• Title/Summary/Keyword: 간 초음파 영상

Search Result 230, Processing Time 0.031 seconds

Comparative evaluation of renal size on radiography and ultrasonography in rabbits (토끼의 방사선 촬영상과 초음파 촬영상에 나타난 신장 크기의 비교평가)

  • Choi, Min-cheol;Yin, Xi-jun;Lee, Hyo-jong;Kang, Tae-young
    • Korean Journal of Veterinary Research
    • /
    • v.36 no.4
    • /
    • pp.991-995
    • /
    • 1996
  • Renal size(length, width and height) of rabbits was measured by radiographs and nephrosonograms and compared with actual size. After measuring on the radiographs and nephrograms, both kidneys were removed from the body and actual size was also measured. On radiographs, right kidney was observed at the T13-L2 vertebrae and left kidney was at L2-L4 vertebrae. On nephrosonograms, the renal cortex was visible as small, homogenous echoes that were hypoechoic relative to the surrounding tissues, whereas the renal medulla was anechoic to slightly hypoechoic. The actual length, width and height of the left kidney were $35.84{\pm}3.12(mean{\pm}SD)$, $23.52{\pm}3.21$, $15.11{\pm}2.58cm$, respectively, whereas those of the right kidney were $36.02{\pm}3.42$, $23.69{\pm}3.50$ and $14.13{\pm}3.55cm$, respectively. On radiographs, the length and width of both kidneys were a little magnified(102-104%) when compared to actual size. On nephrosonograms, the length, width and height of bothkidneys were lessened(70-96 %) when compared to actual size. The length and width of kidney were 1.85 and 1.25 times the length of the second lumbar vertebrae on the ventrodorsal view. In correlation and correlation coefficient of body weight with the renal size, the body weight and renal size were significantly correlated with each other other(p<0.01) and the correlation coefficents of body weight with left, right and both Kindneys were 0.748, 0.794 and 0.859, respectively.

  • PDF

Usefulness of $^{99m}Tc$-labeled RBC Scan and SPECT in the Diagnosis of Head and Neck Hemangiomas (두경부 혈관종 진단시 $^{99m}Tc$-RBC Scan and SPECT 검사의 유용성)

  • Oh, Shin-Hyun;Roh, Dong-Wook;Ahn, Sha-Ron;Park, Hoon-Hee;Lee, Seung-Jae;Kang, Chun-Goo;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.1
    • /
    • pp.39-43
    • /
    • 2008
  • Purpose: There are various methods to diagnose hemangioma, such as ultrasonography (US), computed tomography (CT), magnetic resonance imaging (MRI) and nuclear medicine. However, by development of SPECT imaging, the blood-pool scan using $^{99m}Tc$-labeled red blood cell has been used, because it was non-invasive and the most economical method. Therefore, in this study, we proposed that the usefulness of $^{99m}Tc$-RBC scan and SPECT of the head and neck to diagnose unlocated hemangiomas. Materials and Methods: $^{99m}Tc$-RBC scan and SPECT was performed on 6 patients with doubtful hemangioma (4 person, head; 1 person, neck; 1 person, another). We labeled radiopharmaceutical using modified in vivo method and then, centrifuged it to remove plasma. After a bolus injection of tracer, dynamic perfusion flow images were acquired. Then, anterior, posterior, both lateral static blood-pool images were obtained as early and 4 hours delayed. SPECT was progressed 64 projections per 30 seconds. Each image was interpreted by physicians, Nuclear medicine specialist, and technologist blinded to patient's data. Results: In 5 patients of all the radioactivity of doubtful site didn't change in flow images, but, in blood-pool, delayed and SPECT images, it was increased. So, it was a typical hemangioma finding. The size of lesion was over 2 cm, and it could discriminate as comparing to the delayed and SPECT imaging. On the other hand, in 1 patient, the radioactivity was increased in blood-pool images, but, not in delayed and SPECT images, so, it was proved no hemangioma. Conclusion: Using $^{99m}Tc$-RBC Scan and SPECT, we could diagnose the hemangiomas in head and neck, as well as, liver, more non-invasive, economical, and easy. Therefore, it considered that $^{99m}Tc$-RBC scan and SPECT would offer more useful information for diagnosis of hemangioma, rather than otherimaging such as US, CT, MRI.

