• Title/Summary/Keyword: 간접측정법

Search Result 213, Processing Time 0.029 seconds

Effect of curing modes on micro-hardness of dual-cure resin cements (중합방법이 이중중합 레진시멘트의 미세경도에 미치는 영향)

  • Lee, Ki-Deok;Park, Se-Hee;Kim, Jin-Woo;Cho, Kyung-Mo
    • Restorative Dentistry and Endodontics
    • /
    • v.36 no.2
    • /
    • pp.132-138
    • /
    • 2011
  • Objectives: The purpose of this study was to evaluate curing degree of three dual-cure resin cements with the elapsed time in self-cure and dual-cure mode by means of the repeated measure of micro-hardness. Materials and Methods: Two dual-cure self-adhesive resin cements studied were Maxcem Elite (Kerr), Rely-X Unicem (3M ESPE) and one conventional dual-cure resin cement was Rely-X ARC resin cement (3M ESPE). Twenty specimens for each cements were made in Teflon mould and divided equally by self-cure and dual-cure mode and left in dark, $36^{\circ}C$, 100% relative humidity conditional-micro-hardness was measured at 10 min, 30 min, 1 hr, 3 hr, 6 hr, 12 hr and 24 hr after baseline. The results of micro-hardness value were statistically analyzed using independent samples t-test and one-way ANOVA with multiple comparisons using Scheffe's test. Results: The micro-hardness values were increased with time in every test groups. Dual-cure mode obtained higher micro-hardness value than self-cure mode except after one hour of Maxcem. Self-cured Rely-X Unicem showed lowest value and dual-cured Rely-X Unicem showed highest value in every measuring time. Conclusions: Sufficient light curing to dual-cure resin cements should provided for achieve maximum curing.

Relation of head posture and occlusal contact area using photo occlusion analysis (광조사교합분석법을 이용한 머리 위치와 교합접촉면적의 관계)

  • Kim, Chang-Hwan;Ko, Kyung-Ho;Huh, Yoon-Hyuk;Cho, Lee-Ra;Park, Chan-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.35 no.2
    • /
    • pp.90-97
    • /
    • 2019
  • Purpose: Previous studies related with occlusal contact area were limited that interocclusal thickness level or the method of measurement has not been accurate in measuring. The purpose of this study was to investigate the relation between head posture and occlusal contact area using photo occlusion analysis. Materials and Methods: 54 subjects with complete dentition (44 men, 10 women / 23 to 33 years of age) were included. To identify the relationship between head posture and occlusal contact area, subjects took interocclusal record in maximal intercuspal position with three different positions(supine position ($0^{\circ}$) / inclined position ($45^{\circ}$) / upright position ($90^{\circ}$)) on the dental unit chair. Occlusal contact area was analyzed using photo occlusion analysis. Statistical analyses were performed with SPSS ver.25.0 at 95% confidence interval. Results: Head posture has no significant effect on the changes of occlusal contact area (P > 0.05). Conclusion: When interocclusal relation is stable, head posture does not change a interocclusal record because head posture has no significant effect on occlusal contact area. Analysis of occlusal contact area using photo occlsion analysis device is useful due to its material property and simplicity.

Photoacoustic Investigation of Carrier Transport and Thermal Diffusivity in GaAs and Si (광음향분광법을 이용한 GaAs와 Si 반도체의 열확산도 측정과 운반자특성 연구)

  • Lim, Jong Tae;Han, Ho Youn;Park, Seung Han;Kim, Ung;Choi, Joong Gill
    • Journal of the Korean Chemical Society
    • /
    • v.41 no.7
    • /
    • pp.329-336
    • /
    • 1997
  • Photoacoustic spectroscopy was utilized to investigate the carrier transport and the thermal diffusivity in GaAs and Si. From the frequency dependence of the photoacoustic signal, it is found that heat source was originated from the instantaneous thermalization process in low frequency region. In high frequency region, however, the heat was generated by the nonradiative bulk recombination and the nonradiative surface recombination processes. It was also shown that the photoacoustic effects in GaAs of a direct band gap were governed by all three processes and those in Si of an indirect band gap were produced by the instantaneous thermalization and the nonradiative bulk recombination only. The phase of the photoacoustic signal showed a minimum value in GaAs. In Si, the phase of the photoacoustic signal was monotonically decreased as the modulation frequency was increased, demonstrating the above-mentioned mechanisms of the generation of heat. By measuring the photoacoustic signal, thermal diffusivities of semiconductors were determined to be ∼0.35 ㎠/s for GaAs and ∼1.24 ㎠/s for Si. In addition, the similar values of thermal diffusivities were obtained from the curve fitting of photoacoustic phase spectra.

