• Title/Summary/Keyword: 간접촬영

Search Result 77, Processing Time 0.027 seconds

Image Quality Evaluation of CsI:Tl and Gd2O2S Detectors in the Indirect-Conversion DR System (간접변환방식 DR장비에서 CsI:Tl과 Gd2O2S의 검출기 화질 평가)

  • Kong, Changgi;Choi, Namgil;Jung, Myoyoung;Song, Jongnam;Kim, Wook;Han, Jaebok
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.1
    • /
    • pp.27-35
    • /
    • 2017
  • The purpose of this study was to investigate the features of CsI:Tl and $Gd_2O_2S$ detectors with an indirect conversion method using phantom in the DR (digital radiography) system by obtaining images of thick chest phantom, medium thickness thigh phantom, and thin hand phantom and by analyzing the SNR and CNR. As a result of measuring the SNR and CNR according to the thickness change of the subject, the SNR and CNR were higher in CsI:Tl detector than in $Gd_2O_2S$ detector when the medium thickness thigh phantom and thin hand phantom were scanned. However, when the thick chest phantom was used, for the SNR at 80~125 kVp and the CNR at 80~110 kVp in the $Gd_2O_2S$ detector, the values were higher than those of CsI:Tl detector. The SNR and CNR both increased as the tube voltage increased. The SNR and CNR of CsI:Tl detector in the medium thickness thigh phantom increased at 40~50 kVp and decreased as the tube voltage increased. The SNR and CNR of $Gd_2O_2S$ detector increased at 40~60 kVp and decreased as the tube voltage increased. The SNR and CNR of CsI:Tl detctor in the thin hand phantom decreased at the low tube voltage and increased as the tube voltage increased, but they decreased again at 100~110 kVp, while the SNR and CNR of $Gd_2O_2S$ detector were found to decrease as the tube voltage increased. The MTF of CsI:Tl detector was 6.02~90.90% higher than that of $Gd_2O_2S$ detector at 0.5~3 lp/mm. The DQE of CsI:Tl detector was 66.67~233.33% higher than that of $Gd_2O_2S$ detector. In conclusion, although the values of CsI:Tl detector were higher than those of $Gd_2O_2S$ detector in the comparison of MTF and DQE, the cheaper $Gd_2O_2S$ detector had higher SNR and CNR than the expensive CsI:Tl detector at a certain tube voltage range in the thick check phantom. At chest X-ray, if the $Gd_2O_2S$ detector is used rather than the CsI:Tl detector, chest images with excellent quality can be obtained, which will be useful for examination. Moreover, price/performance should be considered when determining the detector type from the viewpoint of the user.

Evaluate Utility of Thyroid Incidentaloma Discrimination by $^{18}F$-FDG PET/CT Delay Scan Images ($^{18}F$-FDG PET/CT검사에서 지연영상을 이용한 갑상선 우연종 감별의 유용성 평가)

  • Lee, Hyun-Kuk;Yang, Seoung-Oh;Song, Gi-Deok;Song, Chi-Ock;Lee, Gi-Heun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.3
    • /
    • pp.184-191
    • /
    • 2008
  • Purpose: To evaluate the degree of malignancy of incident thyroid lesion found in $^{18}F$-FDG PET/CT findings and the usefulness of the method suggested in this study, we applicate the Delay Scan Method that differentiate a false positive benign tumor, inflammation and malignancy, as well as make the criteria of SUV. Materials and Methods: A retrograde study was conducted of 800 patients who were admitted in E hospital to receive $^{18}F$-FDG PET/CT examination. One patient who was diagnosed as primary thyroid cancer and received $^{18}F$-FDG PET/CT examination was excluded. The number of final patients of this study was 799, the reasons of $^{18}F$-FDG PET/CT examination of these patients were follow-up of old cancer or suspicious tumorous lesion in 696 and disease screening in 103. $^{18}F$-FDG PET/CT image photographing was taken in Biograph-Duo made by SIEMENS, after taking normal $^{18}F$-FDG PET/CT image (1 hr) and then 1 hr later we took the thyroid 1 bed-delayed image for the patients who showed abnormal thyroid $^{18}F$-FDG uptake and above 2.0 SUV for 2 minutes every 1 bed. For the patients who showed abnormal thyroid uptake and above 2.0 SUV, 1 hr later, we took a 1 bed-delayed image and then made a comparative study between measured $SUV_{max}$ of 1 hr-abnormal uptake image and that of 2 hr-delayed image. Results and Conclusion: In this $^{18}F$-FDG PET/CT study among the patients who showed incidental $^{18}F$-FDG thyroidal uptake the number of thyroid incidentaloma was 5 (0.63%), all of then showed benign findings. And in the case of incidental $^{18}F$-FDG uptake in thyroid, $SUV_{max}$ variance obtained from 2 hr delayed image can be a indirect criteria in differentiating benign tumor from malignancy and decrease finding error. In the cases found thyroid incidentaloma when 1) $SUV_{max}$ of focal thyroid lesion is above 5.0 and 2) $SUV_{max}$ variance between normal $^{18}F$-FDG PET/CT exam and 2 hr delayed is $1.0{\pm}0.5$, they are suspected as malignancy and confirming biopsy is to be followed. Otherwise, I also think that distinct follow-up PET or CT image study is a reasonable diagnostic method.

