• 제목/요약/키워드: 간이 측정기

Search Result 263, Processing Time 0.031 seconds

Methods of temperature measurement of medium in bottle during sterilization (병재배 배지살균 시 배지내부의 실시간 온도측정 방법)

  • Cheong, Jong-Chun;Jhune, Chang-Sung;Lee, Chan-Jung;Oh, Jin-A;Shin, Pyeong-Gyun
    • Journal of Mushroom
    • /
    • v.9 no.2
    • /
    • pp.74-79
    • /
    • 2011
  • This study was carried out to develop a method related to measuring the temperature of sterile medium in bottle cultivation. When the medium is sterilized, the device is able to be inserted inside of the medium and the temperature can be directly measured in real time although high temperature and pressure are detected in the sterilization. This device can be able to measure the sterilization temperature in short intervals inside of autoclave and medium used in bottle cultivation. As the method were applied to the field cultivation of mushroom, we could produce mushroom in consistent manner through the optimum sterilization of the medium.

A Study on Quality Management Activities and Employee Trusts: Based on Small Venture Companies (품질경영활동과 조직원 신뢰간의 관계에 관한 연구: 중소벤처기업을 대상으로)

  • Lee, Byung-Ok;Lee, Joo-Heon
    • 한국벤처창업학회:학술대회논문집
    • /
    • 2010.08a
    • /
    • pp.5-18
    • /
    • 2010
  • In this article, we try to study the relationship among quality management activities, employee trusts, and employee satisfactions in small venture companies in Korea. Based on the previous studies, we build a couple of hypotheses about communication, process management, business policies, innovative changes, employee trust and employee satisfaction. From our empirical study, we find that communication and innovative changes have an positive effect on employee trust. Also, employee satisfaction is positively influenced by employee trust. Our study provides the following implications for organization management. First, for employee satisfaction, in an organization, it is very important to build employee trusts among higher managements, firms, business processes, evaluations, and employees. Second, in order to build employee trusts, our study shows that improving communications among employees and customers and having continuous innovative changes such as improving current business processes, problem solving, establishing standards and maintaing high productions are important.

  • PDF

OTFT 소자 성능 향상을 위한 고품질 3-Aminopropyltriethoxysilane 자기조립단분자막의 제작

  • Choe, Sang-Il;Jeong, Yun-Sik;Kim, Gyeong-Su;Bae, Yeong-Min;Kim, Seong-Su
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.260-260
    • /
    • 2010
  • OTFT소자는 각 박막계면간의 접촉성에 따라 그 성능이 좌우 된다는 것은 널리 알려진 사실이다. 즉 박막계면간의 접촉성 저하는 계면간의 결함을 형성하여 OTFT소자 성능을 저하시킨다. 이러한 결함을 고품질의 자기조립단분자막을 제작함으로써 박막계면간 결함을 최소화 할 수 있다. 이러한 고품질의 자기조립단분자막 형성은 박막계면간의 결함을 최소화 하기때문에 고성능OTFT소자 제작시 박막계면간 접촉성 향상에 효율적으로 적용할 수 있을것이다. 이 논문에서는 계면간의 접촉성 향상을 위해 실리콘 웨이퍼 위에 3-Aminoproplytriethoxtsilane과 용매인 무수톨루엔을 이용하여 고품질의 자기조립단분자막을 제작 하였으며 고품질을 자기조립단분자막 성장 조건을 찾기 위해 엄격한 수분조절 및 APS농도, 담근시간, 온도를 조절하여 각기 다른 조건의 샘플을 제작하였다. 또한 APS성장 분포를 알기위하여 접촉각 측정기를 이용하여 접촉각을 측정 하였고 AFM 이용하여 실리콘 웨이퍼에 생성된 박막의 균질도를 측정하였다. 그 결과 APS농도(33%) 24시간 $25^{\circ}C$, APS농도(33%) 24시간 $70^{\circ}C$, APS농도(33%) 72시간 $25^{\circ}C$, APS농도 (33%) 72시간 $70^{\circ}C$ 샘플이 기존에 알려진 APS 접촉각인 $19^{\circ}C{\sim}21^{\circ}C$ 접촉각이 나왔으며 AFM 이미지 또한 높은 균질도를 보였다. 이 결과 고품질의 APS단분자막은 농도와 시간 그리고 온도에 영향은 받으며 이렇게 완성된 단분자막은 높은 균질도를 가지게 된다. 현재 실험을 통해 얻어진 고품질의 자기조립단분자막 성장 조건을 이용하여 OTFT소자 제작하고 있으며 고품질의 자기조립단분자막 형성에 의해 결함을 최소화 하므로써 박막계면간 옴성결합을 형성하여 OTFT소자의 성능 향상이 기대되어 진다.

