• Title/Summary/Keyword: 가진 레이저

Search Result 190, Processing Time 0.021 seconds

Study of the Variation of Optical Amplification Characteristics with Incident Beam Size and Temperature of a Cesium-vapor-based Optical Amplifier (세슘 원자 증기 기반 광 증폭기의 온도와 빔 크기에 따른 광 증폭 특성 연구)

  • Ryu, Siheon;Jeong, Yujae;Yeom, Dong-Il
    • Korean Journal of Optics and Photonics
    • /
    • v.32 no.6
    • /
    • pp.306-313
    • /
    • 2021
  • We study the amplification properties of an optical amplifier based on a cesium-vapor cell. An optical amplification system including cesium vapor mixed with a buffer gas is built, and its amplification feature is investigated as a function of the size of the incident beam and the temperature of the cesium-vapor cell. We observe that the optical amplification properties, such as amplification factor and extraction efficiency, change significantly depending on the temperature and beam diameter of the pump and seed light. A maximum extraction efficiency of 56% is obtained when the temperature of the cesium cell is 90 ℃, with a 200-㎛ diameter of the pump (500 mW) and seed light (10 mW). The numerical simulation of the amplification properties agrees reasonably with the results obtained from the experiment.

Evaluation of the usefulness of IGRT(Image Guided Radiation Therapy) for markerless patients using SGPS(Surface-Guided Patient Setup) (표면유도환자셋업(Surface-Guided Patient Setup, SGPS)을 활용한 Markerless환자의 영상유도방사선치료(Image Guided Radiation Therapy, IGRT)시 유용성 평가)

  • Lee, Kyeong-jae;Lee, Eung-man;Lee, Jeong-su;Kim, Da-yeon;Ko, Hyeon-jun;Choi, Shin-cheol
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.33
    • /
    • pp.109-116
    • /
    • 2021
  • Purpose: The purpose of this study is to evaluate the usefulness of Surface-Guided Patient Setup by comparing the patient positioning accuracy when image-guided radiation therapy was used for Markerless patients(unmarked on the skin) using Surface-Guided Patient Setup and Marker patients(marked on the skin) using Laser-Based Patient Setup. Materials And Methods: The position error during IGRT was compared between a Markerless patient initially set up with SGPS using an optical surface scanning system using three cameras and a Marker patient initially set up with LBPS that aligns the laser with the marker drawn on the patient's skin. Both SGPS and LBPS were performed on 20 prostate cancer patients and 10 Stereotactic Radiation Surgery patients, respectively, and SGPS was performed on an additional 60 breast cancer patients. All were performed IGRT using CBCT or OBI. Position error of 6 degrees of freedom was obtained using Auto-Matching System, and comparison and analysis were performed using Offline-Review in the treatment planning system. Result: The difference between the root mean square (RMS) of SGPS and LBPS in prostate cancer patients was Vrt -0.02cm, Log -0.02cm, Lat 0.01cm, Pit -0.01°, Rol -0.01°, Rtn -0.01°, SRS patients was Vrt 0.02cm, Log -0.05cm, Lat 0.00cm, Pit -0.30°, Rol -0.15°, Rtn -0.33°. there was no significant difference between the two regions. According to the IGRT standard of breast cancer patients, RMS was Vrt 0.26, Log 0.21, Lat 0.15, Pit 0.81, Rol 0.49, Rtn 0.59. Conclusion:. As a result of this study, the position error value of SGPS compared to LBPS did not show a significant difference between prostate cancer patients and SRS patients. In the case of additionally performed SGPS breast cancer patients, the position error value was not large based on IGRT. Therefore, it is considered that it will be useful to replace LBPS with SGPS, which has the great advantage of not requiring patient skin marking..

