• Title/Summary/Keyword: 가스 소화설비

Search Result 74, Processing Time 0.022 seconds

A Study on the Possibility of Application as a Natural Extinguishing System for $N_2$ Generator (산업용 질소발생기에 대한 청정소화설비로의 적용가능성에 관한 연구)

  • Suh, Byung-Taek;Jang, Young-Keun
    • Fire Science and Engineering
    • /
    • v.24 no.2
    • /
    • pp.139-144
    • /
    • 2010
  • An experimental study has been carried out to investigate the possibilities of an industrial $N_2$ generator that it replace Halon series as a natural extinguishing system. And this study comparison design standard of gas series extinguishing system with natural extinguishing system. We manufactured simple protected enclosure for analyzing fire-extinguishing performance of the $N_2$ generator. As a $N_2$ gas is exhausted on protected enclosure, a various of Oxygen concentration is measured to analyze fireextinguishing performance experimentally. The results, in case of $100m^3$ protected enclosure and $5m^3$/min $N_2$ flow rate, the Oxygen concentration is decreased below 15% within 3 minutes. And so, the $N_2$ generator make full use of an suffocating extinguishing system.

A study on use of quantitative risk analysis on life safety performance for the effect of fixed fire fighting system at road tunnel fires (정량적 위험성 평가를 활용한 도로터널 화재시 물분무 소화설비의 피난 안전 효과 연구)

  • Park, Kyung-Hwan;Yoo, Ji-Oh
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.14 no.1
    • /
    • pp.1-22
    • /
    • 2012
  • This paper tried to verify whether the fixed fire fighting system (FFFS) that is installed in road tunnel improves evacuation performance or not. Verification was performed according to the Disaster Prevention Facilities Installation and Management Guide at Road Tunnel. Twenty seven different fire scenarios were set up for the verification and the cases that FFFS was installed were compared with the cases that FFFS was not installed. The result of the comparison showed that the average equivalent death was reduced in 26 cases out of 27 cases when water spray extinguishing system was installed. It was confirmed that the risk when was not installed was unacceptable in Hong Kong and the Netherlands. On the other hand, it was confirmed that the risk was reduced to as low as reasonably practicable (ALARP) when was installed. The cumulative frequency of average death in case with FFFS was compared against the frequency of death without FFFS: death of one or more is about 50 times less; 10 or more is about 100 times less; and the death of more than 100 is four times less. It was verified that FFFS makes improved conditions to escape from the fires in road tunnel.

A Study on Percent Agent in Pipe as a Criterion to Evaluate Limitations and Performance of Gaseous Fire Extinguishing Systems (가스계 소화설비의 제한사항 및 성능평가를 위한 배관 내 약제비율에 관한 연구)

  • Son, Bong-Sei;Kim, Hee-Woo
    • Fire Science and Engineering
    • /
    • v.21 no.4
    • /
    • pp.1-11
    • /
    • 2007
  • This study aims to investigate, review, and summarize the definition, development, and applications of "percent agent in pipe", "percent of agent in pipe" which is used as a key factor in testing and evaluating the performance of gaseous fire extinguishing agents, including Halon 1301 and $CO_2$. This study also analyzes and compares the local and international standards on testing and evaluating the performance of gaseous fire extinguishing systems, as well as the results of system performance tests conducted as a part of performance evaluation and approval programs for gaseous fire extinguishing systems, especially, Korean Gaseous Fire Extinguishing System Performance Approval Program called KFI Approval. Percent agent in pipe was defined first in NFPA 12A, Standard on Halon 1301 Fire Extinguishing Systems, dating back to the 1970's. After the phaseout of Halon 1301 systems in 1994 in the developed countries, the percent agent in pipe has been widely used in Halon 1301 alternative clean agent fire extinguishing systems, both halocarbon clean agent systems and inert gas clean agent systems, as an essential criterion to assure the system design accuracy, determine the limitations and performance of a system, and to predict the system performance results accurately, especially, in association with their system flow calculations. Underwriters Laboratories has their own standards such as UL 2127 and 2166 applying percent agent in pipe in testing and evaluating the performance of clean agent fire extinguishing systems. As a part of a system performance test and approval program called KFI Approval System, Korea also has started to apply the percent agent in pipe as a key factor to test, evaluate, and approve the performance of gaseous fire extinguishing systems, including both high and low pressure $CO_2$ systems, from the early 2000's. This study outlines and summarizes the relevant UL and KFI standards and also describes the actual test resultant data, including the maximum percents of agent in pipe for gaseous fire extinguishing systems. As evidenced in lots of tests conducted as a part of the system performance test and approval programs like KFI Approval System, it has been proven that the percent agent in pipe may work as a key factor in testing, evaluating, and determining the limitations and performance of gaseous fire extinguishing systems, especially compared with the hydraulic flow calculations of computer design programs of gaseous fire extinguishing systems, and will remain as such in the future. As one thing to note, however, there are some difficulties in using the unified percent agent in pipe to determine the maximum lengths of pipe networks for gaseous fire extinguishing systems, because the varying definitions used by some of the flow calculations (not in accordance with NFPA 12A definition) make it impossible to do any direct comparison of pipe lengths based on percent agent in pipe.

