• Title/Summary/Keyword: 가스분사 시스템

Search Result 134, Processing Time 0.021 seconds

The Effect of Cleaning the Intake System of LPG Vehicles on Engine and Emissions (LPG차량 흡기계통 Cleaning이 엔진 및 배출가스에 미치는 영향)

  • Hong, Sung-In;Lee, Seung-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.3
    • /
    • pp.1229-1235
    • /
    • 2014
  • At the LPG vehicle air intake system, most of dust particles in the air cleaner are removed. However very small particles are not removed and accumulated. The accumulation of carbon in air intake system is going to affect the idle speed control and sensor signal. It also causes engine chattering and transmission troubles of automatic transmission. This is study about cleaning up intake system using cleaning chemical. We can clean up the intake system by spraying cleaning liquid onto intake device when the engine is idling after intake hose is removed from warmed up vehicle. We can obtain the following experimental results by cleaning up ISC, surge tank, intake manifold, intake valves and combustion chamber. According to this results, the stroll valve works correctly and power rate of engine is up to the standard, it is smoothy to control the idling speed when a vehicle pulls up. After cleaning up CO grow down about 0.15%, HC does about 20~100 ppm.

An Experimental Study on Individual HC Emission Characteristics and Startability for Various Composition Ratio of LPG Fuel on LPLi Engine (LPLi엔진에서의 LPG 연료 조성비가 개별탄화수소 배출특성과 시동성에 미치는 영향에 대한 연구)

  • Choi, Seong-Won;Kwak, Ho-Chul;Myung, Cha-Lee;Park, Sim-Soo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.3 s.258
    • /
    • pp.234-241
    • /
    • 2007
  • The regulations for hydrocarbon emission from vehicles have become much more stringent in recent years. These more stringent regulations request vehicle manufacturers to develop the advanced exhaust system for reducing exhaust emissions. The exhaust emissions has many sources in vehicle. In order to investigate the characteristics of hydrocarbon(HC) in the exhaust manifold, concentrations of individual HC species were measured in exhaust process. Using sampling valve, the light hydrocarbon emissions were captured in the exhaust manifold(catalyst before and after) and analyzed from LPLi engine exhaust manifold(catalyst before and after) using different fuel properties. Then exhaust samples were measured by gas chromatography(GC) and exhaust gas analyzer. Catalyst conversion efficiency for fuel properties of Butane 100% was better than Propane 100%. Start delay of LPLi engine was observed as increment of propane contents in LPG fuels.

A Study on the Demonstration of Yellow Plume Elimination System from Combined Cycle Power Plant Using Liquid Injection System (액상 직분사 시스템을 이용한 복합화력 황연제거 실증 연구)

  • Lee, Seung-Jae;Kim, Younghee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.10
    • /
    • pp.317-324
    • /
    • 2020
  • Combined cycle power plants (CCPP) that use natural gas as fuel are easier to start and stop, and have lower pollutant emissions, so their share of domestic power generation facilities is steadily increasing. However, CCPP have a high concentration of nitrogen dioxide (NO2) emission in the initial start-up and low-load operation region, which causes yellow plume and civil complaints. As a control technology, the yellow plume reduction system was developed and operated from the mid-2000s. However, this technology was unable to control the phenomenon due to insufficient preheating of the vaporization system for 10 to 20 minutes of the initial start-up. In this study, CFD analysis and demonstration tests were performed to derive a control technology by injecting a reducing agent directly into the gas turbine exhaust duct. CFD analysis was performed by classifying into 5 cases according to the exhaust gas condition. The RMS values of all cases were less than 15%, showing a good mixing. Based on this, the installation and testing of the demonstration facilities facilitated complete control of the yellow plume phenomenon in the initial start-up.