  • PDF

The Irradiated Lung Volume in Tangential Fields for the Treatment of a Breast (유방암의 접선 조사시 피폭 폐용적)

  • Oh Young Taek;Kim Juree;Kang Haejin;Sohn Jeong Hye;Kang Seung Hee;Chun Mison
    • Radiation Oncology Journal
    • /
    • v.15 no.2
    • /
    • pp.137-143
    • /
    • 1997
  • Purpose : Radiation pneumonitis is one of the complications caused by radiation therapy that includes a Portion of the lung tissue. The severity of radiation induced pulmonary dysfunction depends on the irradiated lung volume, total dose, dose rate and underlying Pulmonary function. It also depends on whether chemotherapy is done or not. The irradiated lung volume is the most important factor to predict the pulmonary dysfunction in breast cancer Patients following radiation therapy. There are some data that show the irradiated lung volume measured from CT scans as a part of treatment Planning with the tangential beams. But such data have not been reported in Korea. We planned to evaluate the irradiated lung volume quantitatively using CT scans for the breast tangential field and search for useful factors that could Predict the irradiated lung volume Materials and Methods : The lung volume was measured for 25 patients with breast cancer irradiated with tangential field from Jan.1995 to Aug.1996. Parameters that can predict the irradiated lung volume included; (1) the peruendicular distance from the Posterior tangential edge to the posterior part of the anterior chest wall at the center of the field (CLD) ; (2) the maximum perpendicular distance from the posterior tangential field edge to the posterior Part of the anterior chest wall (MLD) ; (3) the greatest perpendicular distance from the Posterior tangential edge to the posterior part of anterior chest wall on CT image at the center of the longitudinal field (GPD) ; (4) the length of the longitudinal field (L). The irradiated lung volume(RV), the entire both lung volume(EV) and the ipsilateral lung volume(IV) were measured using dose volume histogram. The relationship between the irradiated lung volume and predictors was evaluated by regression analysis. Results :The RV is 61-279cc (mean 170cc), the RV/EV is $2.9-13.0\%\;(mean\;5.8\%)$ and the RV/IV is $4.9-29.0\%\;(mean\;12.2\%)$. The CLD, the MLD and the GPD ave 1.9-3.3cm, 1.9-3.3cm and 1.4-3.1cm respectively. The significant relations between the irradiated lung volume such as RV. RV/EV, RV/IV and parameters such as CLD, MLD, GPO, L. $CLD\timesL,\;MLD\timesL\;and\;GPD\timesL$ are not found with little variances in parameters. The RV/IV of the left breast irradiation is significantly larger than that of the right but the RV/EVS do not show the differences. There is no symptomatic radiation pneumonitis at least during 6 months follow up. Conclusion : The significant relationship between the irradiated lung volume and predictors is not found with little variation on parameters. The irradiated lung volume in the tangential held is liss than $10\%$ of entire lung volume when CLO is less than 3cm. The RV/IV of the left tangential field is larger than that of the right but there was no significant differences in RV/EVS. Symptomatic radiation pneumonitis has not occurred during minimum 6 months follow up.