  • PDF

A Study on the Construction of Multipurpose Observatory for Integrated Measurement of Discharge, Sediment Discharge, and Water Quality (유량·유사량·수질 통합 계측을 위한 다목적 관측소 구축 연구)

  • Baek, Jongseok;Park, Yongwoon;Sung, Janghyun;Son, Geunsoo;Oh, Dongheon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.251-251
    • /
    • 2022
  • 물관리 일원화로 인해 높아지는 국민의 관심과 기대에 따라 통합 물관리 기술의 제고가 필요하다. 환경부의 수문조사기본계획에서는 수량·수질·수생태 통합관리를 위한 기초정보 생산, 자동화를 확보하는 방향으로 측정·조사망 개선 및 통합 관리 등이 명시되어 있는데, 현재의 수량과 수질분야 계측은 기존의 관측망과 각 분야별 계측특성으로 인해 별도의 관측망과 관측 체계로 운영되고 있다. 이에 첨단 계측시스템의 구축을 통해 실시간 유량자료를 생산하고 있는 환경부의 자동유량측정시설 인프라를 이용하여 추가적인 수질 계측기의 설치와 자료전송시스템의 개선을 통해 유량·유사량·수질을 통합 계측할 수 있는 다목적 관측소 구축 연구를 수행하였다. 자동유량측정망과 수질측정망을 검토하여 중복측정이 되지 않도록 낙동강 본류의 구미시(구미대교) 지점을 선정하였고, 대상지점의 현장조사 및 하상단면 측량, 수질측정 등을 검토하여 기존의 자동유량측정시설에 다목적 측정이 가능하도록 인프라를 구축하였다. 유사량은 기존에 설치된 자동유량측정시설의 초음파 유속계에서 계측되는 초음파산란도와 부유사농도의 관계식 개발을 통해 실시간 유사량 자료를 생산할 수 있고, 수질자료는 자동수질측정망에서 활용하고 있는 다항목 수질측정기를 설치하여 수온, 전기전도도, 용존산소, 탁도, 수소이온농도 등의 자료를 생산할 수 있다. 다목적 관측소의 구축은 기존 인프라를 활용할 수 있어 항목별 개별적인 관측소 구축에 비해 저비용 설치가 가능하고, 자료의 통합 관리에 있어 효율적일 수 있다. 금년도 홍수기 이전 시스템의 구축이 완료될 예정이고, 추후 다목적 관측소의 운영을 통해 유량, 유사량, 수질자료의 통합 생산 및 처리과정의 개선을 수행하여 통합 물관리에 일조할 수 있을 것으로 기대한다.

  • PDF

Machining Tolerance of Various Implant Systems and their Components (치과용 임플란트 시스템의 기계적 가공오차에 관한 연구)

  • Kim, Hyeong-Seob;Kwon, Kung-Rock;Han, Jung-Suk
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.1
    • /
    • pp.57-65
    • /
    • 2008
  • Purpose: Misfit of implant components was very important in terms of prosthodontics. they has been linked to prosthetic complications such as screw loosening and fracture. Although there are many results about rotational freedom or machining tolerance between fixture and abutments, the data about domestic implant systems are lacking. The aim of this in vitro study was to evaluate the rotational freedom of domestic external and internal connection implant systems between their fixtures/anlaogs and abutments comparing imported systems. Materials and Methods: Rotational freedom between abutments and fixtures/analogs was investigated by using digitalized rotational angle measuring device. (1) 1 domestic external connection system(Neobiotec) and 2 imported external connection systems(Nobel Biocare, Anthorgyr), (2) 1 domestic internal connection system(Dentium) and 4 imported external connection systems(Nobel Biocare, Anthorgyr, Straumann, Frident Dentsply), and (3) 1 domestic zirconia external connection abutment(ZirAce) were evaluated. Each group has 3 samples. Mean values for each group were analyzed. Results: The differences relative to rotational freedom between domestic and imported implant systems were observed but domestic external connection implant system showed about 2.67 degrees(in case of fixture) and internal connection system showed about 4.3 degrees(in case of fixture). Domestic zirconia abutment showed less than 3 degrees of rotational freedom in a situation where the abutment was connected to an implant fixture egardless of domestic or imported systems. Conclusion: Newly developed digitalized rotational angle measuring device has high measuring resolution. The rotational freedom of domestic implant systems were similar to imported implant systems.

