• Title/Summary/Keyword: 간접플라즈마

Search Result 26, Processing Time 0.02 seconds

Recent Trends in the Prevalence of Mycoplasma pneumoniae Pneumonia According to Age (연령에 따른 Mycoplasma pneumoniae 폐렴 발병의 최근 경향)

  • Lee, Hyo Sang;Choi, Kyong Min
    • Pediatric Infection and Vaccine
    • /
    • v.15 no.2
    • /
    • pp.162-166
    • /
    • 2008
  • Purpose : It has been previously reported that for patients with Mycoplasma pneumoniae pneumonia was previously recognized that overt illness is unusual under the age of three and the peak incidence of illness occurs in school-aged children. However, a higher incidence of this illness in younger children has been recently noted. Thus we investigated the incidence of M. pneumoniae pneumonia. Methods : The study subjects were 414 children who were diagnosed with M. pneumoniae pneumonia from January 2004 to December 2006 at Myong Ji Hospital were enrolled. The diagnostic criteria consisted of an anti-mycoplasma antibody (AMA) titer greater than 1: 320 or a four-fold rise in the titer at follow up. Results : The age distribution was as follows: before 2 years of age: 58 patients (14%), 2-4 years of age 157 patients (37.9%) and 5-15 years of age 199 patients (48.1%). The yearly incidence for the children before 5 years of age was 52 (44%), 49 (44.6%) and 114 (61.3%), respectively. The distribution according to the antibody titer was as follows; 1: 320 in 130 patients, 1:640 in 63 patients and greater than 1:1,280 in 221 patients. The hospital stay according to the antibody titer was not significant according to either age or the AMA titers. Conclusion : M. pneumoniae pneumonia showed a peak incidence in preschool children with a higher prevalence in children under the age of three than was previously recognized. The emergence of M. pneumoniae pneumonia as a cause of community acquired pneumonia in younger children calls for an epidemiologic study to investigate the changes of the pathogens in this age group and to recommend the proper treatment.

  • PDF

OPTICAL DESIGN OF THE FAR ULTRAVIOLET IMAGING SPECTROGRAPH (원자외선 영상/분광 측정기 광학설계)

  • ;;;Jerry Edelstein
    • Journal of Astronomy and Space Sciences
    • /
    • v.15 no.2
    • /
    • pp.359-371
    • /
    • 1998
  • We present the design specifications and the performance estimation of the FUVS (Far Ultraviolet Spectrograph) proposed for the observations of aurora, day/night airglow and astronomical objects on small satelltes in the spectral range of $900~1750AA$. The design of FUVS is carried out with the full consideration of optical characteristics of the grating and the aspheric substrate. Two independent methods, ray-tracing and the wave front aberration theory, are employed to estimate the performance of the optical design and it is verified that both procedures yield the resolution of $2~5AA$ in the entire spectral range. MDF (Minimum Detectable Flux) is also estimated using the known characteristics of the reflecting material and MCP, to study the feasibility of detection for faint emission lines from the hot interstellar plasmas. The results give that the observations from 1 day to 1 week, depending on the line intensity, can detect such faint emission lines from diffuse interstellar plasmas.

  • PDF

Decomposition of odor using atmospheric-pressure plasma (플라즈마를 이용한 악취물질 분해 특성)

  • Kang, Seok-Won;Lee, Jae-Sik;Lee, Kang-San;Lim, Hee-Ah;Kim, Ji-Seong;Lee, Jeong-Dae;Park, Wol-Su;Park, Young-Koo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.7
    • /
    • pp.708-718
    • /
    • 2020
  • Offensive odor is recognized as a social environmental problem due to its olfactory effects. Ammonia(NH3), hydrogen sulfide(H2S) and benzene(C6H6) are produced from various petrochemical plants, public sewage treatment plants, public livestock wastes, and food waste disposal facilities in large quantities. Therefore efficient decomposition of offensive odor is needed. In this study, the removal efficiency of atmospheric-pressure plasma operating at an ambient condition was investigated by evaluating the concentrations at upflow and downflow between the plasma reactor. The decomposition of offensive odor using plasma is based on the mechanism of photochemical oxidation of offensive odor using free radical and ozone(O3) generated when discharging plasma, which enables the decomposition of offensive odor at ordinary temperature and has the advantage of no secondary pollutants. As a result, all three odor substances were completely decontaminated within 1 minute as soon as discharging the plasma up to 500 W. This result confirms that high concentration odors or mixed odor materials can be reduced using atmospheric-pressure plasma.

