• Title/Summary/Keyword: 가연한계

Search Result 56, Processing Time 0.021 seconds

Effect of Acoustical Excitation and Flame Stabilizer on a Diffusion Flame Characteristics (음향가진과 보염기형상이 확산화염의 특성에 미치는 영향)

  • Jeon, C.H.;Chang, Y.J.
    • Journal of the Korean Society of Combustion
    • /
    • v.3 no.1
    • /
    • pp.1-10
    • /
    • 1998
  • Lots of techniques are adopted for a flame stabilization and a high-load combustion. But the techniques being used were passive control method which have to change combustor shape like pilot flame, flame stabilizer, pressure profile, etc. Active control method which is not necessary to transform its shape is employed. Acoustical excitation is broadly used for its convenience in changing frequency and intensity. Both acoustical excitation and flame stabilizers were adopted to study their relationship. So, we investigated flammability limits. Flame visualization. And mean temperature in the condition of various frequencies, intensities, and flame stabilizers. As a consequence, flammability limit were advanced in acoustically excited flame at some frequencies. Coherent structure was extended to the downstream region through acoustical excitation and a size of vortice was curtailed. Also width of recirculation zone was magnified. In addition, Effects of acoustical excitation was stood out at 25mm flame stabilizer rather than another ones.

  • PDF

Fuel Stratification Process in a Lean Burn Internal Combustion Engine by Using Planar Laser Induced Fluorescence (PLIF를 이용한 희박연소엔진에서의 연료 성층화에 관한 연구)

  • 정경석
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.11 no.3
    • /
    • pp.7-12
    • /
    • 2003
  • Mixture formation in the cylinder of a lean bum engine has been observed by Laser Induced Fluorescence technique. XeCl laser (308nm) was used to produce a laser sheet. 3-pentanone has been added to iso-octane fuel to produce fluorescence, the intensity of which is proportional to the concentration of the fuel. The laser sheet was introduced through the piston window and the fuel distribution in the vertical plane was observed through a side window. Comparison has been made for the cases of selected fuel injection timing as 0, 360, 405, and 450 CA. For the case of 0 and 360 CA injection, uniform fuel distribution in the combustion chamber has been obtained at the ignition time which is favorable for the high load mode. And the late injection cases, 405 and 450 CA, revealed the stratified formation of rich mixture around the spark plug. That extends the lean misfire limit and reduces cyclic variation in the low load mode.

Flammability Limit and Flame Instability of Nitrogen-Diluted LPG Fuel (질소로 희석된 LPG 연료의 가연한계와 화염 안정성)

  • Ahn, Taekook;Nam, Younwoo;Lee, Kyung-Woo;Lee, Wonnam
    • 한국연소학회:학술대회논문집
    • /
    • 2012.11a
    • /
    • pp.319-321
    • /
    • 2012
  • The flammability limit and the flame instability of nitrogen-diluted LPG fuel was experimentally studied on a co-flow flame configuration. The combustion reaction of nitrogen-diluted hydrocarbon with air could be interpreted as the equivalent reaction of pure fuel with nitrogen-diluted air. Nitrogen-diluted LPG with nitrogen up to 90 % of nitrogen mole fraction in fuel, which is close to the flammability limit, could form a co-flow flame. Various parameters such as laminar or turbulent flame, the existence of diffusion flame with pure fuel, air temperature could affect the limit of flame formation.

  • PDF

A Study on Stability and Performance Characteristics in Aero - Valved Pulsating Combustion System (공기밸브형 맥동연소 시스템의 안정성 및 성능특성에 관한 연구)

  • 임광렬
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.17 no.4
    • /
    • pp.11-19
    • /
    • 1993
  • The experimental study was carried out to investigate the stability and the performance characteristics of the aero-valved pulsating combustion system with maximum operating capacity of 60KW. The effect of geometry of combustion system on the stable condition, the flammability limit, the total pressure oscillation amplitude, and the operating frequency can be identified, and the maximum turn-down-ratio is obtained up to 3.3. The total pressure oscillation amplitude can be controlled by tunning the length of the air inlet pipe. The empirical equation with which the operating frequency can be approximated is proposed and the discrepancy is within 5%. The volumetric efficiency is identified to be one of the important parameters determining the upper flammability limit and the maximum value of which is approximately 22%.

  • PDF

The Effect of DBD Plasma on Hydrocarbon Fuel Reforming and Change in Flammability Limits (DBD 플라즈마 개질에 의한 탄화수소계 연료 화염의 가연한계 변화)

  • Song, Mincheol;Ahn, Taekook;Nam, Younwoo;Park, Sunho
    • 한국연소학회:학술대회논문집
    • /
    • 2015.12a
    • /
    • pp.189-192
    • /
    • 2015
  • An experimental study was conducted to find the effect of DBD plasma on the flammability limits of inert-gas-diluted fuel. The results showed that the concentration of diluting nitrogen at flammability limit increased when nitrogen-diluted methane and propane were reformed by plasma, while it decreased when nitrogen-diluted ethylene was reformed by plasma. Gas chromatography results suggested that the fuel type dependence of flammability limits is due to the difference in the concentrations of hydrogen and hydrocarbon species in reformed fuel.

  • PDF

Discussion of the edge flame structure at the near flammability limits (가연한계 영역에서의 에지 화염 구조 및 고찰)

  • Lee, Min Jung;Jung, Yongjin;Kim, Nam Il
    • 한국연소학회:학술대회논문집
    • /
    • 2015.12a
    • /
    • pp.245-246
    • /
    • 2015
  • In this study, the structure of a edge flame near the flammability limits was explored through several paths approaching the combustion limits of a non-premixed flame: i.e., increase of fuel dilution ratio (FDR), reduction of mean flow velocity and variation of gravity effect. As a result, a unique interesting flame structure was discovered; i.e., a diffusion flame branch was enclosed by two asymmetric premixed flame branches. These structures have been compared for various fuels. Conclusively, each fuel has different flame structure and the meaning of this structure was discussed concerned about our understanding of laminar flame structures.