Contaminant Mechanism and Management of Tracksite of Pterosaurs, Birds, and Dinosaurs in Chungmugong-dong, Jinju, Korea (천연기념물 진주 충무공동 익룡·새·공룡발자국 화석산지의 오염물 형성 메커니즘과 관리방안)

  • Myoungju Choie;Sangho Won;Tea Jong Lee;Seong-Joo Lee;Dal-Yong Kong;Myeong Seong Lee
    • Economic and Environmental Geology
    • /
    • v.56 no.6
    • /
    • pp.715-728
    • /
    • 2023
  • Tracksite of pterosaurs, birds, and dinosaurs in Chungmugong-dong in Jinju was designated as a natural monument in 2011 and is known as the world's largest in terms of the number and density of pterosaur footprints. This site has been managed by installing protection buildings to conserve in 2018. About 17% of the footprints of pterosaur, theropod, and ornithopod in this site under management in the 2nd protection building are of great academic value, but observation of footprints has difficulties due to continuous physical and chemical damage. In particular, the accumulation of milk-white contaminants is formed by the gypsum and air pollutant complex. Gypsum remains evaporated with a plate or columnar shape in the process of water circulation around the 2nd protection building, and the dust is from through the inflow of the gallery windows. The aqueous solution of gypsum, consisting of calcium from the lower bed and sulfur from grass growth, is catchmented into the groundwater from the area behind the protection building. Pollen and a few minerals other constituents of contaminants, go through the gallery window, which makes it difficult to expel dust. To conserve the fossil-bearing beds from two contaminants of different origins, controlling the water and atmospheric circulation of the 2nd protection building and removing the contaminants continuously is necessary. When cleaning contaminants, the steam cleaning method is sufficiently effective for powder-shaped milk-white contaminants. The fossil-bearing bed consists of dark gray shale with high laser absorption power; the laser cleaning method accompanies physical loss to fossils and sedimentary structures; therefore, avoiding it as much as possible is desirable.

Ambient CO2 Measurement Using Raman Lidar (라만 라이다를 이용한 대기 중 이산화탄소 혼합비 측정)

  • Kim, Daewon;Lee, Hanlim;Park, Junsung;Choi, Wonei;Yang, Jiwon;Kang, Hyeongwoo
    • Korean Journal of Remote Sensing
    • /
    • v.35 no.6_3
    • /
    • pp.1187-1195
    • /
    • 2019
  • We, for the first time, developed a Raman lidar system which can remotely detect surface CO2 volume mixing ratio (VMR). The Raman lidar system consists of the Nd: YAG laser of wavelength 355 nm with 80 mJ, an optical receiver, and detectors. Indoor CO2 cell measurements show that the accuracy of the Raman lidar system is calculated to be 99.89%. We carried out the field measurement using our Raman lidar at Pukyong National University over a seven-day period in October 2019. The results show good agreement between CO2 VMRs measured by the Raman lidar (CO2 Raman Lidar) and those measured by in situ instruments (CO2 In situ) which located 300 m and 350 m away from the Raman lidar system. The correlation coefficient (R), mean absolute error (MAE), and root mean square error (RMSE) between CO2 In situ and CO2 Raman Lidar are 0.67, 2.78 ppm, and 3.26 ppm, respectively.

The effects of a sealant resin on enamel demineralization in orthodontic bracket bonding (브라켓 부착 시 실런트 레진이 법랑질 탈회에 미치는 영향)

  • Youn, Young-An;Cho, Jin-Hyoung;Lee, Ki-Heon
    • The korean journal of orthodontics
    • /
    • v.35 no.1 s.108
    • /
    • pp.43-50
    • /
    • 2005
  • The purpose of this study was to evaluate the effects of a sealant resin on enamel demineralization In orthodontic bracket bonding. The forty eight extracted sound bovine teeth were subdivided into four groups and treated with Phase II (Reliance, itasca. III) on the surface Group 1 was not treated. Group 2 was acid etched with 37% phosphoric acid for 30 seconds. Group 3 was applied with sealant after acid etching. Group 4 was applied with resin paste after acid etching and sealant application. Each group was demineralized in artificial caries solution. Demineralized enamel depth was measured by confocal laser scanning microscopy. The results were as follows: the mean demineralized enamel depth was $47.4{\mu}m$. (Group 1), $61.8{\mu}m$ (Group 2), $13.9{\mu}m$ (Group 3). $8.2{\mu}m$ (Group 4) the demineralized enamel depth was increased in Group 2 than in Group 1 (p<0.05); the demineralized enamel depth was reduced in Group 3 than in Group 1 and Group 2 with statistically significant differences (p<0.05): and demineralization in Group 4 was very little. The results of the present study indicate that sealant application is useful for reducing enamel demineralization in orthodontic bracket bonding.