  • PDF

The Correlations of Parameters Using Contrast Enhanced Ultrasonography in the Evaluation of Prostate Cancer Angiogenesis (전립선암쥐모형의 신생혈관생성의 평가를 위해 시행된 역동적 조영 증강 초음파에서 얻은 변수간의 상관성연구)

  • Hwang, Sung Il;Lee, Hak Jong;Kim, Kil Joong;Chung, Jin-haeng;Jung, Hyun Sook;Jeon, Jong June
    • Ultrasonography
    • /
    • v.32 no.2
    • /
    • pp.132-142
    • /
    • 2013
  • Purpose: The purpose of this study is to investigate the correlations of various kinetic parameters derived from the time intensity curve in a xenograft mouse model injected with a prostate cancer model (PC-3 and LNCaP) using an ultrasound contrast agent with histopathologic parameters. Materials and Methods: Twenty nude mice were injected with human prostate cancer cells (15 PC-3 and five LNCaP) on their hind limbs. A bolus of $500{\mu}L$ ($1{\times}10^8$ microbubbles) of second-generation US contrast agent (SonoVue) was injected into the retroorbital vein. The region of interest was drawn over the entire tumor. The time intensity curve was acquired and then fitted to a gamma variate function. The maximal intensity (A), time to peak (Tp), maximal wash-in rate (washin), washout rate (washout), area under the curve up to 50 sec ($AUC_{50}$), area under the ascending slope ($AUC_{in}$), and area under the descending slope ($AUC_{out}$) were derived from the parameters of the gamma variate fit. Immunohistochemical staining for VEGF and CD31 was performed. Tumor volume, the area percentage of VEGF stained in a field, and the count of CD31 (microvessel density, MVD) positive vessels showed correlation with the parameters from the time intensity curve. Results: No significant differences were observed between the kinetic and histopathological parameters from each group. MVD showed positive correlation with A (r=0.625, p=0.003), washin (r=0.462, p=0.040), $AUC_{50}$ (r=0.604, p=0.005), and $AUC_{out}$ (r=0.587, p=0.007). Positive correlations were also observed between tumor volume and $AUC_{50}$ (r=0.481, p=0.032), washin (r=0.662, p=0.001), and $AUC_{out}$ (r=0.547, p=0.012). Washout showed negative correlations with MVD (r=-0.454, p=0.044) and tumor volume (r=-0.464, p=0.039). The area percentage of VEGF did not show any correlation with calculated data from the curve. Conclusion: MVD showed correlations with several of the kinetic parameters. CEUS has the potential for prediction of tumor vascularity in a prostate cancer animal model.

Descriptive Study for Sonographic Morphology of the 1st Facet of Subscapularis Footprint (견갑하건 부착부의 제1부착면에 대한 초음파 소견의 기술적 연구)

  • Sohn, Hoon-Sang;Wi, Chan Kuk;Shon, Min Soo
    • Journal of the Korean Orthopaedic Association
    • /
    • v.54 no.4
    • /
    • pp.343-352
    • /
    • 2019
  • Purpose: The purpose of this study was to document the sonographic morphology of the subscapularis footprint, particularly the 1st facet, of the non-pathologic subscapularis tendon and footprint, and analyze the correlation between the size of the 1st facet and the demographic variables. Materials and Methods: Between March 2015 and December 2017, retrospectively data analysis was performed for the ultrasound (US) scans of 115 consecutive shoulder (mean age 53.4 years, range 23-74 years) with non-pathologic subscapularis tendon and footprint. The sonographic findings of the 1st facet of the subscapularis footprint was a very unique, flat, broad, and plane angle in the upward direction, which were distinguished from the other facets. On US, the transverse (medio-lateral) and longitudinal (superior-inferior) length of the 1st facet on axis of the humerus shaft were recorded. The demographic variables, including age, site, body height, weight, body mass index (BMI), and arm length, were reviewed. Results: On US, the mean transverse length of the 1st facet was 12.75 mm (range 10.54-14.50 mm, standard deviation [SD] 0.712) and the mean longitudinal length was 12.22 mm (range 9.20-13.30 mm, SD 0.888). The transverse and longitudinal length of the size of the 1st facet were significantly greater in males than in females (p<0.001, p=0.001). Of the demographic data (body height, weight, BMI, arm length) that showed a significant positive linear correlation, the correlation with body height (transverse r=0.749, p<0.001; longitudinal r=0.642, p<0.001) showed the strongest relationship, and the correlation with the BMI was weakly related. The relationships between the size of the 1st facet to site/age were not statistically significant or appeared to have no linear correlation. Conclusion: The structural and morphologic features of the 1st facet of the subscapularis footprint on the US were identified. This will provide anatomic knowledge of an US examination for subscapularis tendon pathology.

