• Title/Summary/Keyword: 가압장

Search Result 105, Processing Time 0.028 seconds

The Effect of Heat Sterilization on the Surface Topography and the Tensile Properties in Various Nickel Titanium Wires Including a Korean Product (열멸균과정이 nickel titanium호선의 기계적 성질과 표면상태에 미치는 영향)

  • Kim, Byoung-Ho;Nahm, Dong-Seok;Yang, Won-Sik
    • The korean journal of orthodontics
    • /
    • v.28 no.6 s.71
    • /
    • pp.927-935
    • /
    • 1998
  • The purpose of this study is to investigate the changes of mechanical properties and surface topography of various nickel titanium wires after heat sterilization for recycling with quantitative method. The materials used were four kinds of nickel titanium orthodontic wires including a Korean product. Experimental specimens were treated with two kinds of heat sterilization methods ; dry heat ($180^{\circ}C$, 60min) and autoclave ($121^{\circ}C$, 15-20psi, 30min). Mechanical properties were evaluated by tensile test with Instron 4466 (load cell capacity:.1000 kg, cross head speed:5mm/min, grip distince:40mm in room temperature). Surface topography of various wires was compared with each other qualitatively by using scanning electron microscopy and quantitatively by using profilometer. The findings were analyzed statistically with student t-tests. The results were as follows; 1. Neither method of heat sterilization had any effects on tensile properties of the nickel-titanium wires used in this experiment. 2. Before heat sterilization, the surface smoothness was highest in Optimalloy, followed by Align and Sentalloy, with NiTi showing the lowest smoothness value. 3. In surface topography, Align and Optimalloy were not influenced by heat sterilization. NiTi, on the other hand, had increased roughness after dry heat sterilization and Sentalloy showed the same tendency after each of the two heat sterilization procedures.

  • PDF

A Study on the Circulating Water Purification System using Oxygen Solubilization and Diffusion Device (산소용해수와 확산장치를 결합한 순환형 수질정화 장치의 검증)

  • Ahn, Chang-Hyuk;Song, Ho-Myeon;Joo, Jin-Chul;Lee, Yeon-Ku;Kim, Il-Ho
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2011.05a
    • /
    • pp.318-318
    • /
    • 2011
  • 자연수를 가압(4~5기압)하면서 물과 공기의 비를 4:1~3:1로 혼합하면 수체 내 초미세기포(Diameter $3{\sim}10{\mu}m$)가 발생하는데 이를 산소용해수라 하며 수질정화시설 또는 양식장 등에 널리 사용되고 있다. 산소용해수의 특징은 기포의 비표면적이 넓고 10시간 이상 포화 농도를 유지하여 수체에 잔류하는 시간이 길기 때문에, 일반 산기석을 활용한 포기나 순산소 용해 등의 타 방법과 구별된다. 산소용해수의 산소전달효율은 기존 방법과 큰 차이를 보이기 때문에 실제 적용시에는 대상수를 이용하여 산소전달계수($K_{L}a$)를 사전에 산정할 필요가 있다. 본 연구에서는 한국건설기술 연구원의 안동 수자원 환경실험센터 내 실외형 콘크리트 사각반응수조에 산소용해장치 및 확산장치를 결합한 일체형 시스템을 적용시켜 2010년 9월~2011년 1월의 5개월간 결과를 분석, 본 장치의 $K_{L}a$를 산정 후 수질정화의 활용 면에서 검토하였다. $K_{L}a$의 산정에는 다양한 방법이 이용되나 용존 산소 농도의 제어에 한계가 있는 실외 대형실험장에 적합한 Lewis and Whitman의 Two-film 이론에 근거한 정상포기법을 적용하였다. 체적 $80m^3$의 수조 내에서 현장 유지용수를 대상으로 실험한 결과 산소전달계수는 $0.324\pm0.050$/min, 포화농도는 8.64 mg $O_2$/L, 도달시간은 11 /min이 산정되었으며, 이는 기존 산기석 포기의 산소전달계수 범위인 $0.105\pm0.019$ /min보다 약 3.1배 높은 결과를 보였다. 또한, 확산장치의 수류 순환 방향 및 정도를 검토하기 위하여 실험수조에서 1m단위로 격자를 구성한 후 초음파 유속계로 실측한 결과 0.0~2.5 m/s 의 평면적 유속범위를 도출하였다. 그리고 전체 순환을 고려했을 때 용존산소는 약 8시간 후 8.64 mg $O_2$/L 값에 도달하여 안정화 되었으며, 강한 수류순환과 산소용해수에 의해 하상에 존재하는 퇴적물들의 이송 및 산화촉진을 유도하였다. 이를 근거로 실험수조의 체적과 기준 가동시간인 8시간을 적용시켰을 때, 실험구 수질은 대조구와 비교하여 COD, T-N, T-P가 모두 25~35% 개선되었다. 이 결과는 여과공정 없이 단순 순환만을 고려한 물리적 수질정화 방법의 단독 활용 가능성을 나타내며, 기존 연구에서 나타난 SOD (Sediment oxygen demand) 저감 능력을 감안할 때 향후 폐쇄성 수역의 수질관리에도 효율적으로 활용할 수 있음을 시사한다.

