• Title/Summary/Keyword: 가스유해성 시험

Search Result 39, Processing Time 0.025 seconds

A Study on the Refractory Performance Verification of the Thermal Insulators for AES Ducts and Piping (AES 계열 덕트·배관 단열재의 내화성능 검증에 관한 연구)

  • Kwang-Ho Ham;Jea-Chun Sa;Joo-Hwan Lee;Se-Hong Min
    • Journal of the Society of Disaster Information
    • /
    • v.20 no.2
    • /
    • pp.419-429
    • /
    • 2024
  • Purpose: To enhance the non-combustibility of fire protection piping insulation and improve the heat resistance of smoke extraction duct insulation, I plan to verify the suitability of AES insulation materials for these applications through performance testing. Method: The non-combustibility, heat resistance, and thermal insulation performance of AES insulation materials will be verified through various tests. Result: According to the 'Standards for Flame Retardancy and Fire Spread Prevention of Building Finishing Materials,' the results of non-combustibility and gas toxicity tests confirmed the non-combustible properties. The standard fire resistance tests verified the fire resistance performance. Additionally, the thermal insulation performance was confirmed through building insulation tests. Conclusion: As the performance tests on AES inorganic insulation materials have proven their noncombustibility, fire resistance, and thermal insulation performance, these materials are considered a viable alternative for improving fire spread prevention in buildings.

A Rigorous Examination of the Interplay Between Fire Resistance of 1-Hour Rated Fireproof Steel Walls and the Flexural Strength of Individual Panels (1시간 내화구조용 철강재 벽체의 내화성능과 단위 패널 휨강도의 관계 고찰)

  • Jeon, Soo-Min;Ok, Chi-Yeol;Kang, Sung-Hoon
    • Journal of the Korea Institute of Building Construction
    • /
    • v.23 no.5
    • /
    • pp.537-546
    • /
    • 2023
  • For the purpose of fire delineation within buildings, steel walls in Korea are mandated to undergo rigorous certification as fire-resistant entities, substantiated via a series of qualitative assessments. Predominantly, these evaluations comprise the fire resistance test paired with supplementary examinations; specifically for steel walls, these encompass the gas hazard and panel bending strength tests. Given the prevalence of semi-noncombustible core materials, gas hazard tests are largely rendered superfluous, pivoting the focus solely onto the panel bending strength test during the certification trajectory. This particular test is designed to gauge the flexural robustness of individual wall panels. An enhanced bending strength is postulated to fortify both the structural integrity and thermal insulation of the wall by mitigating potential deformations. In this scholarly exploration, an analytical deep dive was undertaken into extant, valid certification test datasets. The endeavor aimed to ascertain the depth of correlation between the designated fire resistance metric and the bending strength, the latter being the sole supplementary assessment for steel walls. In distilling the findings, it was discerned that temperature elevations beyond baseline values exhibited no statistically salient linkage with the panel's bending strength.

A Study on Combustion Characteristics of Fire Retardant Treated Pinus Densiflora and Pinus Koraiensis (난연처리된 소나무와 잣나무의 연소특성 연구)

  • Choi, Jung-Min
    • Journal of the Korean Wood Science and Technology
    • /
    • v.39 no.3
    • /
    • pp.244-251
    • /
    • 2011
  • The combustion characteristics were evaluated for Japanese Red Pine (Pinus Densiflora) and Korean Pine (Pinus Koraensis). These two species are widely used as building member of Korea-style house and volume density of Japanese Red Pine is relatively higher than that of Korean Pine. The combustion characteristics are closely connected with volume density. The differences of two species in both total heat release (THR) and average heat release rate (HRR) seemed to be resulted from the volume density. Toxicity of smoke from the specimens was increased because of fire-retardant treatment.

A Study on the Cone Calorimeter Evaluation Method of Sandwich Panels (복합자재 콘칼로리미터평가방법에 대한 연구)

  • Park, Jung-Woo;Cho, Nam-Wook
    • Fire Science and Engineering
    • /
    • v.31 no.6
    • /
    • pp.74-82
    • /
    • 2017
  • Fires in buildings built using sandwich panels are difficult to extinguish, and the damage caused by the fire spreading through the inner core material is extensive. Sandwich panels consist of a nonflammable material on both sides of an insulation material. The types of insulation material include organic and inorganic insulation materials, but the former are used in more than 80% of the case. Organic insulation is economically advantageous compared to inorganic insulation, but it is vulnerable to fire. Therefore, the damage caused by sandwich panel fires is higher than that for general fires. In the case of the noxious gas analyzer test, the panel is tested with three round holes having a diameter of 25 mm, in order to determine the risk of the core material, but the cone calorimeter test is carried out using a sandwich panel. In this study, the cone calorimeter test was conducted to examine the fire risk of the composite material when heated on a nonflammable surface, exposed to the core material through a hole, and heated directly the core material. The type of organic insulation employed was flame retardant EPS (Expanded Polystyrene), and the test specimens were tested in three types of sandwich panel, a perforated sandwich panel and single core material. The purpose of this study is to propose a method of measuring the fire risk of the core materials of composite materials using the cone calorimeter test.