Hepatic Parenchrmal Changes After Percutaneous Injection of Holmium-166 in Rabbit (가토 간내에 Holmium-166 주입 후의 간 실질 변화)

  • 최병인;김명진;박영년;김주희;최병욱
    • Investigative Magnetic Resonance Imaging
    • /
    • v.5 no.1
    • /
    • pp.43-48
    • /
    • 2001
  • Purpose : To evaluate changes in rabbit liver parenchyma on MR images following percutaneous Holmium-166 injection, and to correlate those changes with histologic findings. Materials and methods. Holmium-166 (10-25 mCi) was percutaneously injected into the liver of rabbit (n=12) under sonographic guidance. MR images were obtained between one to two weeks (acute phasea) after the injection in four rabbits, and between two to four weeks (subacute phase) after the injection in four rabbits. Tissue specimens of these eight rabbits were obtained immediately after MR imaging. Tissue specimens were obtained without MR imaging in four rabbits (between one to two weeks in one rabbit and between three to four weeks in three rabbits). Results : Tissue specimens showed central liquefactive necrosis and peripheral coagulative necrosis containing deposition of small particles and hemorrhage. The peripheral margin of the lesions showed formation of the granulation tissue with fibrosis, which tended to be more prominent in subacute phase. The area of the necrosis tended to correlate with the dose of the radioactive Holmium-166. On MR images, the central portion of the necrosis showed hyperintensity on 72-weighted image, hypointensity on the precontrast T1-weighted images, and no enhancement on the dynamic MR images. The peripheral portion of the necrosis showed hypointensity on T2-weighted images, iso or mild hypointensity on the T1-weighted images, and mild peripheral enhancement on the delayed dynamic MR images. The peripheral margin of the lesion showed hypointensity on both T1- and T1-weighted images with increased enhancement on the delayed phase images of the dynamic MR images. Conclusion : After percutaneous Holmium-166 injection into rabbit liver parenchyma, the central portion showed liquefactive necrosis, the peripheral portion showed coagulative necrosis with granulation, fibrosis, hemorrhage and depostition of small granules. MR imaging may be helpful in evaluation of the histological change of the liver after percutaneous Holmium-166 treatment.

  • PDF

Navigation system and 1:1 service for the people who are visually impaired using Android Platform (시각장애인을 위한 Android Platform기반의 Navigation System 설계 및 1:1 서비스 구현)

  • Lim, Ik-Chan;Kim, Young-Hil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.05a
    • /
    • pp.141-143
    • /
    • 2012
  • There are services, which can only verify simple objects ahead, to help visually impaired people using ultrasonic wave or RFID tag. Specially, RFID cannot manage emergency situations, since it is can only verify short distances. The purpose of the thesis is to design a device to provide locations in real time visually and audibly to the guardian of the user using Android Platform.

  • PDF

A Study on the Classification of Ultrasonic Liver Image Feature Vectors and the Design of Diagnosis System (초음파 간영상의 특징벡터 분류 및 진단시스템 구현에 관한 연구)

  • Jeong, Jeong-Won;Kim, Dong-Youn
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1995 no.11
    • /
    • pp.177-182
    • /
    • 1995
  • Since one property(i.e. coarseness, orientation, regularity, granularity etc.) of ultrasound liver images was not sufficiently enough to classify the characteristics of livers, we used the multi-feature vectors from ultrasound images to diagnose the liver disease. The proposed classifier, which uses the multi-feature vectors and Bayes decision rule, performed well for the classification of normal, fat and cirrhosis liver. In our simulation, we used the Battacharyya distance and Hotelling Trace Criterion to select the best multi-feature vectors for the classifier and obtained less classification errors than other methods using single feature vector.

