• Title/Summary/Keyword: 간이 진단

Search Result 3,190, Processing Time 0.038 seconds

Catenary Measurement System for Real-Time Automated Diahnosis (실시간 자동화 진단을 위한 전차선 검측시스템)

  • Kim, Jeong-Yeon;Park, Jong-Gook;Lee, Byeong-Gon;Hong, Hyun-Pyo
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.1020-1026
    • /
    • 2011
  • In this paper, we propose a method that measures the height and stagger of an catenary using the laser profile images. One line laser and area scanner CCD cameras are used. To quickly and accurately extract, from a photographed image, the area of the overhead line on which the line laser is shone, we consider the established fact that the catenary is the lowest among the electric wires. Here we are solving the the distance to the catenary if we know the distance the camera is from the ground and the angle of the catenary in the field of view. The angle will be related to the number of pixels in the image. This pixels per degree is a constant for the camera. Also, because of the different pixel resolution of the camera according to the overhead line position, we compensate the measurement result through camera calibration.

  • PDF

An Implementation of Realtime Remote-Monitoring System for Distributed Photovoltaic Power Plants (분산형 태양광 발전 시스템을 위한 실시간 원격 모니터링 시스템 구현)

  • Kim, Chang-Joon;Kim, Jung-Ki;Jang, Kyung-Sik
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.10
    • /
    • pp.2450-2456
    • /
    • 2015
  • In this paper, we propose a real-time remote monitoring system for distributed solar power generation system. The proposed system consists of PVC, UTC, OTC and monitoring server. PVC collects the operational information from the PV's inverter via serial interface. The sensing data is transmitted to the server by wireless communications and stored in the DB server. The PV's status is monitored via UTC, and the operating of PVC and UTC are managed by OTC. In addition, by providing information about the power generated by PV system and failure diagnosis in real time, the proposed system shows the possibility of reducing the maintenance costs and improved failure recovery time.

Task Contents, Organizational Structures and Work Relations of ICT Departments in Korean Local Governments (광역자치단체 정보화 조직 역량 분석과 발전모델 제안: 업무, 구조, 관계를 중심으로)

  • Cho, Hee-Jin;Jang, Yong-Suk;Jeong, Myung-Eun
    • Informatization Policy
    • /
    • v.23 no.3
    • /
    • pp.84-116
    • /
    • 2016
  • This paper explores alternative organizational models for ICT units of local governments, while analyzing the task contents, organizational structures and work relations of ICT departments in 17 Korean metropolitan provinces. We employed both quantitative and qualitative methods including in-depth interview, open-ended survey, and hard data analyses to collect a wide variety of information on organizational performance, human resource development, and task characteristics of ICT units. As strategies to enhance task contents, organizational structures and work relations of ICT departments, we suggest four ideal ICT organizational models for local governments: Relation Model, Resource Model, Curation Model and Creation Model.

Shear Performance Evaluation of the Joint between Hollow Core Slabs (Hollow core 슬래브 간 접합부의 전단저항성능 평가)

  • Hong, Geon-Ho;Baek, Jong-Sam;Park, Hong-Gun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.4
    • /
    • pp.94-101
    • /
    • 2010
  • Recently, the interest of precast concrete is increased for rapid construction in construction fields. Experimental study about the shear performance of the joint between hollow core slabs which have internal core to reduce their weight was performed. Main test variables were thickness of the topping concrete and existence of the wiremesh. Total 8 specimens including 4 in-plane shear and 4 out of plane shear were tested. Test results were analyzed in terms of cracking load, failure load, failure aspect, stiffness and ductility, and compared its design load to develop optimum design details. Test results indicated that the shear performance of the non-shrinkage mortar specimen was similar to that of 30mm thickness topping concrete specimen, and the effect of wiremesh reinforcement did not affect the failure load or stiffness of the specimens but the increase of ductility. And this paper presents the comparison results of the test results and design load to provide the optimum detail of the joint design between the hollow core slabs.

Prediction of Failure Mode Under Static Loading in Long Span Bridge Deck Slabs by FEM (유한요소해석에 의한 장지간 바닥판의 정적파괴형태 예측)

  • Park, Woo Jin;Hwang, Hoon Hee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.4
    • /
    • pp.52-59
    • /
    • 2012
  • An analytical model is presented to predict the static behavior of the long-span prestressed concrete bridge deck(the long-span PSC deck). The finite element analysis is performed and the results are compared with that of the previous experimental test. The load-deflection relationship curves by FEM are in good agreement with the results reported in the previous study. The failure mode of all test specimens is predicted by the punching shear in this study. It is also observed in the previous experimental test. The main objective of this paper is presenting supportive method to predict static behavior of the long-span PSC deck slab. It is not simulating the punching shear behavior graphically.

Liver Abscess Associated with Maternal Perinatal Infection in a Premature Infant (주산기 모체 감염과 미숙아 간농양 1례)

  • Lee, Ju-Hee;Seo, Bong-Ok;Seo, Eun-Sun;Kim, Sung-Mi;Kim, June-Hyoung
    • Neonatal Medicine
    • /
    • v.15 no.1
    • /
    • pp.105-110
    • /
    • 2008
  • Neonatal liver abscesses are rare, carry a high mortality rate, and are difficult to diagnose. The diagnosis of liver abscesses in the neonate cannot be established from the clinical presentation alone. Risk factors for liver abscesses in neonates are maternal infection, sepsis, umbilical venous catheterization, omphalitis, and necrotizing enterocolitis. In this report, we describe a preterm infant (32 weeks, 1,580 g) who presented with abdominal distension, respiratory difficulties, and a persistent inflammatory response in spite of broad spectrum antibiotic treatment; a large (6${\times}$5 cm) solitary pyogenic liver abscess was identified at 9 days of age. It appeared that the liver abscess had originated in the uterus and umbilical venous catheterization facilitated its spread. Percutaneous drainage under abdominal ultrasound guidance was performed and prolonged antibiotics were treated for 5 weeks, effecting a cure.

