen to emit the visible light during irradiation. There are three types of virtual target, one is one spot target, another is C-shaped target, and the other is multiple targets. Each target was planned to be treated at 10 Gy by treatment planning system (TPS) of tomotherapy. The cylindrical phantom was placed on the tomotherapy table and irradiated as calculations of the TPS. Every frame which acquired by CCD camera was integrated and the doses were calculated in pixel by pixel. The dose distributions from the fluorescent images were compared with the calculated dose distribution from the TPS. The discrepancies were evaluated as gamma index for each treatment. The curve for dose rate versus pixel value was not saturated until 900 MU/min. The 2D dosimetry using the phosphor screen and the CCD camera is respected to be useful to verify the dose distribution of the tomotherapy if the linearity correction of the phosphor screen improved.