  • PDF

EEG 16 channel variations between the non-stimulation and the moxibustion stimulated subjects for CV4, CV8, and CV12 acupuncture points (중완, 신궐 및 관원 경혈의 뜸 자극과 무 자극 대상군의 16채널 뇌파 변화에 관한 연구)

  • Yoon, Dong-Eop;Song, Hong-Bok
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.12
    • /
    • pp.2755-2760
    • /
    • 2010
  • The moxibustion therapy of orient medical is well known. Moxibustion method is used to burning moxibustion. The variation factors of the moxibustion stimulation for body can be applied to the electronic moxibustion method. This study is to analyze and examine the electroencephalogram(EEG) variations for moxibustion stimulation. In experiment, we divided six healthy male subjects into two same sized groups : with and without stimuli. The given stimuli are the moxibustion for CV4(Kwan-Won), CV8(Shin-Guel), and CV12(Jung-wan) acupuncture points. We have analyzed the power spectrum for ${\alpha}$, ${\beta}$, ${\delta}$, ${\Theta}$ waves and the average EEG variation level and each channels variation level of EEG. The result was that the moxibustion stimulation decreased the EEG levels of parietal lobe(ch 2, 3, 6, 7) according to the somatosensory system. And the apparent different points are that mild-heat($42{\sim}44^{\circ}C$) stimulation generating ${\alpha}$-wave is increased and ${\beta}$-wave is decreased, also slight-hot($45{\sim}48^{\circ}C$) stimulation made ${\alpha}$-wave decrease and ${\beta}$-wave increase for occipital lobe(ch 4,8) on the simulation group.

A Decade's Experiences on the Hydrofracturing In-Situ Stress Measurement for Tunnel Construction in Korea (암반터널 설계를 위한 수압파쇄 초기지압 측정의 10여년 간의 경험)

  • Choe, Seong-Ung;Park, Chan;Sin, Jung-Ho;Sin, Hui-Sun
    • Proceedings of the Korean Society for Rock Mechanics Conference
    • /
    • 2008.03a
    • /
    • pp.79-88
    • /
    • 2008
  • Since the hydraulic fracturing field testing method was introduced first to Korean geotechnical engineers in 1994, there have been lots of progresses in a hardware system as well as an interpretation tool. The hydrofracturing system of first generation was the pipe-line type, so it was not easy to handle. It had been modified to a wire-line system at their second generation. It was more compact one but it also needed an additional air-compressor. Our current system is much more compact and operated by all-in-one system, so it doesn't need an additional air-compressor. With a progress in a hardware system, the software for analyzing the in-situ stress regime has also been progressed. For example, the shut-in pressure, which is the most ambiguous parameter to be obtained from hydrofracturing pressure curves, can now be acquired automatically from the various methods. While the hardware and software for hydrofracturing tests are being developed during the last decade, the author could accumulate the field test results which can cover the almost whole area of South Korea. Currently these field data are used widely in a feasibility study or a preliminary design step for tunnel construction in Korea. Regarding the difficulties in a site selection and a test performance for the in-situ stress measurement at an off-shore area, the in-situ stress regime obtained from the field experiences in the land area can be used indirectly for the design of a sub-sea tunnel. From the hydrofracturing stress measurements, the trend of magnitude and direction of in-situ stress field was shown identically with the geological information in Korea.

  • PDF

Accuracy evaluation of microwave water surface current meter for measurement angles in middle flow condition (전자파표면유속계의 측정 각도에 따른 평수기 유속 측정 정확도 분석)

  • Son, Geunsoo;Kim, Dongsu;Kim, Kyungdong;Kim, Jongmin
    • Journal of Korea Water Resources Association
    • /
    • v.53 no.1
    • /
    • pp.15-27
    • /
    • 2020
  • Streamflow discharge as a fundamental riverine quantity plays a crucial role in water resources management, thereby requiring accurate in-situ measurement. Recent advances in instrumentations for the streamflow discharge measurement has complemented or substituted classical devices and methods. Among various potential methods, surface current meter using microwave has increasingly begun to be applied not only for flood but also normal flow discharge measurement, remotely and safely enabling practitioners to measure flow velocity postulating indirect contact. With minimized field preparedness, this method facilitated and eased flood discharge measurement in the difficult in-situ conditions such as extreme flood in active ways emitting 24.125 GHz microwave without relying on natural lights. In South Korea, a rectangular shaped instrument named with Microwave Water Surface Current Meter (MWSCM) has been developed and commercially released around 2010, in which domestic agencies charging on streamflow observation shed lights on this approach regarding it as a potential substitute. Considering this brand-new device highlighted for efficient flow measurement, however, there has been few noticeable efforts in systematic and comprehensive evaluation of its performance in various measurement and riverine conditions that lead to lack in imminent and widely spreading usages in practices. This study attempted to evaluate the MWSCM in terms of instrumen's monitoring configuration particularly regarding tilt and yaw angle. In the middle of pointing the measurement spot in a given cross-section, the observation campaign inevitably poses accuracy issues related with different tilt and yaw angles of the instrument, which can be a conventionally major source of errors for this type of instrument. Focusing on the perspective of instrument configuration, the instrument was tested in a controlled outdoor river channel located in KICT River Experiment Center with a fixed flow condition of around 1 m/s flow speed with steady flow supply, 6 m of channel width, and less than 1 m of shallow flow depth, where the detailed velocity measurements with SonTek micro-ADV was used for validation. As results, less than 15 degree in tilting angle generated much higher deviation, and higher yawing angle proportionally increased coefficient of variance. Yaw angles affected accuracy in terms of measurement area.