An Energy-Dissipation-Ratio Based Structural Health Monitoring System (에너지소산률을 이용한 구조물의 건전도 모니터링에 관한 연구)

  • Heo, Gwang-Hee;Shin, Heung-Chul;Shin, Jae-Chul
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.8 no.1
    • /
    • pp.165-174
    • /
    • 2004
  • This research develops a technique which uses energy dissipation ratio in order to monitor the structural health on real time basis. For real-time monitoring, we employ the NExT and the ERA which enable us to obtain real-time data. Energy dissipation ratio is calculated from those data only with the damping and natural frequency of the structure, and from the calculated values we develop an algorithm (Energy dissipation method) which decides the damage degree of structure. The Energy dissipation method developed in this research is proved to be valid by comparison with other methods like the eigenparameter method and the MAC. Especially this method enables us to save measuring time and data which are the most important in real-time monitoring, and its use of the ambient vibration also makes it easy to monitor the whole structure and its damage points.

EEG-based Real-time Automated Analysis System Depression (뇌파 기반 실시간 우울증 자동 분석 시스템)

  • Jeon, Chang-Hyun;Shin, Dong-Min;Shin, Dong-Kyoo;Shin, Dong-Il
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2014.04a
    • /
    • pp.1001-1004
    • /
    • 2014
  • IT 기술과 의료 기술이 발전함에 따라 뇌파를 이용한 많은 연구들이 진행되고 있다. 컴퓨터로 사용자가 뇌파를 측정하고, 측정된 뇌파를 실시간으로 모니터링 할 수 있는 고속 데이터 처리 알고리즘을 소개하고, 측정된 뇌파를 통하여 우울증을 진단할 수 있는 시스템을 구현하였다. 특히 실시간 뇌파지표 분석을 통하여 뇌파의 기본파형이 분류되고, 분류된 신호에서 개발된 알고리즘에 따라 주의/이완/집중/우울의 4가지 지표가 실시간으로 도출된다.

Detection of Mycobacterium Tuberculosis by In Situ Hybridization (조직내교잡법을 이용한 결핵균의 검출)

  • Park, Chang-Soo;Kim, Young-Chul;Lee, Jee-Shin;Jung, Jong-Jae;Kim, Doo-Hong;Kim, Jin
    • Tuberculosis and Respiratory Diseases
    • /
    • v.48 no.5
    • /
    • pp.699-708
    • /
    • 2000
  • Background : A presumptive histopathologic diagnosis of tuberculosis is commonly based on the finding of acid-fast bacilli upon microscopic examination of a diagnostic specimens. Although this traditional histochemical staining method is satisfactory, it is time-consuming and not species-specific. For more specific assessment, in situ hybridization assay with oligonucleotide probes is introduced. Methods : The human surgical specimens were obtained from tuberculosis patients, and experimental specimens were made by injecting cultured M. tuberculosis organisms into fresh rat liver. Oligonucleotide probes complementary to ribosomal RNA portion were synthesized and labeled with multiple biotin molecules. For a rapid detection, all procedures were carried out using manual capillary action technology on the Microprobe staining system. Results : The in situ hybridization assay produced a positive reaction in experimental specimens (80-90% sensitivity) after pepsin-HCl pre-treatment for a good permeabilization of probes, but reliable result was not obtained from human surgical specimens. Conclusion : It is, therefore, suggested that biotin-labeled oligonucleotide probes have considerable potential for identification and in situ detection of M. tuberculosis but, there are some barriers to overcome for the diagnostic use of this method.

  • PDF

Usefulness Evaluation of Low-dose CT for Emphysema : Compared with High-resolution CT (폐기종에 대한 저선량 CT의 유용성 평가: 고해상도 CT와 비교)

  • Lee, Won-Jeong
    • Journal of radiological science and technology
    • /
    • v.39 no.3
    • /
    • pp.329-336
    • /
    • 2016
  • The purpose of this study was to evaluate the usefulness of low-dose CT (LDCT) for emphysema compared with high-resolution CT (HRCT). Measurements of radiation dose and noise were repeated 3 times in same exposure condition which was similar with obtaining HRCT and LDCT images. We analysed reading results of 146 subjects. Six images per participants selected for emphysema grading. Emphysema was graded for all 6 zones on the left and right sides of the lungs by the consensus reading of two chest radiologists using a 4-point scale. Between the HRCT and LDCT images, diagnostic differences and agreements for emphysema were analyzed by McNemar's and unweighted kappa tests, and radiation doses and noise by a Mann-Whitney U-test, using the SPSS 19.0 program. Radiation dose from HRCT was significantly higher than that of LDCT, but the noise was significantly lower in HRCT than in LDCT. Diagnostic agreement for emphysema between HRCT and LDCT images was excellent (k-value=0.88). Emphysema grading scores were not significantly different between HRCT and LDCT images for all six lung zones. Emphysema grading scores from LDCT images were significantly correlated with increased scores on HRCT images (r=0.599, p < 0.001). Considering the tradeoff between radiation dose and image noise, LDCT could be used as the gold standard method instead of HRCT for emphysema detection and grading.