  • PDF

Thymus Size and Its Relationship to Perinatal Diseases; Respiratory Distress Syndrome and Intrauterine Growth Retardation (흉선의 크기와 주산기 질환들과의 관계)

  • Chung, Sun Mi;Kim, Woo Taek
    • Clinical and Experimental Pediatrics
    • /
    • v.45 no.7
    • /
    • pp.855-861
    • /
    • 2002
  • Purpose : Thymus size can be affected by several factors and perinatal diseases can be estimated by its size. The purpose of this study was to search for a relationship between cardiothymic/thoracic(CT/T) ratio and perinatal diseases such as neonatal respiratory distress syndrome(RDS) and intrauterine growth retardation(IUGR) by measuring the width of the cardiothymic shadow at the level of the carina and dividing it by the width of the thorax at the costophrenic angles. Methods : A clinical study was conducted on newborn infants with RDS(n=51), IUGR(n=27), and premature rupture of membranes(PROM, n=48), who were admitted at NICU of Catholic University of Daegu from June 2000 to Oct. 2001. CT/T ratio was measured within six hrs of age, at 2-3 days of age, and at 5-7 days of age. Results : CT/T ratios of RDS group, IUGR group, and PROM group were $0.46{\pm}0.07$, $0.32{\pm}0.04$. $0.36{\pm}0.06$, respectively. CT/T ratios of RDS group within 6hrs of age, at 2-3 days of age, and at 5-7 days of age were $0.43{\pm}0.07$, $0.34{\pm}0.06$, $0.25{\pm}0.04$, respectively. There were statistically significances among the RDS group, the IUGR group, and the PROM group and in the RDS group at different times. Regression for gestational age among three groups was not statistically significant but correlation for gestational age in the entire groups was statistically significant. CT/T ratio between normal spontaneous vaginal delivery and c-section among three groups was not statistically significant. CT/T ratios with dexamethasone-treated group and untreated group was not statistically significant. Conclusion : We concluded that thymus size differed significantly in the perinatal diseases such as RDS and IUGR, and so can be used as an early diagnostic tool for perinatal diseases.

Measures to Implements the Landscape Conservation and Management Urban Heritage Utilizing Public Goods: Focused on the Historic Sites of Seoul (공공재를 활용한 도시유산의 경관 보전 및 관리개선방안 - 서울시 사적을 중심으로 -)

  • Moon, Young-Suk;Jung, Ki-Ho
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.34 no.3
    • /
    • pp.98-114
    • /
    • 2016
  • The this study aimed to expand urban heritage using Public Goods and to suggest the assemblage of urban heritage and urban spaces in order to improve landscape conservation and management scheme of urban heritage exposed to a rapidly changing urban environment. The results obtained in this study were summarized as follows: First, in order to improve understanding of the heritage in urban spaces, urban heritage were illustrated on a 1:1000 map with all the public facilities surrounding it using a cultural heritage conservation map listed on the Cultural Heritage Administration's web site, standards for changing present condition, and a topographic map. Second, the status and changes of urban heritage and surroundings were analyzed using the minutes of Historical Cultural Heritage Division Committee for 10 years from 2005 to 2014 to create a status map of urban heritage. Land uses surrounding the urban heritage were investigated the areas of conservation potential and the places that can enhance the to find out values of urban heritage. Also, a profile was created to examine the site characteristics surrounding urban heritage, and photos were taken at important heritage areas and public facilities in order to record the field. Third, analyzed were the relationship of the distance, location, function, and distribution between urban heritage and public facilities surrounding the heritage. using visual features and moving routes in order to identify their impacts on urban heritage and their functions as potential resources. In addition, the role of Public Goods in urban spaces and the plan for revitalizing surrounding areas asset were examined. Fourth, selections were made on Public Goods that have direct or indirect effects on urban heritage. The role of public asset was investigated through visual, areal, and linear elements. The results were summarized to suggest improvement landscape and management mauser on of urban heritage.

Study on the Application of Ultrasound Traits as Selection Trait in Hanwoo (한우 선발형질로써 초음파 형질의 활용방안 연구)