Tunnel Magnetoresistance with Top Layer Plasma Oxidation Time in Doubly Oxidized Barrier Process (이중 절연층 공정에서 상부절연층의 산화시간에 따른 터널자기저항 특성연구)

  • Lee, Ki-Yung;Song, Oh-Sung
    • Journal of the Korean Magnetics Society
    • /
    • v.12 no.3
    • /
    • pp.99-102
    • /
    • 2002
  • We fabricated TMR devices which have doubly oxidized tunnel barrier using plasma oxidation method to form homogeneously oxidized AlO tunnel barrier. We sputtered 10 $\AA$-bottom Al layer and oxidized it with oxidation time of 10 sec. Subsequent sputtering of 13 $\AA$-Al was performed and the metallic layer was oxidized for 50, 80, and 120 sec., respectively. The electrical resistance changed from 500 Ω to 2000 Ω with increase of oxidation time, while variation of MR ratio was little spreading 27∼31 % which is larger than that of TMR device of ordinary single tunnel barrier. We calculated effective barrier height and width by measuring I-V curves, from which we found the barrier height was 1.3∼1.8 eV sufficient for tunnel barrier, and the barrier width (<15.0 $\AA$) was smaller than physical thickness. Our results may be caused by insufficient oxidation of Al precursor into A1$_2$O$_3$. However, doubly oxidized tunnel barriers were superior to conventional single tunnel barrier in uniformity and density. Our results imply that we were able to improve MR ratio and tune resistance by employing doubly oxidized tunnel barrier process.

Serodiagnosis of canine toxoplasmosis by latex agglutination and indirect fluorescent antibody test (Latex 응집반응과 간접형광항체법을 이용한 개 톡소플라즈마병의 혈청학적 진단)

  • Lee, Byung-hoon;Lee, Eung-goo;Suh, Myung-deuk
    • Korean Journal of Veterinary Research
    • /
    • v.32 no.4
    • /
    • pp.641-647
    • /
    • 1992
  • This study was conducted to determine the serum antibodies against toxoplasma in the artificially infected dogs, pet and street dogs by latex agglutination (LA) and indirect fluorescent antibody (IFA) test. LA test was carried out with commercial Toxo-MT kit (Eiken chemical Co.) and IFA test was carried out with rabbit-anti-dog IgG labelled with FITC (Cappel Co.) and toxo-antigen slides prepared in laboratory. The results obtained were as follows ; 1. Antibodies to Toxoplasma gondii in the artificially infected dogs were detected firstly at the Day 8 in IFA and Day 9 in LA test after inoculation. Positive antibody reactions by these tests were declined gradually afterward but maintained up to 12 weeks. 2. In LA test serum antibody titers in 310 test sera were shown as 10 cases(32%) in 1 : 32.5(1.0%) in 1 : 64, 4(1.3%) in 1 : 128 and 2(0.7%) in 1 : 256. In IFA test serum antibody titers 310 test sera were shown as 17 cases(5.5%) in 1 : 64, 8(2.6%) in 1 : 128 and 5(1.6%) in 1 : 256. 3. In the total of 310 sera from pet and street dogs toxoplasma antibody positive rates were 21 cases (6.8%) by LA and 30 cases (9.7%) by IFA test and the positive detection rates between these two groups by LA and IFA test were not significant(p<0.05). 4. In the total of 115 sera from pet dogs toxoplasma antibody positive rates were 12 cases(10.4%) by LA and 15(13.0%) by IFA test. And in the 195 street dogs the positive rates were 9 cases(4.6%) by LA and 15(7.7%) by IFA test. Also, the positive detection rates between these two groups by LA and IFA test were not significant(p<0.05). 5. Agreement of reactivity between LA and IFA test for 310 sera was 91.3% in total of 283 cases consisting of 12 cases(3.9%) of both LA and IFA positive and 271 cases(87.4%) of LA and IFA negative. 6. LA test was almostly equivalent to the IFA test in producibility and proved to be a simple tool for the screening of toxoplasma antibody in laboratory.

