• Title/Summary/Keyword: 가열기

Search Result 782, Processing Time 0.032 seconds

A Study on Thermal Storage Performance and Characteristics of Daily Operation of a Hybrid Solar Air-Water Heater (복합형 태양열 가열기의 일일 운전 특성 및 축열 성능에 관한 연구)

  • Choi, Hwi-Ung;Rokhman, Fatkhur;Yoon, Jung-In;Son, Chang-Hyo;Choi, Kwang-Hwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.35 no.3
    • /
    • pp.73-79
    • /
    • 2015
  • In this study, a thermal storage performance and characteristics of daily operation were investigated when the air and the liquid were heated simultaneously by a hybrid solar air-water heater that can make hot water as well as heated air. The hybrid solar air-water heater is kind of a flat plate solar collector that can make hot water and heated air by installing air channel beneath absorber plate of traditional flat plate solar collector for hot water. As a result of daily operation, maximum water temperature reached in a thermal storage was shown $44^{\circ}C$ on 73kg/h of air mass flow rate and about $40^{\circ}C$ on 176kg/h of air mass flow rate. Thus, the necessity of heating water in thermal storage by operating only liquid side was confirmed when the temperature of liquid in thermal storage is lower than we need. In case of efficiency investigated on daily operation, the thermal efficiency of the liquid side was decreased with increment of the inlet liquid temperature and decrement of the solar radiation, but efficiency of the air side was increased with increment of inlet liquid temperature difference as the traditional solar air heater. Total thermal efficiency of the collector was shown from 65.85% to 78.23% and it was decreased with increment of the inlet liquid temperature and decrement of solar radiation same as the traditional system.

A Study on the Development of Superheater Using High-Frequency Resonant Inverter for Induction Heating (유도가열용 고주파 공진형 인버터를 이용한 과열증기 발생장치 개발에 관한 연구)

  • 신대철;권혁민;김기환;김용주
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.9 no.2
    • /
    • pp.119-125
    • /
    • 2004
  • This paper is described the indirect induction heated boiler system and induction heated hot air producer using the voltage-fed series resonant high-frequency inverter which can operate in the frequency range from 20〔KHz〕 to 50〔KHz〕. A specially designed Induction heater, which is composed of laminated stainless assembly with many tiny holes and interconnected spot welding points between stainless plates, is inserted into the ceramic type vessel with external working coil. This working coil is connected to the resonant inverter. In the induction heater, it's primary heating section creates low-pressure saturated steam and secondary heating section generates heat distribution evaporating fluid from the turbulence fluid which is flowing through the vessel. The operating performances of this unique appliance in next generation and its effectiveness are evaluated and discussed from the practical point of view.

Changes of Hydrophobicity, Solubility, SH Group and Protein-Protein Interaction in Yellowtail Myosin and Whelk Paramyosin During Thermal Denaturation (가열 변성에 따른 방어 Myosin과 갈색띠 매물고둥 Paramyosin의 소수성, 용해도, SH기 및 단백질간 상호작용의 변화)

  • Choi, Yeung-Joon;Pyeun, Jae-Hyeung
    • Korean Journal of Food Science and Technology
    • /
    • v.19 no.2
    • /
    • pp.89-96
    • /
    • 1987
  • The denaturation mechanism of the protein during heating of myosin and paramyosin extracted from the ordinary muscle of yellowtail (Seriola qrinqueradits) and the adductor muscle of whelk (Neptunea arthritica cuming) were investigated by analyzing the hydrophobicity, solubility, SH group and protein-protein interaction. The free hydrophobic residue of the two proteins were increased by increase of heating temperature up to $65^{\circ}C$ and then decreased for further temperature raise. The protein-protein interaction was proportional to the increment of the free hydrophobic residue. The aggregation of protein was begun from $65^{\circ}C$ with the decrease of the free hydrophobic residues. The results of Arrhenius equation for the data on proteinprotein interaction showed that the denaturation course was made up with multi-steps in the myosin and two-steps in the paramyosin. The number of free hydrophobic residue and SH group, solubility and protein-protein interaction were significantly differed with the denaturation temperature (p<0.01).