  • PDF

A Study on an Improvement of the Ignitability Using the High Frequency Ignition System (고주파점화장치를 사용한 착화성 향상에 관한 연구)

  • Lee, Jung-Sun;Gang, Byeong-Mu;Ha, Jong-Ryul
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.1
    • /
    • pp.359-368
    • /
    • 1996
  • For fuel economy and pollutant reduction, the interests in lean burn has increased recently. The purpose of this research is to develop a High Frequency Ignition System (HIS) that can make powerful ignition. We studied relations between performance of HIS and probability of inflammation under various ignition conditions. It is concluded that the portion of capacitance energy to the total energy is comparatively larger and that the optimum spark interval and spark duration are dependent upon conditions of Constant Volume Combustion Chamber.

전기화재(IV) -가연물 취급장소에서 고려하여야 할 정전기 대책-

  • 원종수
    • Fire Science and Engineering
    • /
    • v.2 no.3
    • /
    • pp.47-57
    • /
    • 1988
  • 정전기에 의한 사고가 발생하려면, 정전기의 발생, 착화 능력을 가진 위험한 방전의 발생, 폭발성 가스, 증기가 공기와의 비율에서 폭발 한계 내에 존재할 것 등의 세가지 조건이 필요하다. 따라서 정전기에 의한 착화, 폭발 사고를 방지하기 위해서는 항상 이 세가지 관점에서 검토하여, 어떤 조건 하에서도 3개 조건 중 적어도 하나 이상을 제거하는 것이 필요하다. 이하, 정전기에 의한 재해 중에서 그 방전이 착화원이 되어서 발생하는 가연성 가스 등의 폭발, 화재에 의한 재해의 방지 대책에 한정해서 개설한다.

  • PDF

The Real Scale Fire Test for Fire Safety in Apartment Housing (실물화재실험을 통한 공동주택의 화재안전성 연구)

  • Yoo, Yong-Ho;Kweon, Oh-Sang;Kim, Heung-Youl
    • Fire Science and Engineering
    • /
    • v.23 no.5
    • /
    • pp.57-65
    • /
    • 2009
  • This study was intended to conduct a Real-scale fire test to predict the fire behavior by unit space at the apartment building where a huge casualties and injuries are likely. After setting the inflammables inside the house, the test aimed to identify the fire characteristics to each unit item was carried out. The house was divided into 4 unit space such as kitchen, living room, bedroom and a study for a real scale fire test. As a result, bedroom reached to flashover state in 5minutes after setting the fire, indicating a rapid fire growth such as 7433.3kW of maximum thermal emissivity, 578.6ppm of carbon monoxide, 1.25ppm of carbon dioxide and $1,350^{\circ}C$ of maximum indoor temperature. Particularly, the fire growth was made up to critical temperature which might cause a severe damage to the people within 3minutes, if the fire were not extinguished at inflammable space at the early stage of fire, which stressed the need of early response. The result of a real scale fire test could be compared with the outcome of expanded simulation test and used in predicting the fire spread at the space for different use.

Prediction of Complex Turbulent Flows in Can-type Gas Turbine Combustor and Scroll (원통형 가스터빈 연소기와 Scroll 내부유동장 해석)

  • 김용모;김성구;김명환;민대기
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 1998.04a
    • /
    • pp.9-9
    • /
    • 1998
  • 가스터빈 연소기의 난류유동장을 구성하는 기본적인 유동형태는 크게 밀폐관내의 돌연 확대를 가지는 동축제트, 선회유동, 그리고 연소공기공 및 회석공기공을 통해 연소실에 수직방향으로 유입되는 제트유동 등으로 분류할 수 있다. 실제 가스터빈 연소기내의 난류유동장을 수치해석하기 위해서는 임의의 형상을 갖는 3차원 유동장을 모사할 수 있는 수치해석법과 고차정확도를 유지하면서도 수렴안정성을 만족시키는 대류항 처리기법 등과 같은 수치모델의 개발이 선행되어야 하며, 이와 함께 복잡한 난류연소유동장을 정확히 묘사할 수 있는 난류모델 및 난류연소모델의 개발 및 검증이 가장 중요한 요인이 된다. 또한 가스터빈 연소기의 최적 설계는 넓은 작동구간에서 높은 효율, NOx 및 CO 배기량의 저감, 희박연소 가연한계의 확장, 연소계통에서의 낮은 압력강하, 낮은 연소벽면온도와 온도구배를 유지시키기 위한 공기에 의한 충분한 냉각 같은 서로 상충되는 설계조건을 만족해야 한다. 그리고, 이러한 상충된 연소설계조건들을 충족시키는 최적 연소기의 설계를 위해서는 실험적인 연구뿐만 아니라 연소기내의 물리적인 현상을 잘 반영할 수 있는 물리적 모델을 바탕으로 한 연소유동의 해석적인 연구를 필요로 한다. 본 연구에서는 원통형 가스터빈 연소기의 등온 및 연소유동장, 그리고 연소기와 연결되는 Scroll 내부의 난류유동장에 대한 수치해석을 수행하여 수치 및 물리모델의 예측능력을 검증하였고, 가스터빈 연소유동장 해석에 관련된 중요 논점들에 대하여 심도있게 분석하였다.

  • PDF