Analysis of Applicability of Rapid Hardening Composite Mat to Railway Sites (초속경 복합매트의 철도현장 적용성 분석)

  • Jang, Seong Min;Yoo, Hyun Sang;Oh, Dong Wook;Batchimeg, Banzragchgarav;Jung, Hyuk Sang
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.44 no.1
    • /
    • pp.109-116
    • /
    • 2024
  • The Rapid Hardening Composite Mat (RHCM) is a product that improves the initial strength development speed of conventional Geosynthetic Cementitious Composite Mats (GCCM). It offers the advantage of quickly securing sufficient strength in railway slopes with insufficient formation level, and provides benefits such as preventing slope erosion and inhibiting vegetation growth. In this study, an analysis of the practical applicability of RHCM in railway settings was conducted through experimentation. The on-site applicability was assessed by categorizing it into fire resistance, durability, and stability, and conducting combustibility test, ground contact pressure test, and daily displacement analyses. In the case of South Korea, where a significant portion of the territory is composed of forested areas, the prevention of slope fires is imperative. To analyze the fire resistance of RHCM, combustibility tests were conducted as an essential measure. Durability was assessed through ground contact pressure tests to analyze the deformation and potential damage of RHCM caused by the inevitable use of small to medium-sized equipment on the construction surface. Furthermore, daily displacement analysis was conducted to evaluate the structural stability by comparing and analyzing the displacement and behavior occurring during the application of RHCM with railway slope maintenance criteria. As a result of the experiments, the RHCM was analyzed to meet the criteria for heat release rate and gas toxicity. Furthermore, the ground contact pressure was observed to be consistently above 50 kPa during the curing period of 4 to 24 hours under all conditions. Additionally, the daily displacement analyzed through field site experiments ranged from -1.7 mm to 1.01 mm, confirming compliance with the criteria.

Development of Vortex Scrubber Using Electrolyzed Water for the Removal Efficiency Improvement of Minute Particles and Odor (미세분진 및 냄새제거 효율향상을 위한 선회류식 세정전해 기술개발)

  • Kim, Nor-Jung;Lim, Seong-Il;Kim, Sun-Mi;Kim, Sun-Uk;Kim, Lae-Hyun;Kim, Sun
    • Journal of the Korean Institute of Gas
    • /
    • v.14 no.3
    • /
    • pp.1-7
    • /
    • 2010
  • According to Indoor Air Quality(IAQ) management law for multi-use buildings, SEEONE CO., Ltd. made pilot and tested it to remove minute particle, odor, VOCs, etc. within the standards of IAQ. This pilot made by SEEONE CO., Ltd. is vortex scrubber washing electrolyzed water. As 30 minutes test result in multi-use building indoor place, minute particle(the smoke of a cigarette) was reduced $920{\mu}g/m^3{\rightarrow}112{\mu}g/m^3$, gaseous contaminants was reduced Formaldehyde (HCHO) 20ppm$\rightarrow$4ppm, Ammonia($NH_3$) 50ppm$\rightarrow$1ppm, Trimethylamine ($(CH_3CH_2)_3N$) 15ppm$\rightarrow$trace, Methylethylketone($CH_3COC_2H_5$) 25ppm$\rightarrow$trace, Acetic acid ($CH_3COOH$) 20ppm$\rightarrow$trace, Acetaldehyde($CH_3CHO$) 15ppm$\rightarrow$2ppm and Acetone($CH_3COCH_3$) 50ppm$\rightarrow$N.D. The pilot test result of the air filter using electroyzed water in vortex scrubber showed high removal efficiency. Because purified air maintain indoor humidity of approximately 40~60%, so users can feel pleasant. In E.coli, S.aureus sterilization test and CODcr, turbidity treatment test by electrolysis, germs was sterilized over 99.99% and CODcr and turbidity was decreased gradually. So water used for washing can be reused by electrolysis.