  • PDF

Improvement of Katsuobushi smoking machine for the reduction of benzo(a)pyrene (가쓰오부시 훈연기 개선 및 벤조피렌 저감화)

  • Hong, Ju Hee;Hwang, Sang Min;Lee, Seung Ju
    • Korean Journal of Food Science and Technology
    • /
    • v.49 no.2
    • /
    • pp.162-167
    • /
    • 2017
  • A Katsuobushi smoking machine was developed and evaluated to determine its benzo(a)pyrene reducing effect. The machine was equipped with two heaters for smoking and chamber heating. The smoke-generating system was equipped with a cadmium sulfide (CdS) smoke sensor, an on/off controller, and a rotating feeder with a smoke inlet. Raw bonito was steamed and then smoked under three smoke levels. After smoking at $45^{\circ}C$ for 108 h, the benzo(a)pyrene concentrations were 5.87, 7.83, and $11.41{\mu}g/kg$ at the low, middle, and high smoke levels, respectively. The benzo(a)pyrene concentrations after low-level smoking at 45, 65, and $85^{\circ}C$ for 108 h were 5.87, 4.82, and $3.27{\mu}g/kg$, respectively. Accordingly, the optimal conditions for benzo(a)pyrene reduction were a lower smoke level and higher smoking temperature. These optimal smoking conditions can be implemented with the newly developed machine, but is not possible using a conventional Katsuobushi smoking machine.

A Study on the Confirmation of non-flammabikity of the Cast Resin Mold Transformer in Subway Substation (지하철 변전실용 진공주형형 몰드변압기의 난연성 확인에 관한 연구)

  • 정용기;장성규;곽희로
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.12 no.2
    • /
    • pp.99-107
    • /
    • 1998
  • This dissertationhas confirmed the non-flam mability of cast mold transformer that is increasingly used lately. As a research progress, the investigation has been performed on the installation status and each line of the subway system which have the most mold transformer accidents, and the impediment status of the transformer for rectifier and the high-voltage distribution transformer per each manufacturer. Then, a high voltage mold of the actual mold transformer has been installed in the horiwntal heating furnace and the heat has been applied by the standard heating temperature curve of KSF 2257(Fireproof testing meth od of the construction structures: 1993). Accordingly, the combustibility of the mold transformer based on the test results has been found that 78 minutes has been required for the complete burning per the KSF 2257 combustion test curve and that, after stopping the heat application of the horizontal furnace after ignition, the flame progress has not been made but shown as the self-extinguishing characteristics when the flame progress has been checked. Thus, the non-flammability and self-extinguishability of the mold transformer have been confirmed. The result of this dissertation has indicated that the accident involving mold transformer has been progressed and expanded by the dielectric breakdown or void due to the crack in the mold rather than a fire accident caused by a short-circuit or an overload.r an overload.

  • PDF

Integrated Numerical Analysis of Induction-Heating-Aided Injection Molding Under Interactive Temperature Boundary Conditions (열-유동 상호작용을 고려한 유도가열 적용 미세 사출성형의 통합적 수치해석)

  • Eom, Hye-Ju;Park, Keun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.5
    • /
    • pp.575-582
    • /
    • 2010
  • In recent years, several rapid-mold-heating techniques that can be used for the injection molding of thin-walled parts or micro/nano structures have been developed. High-frequency induction heating, which involves heating by electromagnetic induction, is an efficient method for the rapid heating of mold surfaces. The present study proposes an integrated numerical model of the high-frequency induction heating process and the resulting injection molding process. To take into account the effects of thermal boundary conditions in induction heating, we carry out a fully integrated numerical analysis that combines electromagnetic field calculation, heat transfer analysis, and injection molding simulation. The proposed integrated simulation is extended to the injection molding of a thin-wall part, and the simulation results are compared with the experimental findings. The validity of the proposed simulation is discussed according to the ways of the boundary condition imposition.