  • PDF

Estimation of Attenuation Coefficient based on Ultrasonic Image for quantification of the Liver Diseases (간 병변의 정량화를 위한 초음파 영상 신호의 감쇄상수 추정)

  • 우광방;신동호;이성모;신영민;이노성;오성권
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.25 no.1
    • /
    • pp.49-55
    • /
    • 1988
  • To provide a quantitative parameter of evaluating diagnosis of the liver diseases accurately, the ultrasonic attenuation coefficient was estimated from liver phantoms, 15 normal human livers and 30 liver disease patients. Two kind of phantoms(No.1: 1552m/s, No.2: 1562m/s) which have velocity (1560m/s) similar to that in human liver were constructed and their ultrasonic attenuation coefficients were determined. In this paper the spectral-shift approach and spectral-difference approach were used for estimating ultrasonic attenuation coefficient, \ulcornerdB/Cm.MHz). These two approaches were utilized to esitmate for 15 normal humans without any liver disease and 30 liver disease patients. The results indicate that the two types of phantoms produce the value of near the suggested value of 0.5 and the attenuation coefficients of hepatoma, normal liver, corrhosis, fatty liver and hepatitis show decreasing value in order named, suggesting that the present study can be of clinical value incorrelating the estimated attenuation coefficidents with the liver diseases.

  • PDF

강조류 악시계 환경 탐사용 다관절 해저로봇 크랩스터 (CR200)

  • Jeon, Bong-Hwan
    • ICROS
    • /
    • v.19 no.3
    • /
    • pp.17-28
    • /
    • 2013
  • 조수간만의 차가 크고 지형이 복잡한 우리나라서 해안은 세계적으로도 보기 드문 강조류 환경이다. 잠수부의 안전을 위협하는 이러한 환경은 수중로봇의 접근도 쉽게 허락하지 않는다. 해저로봇 크랩스터는 이러한 특수한 환경을 조사하기 위해 고안된 수중보행로봇이다. 기존의 프로펠러 방식으로 달성하기 어려웠던 문제점을 크랩스터 로봇은 게나 가재와 같은 수중 생명체를 모방하여 극복하고자 했다. 크랩스터는 게나 가재의 기능을 모방함으로써 강조류 악시계 환경에서 유용한 두 가지 특징을 얻는다. 첫째는 해저에 밀착하여 자세를 제어함으로써 조류력을 이용하여 자세를 안정화시키면서 이동할 수 있다. 둘째는 조류 속에서 동요하지 않는 안정된 자세를 바탕으로 깨끗한 초음파 영상을 얻을 수 있다. 이는 강조류 환경에서 동반되는 부유물에 의한 악시계 환경을 극복할 수 있는 중요한 수단을 제공한다. 본 고에서는 이러한 개념에 따라 설계 개발된 크랩스터 CR200의 구성과 사양을 소개하고, 여기에 사용된 핵심기술을 살펴본다. 또한, 최근 수행된 CR200의 시험 결과에 대해서도 요약 소개한다.

The Ultrasound Imaging of the Tissue Attenuation Parameter in Human Liver (간 조직 감쇄 계수의 초음파 영상)

  • Song, In-Chan;Kwack, Cheol-Eun;Min, Byoung-Goo
    • Journal of Biomedical Engineering Research
    • /
    • v.11 no.2
    • /
    • pp.227-232
    • /
    • 1990
  • As a part of the study on ultrasonic tissue characterization, conventional ultrasonic imaging system is interfaced to the personal computer to acquire raw ultrasonic signal. One approach for tissue charaterization is performed using the attenuation map to the conventional images and the resulting attenuation map images are compared and inspected inside the region of interest from the viewpoint of pattern analysis. Currently, these methods are applied and modified to effectively find out the differences between the normal control and the patients with liver cirrhosis.

  • PDF