• Title/Summary/Keyword: 가스교환계수

Search Result 13, Processing Time 0.029 seconds

A Study on the Performance of a Cross-Flow Beat Exchanger by Tube Array Change (튜브배열 변화에 따른 직교류형 열교환기의 성능에 관한 연구)

  • Jeon Yong-Han;Kim Nam-Jin;Kim Chong-Bo
    • Journal of Energy Engineering
    • /
    • v.15 no.1 s.45
    • /
    • pp.28-34
    • /
    • 2006
  • The convective heat transfer on the outer surface of tube arrays perpendicular to the flow direction was experimentally investigated. The test sections which include the aligned and staggered arrangements were made and the local heat transfer coefficients on the outer surface of the tube were measured after the Hour has been fully developed. The results showed that the local heat transfer coefficients of the staggered arrangement, which has transverse pitch of 0.075 m and longitudinal pitch of 0.08 m, were about 15% greater than that of the aligned arrangement. Also, the overall mom Nusselt number of the former was greater thu that of the latter.

A Numerical Study on Fuel Concentration Distribution in a FBC (유동층 연소로내 연료농도분포의 수치적 연구)

  • Lee, D.I;Park, S.H.;Shin, D.S.
    • Journal of the Korean Society of Combustion
    • /
    • v.3 no.1
    • /
    • pp.41-48
    • /
    • 1998
  • A numerical study on combustion in a fluidized bed is based on three dimensional mixing and dispersion phenomena in the bed owing to the bubble growth in the vertical direction. As fluidizing velocities increase, bubble diameters increase, which activates the fuel dispersion in the bed. The combustion rates, however, reduce due to the decrease of gas exchange rates between bubble and emulsion phases. Fuel distributions in the bed are dependent on fluidizing velocities, equivalence ratios, fuel particle diameters, fuel feeding points, and the number of fuel feeders.

  • PDF

A Theoretical Analysis on Pressure Loss and Gas Volumetric Fraction of Gas-Liquid Two-Phase Flow (기액이상류의 압력손실과 가스상의 체적분율에 관한 이론적 해석)

  • Choi, Bu-Hong
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.15 no.1
    • /
    • pp.63-69
    • /
    • 2009
  • Gas volumetric fractions and pressure loss are very important parameters in understanding and predicting gas-liquid two-phase flows. They are also essential to design large heat exchanging system in many industries, boiler and refrigerating systems mounted at ships. This paper therefore presents a theoretical method of predicting the pressure loss and gas volumetric fractions in gas-liquid two-phase flows for the whole range of pipe inclinations. The theoretical analysis is based on the two-fluid stratified flow model. It also provides the results of the comparisons between this theoretical analysis results and previous experimental results.

  • PDF

CO2 net atmospheric flux estimation and influence factors analysis in a stratified reservoir (성층화된 저수지에서 CO2 NAF 산정 및 영향 인자 분석)