  • Choi, Tae Jeong;Choy, Yun Ho;Park, Byoungho;Cho, Kwang Hyun;Alam, M;Kang, Ha Yeon;Lee, Seung Soo;Lee, Jae Gu
    • Journal of agriculture & life science
    • /
    • v.51 no.2
    • /
    • pp.117-126
    • /
    • 2017
  • Hanwoo young bulls are selected based on performance test using the weight at 12 months and pedigree index comprising marbling score. Pedigree index was not based on the progeny tested data but the breeding value of the proven bulls; resulting a lower accuracy. The progeny testing of the young bulls was categorized into testing at farm and at the test station. The farm tested data was difficult to compare with those from test station data. Farm tested bulls had different slaughter ages than those for test station bulls. Therefore, this study had considered a different age at slaughter for respective records on ultrasound traits. Records on body weight at 12 months, ultrasound measures at 12 and 24 months(uIMF, uEMA, uBFT, and uRFT), and carcass traits(CWT, EMA, BFT, and MS) were collected from steers and bulls of Hanwoo national improvement scheme between 2008 and 2013. Fixed effects of batch, test date, test station, personnel for measurement, personnel for judging, and a linear covariate of weight at measurement were fitted in the animal models for ultrasound traits. The ranges of heritability estimates of the ultrasound traits at 12 and 24 months were 0.21-0.43 and 0.32-0.47, respectively. Ultrasound traits at 12 and 24 months between similar carcass traits was genetically correlated at 0.52-0.75 and 0.86-0.89, respectively.

Lung Uptake of $^{99m}Tc-sestamibi$ during Routine Gated Exercise SPECT Imaging : Comparison with Left Ventricular Ejection Fraction and Severity of Perfusion Defect (일상적인 운동 부하 게이트 심근 관류 SPECT에서 $^{99m}Tc-sestamibi$ 폐섭취 : 좌심실 구혈률과 관류 결손 정도와의 비교)

  • Jeong, Shin-Young;Lee, Jae-Tae;Bae, Jin-Ho;Ahn, Byeong-Cheol;Lee, Kyu-Bo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.2
    • /
    • pp.83-93
    • /
    • 2003
  • Background: Lung-to-heart uptake ratio (LHR) in $^{201}Tl-chloride$ myocardial perfusion scan is believed to be a reliable marker for left ventricular (LV) dysfunction, but the clinical value of LHR is controversial for $^{99m}Tc-MIBI$ imaging. Furthermore, most of results suggesting lung uptake of $^{99m}Tc-MIBI$ as a potential marker for LV dysfunction used immediate post-stress images, instead of routine images acquired 1 hour after tracer injection. The goal of our study was to investigate whether LHR evaluated with routine gated $^{99m}Tc-MIBI$ imaging can reflect the degree of perfusion defect or left ventricular performance. Subjects and Methods: 241 patients underwent exercise $^{99m}Tc-MIBI$ myocardial SPECT were classified into normal myocardial perfusion (NP, n=135) and abnormal myocardial perfusion (AP, n=106) group according to the presence of perfusion defect. LHR was calculated from anterior projection image taken at 1-hour after injection. Two legions of interest (ROIs) were placed on left lung above LV and on myocardium showing the highest radioactivity. Subjects were classified by left ventricular ejection fraction (LVEF), as Gr-I: >50%, Gr-II: 36-50%, Gr-III: <36% and by summed stress score (SSS), as Gr-A: <4, Gr-B: 4-8, Gr-C: 9-13, Gr-D: >13, LHR was compared among these groups. Results: In NP group(n=135), LHR, were higher in men than women ($men:\;0.311{\pm}0.03,\;women:\;0.296{\pm}0.03,\;p<0.05$). Significant difference, in LHR were found between NP and AP groups both for men and women ($men:\;0.311{\pm}0.03\;vs\;.\;0.331{\pm}0.06,\;women:\;0.296{\pm}0.03\;vs.\;0.321{\pm}0.07.\;p<0.05$). There were weak negative correlation between LHR and LVEF (r=-0.342, p<0.05) and weak positive correlation between LHR and SSS (r=0.478, p<0.05) in men, but not in women (LVEF: r=-0.279, p=0.100, SSS: r=0.276, p=0.103). Increased LHR was defined when for more than mean + 2SD value ($men{\geq}0.38,\;women{\geq}0.37$) of the LHR of the subject with normal perfusion. Increased LHR were observed more frequently in subjects with lower LVEF (Gr-I: 11.1%, Gr-II: 27.0%, Gr-III: 35.4%, p<0.05) and higher SSS(Gr-A: 14.0%, Gr-B: 5.7%, Gr-C: 18.2%, Gr-D: 40.7%, p<0.05). Conclusions: LHRs obtained from routine $^{99m}Tc-MIBI$ gated SPECT images were weakly correlated with LVEF and perfusion defect. Although significant overlaps were observed between normal and abnormal perfusion group, LHRs could be used as an indirect marker of severe perfusion defect or reduced left ventricular function.