급수가열기 추기노즐의 개선된 충격판 모델에 관한 연구 (A Study on Advanced Impinging Baffle Model in Extraction Nozzle of a Feedwater Heater)

  • 이우;황경모;김경훈
    • 한국분무공학회지
    • /
    • 제12권1호
    • /
    • pp.18-29
    • /
    • 2007
  • Feedwater heaters of many nuclear power plants have recently experienced severe wall thinning damage, which will increase as operating time progresses. Several nuclear power plants in Korea have experienced wall thinning damage in the area around the impingement baffle - installed downstream of the high pressure turbine extraction steam line - inside number 5A and 5B feedwater heaters. At that point, the extracted steam from the high pressure turbine is two phase fluid at high temperature, high pressure, and high speed. Since it flows in reverse direction after impinging the impingement baffle, the shell wall of the number 5 high pressure feedwater heater may be affected by flow-accelerated corrosion. This paper describes the comparisons between the numerical analysis results using the FLUENT code and the down scale experimental data in an effort to determine root causes of the shell wall thinning of the high pressure feedwater heaters. The numerical analysis and experimental data were also confirmed by actual wall thickness measured by an ultrasonic test.

  • PDF

유동가속부식으로 인한 급수가열기 동체 감육현상 규명과 완화 방안 및 충격판 설계개선에 관한 연구 (A Study on the Shell Wall Thinning by Flow Acceleration Corrosion and Mitigation Plan and Design Modification of a Feedwater Heater Impingement Baffle)

  • 김경훈;황경모;김인태
    • 한국분무공학회지
    • /
    • 제15권2호
    • /
    • pp.83-93
    • /
    • 2010
  • Feedwater heaters of many nuclear power plants have recently experienced severe wall thinning damage, which will increase as operating time progresses. Several nuclear power plants in Korea have experienced wall thinning damage in the area around the impingement baffle inside feedwater heater installed downstream of the turbine extraction stream line. At that point, the extract steam from the turbine is two phase fluid at high temperature, high pressure, and high speed. Since it flows to reverse direction after impinging the impingement baffle, the shell wall of feedwater heaters may be affected by flow-accelerated corrosion. In this paper, to compare degree of shell wall thinning mitigation rate to squared type with mitigation rate of other type baffle plate, four different types of impingement baffle plate-squared, curved, mitigating type and multi-hole type-applied inside the shell. With these comparison data, this paper describes operation of experiments and numerical analysis which is composed similar condition with real feed water heater. And flow visualization is operated for verification of experiments and numerical analysis. In conclusion, this study shows that mitigating type and multi-hole type baffle plate are more effective than other baffle plate about prevention of pressure concentration and pressure value decrease.

급수가열기 추기노즐 충격판 주변의 동체감육 현상규명을 위한 실험 및 수치해석 연구 (A Study on Experiment and Numerical Analysis for Disclosing Shell Wall Thinning of a Feedwater Heater)

  • 김경훈;이우;황경모
    • 대한기계학회논문집B
    • /
    • 제31권1호
    • /
    • pp.1-7
    • /
    • 2007
  • Feedwater heaters of many nuclear power plants have recently experienced severe wall thinning damage, which will increase as operating time progresses. Several nuclear power plants in Korea have experienced wall thinning damage in the area around the impingement baffle - installed downstream of the high pressure turbine extraction steam line - inside number 5A and 5B feedwater heaters. At that point, the extracted steam from the high pressure turbine is two phase fluid at high temperature, high pressure, and high speed. Since it flows in reverse direction after impinging the impingement baffle, the shell wall of the number 5 high pressure feedwater heater may be affected by flow-accelerated corrosion. This paper describes the comparisons between the numerical analysis results using the FLUENT code and the down scale experimental data in an effort to determine root causes of the shell wall thinning of the high pressure feedwater heaters. The numerical analysis and experimental data were also confirmed by actual wall thickness measured by an ultrasonic test.

1차곡을 갖는 판의 곡가공을 위한 유도가열 시뮬레이터의 개발 (Development of Induction Heating Simulator for the Bending of Plates with Primary Curvature)

  • 이영화;하윤석;장창두
    • 대한조선학회논문집
    • /
    • 제42권3호
    • /
    • pp.241-248
    • /
    • 2005
  • The induction heating is more efficient for a plate bending because of its easy operation and control of working parameters compared with the heating by torch. In this study, a more efficient method was proposed for the prediction of plate bending. The existing analysis method using the axi-symmetric coil model could not handle the varying temperature during the heating and the forming process for curved plates like a saddle or a concave type curvature. The proposed method using some discrete steps in this study could overcome these difficulties and show more accurate, reasonable results in temperatures and deflections of fiat or curved plates. This method is composed of multi-disciplinary analyses such as an electro-magnetic analysis, a heat transfer analysis and a deformation analysis based on inherent strain approach.