  • Park, Hyung Seok;Chung, Se Woong;Lee, Eun Ju
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2019.05a
    • /
    • pp.73-73
    • /
    • 2019
  • 지구 표면의 약 2%에 해당하는 담수에서 육상계 전체가 흡수하는 탄소의 50%가 배출되며, 이는 토양표면에서 배출되는 탄소량에 비해 더 큰 수치로 전 지구적 탄소순환 해석에 중요한 역할을 한다. 특히, 내륙수역과 대기의 경계면에서 $CO_2$ 이동은 전 지구적 탄소순환의 중요한 구성요소로 평가되고 있다. 호수와 저수지 같은 담수 저류시설은 육상에서 기인한 탄소의 운송 및 처리 역할을 한다. 하지만, 저수지에서 온실가스배출량을 평가할 수 있는 명확한 방법론이 부족하며, 전지구 규모 GHGs배출량에 대한 추정에 대한 불확실성이 상당히 큰 상황이다. 본 연구에서는 몬순기후대에 위치한 인공저수지를 대상으로 보다 신뢰도있는 온실가스 배출량 추정을 위해 $CO_2$ NAF 산정하고, 산정에 영향을 미치는 인자들을 분석 하였다. 분석을 위해 $CO_2$ NAF 산정에 필요한 수리 및 수질 인자들을 2017년부터 2018년까지 수집하고, 기초통계량 및 상관분석을 실시하였다. 또한, 주성분분석(PCA) 및 다중선형회귀모델(MLR)과 랜덤포레스트(RF) 기법을 사용해 변수 중요도를 평가하였으며, $CO_2$ NAF 산정 주요인자인 기체교환 계수를 경험적 모델 3종(Cole and Caraco, Crusius, Vachon), 표면갱신형 모델 4종(Heiskanen, Maclntyre, Read, Soloviev)을 비교, 검토하였다. 조사기간 동안 기체교환계수 산정 결과 Crusius 모델 예측값이 평균 $0.342(0.047{\sim}4.323)cm\;hr^{-1}$으로 검토한 모델중 가장 낮은 평균값을 보였으며, Heiskane 모델이 $2.135(0.337{\sim}5.152)cm\;hr^{-1}$으로 가장 큰 평균값을 보였다. 대상 수체는 연주기로 완전혼합되며 수온성층이 약화되는 시기에 저수지 표층 아래에 축적된 탄소가 표층으로 전달되어 높은 수준의 p$CO_2$를 보이며, 수표면에 큰 난류 강도가 작용하는 기간에 대기중으로 배출(pulse emission) 기작이 나타난다. NAF 산정결과 경험적 모델의 NAF값($-1246.0{\sim}6510.3mg-CO_2m^{-2}day^{-1}$)은 표면갱신형 모델 NAF값($-1436.1{\sim}8485.7mg-CO_2m^{-2}day^{-1}$)보다 낮은 수준을 보였으며, 풍속의 함수만을 이용하는 경험적 모델보다 부력 플럭스와 난류 혼합의 영향을 고려하는 Macintyre, Heiskanen모델이 성층 저수지의 $CO_2$ NAF 산정에 적합한 것으로 나타났다. $CO_2$ NAF 산정의 주요인자로 MLR모델은 Tw, EC, pH, Chla, TOC, Alk, RF모델은 EC, DO, TOC가 중요 변수로 평가되었다. PCA 분석결과, 수온이 낮고 성층이 약화되며 pH가 낮은 상태에서 NAF가 큰 것으로 나타났다.

  • PDF

Characteristics of Evaporation Heat Transfer in a Small-Scale Cryogenic Heat Exchange System for the Utilization of LNG Cold Energy (LNG 냉열활용을 위한 초저온 열교환시스템의 축소모형에서 증발 열전달 특성)

  • Nam S. C.;Lee S. C.;Lee Y. W.;Sohn Y. S.
    • Journal of the Korean Institute of Gas
    • /
    • v.2 no.4
    • /
    • pp.25-33
    • /
    • 1998
  • The characteristics of evaporation heat transfer for the utilization of LNG cold energy was investigated experimentally using liquified nitrogen and a solution of ethylene-glycol and water under horizontal two-phase conditions in the small-scale equipment of a cryogenic heat exchange system. The inner tubes in the double pipe heat exchanger with 8 mm and 15 mm inner diameter and 6 m length were adopted as a smooth test tubes and enhanced tubes by means of wire-coil inserts. Heat transfer coefficients and Nusselt number for the test tube were calculated from measurements of temperatures, flowrates and pressures. The correlations in a power-law relationship of the Nusselt number, the Reynolds number and Prandtl number for heat transfer were proposed which can be available for design of cryogenic heat exchangers. The correlations showed heat transfer coefficients for the wire-coil inserts were much higher than those for the smooth tubes, increased by more than 2.5 ${\~}$ 5.5 times depending upon the equivalent Reynolds number. Form and length of cryogenic double pipe heat exchanger were proposed for applicable to the utilization of LNG cold energy.

