• Title/Summary/Keyword: 간부 골절

Search Result 51, Processing Time 0.02 seconds

A case study of radial nerve injury associated with humerus shaft fracture (상완골 간부 골절에 동반된 요골신경손상에 대한 치험 1례)

  • Lee, Jae-Eun;Lee, Jung-Min;Oh, Min-Seok
    • Journal of Haehwa Medicine
    • /
    • v.23 no.1
    • /
    • pp.157-166
    • /
    • 2014
  • Objective : The purpose of this study is to report the patient with radial nerve injury associated with humerus shaft fracture, who was improved by Korean medical treatments. Methods : The patient was treated by Jungsongouhyul pharmacopuncture, electrical stimulation therapy, physical therapy, and herbal medicine according to "Locating Yang brightness meridians" theory. Coding result, Numeric rating scale(NRS) and digital grip dynamometer were used to evaluate the wrist drop, numbness of fingers and grip power. Results : The patient showed the first sign of recovery after 6 weeks from onset. After 9 weeks from onset, the patient could perform delicate manual activity. Grip power showed noticeable improvement as well as coding result and NRS. Conclusions : The results suggest that providing Korean medical treatments according to "Locating Yang brightness meridians" theory is a good method for treating radial nerve injury associated with humerus shaft fracture. But further studies are required to concretely prove the effectiveness of this method for treating radial nerve injury associated with humerus fracture.

Arthroscopic Reduction and Fixation of an Anterior Cruciate Ligament Avulsion Fracture From the Tibial Eminence Using Bioabsorbable Pins - Technical Note - (생흡수성 핀을 이용한 소아 경골 과간부 견열 골절의 관절경적 정복 및 고정 방법 - 수술 술기 -)

  • Lee, Su-Chan;Yang, Il-Soon;Seo, Hee-Soo
    • Journal of the Korean Arthroscopy Society
    • /
    • v.13 no.2
    • /
    • pp.183-187
    • /
    • 2009
  • Purpose: We describe a new and simple technique for arthroscopic fixation of tibial intercondylar eminence avulsion fracture using bioabsorbable pins in skeletally immature patients. Operative Technique: Diagnostic knee arthroscopy is performed using anterolateral and anteromedial portals. Fracture debris and blood clot are debrided to expose the injured site well. The fragment is reduced with the probe and fixed temporarily with a 1.1-mm diameter K-wire that is inserted percutaneously from the anterosuperior aspect of the knee joint. The drill guide is introduced into the joint and the fragment is secured by bioabsorbable, poly-p-dioxanone 1.3-mm pins inserted from different angles. The pins are 40 mm in length. The knee is placed in a long leg cast in extension for 4 weeks to assure that full extension is obtained. Conclusion: Arthroscopic fixation of an tibial intercondylar eminence avulsion fracture using bioabsorbable pins is not a technically demanding, suitable method that ensures fracture healing and restores the stability of the joint.

  • PDF

Treatment of the Tibia Shaft Fractures with Ender Nails (Ender Nail을 이용한 경골간부 골절의 치료)

  • Kim, In-Ki;Lee, Dong-Chul;Seo, Jae-Sung;Ahn, Myun-Whan;Kim, Se-Dong;Ahn, Jong-Chul
    • Journal of Yeungnam Medical Science
    • /
    • v.9 no.1
    • /
    • pp.130-136
    • /
    • 1992
  • Fractures of the tibial shaft are the most common among the long bone fractures, and have much difficulty in treatment due to their enumerous complications. Thirty patients with fractures of the tibial shaft were treated with Ender nails under the image intensifier at the Department of Orthopedic Surgery, Yeungnam University Hospital from December 1986 to November 1991. The following results were observed. 1. The average age was 37.3 years and the number of male was three times of the female. The most common cause was traffic accident. 2. Twenty cases out of thirty one were closed fractrure and the remaining 11 were open. The comminuted and segmental fractures were 18(57.7%) in number and the most common fracture site was the middle one third(53%). 3. Average interval from injury to operation was 7.6 days and 19 cases showed associated injuries. 4. The mean duration of the bone union was 18.9 weeks and 2 cases showed the delayed union. 5. Twelve complications were noted such as shortening, varus deformity, delayed union, ankle motion limitation, nail irritation, and soft tissue infection.