  • PDF

Dewatering of Sewage Sludge by Electrokinetics (동전기를 이용한 슬러지 탈수에 관한 연구)

  • Kim, Ji Tae;Won, Se Yeon;Cho, Won Cheol
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.6B
    • /
    • pp.661-667
    • /
    • 2006
  • In this study, an experiment of sewage sludge dewatering is carried by using electrokinetic method, and the electrokinetic dewatering efficiency of digested sludge is analyzed. Digested sludge without coagulants is selected and gravitational and pressing dewatering methods are applied in combination with electro-osmotic and electro-osmotic pulse technology. After the test of digested sludge, dewatering test of thickened sludge is carried to evaluate the electrokinetic dewatering feasibility of thickened sludge. Under the condition of constantly applied voltage, however, electrical resistance increases with decreasing of water content so that dewatering rate decreases with time. To reduce such a hindrance caused by constantly applied voltage, electro-osmotic pulse technology which is considered to reduce the difference of water content with height, is applied. For the application of electro-osmotic pulse, the dewatered flow rate and the dewatered volume became more increasing from the middle of the dewatering process than that of continuous voltage. Through the test of thickened sludge, electro-osmotic dewatering combined with gravitational and expression also showed high dewatering rate, which proved the possibility of using electrokinetic dewatering.

Evaluation of retrievability using a new soft resin based root canal filling material (레진 계통의 근관 충전재의 제거 용이성에 대한 평가)

  • Shin Su-Jung;Lee Yoon;Park Jeong-Won
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.4
    • /
    • pp.323-329
    • /
    • 2006
  • The aim of this study was to evaluate the retrievability of Resilon as a root canal filling material Twenty-seven human single-rooted extracted teeth were instrumented utilizing a crown down technique with Gates-Glidden burs and ProFile system. In group1 (n = 12) canals were obturated with gutta percha and AH-26 plus sealer using a continuous wave technique and backfilled. In group 2 (n = 15) Resilon was used as a filling material. Then teeth were sealed and kept in $37^{\circ}C$ and 100% humidity for 7 days. For retreatment, the samples were re-accessed and filling material was removed using Gates-Glidden burs and ProFiles. Teeth were sectioned longitudinally to compare the general cleanliness and amount of debris $({\times}\;75)$ using SEM. Chi-square test was used $({\alpha}\;=\;0.05)$ to analyze the data. The total time required for removal of filling materials was expressed as mean ${\pm}SD$ (min) and analyzed by the Student t-test $({\alpha}\;=\;0.05)$, Required time for retreatment was $3.25\;{\pm}\;0.32$ minutes for gutta percha/ AH 26 plus sealer and $3.05\;{\pm}\;0.34$ minutes for Resilon. There was no statistically significant difference between the two experimental groups. There was no significant difference between the groups in the cleanliness of the root canal wall. This study showed that Resilon was effectively removed by Gates-Glidden burs and ProFiles.

Extraction and Characteristics of Purple Sweet Potato Pigment (자색고구마 색소의 추출과 특성)

  • Kim, Seon-Jae;Rhim, Jong-Whan;Lee, Lan-Sook;Lee, Joon-Seol
    • Korean Journal of Food Science and Technology
    • /
    • v.28 no.2
    • /
    • pp.345-351
    • /
    • 1996
  • Studies on extraction and color characteristics of purple sweet potato (PSP) pigment were performed to provide the basic information for the utilization of PSP as a new source of natural food colorant. PSP pigment was extracted well with the polar solvents such as distilled water, ethanol, and methanol. but hardly extracted with the non-polar solvents. Among the tested solvents, 20% ethanol solution containing 0.1% citric acid was found to be the most efficient for extraction of the pigment from PSP. PSP contained high amount of pigment not only in the epidermis but also in the flesh of the potato. The PSP pigment was heat stable even under pretreatments such as autoclaving and blanching of the potato before extraction. The optimum temperature of the extraction for the PSP Pigment was decided to be $30^{\circ}C$ by considering the stability and the rate of extraction. The pigment was markedly influenced by the change of pH. The color of the pigment solution was red at the pH range of $1.0{\sim}3.0$, became blue at $7.0{\sim}8.0$, then turned green at $9.0{\sim}10.0$. A characteristic batho-chromic shift of the pigment solution was observed as the pH of the solution increased.

  • PDF