  • PDF

Closed Static Chamber Methods for Measurement of Methane Fluxes from a Rice Paddy: A Review (벼논 메탄 플럭스 측정용 폐쇄형 정적 챔버법: 고찰)

  • Ju, Okjung;Kang, Namgoo;Lim, Gapjune
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.22 no.2
    • /
    • pp.79-91
    • /
    • 2020
  • Accurate assessment of greenhouse gas emissions is a cornerstone of every climate change response study, and reliable assessment of greenhouse gas emission data is being used as a practical basis for the entire climate change prediction and modeling studies. Essential, fundamental technologies for estimating greenhouse gas emissions include an on-site monitoring technology, an evaluation methodology of uncertainty in emission factors, and a verification technology for reductions. The closed chamber method is being commonly used to measure gas fluxes between soil-vegetation and atmosphere. This method has the advantages of being simple, easily available and economical. This study presented the technical bases of the closed chamber method for measuring methane fluxes from a rice paddy. The methane fluxes from rice paddies occupy the largest portion of a single source of greenhouse gas in the agricultural field. We reviewed the international and the domestic studies on automated chamber monitoring systems that have been developed from manually operated chambers. Based on this review, we discussed scientific concerns on chamber methods with a particular focus on quality control for improving measurement reliability of field data.

Performance Characteristics of a Vapor Injection Heat Pump System with Different Sub-cooler Capacity (과냉각 열교환기 용량 변화에 따른 인젝션 히트펌프의 성능 특성)

  • Choi, Jong Min;Park, Yong-Jung;Kang, Shin-Hyung
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.10 no.3
    • /
    • pp.17-23
    • /
    • 2014
  • One major breakthrough in the field of heating, ventilation and air conditioning has been the development of heat pumps. Heat pump systems offer economic alternatives for recovering heat from different sources for use in various industrial, commercial and residential applications. In recent years, the heat pump has been tipped to have a very good potential for hot water production. This paper investigated the performance of a vapor injection heat pump with the variation of sub-cooler capacity at heating mode. The heating capacity of the vapor injection heat pump slightly increased with an increment of sub-cooler capacity, while COP didn't increase continuously. The 20% capacity of sub-cooler comparing with system capacity could be used as a standard to select sub-cooler capacity.

Difference in Right Ventricular Function between Post-tuberculosis Emphysema and Primary Emphysema (결핵후 폐기종과 원발성 폐기종에서 우심질 기능의 차이)

  • Kim, Myung-A;Kim, Sang-Hyun;Chung, Hee-Soon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.51 no.2
    • /
    • pp.97-107
    • /
    • 2001
  • Background : Tuberculosis itself causes not only lung parenchymal destruction but also pulmonary vascular damage. Secondary emphysema also causes pulmonary vascular damage, which can develop as a late sequela of pulmonary tuberculosis. Therefore, pulmonary circulatory impairment tends to be more severe in post-tuberculosis emphysema than in primary emphysema. In post-tuberculosis emphysema, the right ventricular function may play an important role. However, little information regarding the right ventricular function is available. The purpose of this study was to evaluate and compare the right ventricular function between post-tuberculosis emphysema and primary emphysema. Method: Post-tuberculosis emphysema(PTE) or primary emphysema(PE) was diagnosed by history, HRCT finding and pulmonary function. Twenty patients with post-tuberculosis emphysema were matched with 20 patients with primary emphysema according to both $FEV-1$ and FVC. Arterial blood gas analysis and echocardiography were done at rest and immediately after symptom-limited exercise. The right ventricular function was evaluated with the right ventricular ejection fraction using a modification of Simpson's method. Results : There was no significant difference in the demographics and pulmonary function between the two groups. In post-tuberculosis emphysema, the $PaCO_2$ was higher ($42.9{\pm}4.7$ vs $38.8{\pm}3.1\;mmHg$ at rest; $47.9{\pm}7.0$ vs $41.1{\pm}5.9\;mmHg$ after exercise; p<0.01) and the right ventricular ejection fraction was lower ($57.6{\pm}6.5$ vs $61.4{\pm}4.7%$ at rest; $51.1{\pm}10.8$ vs $59.8{\pm}6.6%$ after exercise; p<0.01) both at rest and after exercise. The $PaCO_2$ after exercise was also lower ($65.7{\pm}12.6$ vs $80.2{\pm}14.4\;mmHg$, p<0.01), while the Pa02 at rest tended to be lower($82.9{\pm}12.0$ vs $87.8{\pm}7.5$, p>0.05). In both groups, right ventricular ejection fraction correlated with the $PaCO_2$ after exercise(PTE r=0.536, PE r=0.557), and the $PaCO_2$ at rest(PTE r=-0.576, PE r=-0.588) and after exercise(PTE r=-0.764, PE r=-0.619). Conclusion : Impairment of the right heart function and gas exchange were more serious in post-tuberculosis emphysema than in primary emphysema, and gas exchange may be influenced by the right ventricular function in post-tuberculosis emphysema.