A Study on the Fine Dust Removal Equipment of Pressurized Water type for the Removal of Exhaust Gas Fine Dust and Volatile Organic Compounds from the Non-industrial combustion plant (비산업 연소 사업장 배출 가스상 미세먼지와 휘발성 유기 화합물 제거를 위한 가압수식 미세먼지 제거 장치 연구)

  • Youn, Jae-Seo;Kim, Sang-Min;Lee, Ye-Ji;Noh, Seong-Yeo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.11
    • /
    • pp.506-512
    • /
    • 2018
  • The fine dust generated in the home and restaurant business occupies a low ratio of about 4% of the total fine dust emissions. However, at the foodservice business, the rate of change of the pollutant concentration is very high, so that the temporary fine dust concentration can be measured up to 60 times. The pollutants generated from non-industrial combustion plants consist of particulate fine dust and gaseous organic compounds. To remove these pollutants, cleaning dust collection system, which is an effective system for simultaneous removal of gaseous and particulate matter, is applied. This is a method of increasing the probability of diffusion capture of the Brownian motion by pressurized liquid injection method using the atomizing nozzle. The dust removal efficiency of the fine dust collecting system was analyzed by nozzle spraying air pressure condition and angle using the manufactured fine dust removing system. As a result, it was confirmed that the efficiency of removal of fine dust and gaseous organic compounds was more than 90%. The developed system is expected to be highly usable in the future because it can remove particulate dust from the existing plant hood system without any installation cost.

Study on the fuel rail temperature and pressure characteristics with LPG composition during hot restart condition of LPi engine with turbine type pump (터빈방식 펌프 LPi연료공급 시스템의 엔진 고온재시동 시 LPG 조성비에 따른 연료레일에서의 압력 및 온도특성에 관한 연구)

  • Lee, Kang-Ju;Kim, Ju-Won;Myung, Cha-Lee;Park, Sim-Soo
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.3323-3328
    • /
    • 2007
  • Conventional LPG pump for Liquified Petroleum injection(LPi) engine has been adopted vane type. But the BLDC type fuel pump for LPi system has complicated structure and its price is high. Therefore, as a alternative, this study has mainly focused on the development of turbine type LPG pump which has lower cost and simple structure than conventional BLDC type. To verify the possibility of substitute the performance tests were performed for each fuel pump. The comparative items were pressure settling time, variation of fuel outlet temperature and engine performance of hot restart ability. As a result, performances of turbine type LPG pump were equivalent or high comparing to the BLDC type all over the tests for different fuel composition.

  • PDF

Development of a Bio-gas Engine (I) - Components and System Design & Manufacturing - (Bio-gas 엔진 개발에 관한 연구 (I) - 부품 및 시스템 설계.제작 -)

  • Paek, Y.;Yu, Y.S.;Kim, Y.J.;Kang, G.C.;Cho, K.H.;Lee, J.T.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2003.07a
    • /
    • pp.407-412
    • /
    • 2003
  • 지구환경보존이 세계적인 과제로 되어있는 오늘날 디젤엔진으로부터 배출되는 배기배출물에 대한 문제가 대두되고 있으며, 미국의 캘리포니아주(CARB)에 있어서는 세계최초로 농업기계용 엔진을 포함한 운송용 엔진에 대하여 엄한 배기가스 규제법안을 세워 시행중에 있다. 또한 전미, 유럽 및 일본에 동일한 검사가 이루어지고 있는 실정이다. 따라서, 디젤엔진으로서 문제가 되고 있는 배기성분인 NOx와 파라큘레이트(PM)에 대한 저감대책으로 최근 고압분사(HSDI), EGR 및 후처리(De-NOx) 촉매등의 연구가 시행되고 있으며, 전망이 기대되어지고 있다. 그러나 경제성, 내구성, 제품의 크기, 차량의 중량증가 등이 과제로 남겨지고 있다(유강택 외 1997). (중략)

  • PDF

Emission Analysis in Catalytic Converter Adopted Secondary Air Injection System for Cold Start Period (2차 공기 공급 시스템을 채택한 촉매 변환기 내 냉 시동 구간 배기가스 해석)

  • Yun, Jeong-Eui
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.18 no.6
    • /
    • pp.46-52
    • /
    • 2010
  • In this paper, emission analysis during cold start period of CVS-75 mode in LPG vehicle was performed to find out proper operating conditions of SAI(Secondary Air Injection) system. In order to meet SULEV target, the simulated emission system had a SAI system as well as a MCC(Manifold Catalytic Converter) and a UCC(Under body Catalytic Converter). Using commercial 1-D code AMESIM, in which 7 step global surface chemical reactions of Langmuir-Hinshelwood type were adopted, transient emission analysis in the exhaust system during cold start period of CVS-75 mode were carried out to figure out the effects of flow rate, duration of supply air on HC, CO, NO emission.