Development of Unfolding Energy Spectrum with Clinical Linear Accelerator based on Transmission Data (물질투과율 측정정보 기반 의료용 선형가속기의 에너지스펙트럼 유도기술 개발)

  • Choi, Hyun Joon;Park, Hyo Jun;Yoo, Do Hyeon;Kim, Byoung-Chul;Yi, Chul-Young;Min, Chul Hee
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.1
    • /
    • pp.41-47
    • /
    • 2016
  • Background: For the accurate dose assessment in radiation therapy, energy spectrum of the photon beam generated from the linac head is essential. The aim of this study is to develop the technique to accurately unfolding the energy spectrum with the transmission analysis method. Materials and Methods: Clinical linear accelerator and Monet Carlo method was employed to evaluate the transmission signals according to the thickness of the observer material, and then the response function of the ion chamber response was determined with the mono energy beam. Finally the energy spectrum was unfolded with HEPROW program. Elekta Synergy Flatform and Geant4 tool kits was used in this study. Results and Discussion: In the comparison between calculated and measured transmission signals using aluminum alloy as an attenuator, root mean squared error was 0.43%. In the comparison between unfolded spectrum using HEPROW program and calculated spectrum using Geant4, the difference of peak and mean energy were 0.066 and 0.03 MeV, respectively. However, for the accurate prediction of the energy spectrum, additional experiment with various type of material and improvement of the unfolding program is required. Conclusion: In this research, it is demonstrated that unfolding spectra technique could be used in megavoltage photon beam with aluminum alloy and HEPROW program.

The Influence of Epinephrine Concentration in Local Anesthetics on Pulpal and Gingival Blood Flows (국소마취제에 함유된 에피네프린의 농도가 치수 및 치은 혈류에 미치는 영향)

  • Lee, Jae-Sang;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.28 no.6
    • /
    • pp.475-484
    • /
    • 2003
  • 동통조절을 위해 국소마취제는 치과임상에서 광범위하게 사용되어진다. 가장 널리 쓰이는 국소마취제는 리도카인이고 이는 마취효과의 지속 및 지혈효과 등의 목적으로 혈관수축제를 포함하고 있다. 대표적 혈관수축제인 에피네프린은 임상에서 1:300,000에서부터 1:50,000의 농도로 다양하게 사용되어진다. 수복치료를 위해서는 통상적으로 1:100.000농도의 에피네프린이 사용되고 있고 외과적 근관치료시 지혈효과를 위해서는 1:50,000농도의 에피네프린이 추천되고 있다. 이들 농도의 에피네프린을 포함한 리도카인으로 국소마취시 에피네프린의 농도가 치수의 혈류 및 치은의 혈류에 미치는 영향을 이해할 필요가 있고 그 영향이 전기치수검사에 대한 치수의 반응성에 미치는 영향도 이해할 필요가 있다. 따라서 혈관수축제를 포함한 국소마취제에 의한 치수혈류의 변화와 치수신경의 반응성을 이해하는 것은 중요하다 하겠다. 본 연구의 목적은 두 가지 농도의 에피네프린을 포함한 국소마취제로 마취시 나타나는 치수 및 치은의 혈류 변화를 치수신경의 반응성과 비교, 관찰함으로써 국소마취제가 치수 및 치은에 미치는 영향을 파악하고자 함에 있다. 24세에서 27세까지의 10명의 피검자의 건전한 상악중절치를 시험에 이용하였다. Laser Doppler flowmeter의 probe을 고정하기 위한 splint를 간접법으로 인상용 putty를 이용하여 제작하고 치수 및 치은의 혈류량, 그리고 전기치수검사에 대한 반응성을 측정하기 위한 3개의 구멍을 만들었다. 피검자를 10분간 안정시킨 후 마취 전 10분간 정상 혈류량과 전기검사치를 측정하고 1:50,000 epinephrine과 1:100,00 epinephrine이 각각 함유된 2% 리도카인 용액 0.9 ml를 상악 좌측 중절치 치근단부위 협점막에 침윤마취하였다. 마취 후 70분간 치수 및 치은 혈류량을 laser Doppler flowmeter를 이용해 연속적으로 측정하여 그 수치를 컴퓨터에 저장하였고, 매 5분 간격으로 전기치수검사를 시행하여 그 측정치를 기록하였다. 매 시간 간격의 평균 혈류량을 정상 혈류량에 대한 백분율로 나타내고, 각각의 농도에서 최소 치수 및 치은 혈류량을 Paired t-test, Wilcoxon's signed rank test. Duncan's multiple range test. Fisher's exact test등을 이용. 통계분석 하여 다음과 같은 결과를 얻었다. 에피네프린이 함유되어 있지 않은 리도카인을 협점막에 주사시 혈류변화가 거의 나타나지 않았으나 1:50,000 및 1:100.000 에피네프린이 함유된 2% 리도카인을 협점막에 침윤마취시 치수 및 치은 혈류 공히 현저히 감소하였다(p<0.01). 1:50,000 에피네프린군은 1:100,000 에피네프린군에 비해 치수 혈류량이 현저히 억제되어 나타났으나(p<0.01), 치은 혈류량에서는 유의성 있는 차이를 나타내지 않았다(p>0.05). 두 농도의 에피네프린 군 공히 치은혈류는 치수혈류에 비해 유의하게 많은 감소를 나타내었다(p<0.05). 1:100,000 에피네프린 군에서 마취액 주입 후 치수혈류 최대감소가 가장 먼저 나타났고 이어서 전기검사에 대한 치수의 반응성 소실 및 치은혈류 최대 감소의 순으로 나타났다(p<0.05). 1:50,000 에피네프린군의 경우가 1:100,000 에피네프린군의 경우에 비해 마취지속시간이 길게 나타났으나 유의성은 없었다(p>0.05).