급수가열기 동체 감육 현상과 완화 방안 및 충격판 설계개선 (Shell Wall Thinning and Mitigation Plan and Design Modification of a Feedwater Heater Impingement Baffle)

  • 김경훈;황경모;박상훈
    • 한국정밀공학회지
    • /
    • 제27권6호
    • /
    • pp.55-63
    • /
    • 2010
  • Feedwater heaters of many nuclear power plants have recently experienced severe wall thinning damage, which will increase as operating time progresses. Several nuclear power plants in Korea have experienced wall thinning damage in the area around the impingement baffle inside feedwater heater installed downstream of the turbine extraction stream line. At that point, the extract steam from the turbine is two phase fluid at high temperature, high pressure, and high speed. Since it flows to reverse direction after impinging the impingement baffle, the shell wall of feedwater heaters may be affected by flow-accelerated corrosion. In this paper, to compare degree of shell wall thinning mitigation rate to squared type with mitigation rate of other type baffle plate, three different types of impingement baffle plate-squared, curved and mitigating type-applied inside the shell. With these comparison data, this paper describes operation of experiments and numerical analysis which is composed similar condition with real feed water heater. And flow visualization is operated for verification of experiments and numerical analysis. In conclusion, this study shows that mitigating type baffle plate is more effective than other baffle plate about prevention of pressure concentration and pressure value decrease.

표준화재 재하조건 이방향 중공슬래브의 화재거동에 관한 실험적 연구 (An Experimental Study on the Fire Behavior of Two-way Void Slab under Standard Fire with Loading condition)

  • 김형준;여인환;김흥열;조경숙;김정현
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2010년도 추계학술발표회 자료집
    • /
    • pp.17-20
    • /
    • 2010
  • 기존의 무량판 구조와 동일한 이방향 슬래브구조인 TVS(two-way void slab)공법은 구조적 하중지지 성능이 불필요한 슬래브 단면상의 중앙부 콘크리트를 제거하여 슬래브의 자중을 줄이고 무량판 구조의 단점을 보완하여 장점을 극대화시킨 구조형식이다. 그러나 이러한 장점을 보유한 공법을 현장적용하기 위해서는 내화성능평가를 통해 화재안전성을 확보하여야 하므로, 이에 대한 화재 실증실험을 수행하여 현장적용을 위한 최소 요구내화 시간에 따른 내화성능 확보방안의 도출이 제시되어야 한다. 이에 본 연구에서는 TVS공법의 실제 스팬길이로 슬래브 피복두께에 따른 화재거동 영향성 분석을 위하여 화재실험을 수행하였다. 하중조건은 고정하중과 적재하중을 고려하여 실험체에 등분포 조건으로 사전재하하였으며, 표준화재조건으로 재하가열 실험을 수행하였다. 슬래브의 화재가열 노출면으로부터의 깊이별 온도변화와 처짐변형 특성을 측정하였으며, KS F 2257-1 평가기준에 의거하여 슬래브의 내화성능을 평가하였다. 실험결과 피복두께 50 mm를 확보할 경우, EPS중공체로 제작한 실험체의 경우 약 2시간정도의 내화성능을 확보할 수 있는 것으로 나타났다.

  • PDF

대두유의 가열산화중의 특성변화 -제 1 보 : 가열산화중의 대두유의 일부 화학적, 물리적 성질의 변화- (Studies on Thermal Oxidation of Soybean Oil -I. Changes in Some Chemical and Physical Properties of a Soybean Oil during Thermal Oxidation-)

  • 신애자;김동훈
    • 한국식품과학회지
    • /
    • 제14권3호
    • /
    • pp.257-264
    • /
    • 1982
  • 식용대두유에 공기를 다공성 가스 분산판을 통해서 주입(120ml/min)하면서 가열산화온도를 30에서 $180^{\circ}C$까지 변화시킬때(10시간)의 대두유의 일부 특성변화를 조사하였다. 그 결과는 다음과 같다. 본 실험에 사용된 대두유는 120ml/min의 공기주입 속도하에서는 그 과산화물값, TBA값과 요오드값은 가열산화온도가 $80^{\circ}C$를 넘을때 크게 증가했었다. 대두유의 지방산조성을 볼때 가열산화온도가 $80^{\circ}C$가 넘을때 불포화지방산의 함량의 변화는 컸었다. 그 반면에 포화지방산 함량의 변화는 거의 없었다. 이와같은 변화는 가열산화중의 대두유의 요오드값의 변화와 잘 일치 했었다. 한편, 산값은 가열산화온도가 $160^{\circ}C$를 넘을때 크게 증가했었다. 대두유의 굴절율과 점도는 가열산화온도와 시간이 증가함에 따라 증가했으나, 점도의 경우에는 가열 산화온도가 $180^{\circ}C$ 이상의 경우 크게 증가했었다. 본 실험의 가열산화조건하에서의 시료유지의 점도(V)와 가열 산화온도$(T^{\circ}K)$ 사이의 관계는 다음 식으로 표시할 수 있었다. $$V=Aexp({\frac{E}{RT}})$$ 여기서 A는 함수 E는 점성흐름의 활성화 에너지, R은 기체항수이다. 한편 $20^{\circ}C$에서 측정한 가열산화된 대두유의 굴절율$({n_D}^{20})$과 점도(V) 사이에는 다음과 같은 관계식이 성립하였었다. $${n_D}^{20}=1.4614+7.3333{\times}10^{-5}t+2.9612{\times}10^{-3}InV$$여기서 t는 점도측정온도$(^{\circ}C)$, InV는 점도의 자연대수치이다.