Experimental Analysis on Vibration of Composite Plate by Using FBG Sensor System (브래그 격자 센서 시스템을 이용한 복합재 평판 진동의 실험적 해석)

  • Kim, Dae-Hyun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.5
    • /
    • pp.436-441
    • /
    • 2009
  • A fiber optic sensor is prospective to be applied to structural health monitoring. Especially, a fiber Bragg grating(FBG) sensor is one of the most popular sensors for the structural health monitoring. The FBG sensor has several demodulation systems for tracking the shift of the Bragg wavelength. The dynamic bandwidth is dependent on the demodulation system. In this paper, the sensing mechanism is that the slope of the optical spectrum of FBG could be used as its sensitivity when the tunable laser shot the monochromatic laser wavelength at the highest slope point. In this technique, the high sensitivity is guaranteed even though the sensing range is limited. In an example of the application, the composite plate embedding a FBG sensor was manufactured by using an autoclave method and the above sensing mechanism was applied to the composite plate. Firstly, the natural frequencies of the plate were successfully measured by the FBG sensor during the impact hammer test. Secondly, a high-power speaker was used to force the plate to be vibrated at the specific frequency that was one of the natural frequencies. During the shaking, the FBG sensor measures the dynamic characteristics and ESPI was also used to measure the mode shape. From the two dynamic tests, the availability of the FBG sensor system and the ESPI was proven as a technique for measuring the dynamic characteristics of composite structure.

Dynamic Characteristics of Actuator for High Density Optical Recording Pick-up (고밀도 기록용 광픽업의 ACTUATOR 동특성)

  • 임경화;이용훈;김석중;이재원
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1995.04a
    • /
    • pp.258-263
    • /
    • 1995
  • 미래 정보와 시대에서 중추적인 역할을 할 광관련 멀티미디어 장비들은 최근 관련 산업계에서 주목을 받기 시작하고 있고 특히 기존 VTR(Video Tape Recorder) 시장을 대체할 차세대 DVDR(Digital Video Disk Recorder)는 기술전쟁이라고 할 정도로 선진 기업의 연구가 치열해지고 있다. DVDR 시스템에서는 필요한 정보들을 레이저빔을 이용한 광학신호로 바꾸어 광디스크에 기록, 재생하는 광픽업이 절대적으로 필요하게 된다. 그런데 광픽업의 위치추종기구인 Actuator는 정확한 위치추종(.+-.1.$\mu$m 오차이내)을 할 수 있는 성능이 요구되며 서보의 특성상 20KHz 이하에서 불필요한 모우드가 가진되지 않는 정밀부품이어야 하므로 Actuator 각 부품의 동적인 특성을 명확히 규명할 필요가 있다. 따라서 본 연구에서는 우선 Actuator 각 부품과 가동부 전체의 중량 및 진동해석을 통해 동특성을 조사하였다. 그리고 Actuator의 중요한 기본성능중 하나인 구동감도 확보여부를 검토할 필요가 있기 때문에 유한요소법 프로그램인 ANSYS를 이용하여 자기회로 부분에 대한 해석을 구하였다. 또한 가동부와 자기회로 등 하위부품을 조립하는 과정에서 발생하는 조립오차로 인해 불필요한 공진과 회전형상이 야기될 수 있으므로 동특성 및 문제점 파악을 위한 민감도 분석이 필요하다. 따라서 본 연구에서는 가동부의 관성 모멘트 값과 강체에 대한 일반식을 이용한 자체 프로그램을 작성하여 조립공차를 구하였다. 이와같은 과정을 통해 구해진 설계값을 바탕으로 실제 제작된 Actuator에 대해서는 비접촉식 측정방법을 통해 동특성값을 측정하였고 이를 해석값과 상호 비교하였다.동강성행렬법(dynamic stiffness matrix method)을 이용하여 해석하고자 한다. 수준임이 입증되었다. 본 연구의 결과를 토대로우리나라 젊고 건강한 남성에게 적합한 무게상수는 작업자군에 대하여 25.05kg, 학생군에 대하여 20.24kg 으로 나타나 이는 미국 NIOSH 안전기준과 대체로 일치함을 발견하였다.ive structures utilized in Client/server architecture for distribution and cooperative processing of application between server and client this study presents two different data management methods under the Client/server environment; one is "Remote Data Management Method" which uses file server or database server and. the other is "Distributed Data Management Method" using distributed database management system. The result of this study leads to the conclusion that in the client/server environment although distributed application is assumed, the data could become centralized (in the case of file server or database server) or decentralized (in the case of distributed