Exergy Analysis of Regenerative Gas Turbine Systems with Afterfogging (압축기 출구 물분사가 있는 재생 가스터빈 시스템의 엑서지 해석)

  • Kim, Kyoung-Hoon;Ko, Hyung-Jong;Kim, Se-Woong
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.13 no.1
    • /
    • pp.31-39
    • /
    • 2010
  • An exergy analysis is carried out for the regenerative gas turbine cycle which has a potential of enhanced thermal efficiency and specific power owing to the more possible water injection than that of inlet fogging under the ambient conditions. Using the analysis model in the view of the second law of thermodynamics, the effects of pressure ratio, water injection ratio and ambient temperature are investigated on the performance of the system such as exergetic efficiency, heat recovery ratio of recuperator, exergy destruction or loss ratios, and on the optimal conditions for maximum exergy efficiency. The results of computation for the typical cases show that the regenerative gas turbine system with afterfogging can make a notable enhancement of exergy efficiency.

  • PDF

An investigation of LPG fuel supply method for Liquid phase LPG injection system (LP가스연료 액상공급시스템 특성연구)

  • Kim, C.U.;Oh, S.M.;Choi, S.J.;Kang, K.Y.
    • Journal of ILASS-Korea
    • /
    • v.9 no.2
    • /
    • pp.18-23
    • /
    • 2004
  • An experimental studies of conventional gasoline fuel pump were carried out to obtain fundamental data fur liquid phase LPG injection(LPLi) system. A regenerative type and a roller-vane type of pumps were investigated in various operational condition. The experiments were performed to obtain flow rate of LPG fuel as a function of pressure differences and temperatures. The regenerative pump had too low flow rate at some experimental conditions to use this pump system for LPLi fuel supply system. On the other hand, the roller-vane type pump can be applied to the system only if its check valve is modified. Cavitation might occur in this system which can result in system noise, flow rate variation, and pump durability problem. To solve these problems the system is needed to increase $NPSH_{re}$(required net positive suction head).

  • PDF

Implementation of Smart Fire Safety System (스마트 화재 안전 시스템의 구현)

  • Duk-Kyu Choi;Yun-Ho Kang;Min-Sung Jang;Ju-An Son;Hee-Jun Seo;Hyeon-Gyu Lee;Jin-Ho Kim
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2023.01a
    • /
    • pp.279-280
    • /
    • 2023
  • 소방청 국정감사에서 2020년 전국 자동화재속보설비 화재신고 32,764건 가운데 32,685건이 오작동으로 출동해 소방서 출동의 99.8%가 헛걸음이었다. 그리고 화재가 발생할 경우 화재경보장치와 대피경로를 안내하는 비상등이 미흡하고, 화재 연기가 제거되지 않아 대피가 힘들어질 뿐만 아니라 미처 대피 못한 인원을 파악하는 등의 신속한 대처가 힘들다. 본 논문은 화재 상황에서 피해를 최소화하기 위한 '스마트 화재 안전 시스템' 기술을 제안한다. 화재가 발생할 경우, 대피 경로를 안내하는 유도등 작동 및 경보음과 LED의 작동으로 화재발생을 경고하여 신속한 대처를 할 수 있게 도와주고, 문과 창문의 자동 개방 및 환기팬 작동으로 인한 유해가스를 환기시켜 준다. 그리고 스프링클러 작동과 소화제를 자동 분사하여 화재의 번짐 등 2차 피해를 예방하여 준다. 또한, 자동 신고 기능으로 더욱 빠르게 화재를 진압할 수 있게 도와주기 때문에 피해를 최소화할 것이다.

  • PDF