Study of morphology on the Oxidation and the Annealing of High Burn-hp $UO_2$ Spent Fuel (고연소도 사용후 핵연료의 가열산화와 고온가열을 통한 미세조직 변화고찰)

  • Kim Dae Ho;Bang Jae Geun;Yang Yong Sik;Song Keun Woo;Lee Hyung Kwon;Kwon Hyung Moon
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.3 no.4
    • /
    • pp.301-307
    • /
    • 2005
  • The morphology of the high burnup $UO_2$ spent fuel, which was oxidized and annealed in a PIA (Post Irradiation Annealing) apparatus, has been observed. The high burnup fuel irradiated in Ulchin Unit 2, average rod burnup 57,000 MWd/tU, was transported to the KAERI's PIEF. The test specimen was used with about 200 mg of the spent $UO_2$ fuel fragment of the local burnup 65,000 MWd/tU. This specimen was annealed at $1400^{\circ}C$ for 4hrs after the oxidation for 3hrs to grain boundary using the PIA apparatus in a hot-cell. In order to oxidize the grain boundary, the oxidation temperature increased up to $500^{\circ}C$ and held for 3hrs in the mixed gas (60 ml He and 100 ml STD-air) atmosphere. The amount of 85Kr during the whole test process was measured to know the fission gas release behavior using the online system of a beta counter and a gamma counter. The detailed micro-structure was observed by a SEM to confirm the change of the fuel morphology after this test. As the annealing temperature increased, the fission products were observed to move to the grain surface and grain boundary of the $UO_2$ matrix. This specimen was re-structured through the reduction process, and the grain sizes were distributed from 5 to $10\;{\mu}m$.

  • PDF

Analysis about the reliability of sobriety testing (focused on the Blood-Breath Ratios) (음주 측정의 신뢰도에 대한 분석 (혈액호흡 분배비율을 중심으로))

  • Lee, Won-Young;Ko, Myoung-Soo
    • Journal of Korean Society of Transportation
    • /
    • v.26 no.6
    • /
    • pp.49-60
    • /
    • 2008
  • The aim of this study was to evaluate the variability of the blood.breath ratio (BBR) value and to rationalize the determination of ethanol in breath for evidential sobriety testing. In the experiment forty eight healthy persons, 24 men and 24 women, took part. The experiment included the experimental condition such as sex(2),the type of alcoholic beverage(2; soju, whisky), the type of food(2;kimchi stew, pork belly) and the amount of ethanol consumed(2; 0.35g/kg, 0.70g/kg, based on body weight ) according to 24 factorial design by orthogonal arrays. Breath and blood sample were taken each 8 times and 5 times after the end of drinking. The blood and breath alcohol measurements were highly correlated (r = 0.973). The Results of four way analyses of variance revealed a significant 'the type of food' effect for maximum BrAC (F (1, 43) =5.1, pp<.029), but no significant effect in the type of alcoholic beverage and sex. The overall blood/breath ratio (${\pm}$ SD) was 2295${\pm}$403 and the 95% confidence interval were 1489 and 3101. In spite of these variations, at this time, it seems to be reasonable that apply 2100:1 conversion factor to breathalyzers, because most of the subjects showed the blood.breath ratio of over 2100:1 at least 30 minutes or more passed from the time of drinking as shown in this study.