A Study on Tension for Cables of a Cable-stayed Bridge Damper is Attached (댐퍼가 부착된 사장교의 케이블 장력에 관한연구)

  • Park, Yeon Soo;Choi, Sun Min;Yang, Won Yeol;Hong, Hye Jin;Kim, Woon Hyung
    • Journal of Korean Society of Steel Construction
    • /
    • v.20 no.5
    • /
    • pp.609-616
    • /
    • 2008
  • Recently, many ocean bridges that connect land to island or island to island have been constructed along with the improvement of the nation's economy. Long-span bridges can be categorized as suspension bridge, cable-stayed bridge, arch bridge and truss bridge. In this study, correction with respect to construction error can be presented on site through the monitoring of the cable tension change of real structure for four major construction stages so that construction accuracy, including the management of profiles, can be improved. A vibration method, the so-called indirect method that uses the cable's natural frequency changes from the acceleration sensor installed on the cable, is applied in measuring cable tension. In this study, the estimation formula for the effective length of cable with damper is presented by comparing and analyzing between actual measurement and analysis result for the change of the cable's effective length. By the way, it is known that the reliability of estimating cable tension by applying the former method that uses the net distance from damper to anchorage is low. Therefore, for future reference of the maintenance stage, the presented formula for estimating the effective length of cable can be used as a reference for the rational decision-making, such as the re-tensioning and replacement of cable.

Performance of Northern Exposure Index in Reducing Estimation Error for Daily Maximum Temperature over a Rugged Terrain (북향개방지수가 복잡지형의 일 최고기온 추정오차 저감에 미치는 영향)

  • Chung, U-Ran;Lee, Kwang-Hoe;Yun, Jin-I.
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.9 no.3
    • /
    • pp.195-202
    • /
    • 2007
  • The normalized difference in incident solar energy between a target surface and a level surface (overheating index, OHI) is useful in eliminating estimation error of site-specific maximum temperature in complex terrain. Due to the complexity in its calculation, however, an empirical proxy variable called northern exposure index (NEI) which combines slope and aspect has been used to estimate OHI based on empirical relationships between the two. An experiment with real-world landscape and temperature data was carried out to evaluate performance of the NEI - derived OHI (N-OHI) in reduction of spatial interpolation error for daily maximum temperature compared with that by the original OHI. We collected daily maximum temperature data from 7 sites in a mountainous watershed with a $149 km^2$ area and a 795m elevation range ($651{\sim}1,445m$) in Pyongchang, Kangwon province. Northern exposure index was calculated for the entire 166,050 grid cells constituting the watershed based on a 30-m digital elevation model. Daily OHI was calculated for the same watershed ana regressed to the variation of NEI. The regression equations were used to estimate N-OHI for 15th of each month. Deviations in daily maximum temperature at 7 sites from those measured at the nearby synoptic station were calculated from June 2006 to February 2007 and regressed to the N-OHI. The same procedure was repeated with the original OHI values. The ratio sum of square errors contributable by the N-OHI were 0.46 (winter), 0.24 (fall), and 0.01 (summer), while those by the original OHI were 0.52, 0.37 and 0.15, respectively.