  • PDF

Surgical Management of Comminuted Midshaft Clavicle Fractures Using Reconstruction Plate and Circumferential Wiring: Does the Circumferential Wiring Interfere with the Bone Union? (쇄골 간부 복합 골절에서 재건 금속판 및 환 강선을 이용한 수술적 치료: 환 강선이 골 유합을 방해하는가?)

  • Kim, Kyung-Tae;Shin, Chung-Shik;Park, Young-Chul;Kim, Dong-hyun;Kim, Min-Woo
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.3
    • /
    • pp.245-252
    • /
    • 2021
  • Purpose: This study examined the radiological and clinical outcomes of internal fixation using a reconstruction plate and 21G circumferential wire in comminuted midshaft clavicular fractures. Materials and Methods: A retrospective cohort study was performed on 51 patients between 2005 and 2019. Thirty-two patients underwent internal fixation with a reconstruction plate and a 21G circumferential wire with minimal soft tissue detachment, and 19 patients underwent surgery without a wire. The patients were assessed with the radiographic parameters, the University of California at Los Angeles (UCLA) score, and the visual analogue scale (VAS) pain score. Based on this, patients who operated without a circumferential wire were set as the control group, and the differences in bone union between the two groups were compared. Results: Thirty-two patients were followed-up for an average of 65 weeks, and 19 patients in the control group were followed-up for an average of 56 weeks. The radiological evaluation confirmed the anatomical reduction and bone union in all 32 patients. No case of nonunion was present. The UCLA score was 32.38 on average and 33.11 in the control group (p=0.395). The VAS score was 1.00 on average and 0.84 in the control group (p=0.668). A significant difference in the bony union time was observed between the group who underwent internal fixation with a reconstruction plate and a 21G circumferential wire with minimal soft tissue detachment, and the control group (p=0.015). On the other hand, there was no statistical significance when other variables were controlled (p=0.107). Conclusion: For displaced midshaft clavicular fractures, internal fixation using a reconstruction plate and 21G circumferential wire maintained accurate anatomical reduction. The satisfactory clinical and radiological results mean that internal fixation using a reconstruction plate and 21G circumferential wire may be a good option for surgical treatment.

Factors Affecting the Period of Bone Union When Treating Femoral Fractures with a Retrograde Intramedullary Nail (역행성 골수강 내 금속정을 이용한 대퇴골절의 치료 시 골유합 기간에 영향 미치는 인자)

  • Kim, Bum-Soo;Kim, Seong-Tae;Shin, Seungyup;Jeon, Seong Man
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.4
    • /
    • pp.326-333
    • /
    • 2021
  • Purpose: A retrograde intramedullary nail is commonly used to treat femoral shaft and distal femur fractures. The authors analyzed the treatment results and the factors affecting the period of bone union for thirty-five patients treated with a retrograde intramedullary nail. Materials and Methods: Thirty-five patients who could be followed up for more than twelve months after the treatment with retrograde intramedullary nailing were analyzed retrospectively. The treatment results and the relationship between the period of bone union and the patient's age, sex, comminution of fracture, presence of open fracture, location of the fracture, and accompanying fractures were evaluated. Results: The average bone union time was 4.50 months. The period of bone union was unaffected by the age, sex, location, and presence of open fractures but was affected by the presence of comminution and accompanying fractures. Conclusion: Retrograde intramedullary nailing is effective for distal and shaft of fractures of the femur. The period of bone union is affected by the presence of comminution and accompanying fractures.