건축용 배관의 설계, 시공 및 경년변화에 따른 점검보수

  • 백수곤
    • 월간 기계설비
    • /
    • s.88
    • /
    • pp.92-107
    • /
    • 1997
  • 최근의 건축설비는 업무효율을 향상을 위한 기능뿐만 아니라 쾌적한 주거 환경을 보장하기 위한 감성 설계를 중시하게 되었다. 이에 본 난에서는 최적 건축설비 관리를 위한 배관의 설계에서부터 시공, 유지보수에 이르기까지 관련 기술규격을 바탕으로 설명하고자 한다. 건축용 배관에는 급수 및 급탕설비, 위생설비를 포함한 배수설비, 공기조화용 냉난방 설비, 가스설비 및 소화설비용 배관으로 크게 분류할 수 있다. 본 장에서는 건축용 배관중에서 공기조화용 난방설비를 위주로 설명하고자 한다.

  • PDF

건축용 배관의 설계, 시공 및 경년변화에 따른 점검 보수

  • 백수곤
    • 월간 기계설비
    • /
    • s.79
    • /
    • pp.50-64
    • /
    • 1997
  • 최근의 건축설비는 업무효율 향상을 위한 기능뿐만 아니라 쾌적한 주거 환경을 보장하기 위한 감성 설계를 중시하게 되었다. 이에 본 고에서는 최적 건축설비 관리를 위한 배관의 설계에서부터 시공, 유지보수에 이르기까지 관련 기술규격을 바탕으로 설명하고자 한다. 건축용 배관에는 급수 및 급탕설비, 위생설비를 포함한 배수설비, 공시조화용 냉난방 설비, 가스설비 및 소화설비용 배관으로 크게 분류할 수 있다. 본 고에서는 건축용 배관중에서 공기조화용 난방설비를 위주로 설명하고자 한다.

  • PDF

건축용 배관의 설계, 시공 및 경년변화에 따른 점검 보수

  • 백수곤
    • 월간 기계설비
    • /
    • no.spc85
    • /
    • pp.95-104
    • /
    • 1997
  • 최근의 건축설비는 업무효율 향상을 위한 기능뿐만 아니라 쾌적한 주거환경을 보장하기 위한 감성 설계를 중시하게 되었다. 이에 본 난에서는 최적 건축설비 관리를 위한 배관의 설계에서부터 시공, 유지보수에 이르기까지 관련 기술규격을 바탕으로 설명하고자 한다. 건축용 배관에는 급수 및 급탕설비, 위생설비를 포함한 배수설비, 공기조화용 냉난방설비, 가스설비 및 소화설비용 배관으로 크게 분류할 수 있다. 본 장에서는 건축용 배관중에서 공기조화용 난방설비를 위주로 설명하고자 한다.

  • PDF

건축용 배관의 설계, 시공 및 경년변화에 따른 점검 보수

  • 백수곤
    • 월간 기계설비
    • /
    • s.86
    • /
    • pp.100-108
    • /
    • 1997
  • 최근의 건축설비는 업무효율 향상을 위한 기능뿐만 아니라 쾌적한 주거 환경을 보장하기 위한 감성 설계를 중시하게 되었다. 이에 본 란에서는 최적 건축설비 관리를 위한 배관의 설계에서부터 시공, 유지보수에 이르기까지 관련 기술규격을 바탕으로 설명하고자 한다. 건축용 배관에는 급수 및 급탕설비, 위생설비를 포함한 배수설비, 공기조화용 냉난방설비, 가스설비 및 소화설비용 배관으로 크게 분류할 수 있다. 본 장에서는 건축용 배관중에서 공기조화용 난방설비를 위주로 설명하고자 한다.

  • PDF

건축용 배관의 설계, 시공 및 경년변화에 따른 점검 보수

  • 백수곤
    • 월간 기계설비
    • /
    • s.84
    • /
    • pp.78-93
    • /
    • 1997
  • 최근의 건축설비는 업무효율 향상을 위한 기능뿐만 아니라 쾌적한 주거환경을 보장하기 위한 감성 설계를 중시하게 되었다. 이에 본 난에서는 최적 건축설비 관리를 위한 배관의 설계에서부터 시공, 유지보수에 이르기까지 관련 기술규격을 바탕으로 설명하고자 한다. 건축용 배관에는 급수 및 급탕설비, 위생설비를 포함한 배구설비, 공기조화용 냉난방설비, 가스설비 및 소화설비용 배관으로 크게 분류할 수 있다. 본 장에서는 건축용 배관중에서 공기조화용 난방설비를 위주로 설명하고자 한다.

  • PDF