  • PDF

냉각탑 공기가열기용 전열판의 수치해석적 성능 비교 (Performance Comparison of Heat Transfer Plates for Cooling Tower Air Heater Through Numerical Analysis)

  • 이을종;김정식;김내현
    • 한국산학기술학회논문지
    • /
    • 제13권12호
    • /
    • pp.5676-5683
    • /
    • 2012
  • 본 연구에서는 백연방지용 냉각탑의 공기가열기 적용을 목적으로 현재 냉각탑의 충진재로 적용되고 있는 쉐브론형, 웨이브형 그리고 딤플형 전열판 형상에 대한 수치해석을 수행하였다. 해석 결과 동일 소비동력 대비 전열량은 평판보다 고성능 전열판에서 높게 나타났다. 열전달계수는 웨이브 형상에서 가장 크고 쉐브론 형상, 딤플 형상 순으로 나타났다. 웨이브 형상의 경우 교차하는 절곡형상 사이의 왕성한 혼합유동이 열전달 계수를 증진시킨 것으로 판단된다. 마찰계수는 열전달계수와 유사한 경향을 보였다. 하지만 동일 크기 쉬트에서의 전열량 및 압력손실은 쉐브론형에서 가장 크게 나타났다. 이는 쉐브론 형상의 전열면적이 다른 형상에 비하여 월등히 크기 때문이다.

저진공 내 시료가열판과 시료의 열전달 (Heat Transfer between Substrate and Substrate-heater in Low Vacuum)

  • 박현재;오수기;신용현;정광화
    • 한국진공학회지
    • /
    • 제17권4호
    • /
    • pp.302-310
    • /
    • 2008
  • 진공 챔버 내부에서 열접촉된 시료가열장치와 시료 사이의 열전달 현상을 고찰하였다. 열전달은 가스 유량과 기체 압력에 따른 대류현상, 시료와 접촉하는 기판가열장치의 표면 거칠기 및 접촉압력에 따른 전도현상, 기판가열장치의 표면 방사율에 따른 복사현상으로 나누어 푸리에 식과 슈테판-볼츠만 식을 이용하여 열흐름 값을 분석하였다. 실험은 시료가열장치의 온도를 $100\;-\;500^{\circ}C$ 사이에서 일정하게 유지하면서 300 mTorr - 1 Torr 사이의 압력에 따른 시료의 온도를 측정하고, 푸리에 식과 슈테판-볼츠만 식을 이용하여 열흐름 값을 계산하였다. 열흐름 값의 산출에 사용된 푸리에 계수의 정확성을 확인하기 위해, 역으로 열흐름 값으로부터 온도차를 구하는 방법을 사용하였으며 0.33 % 오차 내에서 재현됨을 확인하였다.

탄소섬유쉬트 보강 콘크리트용 무기계 폴리머 접착제의 내화 및 구조성능 (Structural Performance and Fire Resistance Capacity of Inorganic Polymer Composites for Carbon Sheets Exposed to High Temperature)

  • 정란;박현수
    • 콘크리트학회지
    • /
    • 제10권5호
    • /
    • pp.109-115
    • /
    • 1998
  • 철근콘크리트 구조물이 과소설계되어 있거나 과다 하중이 작용하게 되면 그 구조물의 구조성능을 파악하여 보수.보강을 시행하게 된다. 최근에 가장 맣이 사용되는 보수.보강 재료로는 특히 휨내력을 보강하는데 탄소섬유를 들 수 있다. 탄소섬유쉬트는 내열성과 내호염성에 있어서 회재가 발생할 경우 보강재료로서 충분한 성능을 가지고 있다. 그러나 이를 접착시키는데 사용되는 에폭시는 유기계 물질로서 화재시 유독가스가 발생하고 내열성능도 30$0^{\circ}C$정도에도 지탱하기 어려워 화재 발생이 가능한 구조물에 사용하기 어렵다. 이 연구에서는 무기계 폴리머 복합재료로 접착된 탄소섬유를 고온(약 800~100$0^{\circ}C$, 1시간)으로 가열한 후 가열된 섬유판의 인장, 휨 전단내력을 검토하여 내열성능을 파악하고 이 섬유쉬트로 보강한 철근콘크리트 부재의 휨 성능을 실험적으로 규명하여 화재의 위험이 있는 구조물에 구조적인 보강재료로 사용이 가능한가를 검토하였다. 연구 결과, 개발된 무기계 폴리머 복합체는 인장강도, 휨강도 및 접착강도가 유기계 접착제와 유사하게 나타났고 800~100$0^{\circ}C$ 정도로 1시간 가열한 이후에도 상온 시험체 휨내력과 전단내력의 63%, 33% 정도를 유지하여 화재의 위험이 있는 부위에도 사용이 가능한 것으로 판단되었다.