  • PDF

A Study on the Thermal-Hydraulic Characteristics of Molten Salt in Minichannels of an Intermediate Heat Exchanger for a Very High Temperature Reactor (VHTR) (초고온원자로 중간열교환기 미니챈널에서의 Molten Salt 열수력 특성 연구)

  • Jeong, Hui-Seong;Hwang, In-Seon;Bang, Kwang-Hyun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.12
    • /
    • pp.1093-1099
    • /
    • 2010
  • For Very High Temperature Reactors (VHTR), the designs of the Intermediate Heat Transport Loop (IHTL) and the Intermediate Heat Exchanger (IHX) are particularly difficult because of the high-temperature operation (up to $950^{\circ}C$). In this study, Flinak molten salt, a eutectic mixture of LiF, NaF, and KF (46.5:11.5:42.0 mole %) is considered as the heat transporting fluid in the IHTL. To evaluate the flow and heat transfer performance of the Flinak molten salt in small channels with hydraulic diameters in the millimeter range, a double-pipe heat exchanger was constructed using small-diameter tubes for the heat exchange between the Flinak and the gas flow. The experimental data showed that, for laminar Flinak flow, the measured friction factors were close to the 64/Re curve and the Nusselt numbers were generally between 3.66 and 4.36.

Development of 'Carbon Footprint' Concept and Its Utilization Prospects in the Agricultural and Forestry Sector ('탄소발자국' 개념의 발전 과정과 농림 부문에서의 활용 전망)

  • Choi, Sung-Won;Kim, Hakyoung;Kim, Joon
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.17 no.4
    • /
    • pp.358-383
    • /
    • 2015
  • The concept of 'carbon footprint' has been developed as a means of quantifying the specific emissions of the greenhouse gases (GHGs) that cause global warming. Although there are still neither clear definitions of the term nor rules for units or the scope of its estimation, it is broadly accepted that the carbon footprint is the total amount of GHGs, expressed as $CO_2$ equivalents, emitted into the atmosphere directly or indirectly at all processes of the production by an individual or organization. According to the ISO/TS 14067, the carbon footprint of a product is calculated by multiplying the units of activity of processes that emit GHGs by emission factor of the processes, and by summing them up. Based on this, 'carbon labelling' system has been implemented in various ways over the world to provide consumers the opportunities of comparison and choice, and to encourage voluntary activities of producers to reduce GHG emissions. In the agricultural sector, as a judgment basis to help purchaser with ethical consumption, 'low-carbon agricultural and livestock products certification' system is expected to have more utilization value. In this process, the 'cradle to gate' approach (which excludes stages for usage and disposal) is mainly used to set the boundaries of the life cycle assessment for agricultural products. The estimation of carbon footprint for the entire agricultural and forestry sector should take both removals and emissions into account in the "National Greenhouse Gas Inventory Report". The carbon accumulation in the biomass of perennial trees in cropland should be considered also to reduce the total GHG emissions. In order to accomplish this, tower-based flux measurements can be used, which provide a direct quantification of $CO_2$ exchange during the entire life cycle. Carbon footprint information can be combined with other indicators to develop more holistic assessment indicators for sustainable agricultural and forestry ecosystems.