• Title/Summary/Keyword: 가철성 장치

Search Result 76, Processing Time 0.04 seconds

Evaluation of clinical status of removable partial dentures (가철성 국소의치의 임상적 상태에 대한 평가)

  • Yang, Dong-Seok;Cho, Uk;Jeong, Chang-Mo;Jeon, Young-Chan;Yun, Mi-Jung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.3
    • /
    • pp.320-327
    • /
    • 2009
  • Statement of Problem: Although many efforts have been continually made to estimate long term prognosis of removable partial dentures, the complication of removable partial dentures was still found because of inaccurate fabrication procedure and improper maintenance care. Purpose: The purpose of this study was to evaluate the clinical status of removable partial dentures. Material and methods: A total of 112 individuals with 153 removable partial dentures (35 - 87 years, 64 women and 48 men) were examined by intra-oral examination, diagnostic cast and radiographic examination. Results and conclusion: The results of this study were as follows: 1. Length of service of removable partial dentures was $5.3{\pm}4.3$ years (mean), 4.0 years (median). 2. A total of 45 removable partial dentures were considered failures. The loss of 18 abutments of 369 was founded. 3. Type of arch, Kennedy classification and type of opposite dentition were found to have no influence on longevity and success rate of removable partial dentures (P > .05). 4. Most common major connector was the palatal plate in maxilla and the number of lingual bar and linguoplate designed in mandible were similar. 5. The circumferential type retainer was the most commonly used retainer. 6. Sixty-three percent of the class I and II removable partial dentures incorporated indirect retention into the design. 7. Approximately 81% of the removable partial dentures had at least one defect. Excessive wear of posterior teeth (27.9%), lack of integrity (23.2%), lack of stability (22.6%) were frequent defects of removable partial dentures.

REMOVABLE FLEXIBLE DENTURE FOR CHILD WITH LOSS OF MULTIPLE TEETH : A CASE REPORT (소아에서 다수치아 상실 시 탄성의치 사용의 치험례)

  • Chung, Yang-Seok;Lee, Nan-Young;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.34 no.3
    • /
    • pp.513-518
    • /
    • 2007
  • Loss of multiple teeth by multiple dental caries, traumatic influence or hereditable disease can cause many problem in children. Using removable appliance can be used for treatment of this problem. But conventional removable appliance has limits of retention by wire-clasp, non esthetic appearance, difficulty in pronunciation by its volume. Flexible denture using $Valplast^{(R)}$ system could be a excellent partial denture for restorarion in child because of various advantage such as retention from soft tissue, natural esthetic aspect, biocompatibility, durability to compare with conventional acrylic appliance. The present case report describe properties and consideration of flexible denture using Valplast $system^{(R)}$ in comparison with conventional acrylic appliance and report successful restoration of child using Valplast $system^{(R)}$.

  • PDF

Fabrication of palatal lift prosthesis using thermoplastic resin for a patient with velopharyngeal insufficiency (구개인두부전증 환자에서 열가소성레진을 이용해 연구개거상장치를 제작한 증례)

  • Jung, Hyun Jung;Kim, Jee Hwan;Lee, Sang-Hwy;Park, Young-Bum
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.3
    • /
    • pp.286-290
    • /
    • 2016
  • Recently, flexible removable prosthesis with thermoplastic resin clasp has increasingly become popular. In comparison with conventionally used acrylic resin, thermoplastic resin has lower flexural strength and elastic modulus. Thus, flexible removable prosthesis has low risk of fracture, so denture base can be made thin and light, increasing patient comfort. Also, it can passively sit at tooth undercut during rest, so abutment teeth need minimum or no preparation. In this case report, a 44 year old female patient with mild velopharyngeal insufficiency was treated with a palatal lift prosthesis made of polyester thermoplastic resin. Since the patient had no missing tooth and desired conservative treatment, the flexible removable prosthesis provided relatively satisfactory results.

Frankel Appliance의 원리와 임상적 응용

  • Choe, Yeong-Cheol
    • The Journal of the Korean dental association
    • /
    • v.27 no.11 s.246
    • /
    • pp.1014-1020
    • /
    • 1989
  • 고정식 교정장치를 주로 사용하던 미국에서 최근 가철성 교정장치의 사용이 증가하고 있는데, 독일의 Rolf Frankel이 고안한 Frankel appliance(이하 FR)중 3급 부정교합의 치료를 위한 FR-3의 원리와 작용기전 그리고 임상적용에 관하여 기술하고자 한다.

  • PDF

TREATMENT OF SELF-INJURIOUS BEHAVIOR WITH INTRAORAL APPLIANCE IN EPILEPSY PATIENTS (가철식 장치를 이용한 구강조직 자해 환자의 치료)

  • Kim, Ik-Hwan;Lee, Ko-Eun;Lee, Jae-Ho;Kang, Chung-Min
    • The Journal of Korea Assosiation for Disability and Oral Health
    • /
    • v.12 no.1
    • /
    • pp.16-19
    • /
    • 2016
  • Oral self-injurious behavior (SIB) can be defined as the intentional, direct injuring of oral tissue, most often done without conscious suicidal intent and most commonly associated with tongue or lip biting. Chronic biting of oral mucosa is an innocuous self inflicted injury, commonly seen in children suffering from developmental and psychological problems. The cases presented in this report discuss oral SIB due to epilepsy, quadriplegia and their treatments. This report documents a successful self-injurious behavior treatment of epilepsy patients within a short time by applying a removable intraoral device. Clinicians should notice the possibility of oral SIB in various disorders. Moreover, different treatment should be performed according to the causative disorders and symptoms.