  • PDF

고주파 스퍼터링법으로 증착한 ZnO 박막의 응력 형성

  • 곽상현;이재빈;김형준
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2000.02a
    • /
    • pp.193-193
    • /
    • 2000
  • 박막 내의 잔류 응력은 막의 기계적 전기적 물성을 변화시키는 등 박막에 많은 영향을 끼치는 것으로 알려져 있다. 이러한 응력은 박막의 증착 공정중 여러 가지 증착 조건에 의해서 변화하게 되는데, 특히 스퍼터링 시스템의 경우에는 증착 압력과 사용하는 가스, 인가되는 전력 등 기본적인 증착조건들에 상당한 영향을 받는다. 이러한 영향은 금속 박막의 경우 상당히 잘 알려져 있다. 또한 반도체 공정에서 금속화 과정중 금속 전극의 단락등을 막기 위해 많은 연구가 진행되어 왔다. 본 논문에서는 고주파 마그네트론 스퍼터링 시스템을 사용하여 산화 아연(ZnO)을 증착하고 여러 공정 변수들에 따른 응력의 변화를 관찰하였다. 실험에서 ZnO 타겟을 사용하였으며, 작동 가스로는 아르곤과 산소를 사용하였다. 증착한 박막들은 모두 압축 응력을 보였으며, 박막의 응력에 가장 큰 영향을 미치는 요소들은 압력, 산소와 아르곤의 비, 기판과 타겟과의 거리 등이었는데, 인가 전력에는 거의 영향을 받지 않았다. 일반적으로 스퍼터링 시스템에서의 압축응력은 atomic peening에 의해서 형성되는데, 박막을 두드리는 높은 에너지의 아르곤이나 산소의 유량과 에너지의 1/2승에 비례하는 것으로 알려져 있다. 그러나 본 시스템에서는 인가 전력을 높여도 응력이 증가하지 않았고, 타겟과의 거리를 줄이면 오히려 응력이 감소함을 보였다. 이는 박막의 응력이 peening 하는 입자의 에너지뿐만이 아니라 증착되는 물질의 증착 속도와도 밀접한 관련이 있음을 보여준다. 즉, 증착속도가 증가하면 peening하는 입자가 끼치는 응력의 효과가 반감되기 때문으로 수식을 통해 증명할 수 있었다.진탄화 처리시간을 변화시켰을 때 화합물층의 생성은 ${\gamma}$'상으로부터 시작되고 $\varepsilon$상은 즉시 ${\gamma}$'상을 소모하면서 생성되어 일정시간이 지난 후 $\varepsilon$상은 안정화되며 질소가스농도가 증가할수록 화합물 층내의 $\varepsilon$상분율은 역시 증가하였다. 한편 CH4 가스농도는 처리되는 강종에 따라 차이를 보이며 적정 CH4 가스농도를 초과시에는 $\varepsilon$상 생성은 억제되고 시멘타이트상이 생성되었다.e에서 발생된 질소 플라즈마를 구성하는 이온들의 종류와 그 구성비율을 연구하였다.여러 가지 응용으로의 가능성을 가지고 있다. 그 예로 plasma processing, plasma wave에 의한 입자 가속, 그리고 가스 레이저 활성 매질 발생 등이 있다. 특히 plasma processing의 경우 helicon plasma는 높은 밀도, 비교적 낮은 자기장, remote operation 등이 가능하다는 점에서 현재 연구가 활발히 진행되고 있다. 상업용으로도 PMT와 Lucas Signatone Corp.에 서 helicon source가 제작되었다. 또한 높은 해리율을 이용하여 저유전 물질인 SiOF의 증착에서 적용되고 있다. 이 외에도 다수의 연구결과들이 발표되었다. 잘 일치하였다.ecursor 분자들이 큰 에너지를 가지고 기판에 유입되어 치밀한 박막이 형성되었기 때문으로 사료된다.을수 있었다.보았다.다.다양한 기능을 가진 신소재 제조에 있다. 또한 경제적인