  • PDF

Sputtering방식을 이용한 Indium Thin oxide박막의 넓이에 따른 X-ray 검출기 특성 연구

  • Kim, Dae-Guk;Sin, Jeong-Uk;O, Gyeong-Min;Kim, Seong-Heon;Lee, Yeong-Gyu;Jo, Seong-Ho;Nam, Sang-Hui
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.321-322
    • /
    • 2012
  • 의료용 방사선 장비는 초기의 아날로그 방식의 필름 및 카세트에서 진보되어 현재는 디지털 방식의 DR (Digital Radiography)이 널리 사용되며 그에 관한 연구개발이 활발히 진행되고 있다. DR은 크게 간접방식과 직접방식의 두 분류로 나눌 수 있는데, 간접방식은 X선을 흡수하면 가시광선으로 전환하는 형광체(Scintillator)를 사용하여 X선을 가시광선으로 전환하고, 이를 Photodiode와 같은 광소자로 전기적 신호로 변환하여 방사선을 검출하는 방식을 말하며, 직접 방식은 X선을 흡수하면 전기적 신호를 발생 시키는 광도전체(Photoconductor)를 사용하여 광도전체 양단 전극에 고전압을 인가한 형태를 취하고 있는 가운데, X선이 조사되면 일차적으로 광도전체 내부에서 전자-전공쌍(Electron-hole pair)이 생성된다. 이들은 광도전체 양단의 인가되어 있는 전기장에 의해 전자는 +극으로, 전공은 -극으로 이동하여 아래에 위치한 Active matrix array을 통해 방사선을 검출하는 방식이다. 본 연구에서는 직접방식 X-ray 검출기에서 활용되는 a-Se을 ITO (Indium Thin oxide) glass 상단에 Thermal evaporation증착을 이용하여 두께 $50{\mu}m$, 33 넓이로 증착 시킨 다음, a-Se상단에 Sputtering증착을 이용하여 ITO를 11 cm, 22 cm, $2.7{\times}2.7cm$ 넓이로 증착시켜 상하부의 ITO를 Electrode로 이용하여 직접방식의 X-ray검출기 샘플을 제작하였다. 제작 과정 중 a-Se의 Thermal evaporation증착 시, 저진공 $310^{-3}_{Torr}$, 고진공 $2.210^{-5}_{Torr}$에서 보트의 가열 온도를 두 번의 스텝으로 나누어 증착 시켰다. 첫 번째 스텝 $250^{\circ}C$, 두 번째 스텝은 $260^{\circ}C$의 조건으로 증착하여 보트 내의 a-Se을 남기지 않고 전량을 소모할 수 있었으며, 스텝간의 온도차를 $10^{\circ}C$로 제어하여 균일한 박막을 형성 할 수 있었다. Sputtering증착 시, 저진공 $2.510^{-3}$, 고진공 $310^{-5}$에서 Ar, $O_2$를 사용하여 100 Sec간 플라즈마를 생성시켜 ITO를 증착하였다. 제작된 방사선 각각의 검출기 샘플 양단의 ITO에 500V의 전압을 인가하고, 진단 방사선 범위의 70 kVp, 100 mA, 0.03 sec 조건으로 X-ray를 조사시켜 ITO넓이에 따른 민감도(Sensitivity)와 암전류(Dark current)를 측정하였다. 측정결과 민감도(Sensitivity)는 X-ray샘플의 두께에 따른 $1V/{\mu}m$ 기준 시, 증착된 ITO의 넓이가 11 cm부터 22 cm, $2.7{\times}2.7cm$까지 각각 $7.610nC/cm^2$, $8.169nC/cm^2$, $6.769nC/cm^2$로 22 cm 넓이의 샘플이 가장 높은 민감도를 나타내었으나, 암전류(Dark current)는 $1.68nA/cm^2$, $3.132nA/cm^2$, $5.117nA/cm^2$로 11 cm 넓이의 샘플이 가장 낮은 값을 나타내었다. 이러한 데이터를 SNR (Signal to Noise Ratio)로 합산 하였을 시 104.359 ($1{\times}1$), 60.376($2{\times}2$), 30.621 ($2.7{\times}2.7$)로 11 cm 샘플이 신호 대 별 가장 우수한 효율을 나타냄을 알 수 있었다. 따라서 ITO박막의 면적이 클수록 민감도는 우수하나 그에 따른 암전류의 증가로 효율이 떨어짐을 검증 할 수 있었으며, 이는 ITO면적이 넓어짐에 따른 저항의 증가로 암전류에 영향을 끼침을 할 수 있었다. 본 연구를 통해 a-Se의 ITO 박막 면적에 따른 전기적 특성을 검증할 수 있었다.

  • PDF