Research on the Architectural Applications of High-Performance Vacuum Insulation Panel (고성능 진공단열재의 건축적인 적용에 관한 연구)

  • Kwon, Young Cheol;Kim, Suk
    • Land and Housing Review
    • /
    • v.10 no.3
    • /
    • pp.23-32
    • /
    • 2019
  • Vacuum Insulation Panel(VIP) has the lowest thermal conductivity among present insulations. It is composed of envelope, core material and getter. Aluminum film is usually used as the envelope of VIP, and it is important component to decide the useful life of VIP. In this research, the thermophysical properties of incombustible fiber glass core VIP were investigated with the possibility of its architectural applications. The results of this research can be summarized as follows: 1) The thermal conductivity of 20mm-thick fiber glass core VIP is resulted as 0.00177W/m·K, which means that 20mm-thick VIP can meet all the reinforced insulation guideline and it can be used in any envelope of any region in Korea. 2) As a result of the test of incombustion and gas toxicity, fiber glass core VIP was suitable for incombustible material. 3) As the test result for the long term thermal conductivity, fiber glass core VIP was found out that it would keep above 10 times insulating performance than polystyrene foam and glass fiber. 4) To meet the thermal transmittance of 0.12W/㎡K, limited-combustible insulation of expanded polystyrene foam and phenolic foam should be used respectively as thick as above 280mm and 170mm, incombustible VIP can meet the same insulation level with 20mm thickness. 5) The price competitiveness of incombustible VIP to meet the thermal transmittance of 0.12W/㎡·K was about 1,500won/㎡ higher than that of phenolic foam.

DNA damages with Fpg/Endo Ⅲ FLARE Assay in cynomolgus monkeys exposed to stainless steel welding fume (용접흄 흡입노출 영장류에서 Fpg/Endo Ⅲ FLARE Assay를 이용한 DNA 손상 및 회복)

  • Rim, Kyung Taek;Kim, Soo Jin;Chung, Yong Hyun;Kim, Hyeon Yeong;Maeng, Seung Hee;Yu, Il Je
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.17 no.4
    • /
    • pp.272-281
    • /
    • 2007
  • 선박제조업을 비롯한 운송업 및 건축업 등의 다양한 분야에서 용접기술이 이용되어 옴에 따라 용접근로자들에 대한 산업보건학적 관심이 높아지고 있다. 노출정도가 다양하기는 하지만 용접흄은 6가 크롬을 비롯한 금속화합물과 유해가스, 화학물질 등을 복합적으로 포함하고 있는 스테인레스 스틸 용접흄에 대한 유전독성영향을 평가하기 위하여 흡입챔버를 이용, 실험동물인 영장류에 스테인레스 스틸 용접흄을 노출시키고 혈액 내 lymphocytes에 생성된 용접흄 노출농도 및 시간별 DNA 손상정도 및 그 회복효소를 측정함으로써, 유해성이 완전하게 확인되지 않은 용접흄에 노출되어 나타날 수 있는 암을 비롯한 심각한 건강영향을 예방하기 위한 각 지표들을 찾아 그 유용성을 비교하고자 하였다. 영장류를 노출시키기 위해 robotic arm을 장치한 영장류 흡입노출 시스템을 개발하였으며, 이 노출 시스템을 이용하여 수컷 영장류 6마리에 대해 용접흄 노출시험을 실시하였는데 실험군은 대조군 2, 저농도 ($31mg/m^3$) 노출군 2, 고농도 ($63mg/m^3$) 노출군 2마리로 구성하였고, 1일 2시간씩 일주일에 5일 동안 용접흄에 노출시켰다. 노출 농도는 지속적으로 모니터링 하였고, 노출과정 중에 영장류의 혈액을 채취하여 lymphocytes를 분리, 단세포 DNA 손상을 선별하기 위해 DNA 손상회복 효소인 E. coli formamidopyrimidine-DNA glycosylase (Fpg)와 endonuclease Ⅲ (Thymine Glycol-DNA glycosylase) 투여와 Comet asaay (single cell gel electrophoresis, 단세포겔전기영동기법)를 결합시켜 이용하는 Fpg/Endo III FLARE 분석법을 사용하였다. Fpg enzyme에 의한 olive tail moment값의 변화는 16주 노출군부터 노출부검(34주)군 까지 노출농도가 높아짐에 따른 olive tail moment 기하평균 값의 양 반응관계를 보기는 어렵지만, 고농도군의 경우 27주 노출군에서 가장 높은 olive tail moment 값을 보이고 이후 차츰 감소하였다. 한편 16주에서 22주까지의 노출기간에서는 대조군에 비해 노출군에서 DNA손상정도(olive tail moment값)는 모두 유의하게 높았으나, 6, 12, 18, 25, 31, 33, 35주간 노출하였을 때는 다른 결과를 보였다. 각 실험군의 Fpg enzyme에 의한 tail length값의 분포를 살펴볼 때, 저농도군 및 고농도군에서 27주간 노출하였을 때 가장 높은 tail length 값을 보이고 이후 차츰 감소하는 경향을 보였다. 또한 16, 22주간 노출하였을 때 대조군에 비해 노출군에서 tail length 값이 유의하게 높았으나, 20주간에서만 양 반응관계가 관찰되었고, 다른 주간에서는 양 반응 및 기간 반응관계를 나타내지는 않았다. Endo III enzyme에 의한 olive tail moment값의 변화는 기간별 노출군에서 대조군에 비해 높은 DNA손상정도(olive tail moment값)를 나타내는 결과들이 있었지만, 10, 12, 16, 22, 25, 31주간 노출하였을 때 등 상당수 노출기간에서 반응관계를 나타내지는 않았다. 각 실험군의 Endo III enzyme에 의한 tail length값의 분포를 살펴볼 때, 18, 20, 27, 33주간 노출하였을 때 대조군에 비해 노출군에서 tail length 값이 조금 높았지만, 양 반응 및 기간 반응관계를 보이지 않았고 수치의 크기가 불규칙하게 변화하였다. 즉, DNA에 있어 산화된 pyrimidine을 형성하여 손상된 부위의 염기를 제거함으로써 AP site (abasic site)를 만들고 이들이 Comet assay를 통해 break로 전환된 것을 포함한 DNA손상을 측정하기 위하여 endonuclease III (Endo III)를 첨가시킨 Endo III FLARE 분석법을 실시한 결과, 본 연구에서 나타난 결과는 용접흄 노출 영장류에서 Olive tail moment 및 tail length 공히 노출량 및 노출기간 반응관계를 볼 수 없었다. Endo III FLARE 분석법을 통한 산화적 DNA 손상지표는 영장류에 적용하기에는 적응반응현상으로 대조군과 유의한 차이도 관찰할 수 없었고 더욱이 역으로 대조군에서의 자연발생적 수치가 더 높아질 수 있어 용접흄 노출 영장류의 모니터링 지표로 사용하기에는 제한점이 있었다.