  • PDF

Single-Camera Micro-Stereo 4D-PTV (단일카메라 마이크로 스테레오 4D-PTV)

  • Doh, Deog-Hee;Cho, Young-Beom;Lee, Jae-Min;Kim, Dong-Hyuk;Jo, Hyo-Jae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.12
    • /
    • pp.1087-1092
    • /
    • 2010
  • A micro 3D-PTV system has been constructed using a single camera system. Two viewing holes were created behind the object lens of the microscopic system to construct a stereoscopic viewing image. A hybrid recursive PTV algorithm was used. A concept of epipolar line was adopted to eliminate many spurious candidates. Three-dimensional velocity vector fields were obtained by calculating the three-dimensional displacements of particles that were identified as being identical. The system consists of a laser light source (Ar-ion, 500 mW), one high-definition camera ($1028{\times}1024$ pixels, 500 fps), a circular plate with two viewing holes, and a host computer. The performance of the developed algorithm was tested using artificial images. The characteristic of the vector recovery ratio was investigated for the particle numbers. A micro backward-facing step channel ($H{\times}h{\times}W:\;36{\mu}m{\times}70{\mu}m{\times}3000{\mu}m$) was measured using the developed measurement system. The results were in good qualitative agreement with other results.

The Effect of Ginkgo Biloba Extract on the Fractionsted Radiation Therapy in C3H Mouse Fibrosarcoma (Ginkgo Biloba Extract가 C3H 마우스 섬유육종의 분할 방사선치료에 미치는 영향)

  • Kim, Jong-Hoon;Ha, Sung-Whan;Park, Charn-Il
    • Radiation Oncology Journal
    • /
    • v.20 no.2
    • /
    • pp.155-164
    • /
    • 2002
  • Purpose : A ginkgo biloba extract (GBE) has been known as a hypoxic cell radiosensitizer. Its mechanisms of action are increase of the red blood cell deformability, decrease the blood viscosity, and decrease the hypoxic cell fraction in the tumor. The aims of this study were to estimate the effect of GBE on fractionated radiotherapy and to clarify the mechanism of action of the GBE by estimating the blood flow in tumor and normal muscle. Materials and Methods : Fibrosarcoma (FSall) growing in a C3H mouse leg muscle was used as the tumor model. When the tumor size reached 7 mm in diameter, the GBE was given intraperitoneally at 1 and 25 hours prior to irradiation. The tumor growth delay was measured according to the various doses of radiation (3, 6, 9, 12 Gy and 15 Gy) and to the fractionation (single and fractionated irradiation) with and without the GBE injection. The radiation dose to the tumor the response relationships and the enhancement ratio of the GBE were measured. In addition, the blood flow of a normal muscle and a tumor was compared by laser Doppler flowmetry according to the GBE treatment. Results : When the GBE was used with single fraction irradiation with doses ranging from 3 to 12 Gy, GBE increased the tumor growth delay significantly (p<0.05) and the enhancement ratio of the GBE was 1.16. In fractionated irradiation with 3 Gy per day, the relationships between the radiation dose (D) and the tumor growth delay (TGD) were TGD $(days)=0.26{\times}D$ (Gy)+0.13 in the radiation alone group, and the TGD $(days)=0.30{\times}D$ (Gy)+0.13 in the radiation with GBE group. As a result, the enhancement ratio was 1.19 ($95\%$ confidence interval; $1.13\~1.27$). Laser Doppler flowmetry was used to measure the blood flow. The mean blood flow was higher in the muscle (7.78 mL/100 g/min in tumor and the 10.15 mL/100 g/min in muscle, p=0.005) and the low blood flow fraction (less than 2 mL/100 g/min) was higher in the tumor $(0.5\%\;vs.\;5.2\%,\;p=0.005)$. The blood flow was not changed with the GBE in normal muscle, but was increased by $23.5\%$ ( p=0.0004) in the tumor. Conclusion : Based on these results, it can be concluded that the GBE enhanced the radiation effect significantly when used with fractionated radiotherapy as well as with single fraction irradiation. Furthermore, the GBE increased the blood flow of the tumor selectively.