REPOSITIONING OF A LINGUALLY DISPLACED MANDIBULAR FIRST PRIMARY MOLAR BY TRAUMA (외상에 의해 설측 변위된 하악 제1유구치의 가철성 장치를 이용한 치료)

  • Lee, Myung-Sung;Lee, Keung-Ho;Choi, Yeong-Chul;Park, Jae-Hong
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.32 no.1
    • /
    • pp.119-125
    • /
    • 2005
  • In the primary dentitions, the majority of dental injuries involve the anterior teeth, especially the maxillary primary central incisors. When injuries affecting primary and permanent teeth are compared, it appears that trauma to the primary dentition is usually confined to the supporting structures, i.e. luxation and exarticulation, while the largest proportion of injuries affecting the permanent dentition is represented by crown fractures. But, cases reporting trauma affecting primary molars are unusual in the literature and several reports describe fractures of posterior teeth. The main goal of this report is to describe the repositioning treatment using removable appliances to an uncommon case of lingual displacement of primary molar that happened to a 4 year 5 month-old female child.

  • PDF

Implant assisted obturator in patient after maxillectomy: a case report (상악골 절제 환자에서 임플란트를 이용한 구개폐쇄장치 증례)

  • Seo, Yoon-Hee;Lee, Joon-Seok;Song, Young-Gyun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.32 no.4
    • /
    • pp.322-329
    • /
    • 2016
  • Reconstruction of the maxillectomy with an obturator is to restore masticatory, swallowing, phonetic and esthetic problems. Stress created by lateral forces is minimized by the proper selection of an occlusal scheme, elimination of premature occlusal contacts, and wide distribution of supporting area. It should be considered that properly designed retainers reduce the stresses transmitted to the abutment while the obturator is in function. The following clinical report presents palatal obturator treatment with implant assisted removable partial denture (IARPD) design that restores normal function and esthetics in patients who experienced maxillectomy and dental implant failure.

THE CLINICAL APPLICATION OF BUCCAL ACRYLIC APPLIANCES (Buccal acrylic appliance의 임상적 적용)

  • Noh, Hong-Seok;Kim, Shin;Jeong, Tae-Sung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.34 no.2
    • /
    • pp.315-321
    • /
    • 2007
  • Removable appliance has many utilities in pediatric dentistry in the fields of space maintainance or occlusal guidance. In contrast to maxilla, many problems have occurred with mandible in using removable appliance such as deteriorated retention, inconvenience and patient's unwillingness to wear. It is probably due to adapting several retentive clasps at buccal side of the tooth, where there is actually little or no undercut especially in young children having the erupting teeth Moreover, acrylic base plate of conventional removable appliance is located at lingual parts, which leads to the conflict with alveolar crest undercut and sublingual soft tissues. Moreover, young children frequently do not follow the dentist's direction to elevate tongue properly during the impression taking process. Throughout this study, the position of clasps and acrylic baseplate was changed opposite to the traditional Hawley acrylic appliance in order to make a buccal acrylic appliance with buccal base plate and lingual clasp into primary dentition and early mixed dentition. This study was performed for the purpose of evaluating the buccal acrylic appliance in regards of patient compliance, retention and efficiency compared with traditional lingual acrylic appliance along with its merits and demerits. Buccal and lingual acrylic appliance were applied to 5 cases respectively which required space maintaining and tooth movement, and drew a comparison in relevance to patients' compliance, combination with the tongue's function and clinical effectiveness. According to this study, in every case buccal appliance was proved superior to lingual appliance in terms of retention and patients' compliance. Moreover, buccal appliance has shown to be similar to lingual appliance with respect to clinical effectiveness. Throughout this study, it was thought that, if removable appliance is to be applied to mandible, several drawbacks related to conventional lingual appliance shall be resolved. Conclusively, the buccal acrylic appliance is thought to be a good alternative in designing a mandibular appliance in young children and recommended to clinical applications.

  • PDF

TREATMENT OF SELF-INJURIOUS LIP BITING WITH POSTERIOR BITE BLOCK APPLIANCE IN A BRAIN LESION PATIENT (교합 거상판을 이용한 뇌병변장애 환아의 자해성 구강 손상의 치료)

  • Jun, Hyelim;Song, Je-Seon;Lee, Jae-Ho;Lee, Hyo-Seol
    • The Journal of Korea Assosiation for Disability and Oral Health
    • /
    • v.10 no.2
    • /
    • pp.93-96
    • /
    • 2014
  • Brain disorder disability is assessed when organic brain lesion such as cerebral palsy, traumatic brain injury, or stroke causes physical impairment which limits daily activites substantially according to its level and range of paralysis or the presence of involuntary movement. According to the disabled person welfare law in Korea, grade I brain disorder is assessed when one is in continuous irreversible state of coma without the ability to prolong one's life without other's help. Self-injurious behavior is defined as the non-suicidal intentional or unintentional injury to one's own body which can occur repetitively temporarily or chronically. People with decreased consciousness often exhibit increased self-injurious behavior which is most commonly associated with tongue or lip biting. This report documents a successful self -injurious lip biting treatment of a brain lesion patient within a short time by applying a removable acrylic resin appliance including posterior bite block.