Study on control system design for washer fluid heating system (워셔액 가열시스템의 제어시스템 설계에 관한 연구)

  • Lee, Je-Sung;Kim, Jung-Hyun;Won, Jong-Seob;Lee, Seon-Bong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.6
    • /
    • pp.2441-2451
    • /
    • 2012
  • This paper presents the design of a control system for improving performance of a washer fluid heating system (WFHS) which is capable of removing frost, ice, snow and/or other debris from windshield. First, for the WFHS, a modeling process is described, and the extraction of characteristic parameters of the model are made by experimental studies. Design variables that affect on performance of the WFHS are also presented. Secondly, a control system is proposed for improving heating performance of the WFHS, and its performance is verified through experiments. The key feature of the proposed control system is to regulate the current of a booster converter input to the WFHS up to the target value that is set to guarantee heating performance. Target current is calculated by using initial temperature value and employing the mathematical model derived in the paper. Computer simulation and experimental results show that the proposed control system can perform heating operations in a way to satisfy per-determined target performance of the WFHS.

High Temperature Solar Gas Heating by a Compact Fluidized-Bed Receiver of Closed-Type (밀폐형 유동층을 이용한 태양광 고온가스가열 장치의 연구)

  • Choi, Jun-Seop
    • Solar Energy
    • /
    • v.12 no.1
    • /
    • pp.88-94
    • /
    • 1992
  • A small-scale solar collector and tracking system, using a Fresnel lens of $0.5m^2$, and novel compact fluidized-bed solar receiver[FBR] of closed type has been developed for high temperature solar gas heating. The FBR was improved in carrying over of SiC powder and thermo-siphon effect. The maximum outlet air temperature of 1140K and the maximum thermal efficiency of 64% were obtained. The present FBR's operated efficiently at extremely high temperatures in comparison with conventional solar receivers, composed of flat or tubular solid surfaces.

  • PDF

Simulation of the performance characteristics of the double effect Parallel flow cycle with secondary heat at the low temperature qenerator (저온재생기2열원2중효용(低溫再生器2熱源2重效用) Parallel Flow Cycle의 특성(特性) 해석(解析))

  • Choi, K.K.;Rie, D.H.
    • Solar Energy
    • /
    • v.17 no.3
    • /
    • pp.43-49
    • /
    • 1997
  • Cycle simulaton of the double effect parallel flow model is applied to a Lithium-Bromide/water system, with the objective of evaluation the possibilities of effectively utilizing waste-heat as a secondary heat source for the low-temperature generator. In this study, cycle simulation has been carried out to clarify the effect heat exchange in order to predict the performance of absorption refrigeration cycles using waste heat.

  • PDF

전력용 변압기의 tank유도가열 건조 설계 계산

  • 선우학영
    • 전기의세계
    • /
    • v.14 no.3
    • /
    • pp.37-40
    • /
    • 1965
  • 전기기구의 절연성을 향상시킨다는 것은 품질이나 수명을 향상시키는것과 똑같은 의의를 갖는 것이며, 따라서 기기의 수명은 절연성에 있다해도 과언이 아니다. 절연내력을 높이기 위해서는 질량의 절연재료와 고도의 절연가공기술 및 절연구조의 개량등의 요건을 필요로 하나 건조 처리기술에 의하여도 상당히 전기특성을 회복시킬수 있다. 주지의 사항과 같이 건조 처리법에는 열풍건조법, 열유(분무 및 순환) 건조법증기건조법, 전류건조(냉상전류법 및 단락순환건조법)법, 등등에 진공건조를 병용한 처리법이 있으며 어떤나라의 전력계통에서도 계통의 감시 또는 정기보수시 전력용 변압기를 건조(현지)해야 되는 작업은 기기 maker에서 공장건조해야 되는것과 똑같이 거쳐야 하는 공정중의 하나인 것이다. 여기서 언급코져 하는 변압기 tank 유도가열법은 본인이 일본 삼릉전기에서 연수중 조사한 바 있는것으로서 소련, 일본등지에서는 벌써부터 타 건조처리법과 병용해서 척용하고 있으며, 보유하고 있는 건조실의 size가 적을때나 또는 수송 제한조건때문에 현지 조립을 요하는 지역에서는 편리한 처리법의 하나라 할 수 있다. 이하 그 설계 계산법과 설계예를 간략한다.