Research on Radiation Shielding Film for Replacement of Lead(Pb) through Roll-to-Roll Sputtering Deposition (롤투롤 스퍼터링 증착을 통한 납(Pb) 대체용 방사선 차폐필름 개발)

  • Sung-Hun Kim;Jung-Sup Byun;Young-Bin Ji
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.3
    • /
    • pp.441-447
    • /
    • 2023
  • Lead(Pb), which is currently mainly used for shielding purposes in the medical radiation, has excellent radiation shielding functions, but is continuously exposed to radiation directly or indirectly due to the harmfulness of lead itself to the human body and the inconvenience caused by its heavy weight. Research on shielding materials that are human-friendly, lightweight, and convenient to use that can block risks and replace lead is continuously being conducted. In this study, based on the commonly used polyethylene terephthalate (PET) film and the fabric material used in actual radiation protective clothing, a multi-layer thin film was realized through sputtering and vacuum deposition of bismuth, tungsten, and tin, which are metal materials that can shield radiation. Thus, a shielding film was produced and its applicability as a radiation shielding material was evaluated. The radiation shielding film was manufactured by establishing the optimized conditions for each shielding material while controlling the applied voltage, roll driving speed, and gas supply amount to manufacture the shielding film. The adhesion between the parent material and the shielding metal thin film was confirmed by Cross-cut 100/100, and the stability of the thin film was confirmed through a hot water test for 1 hour to measure the change of the thin film over time. The shielding performance of the finally realized shielding film was measured by the Korea association for radiation application (KARA), and the test conditions (inverse wide beam, tube voltage 50 kV, half layer 1.828 mmAl) were set to obtain an attenuation ratio of 16.4 (initial value 0.300 mGy/s, measured value 0.018 mGy/s) and damping ratio 4.31 (initial value 0.300 mGy/s, measured value 0.069 mGy/s) were obtained. by securing process efficiency for future commercialization, light and shielding films and fabrics were used to lay the foundation for the application of films to radiation protective clothing or construction materials with shielding functions.