Effects of Chest Compression Quality between Rescuer's Simplified Verbal-Order Method and Continued Verbal-Order Method during Cardiopulmonary Resuscitation (심폐소생술 시 구조자의 간소화된 구령방법과 연속된 구령방법 간의 가슴압박 질 효과)

  • Baek, Hong-Seok;Park, Sang-Sub
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.4
    • /
    • pp.320-330
    • /
    • 2013
  • The purpose of this study is to increase efficiency of CPR through comparing the chest-compression quality between rescuer's simplified verbal order method and the continued verbal order method by utilizing voice meter during CPR. Subjects were 89 people(45 people for the experimental group, 44 people for the control group) who completed the 15-week CPR curriculum as undergraduates for the department of Emergency Medical Technology in C Province and were carried out by being randomly extracted. The group division was set for the experimental group as the group with the simplified verbal order and for the control group as the group with the continued verbal order. The period of measurement was progressed primarily(November 10, November 28, 2011) and secondarily(September 3-September 4, 2012). An analysis was used SPSS WIN 12.0 program. As a result of research, as for the implementation of appropriate chest compression(time, %), the quality was higher(p<.05) in the experimental group(102.86 times, 67.79%) than the control group(85.31 times, 55.84%). As a result of research, the chest compression(time, %) in the experimental group(102.86 times, 67.79%) had the higher effect of chest compression quality(p<.05) than the control group(85.31 times, 55.84%). On the other hand, the operation of weak chest compression(time) was higher in control group(61.13 times) than experimental group(35.54 times). The proper chest compression was shown(p<.05) in men of the experimental group as for gender and in over 60kg of the experimental group as for weight.

Analysis of causal factors and physical reactions according to visually induced motion sickness (시각적으로 유발되는 어지럼증(VIMS)에 따른 신체적 반응 및 유발 요인 분석)

  • Lee, Chae-Won;Choi, Min-Kook;Kim, Kyu-Sung;Lee, Sang-Chul
    • Journal of the HCI Society of Korea
    • /
    • v.9 no.1
    • /
    • pp.11-21
    • /
    • 2014
  • We present an experimental framework to analyze the physical reactions and causal factors of Visually Induced Motion Sickness (VIMS) using electroencephalography (EEG) signals and vital signs. We studied eleven subjects who are voluntarily participated in the experiments and conducted online and offline surveys. In order to simulate videos including global motions that could cause the motion sickness, we extracted global motions by optical flow estimation method from hand-held captured video recordings containing intense motions. Then, we applied the extracted global motions to our test videos with action movies and texts. Each genre of video includes three levels of different motions depending on its intensity. EEG signal and vital sign that were measured by a portable electrocorticography device and an electronic monometer in real time while the subjects watch the videos including ones with the extracted motions. We perform an analysis of the EEG signals using Distance Map(DM) calculated by correlation among each channel of brain signal. Analysis using the vital signs and the survey results is also performed to obtain relationship between the VIMS and causal factors. As a result, we clustered subjects into three groups based on the analysis of the physical reaction using the DM and the correlation between vital sign and survey results, which shows high relationships between the VIMS and the intensity of motions.

A Study on IoT and Cloud-based Real-time Bridge Height Measurement Service (사물인터넷과 클라우드 기반의 실시간 교량 높이 계측 서비스 연구)

  • Choi, Cha-Hwan;Cheon, Young-Man;Jeong, Seung-Hun;Tcha, Dek-Kie;Lee, Young-Jae
    • Journal of Cadastre & Land InformatiX
    • /
    • v.47 no.2
    • /
    • pp.145-157
    • /
    • 2017
  • Currently, the height of ships that can pass under Busan Harbor Bridge is limited to 60m or shorter, so that large-sized ships of 60m or taller cannot use Busan Harbor international passenger terminal. Accordingly, this study has developed a service which measures continuously the change of bridge height by water level changes and provides such in real-time for safe bridge passage of large-sized ships of 60m or taller. The measurement system comprised of high-precision laser distance measurement device, GPS sensor, optical module, and damping structure is used to measure the bridge height change according to tide level changes, and the measured information is provided in real-time through cloud-based mobile app. Also, in order to secure objective bridge height data for changes to height limits and navigation supports, the observation data was analyzed and forecast model was drawn. As a result, it became an objective evidence to revise the passage height rules of the Busan Port Bridge from 60 meters to 63 meters.